Professional Documents
Culture Documents
PROFILE
TERMINATION
ALUMINIUM COVER PLATES WITH MECHANICAL
DEPTH
MIN 1:100
70 M M
HEIGHT
FIXINGS MUST NOT BE USED TO PREVENT
VOIDING OF THE MEMBRANE SYSTEM
FINISHED
REBATE DEPTH
SET DOWN
FLOOR
HOB DEPTH
BUILT UP
SCREED
DEPTH
SELECTED TILES ON REBATE WIDTH
UNDERTILE WATER PROOFING
SELECTED ENGINEERED TIMBER OR TILE
PRIMARY BASE WATERPROOFING MEMBRANE TO FLOORING TO FINISH AGAINST ALUMINUM
LINE UP VERTICAL FACE OF SETDOWN AND WATERSTOP ANGLE
UP ALUMINIUM WATERSTOP ANGLE
PACKING TO LEVEL SUBSILL WITH
MEMBRANE PROTECTOR 'SNAKE SKIN'
MEMBRANE TO CONTINUE ACROSS BALCONY
POLYTHENE DAMP COURSE POLYCOURSE OR
AND INTO ROOF WASTE OUTLET
SIMILAR. CARE TO PROTECT MEMBRANE OF
PACKERS BY USE OF DPC
PRIMER APPLIED TO ALL MEMBRANED AREAS
WITH OVERCAPS AS PER MANUFACTURERS DYNA BOLT
DETAILS
CEMENTATIOUS NON-SHRINK GROUT FORMED
SCREED TO FALL WITH FALL, FINISH TO HOB TO SUPPORT AND LEVEL SUBSILL
BE NO FLATTER THAN 1:100 AS PER 10mm FOAM FILLER PACKING TO SCREED
CLAUSE 2.5.2 OF AS4654.2-2012 EDGE FOR THERMAL MOVEMENT
PRIMARY WATERPROOFING MEMBRANE TO
RUN UP VERTICAL FACE OF SLAB
SETDOWN AND UP ALUMINIUM ANGLE
STEP 3 STEP 2 STEP 1
WATERPROOFING MEMBRANES FOR EXTERNAL ABOVE STRUCTURAL DESIGN ACTIONS PART 2 : WIND LOADS FOR HOUSING AS4055-2012
GROUND USE, DESIGN & INSTALLATION WIND ACTIONS - TABLE 2.2 WIND CLASSIFICATION FROM WIND REGION & SITE
TO BE IN ACCORDANCE WITH TABLE A1, - AS/NZS 1170.2-2011 SYDNEY CONDITIONS
AS4654.2-2012 TYPICALLY 46M/S. ENSURE TO CONFIRM - SYDNEY = WIND REGION A
- WIND SPEED, ULTIMATE LIMIT STATE AGAINST PROJECT WIND STUDY - SYDNEY = TERRAIN CATERGORY, TYPICALLY TC3, CONFIRM PER
=70mm FROM STEPS 1. + 2. + 3. PROJECT
- TOPOGRAPHIC CLASS TYPICALLY T3- T4, CONFIRM PER PROJECT
REBATE WIDTH