NOTES:

- RETENTION STIRRUP / CAP TO PREVENT ANCHOR EJECTION POST TENSIONING BAR ETA05/0123 Ø36 M1:5
SHALL BE DESIGNED PROJECT-SPECIFIC BY sbp.
THIS MEASURE CAN EVENTUALLY BE OMITTED AFTER
THREADED BAR (WR) Ø36 GRADE 950/1050
CLEARANCE WITH CLIENT / APPROVING AUTHORITY. WITH SOLID RECTANGULAR ANCHOR PLATE
- ANCHOR BARS SHALL HAVE A MINIMUM LENGTH OF 2m PRESTRESSING FORCE P = 650 KN
BETWEEN UPPER AND LOWER ANCHOR PLATES !!
- INCLINED OR HORIZONTAL ANCHOR BARS HAVE TO BE UNBONDED TENDON WITHOUT FREE TENDON DUCT
PROTECTED FROM TRANSVERSE LOADS WITH APPROPRIATE CORROSION PROTECTION WITH HEAT-SHRINKING SLEEVE
MEASURES (CALIBERS AND INTERMEDIATE SUPPORTS)
CONCRETE GRADE MIN. C30/37

ANCHOR BAR WITH EXCESS LENGTH ACC. TO PRESTRESSING


INSTRUCTIONS, CUT OFF AFTER PRESTRESSING.
RETENTION CAP TO PREVENT ANCHOR EJECTION
PRESTRESSING JACK

STEEL CAP) MUST BE DEFINED PROJECT-SPECIFIC


EXCESS LENGTH (UND ACCORDINGLY HEIGHT OF
DYWIDAG
DOMED ANCHOR NUTS WITH GROUT SLOTS. 110Mp SERIES 01

EXCESS LENGTH
FILL HOLLOW PARTS OF CONNECTION TUBE WITH CORROSION 267

219
PROTECTION COMPOUND AFTER PRESTRESSING.

550
INSTALL STEEL CAP AND GASKET ON ANCHOR PLATE USING
4 x M8 5.6 AND FILL CAP WITH CORROSION PROTECTION COMPOUND.
10
25

CIRCULAR ANCHOR PLATE ø190 x 60 S355J2+N WITH BOREHOLE


ø49mm AND WELDED CONNECTION TUBE ø70 x 2,0 x L.
CONNECTION TUBE LUBRICATED ON THE OUTSIDE.

275
100 200
200

BASEPLATE A x B x T WITH BOREHOLES ø110

CAUTION:
LUBRICATED ON THE UNDERSIDE
60

60
AFTER INSTALLATION AND ADJUSTMENT OF STEEL STRUCTURE
ø110
FILL GAP BELOW BASEPLATE (D > 50mm) WITH NON-SHRINK TOP OF HEAT-SHRINKING SLEEVE
T

POURABLE MORTAR OR PAGEL (MIN. C60/75). COMPLETE VENTING OF


GAP MUST BE ENSURED BY MEANS OF APPROPRIATE MEASURES. TOP OF FOUNDATION
D

TOP OF PE-TUBE

CAVITY TUBE ø139,7 x 5 WITH BASEPLATE T = 5mm


AND BOREHOLE ø56mm. ACCURATE DISTANCE AND PARALLEL

200
ORIENTATION OF CAVITY TUBES MUST BE ENSURED USING
WELDED REBAR ø16 BST 500S.

TRANSITION BETWEEN CONNECTION TUBE AND PE-TUBE


100

MUST BE SEALED WITH A GASKET RING

INSTALLATION OF CORROSION PROTECTION COMPOUND,


ADHESIVE TAPE AND HEAT-SHRINKING SLEEVE ACC. TO
ETA05/0123 ANNEX 31a

ANCHOR BAR WITH HEAT-SHRINKING SLEEVE AND PE-TUBE ø52 x 2,0


MUST BE CHECKED FOR DAMAGE PRIOR TO INSTALLATION.
AREAS WITHOUT HEAT-SHRINKING SLEEVE MUST BE COATED
HX=210 / HY=320
WITH RUST-PROTECTION 310 ACC. TO APPROVAL Z-13.6-137.
ADDITIONAL REINF.

TRANSITION BETWEEN PE-TUBE AND HEAT-SHRINKING SLEEVE


MUST BE SEALED WITH ADHESIVE TAPE ACC. TO ETA05/0123
ANNEX 31a ON BOTH FIXED AND PRESTRESSING ANCHOR.
60

BOTTOM OF PE-TUBE
60

ADDITIONAL REINFORCEMENT 5 x ø12 BST 500S


60

100

ACC. TO ETA05/0123 ANNEX 24


BOTTOM OF HEAT-SHRINKING SLEEVE
60

TOP OF ANCHOR PLATE


50
20

RECTANGULAR ANCHOR PLATE 150 x 220 x 50mm


50

ACCURATE DISTANCE AND PARALLEL ORIENTATION OF ANCHOR


BARS MUST BE ENSURED USING REBAR ø16 BST 500S WELDED TO
THE ANCHOR PLATES (WELDING PRIOR TO INSTALLATION OF
ANCHOR BARS !!).
250

DOMED ANCHOR NUT (FIXED TO ANCHOR PLATE).

BOTTOM OF FOUNDATION

X = 150
Y = 220
Rx ≥ 300 Ax = 230
Ry ≥ 300 Ay = 340

1 : 10 08.03.2013