You are on page 1of 1

50MM MIN THICKNESS

NON-STRUCTURAL SHOTCRETE
PROTECT PILE FACING FROM
REBOUND AND OVERSPRAY
ALLOW FOR TOLERANCE OF
INCONSISTANT PILES. ALLLO FOR
100MM MIN CONCRETE COVERAGE
FROM WORST PILE

AQUADRAIN 15x

min
100
BENTOSEAL TO REINFORCING
PENETRATION

min
100

VOLCLAY VOLTEX TO PILE FACE


100mm MIN THICK REINFORCED
SHOTCRETE CONCRETE WALL
IN BETWEEN PILES TO
ENGINEERS DESIGN AND
DOCUMENTATION

1 SHOTCRETE WALL - BASEMENT WALL (BOXED OUT)


SCALE: NTS