ELECTRICAL LEGEND
WATER CONNECTION
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
SLOPE SLOPE
MUNICIPAL CONNECTION GI 55 mm. Ø
BOWSER CONNECTION GI 55 mm. Ø FLUORESCENT 45 Amp. COOKER
TUBE LIGHT SOCKET AND SWITCH
DISTRIBUTOR DOWN TAKE 36 mm. Ø
DISTRIBUTOR FOR BATH / TOILET / KITCHEN 25 mm. Ø FLUORESCENT
CEILING FAN
CONNECTION TO BATH, WATER HEATER 22 mm. Ø DOUBLE TUBE LIGHT
CONNECTION FOR OTHER INDIVIDUAL UNITS 15 mm. Ø
DRAINAGE CONNECTION WALL LIGHT WALL FAN
SLOPE SLOPE
FROM WASH BASIN ,BIDET 36 mm. Ø
FROM SINK , BATH & SHOWER 42 mm. Ø CEILING LIGHT EXHAUST FAN
FROM FLOOR TRAPS 80 mm. Ø
FROM WATER CLOSET 110 mm. Ø
W.P. WALL LIGHT FAN REGULATOR
DOWN TANK SOIL PIPE 110 mm. Ø
DOWN TANK WASTE PIPE 80 / 110 mm. Ø
VENT PIPE AND VENT STACK 80 / 110 mm. Ø CHANDELIER LIGHT BELL PUSH BUTTON
SLOPE SLOPE
NOTES :
1) NECESSARY REDUCER TO BE PROVIDED WHERE EVER ONE WAY SWITCH CALL BELL
n Denotes no of Gangs
REQUIRED TO MAINTAIN WATER PRESSURE
2) WATER HEATER AND EXHAUST FAN AT LEVEL 220 OBOVE.
MAIN DISTRIBUTION
n TWO WAY SWITCH
BOARD
n Denotes no of Gangs
ELECTRICAL NOTES:-
T.V. SOCKET AND
SLOPE SLOPE T.V. POSITION
SWITCH
1. EXACT LOCATION / POSITION SHALL BE DETERMINED AT SITE WITH CONSULTANT
ENGINEER / OWNER.
WATER HEATER
SWITCH DISH POSITION
NESSARY REDUCER TO BE PROVIDED WHERE EVER REQUIRED
2. ALL SYMBOLS MARKED ON THE DRG. SHOW TENTATIVE LOCATION / POSITION OF IN SIDE CAMERA OUT SIDE CAMERA
THE ELECTRICAL ACCESSORIES , EQUIPMENT AND LIGHTING FIXTURES ETC.
SLOPE SLOPE 3. ALL ELECTRICAL FITTINGS & FIXTURES SHALL BE OF APPROVED QUALITY DENOTES WEATHER
MANUFACTURE / DESIGN. WP WATER HEATER
PROOF
4. EACH LIGHT & FAN SHALL BE OPERATED BY AN INDIVIDUAL SWITCH.
5. STAIRCASE LIGHTING SHALL BE OPERATED BY TWO WAY SWITCH.
EL WINDOW AC
EMERGENCY LIGHT
6. ALL LIGHTING SWITCHES & SOCKET OUTLETS SHALL BE OF BEST QUALITY
AND MAKE MK/MEM / LEGRAND OR EQUAL & APPROVED UNLESS OTHERWISE BOUNDARY WALL
SPECIFIED. FLOOR LIGHT
LIGHT
ROOF PLAN 7.
8.
EACH FLOOR / BLOCK SHALL BE PROVIDED WITH SEPARATE
DISTRIBUTION BOARD.
ALL WIRING SHALL BE IN COLOUR CODE AND ALL LOAD SHALL BE BALANCED.
WALL TUBE LIGHT CEILING LIGHT (LED)
SCALE 1:100
STEP RISE LIGHT LED SPOT LIGHT
9. METERING PANEL BOARD SHALL BE PROVIDED OUTSIDE THE BLDG. IN IP 56
WEATHER PROOF HINGED TYPE ENCLOSURE WITH VISION PANEL AND LOCKING
FACILITY.
10. ALL EXTERNAL LIGHTING CONTROL SWITCHES SHALL BE PROVIDED WITH TIMER
GROUND FLOOR(WAREHOUSE-1) GROUND FLOOR(WAREHOUSE-2) INSIDE THE BUILDING AT NEAREST LOCATION OR OWNER'S REQUIREMENT.
11. ALL LIGHTING SWITCH BOXES & SOCKET OUTLET BOXES SHALL BE PROVIDED WITH
DETAILS NO. UNIT K.W DETAILS NO. UNIT K.W BRASS EARTHING TAG. TO CONNECT EARTH WIRES.
12. THE CONTRACTOR HAS TO PROVIDE CONDUITS COMPLETE WITH WIRING FOR
TELEPHONE & T.V. ANTENNA NETWORK TO OWNER'S REQUIREMENT.
LIGHTS 41 0.1 4.1 LIGHTS 41 0.1 4.1
13. ALL THE ELECTRICAL INSTALLATION SHALL BE CARRIED OUT IN
AIR CONDITIONERS 00 2.5 00 AIR CONDITIONERS 00 2.5 00 ACCORDANCE WITH LATEST I.E.E. & MHEW RULES & REGULATIONS.
SANITARY & PLUMBING LEGEND
14. ALL WATER HEATERS SHOULD BE LOCATED AT A HEIGHT OF 2.20 M. ABOVE THE
FLOOR LEVEL
FAN 00 0.1 00 FAN 00 0.1 00 15. PROPER WORKING DRAWINGS TO BE SUBMITTED BY THE CONTRACTOR BEFORE
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
THE COMMENCEMENT OF THE WORK
WATER HEATERS 01 1.5 1.5 WATER HEATERS 01 1.5 1.5 16. SPLIT A/C PROVISION TO BE PROVIDED AT ALL ROOMS MAJLIS HALL
3
4 " Ø COLD WATER PIPE
(CONCEALED)
WASHING MACHINE
SOCKET OUTLETS 10 0.2 2 SOCKET OUTLETS 10 0.2 2 AND WHERE EVER REQUIRED IN THE BUILDING ( SUCH AS PIPES ETC.) 3
4 " Ø HOT WATER PIPE BATH TUB WITH TEL.,
(CONCEALED) SHOWER TAP & CURTAIN