a) If you operate a function without operating the master control valve that function will not
work.
b) The master control valve on an air operated panel allows air pressure to go to each function in
preparation for you operating the function.
c) The master control valve must be held depressed while BOP functions are operated.
d) The master control valve must be depressed for five seconds then released before operating a
BOP function.
Answer:
a) True
b) True
c) True
d) False
2) The API RP53 states that closing time should not exceed X seconds for annular BOPs
smaller than 18-3/4″. What is the value of X?
a) 30 sec.
b) 60 sec.
c) 2 min.
d) 45 sec.
Answer: d
3) Which is the correct definition of the HPU reservoir volume according to API RP53?
Answer: a