You are on page 1of 4

3700 m of Grouting per floor

2240 m of Sawcut and sealant per floor

100mm
MIN.
31
mm 38
m
m
m
m
30
26 mm
TYPICAL HOLLOWCORE SLAB PARKING DECK AT
PCP-002
PRECAST BEAM DETAIL

WATER PROOF MEMBRANE 'V' GROOVE TO BE CUT IN


SEE ARCH SPECIFICATIONS 38mm DEEP AND 19mm
WIDE AT TOP OF V GROOVE

CONCRETE BONDING AGENT SEAL JOINT WITH SEALANT


AS PER ARCHITECTURAL
SPECIFICATIONS AND DETAILS

127 25 25 127 BONDED CONCRETE TOPPING,


MIN. 51mm THICK, SEE ARCH.
152 LEDGE 152 LEDGE FOR SLOPPING

15mm Ø WEEPING HOLE


AT 150mm OF EACH VOID END

GROUT SOLID

TYPICAL DETAILOF WATER PROOF AT INTERIOR


PCP-003
WALL / COLUMN

APPLY 30% SILANE SEALER


WATERING COURSE AND 600mm ABOVE TOP OF SLAB
MEMBRANE, SEE ARCH. ON ALL VERTICAL SURFACE
DRAWINGS AND PECIFICATIONS
TURN MEMBRANE UP 100mm MIN.
MIN. 5% SLOPE WITHIN ABOVE TOP SURFACE
600mm OF ALL WALLS

100mm
MIN.
SEALANT CANT BEAD
600 600

51mm
MIN.
BONDED CONCRETE TOPPING,
SEE ARCH.

GROUT EVERY CORE


SOLID

TYPICAL DETAILOF WATERPROOF AT PERIMETER


PCP-004
TYPICAL EXPANSION JOINT 2ND, 3RD & 4TH FLOORS PC-005 WALL / COLUMN

SAWCUT 6x6 REGLET.


EXTEND MEMBRANE INTO REGLET.
OVERLAP MEMBRANE & TRAFFIC
TOPPING 25 ONTO HEADER.
APPLY 30% SILANE SEALER
REGLET AND OVERLAP NOT 600mm ABOVE TOP OF SLAB
REQUIRED IF TRAFFIC TOPPING ON ALL VERTICAL SURFACE
INSTALLED BEFORE EXP. JOINT
INSTALLED. ELASTOMERIC MEMBRANE HEAT
WELDABLE (SANTOPRENE) SEAL TURN MEMBRANE UP 100mm MIN.
GLAND WITH 25 DIA. FACTORY ABOVE TOP SURFACE
TRAFFIC TOPPING
PUNCHED HOLES AT 38 O.C.
95 MIN. SEALANT CANT BEAD
ELASTOMERIC CONCRETE HEARDER
50 25 6

100mm
MIN. 5% SLOPE WITHIN

MIN.
600mm OF ALL WALLS

6
600

19
WATERING COURSE AND

MIN.
100

51mm MIN.
MEMBRANE, SEE ARCH.

VARIES
DRAWINGS AND PECIFICATIONS

SEE PLAN BONDED CONCRETE TOPPING,


AND SECTION SEE ARCH.
FOR JOINT WIDTH.
GROUT SOLID

GROUT EVERY CORE SOLID

REFER TO ARCH DRAWINGS


AND SPECS FOR FIRESTOP BELOW