Professional Documents
Culture Documents
- RETENTION STIRRUP / CAP TO PREVENT ANCHOR EJECTION POST TENSIONING BAR ETA05/0123 Ø36 M1:5
SHALL BE DESIGNED PROJECT-SPECIFIC BY sbp.
THIS MEASURE CAN EVENTUALLY BE OMITTED AFTER
THREADED BAR (WR) Ø36 GRADE 950/1050
CLEARANCE WITH CLIENT / APPROVING AUTHORITY. WITH SOLID RECTANGULAR ANCHOR PLATE
- ANCHOR BARS SHALL HAVE A MINIMUM LENGTH OF 2m PRESTRESSING FORCE P = 650 KN
BETWEEN UPPER AND LOWER ANCHOR PLATES !!
- INCLINED OR HORIZONTAL ANCHOR BARS HAVE TO BE UNBONDED TENDON WITHOUT FREE TENDON DUCT
PROTECTED FROM TRANSVERSE LOADS WITH APPROPRIATE CORROSION PROTECTION WITH HEAT-SHRINKING SLEEVE
MEASURES (CALIBERS AND INTERMEDIATE SUPPORTS)
CONCRETE GRADE MIN. C30/37
EXCESS LENGTH
FILL HOLLOW PARTS OF CONNECTION TUBE WITH CORROSION 267
219
PROTECTION COMPOUND AFTER PRESTRESSING.
550
INSTALL STEEL CAP AND GASKET ON ANCHOR PLATE USING
4 x M8 5.6 AND FILL CAP WITH CORROSION PROTECTION COMPOUND.
10
25
275
100 200
200
CAUTION:
LUBRICATED ON THE UNDERSIDE
60
60
AFTER INSTALLATION AND ADJUSTMENT OF STEEL STRUCTURE
ø110
FILL GAP BELOW BASEPLATE (D > 50mm) WITH NON-SHRINK TOP OF HEAT-SHRINKING SLEEVE
T
TOP OF PE-TUBE
200
ORIENTATION OF CAVITY TUBES MUST BE ENSURED USING
WELDED REBAR ø16 BST 500S.
BOTTOM OF PE-TUBE
60
100
BOTTOM OF FOUNDATION
X = 150
Y = 220
Rx ≥ 300 Ax = 230
Ry ≥ 300 Ay = 340
1 : 10 08.03.2013