You are on page 1of 1

RETAINED EARTH

COMPLETELY FILL AREA BEHIND


PLYWOOD WITH COMPACTED
SOIL OR CONCRETE

CAST-IN PLACE CONCRETE WALL

VOLTEX DS SEAMS SHOULD NOT


OCCUR AT INTERLOCKING OF
SHEET PILING

OPTIONAL TECHNIQUE:
PLYWOOD FASTENED TO
SHEET PILING TO FORM FLAT
SURFACE TO MOUNT VOLTEX

VOLTEX DS

WATERSTOP-RX MIN
75mm COVERAGE

1 METAL SHEET PILING / SHOTCRETE WALL


SCALE: NTS

INSTALL VOLTEX WITH DARK GRAY (WOVEN) GEOTEXTILE AGAINST CONCRETE

The information and data contained herein are believed to be accurate and reliable. For Technical Advice Contact: DRAWN BY: DATE:
This information does not constitute a warranty and should be used in conjunction with the Web: www.allco.co.nz ALLCO 05/19
project specification document supplied by Allco Waterproofing Solutions Ltd Email: info@allco.co.nz
Please contact Allco Waterproofing Solutions Ltd with any questions or deviations from Telephone: 09 448 1185
Facsimile: 09 448 1186
DRAWING REF: REV:
this information.
© Allco Waterproofing Solution Ltd V-W-05B 1