Refinery Division
Captive Power Plant
Name : _______________________ EC. No _________________
Date : __________________
1. The Auxiliary Boilers are designed to operate under complete power failure condition to steam availability for
the safe shut down of refinery.
The Statement is True/ False.
a. 137.0 TPH , 115kg/cm2 g, 510 deg C b. 125.0 TPH , 115kg/cm2 g, 510 deg C
c. 100.0 TPH , 115kg/cm2 g, 515 deg C d. None of the above.
3. In case of steam pressure rise in boilers drum pressure safety valve should lift first, before superheater safety
valve
The Statement is True/ False.
12. Why drum coil pre-heater is provided in aux boiler ? What preacations we should take while operating it ?
13. What kind of control valve, fuel flow control valve is,
(a) Air fail to close (b) Air fail to open (c) Stay put (d) it is SOV
14. In aux boiler economiser outlet water temperature should not exceed,
(a) 277 degree C (b) 288 degree C (c) 232 degree C (d) 340 degree C
15. List out reasons of hydo test of pressure parts, and state the preacautions to be taken for hydro test.
16. What are the conditions for feed-water control from 1-element to 3-element and vice-versa.
Reliance Industries Limited
Refinery Division
Captive Power Plant
17. SCAPH in aux boiler is provided to,
(a) Increase BFW temperature.
(b) Controlling LP steam temprature
(c) For controlling MP steam temprature,
(d) For pre-heating air and increasing efficiency
21. In case of aux boiler scanner fan tripping the boiler will trip.
Statement is TRUE / FALSE.
22. Describe the taking in and taking out of boiler from HHP header pressure control.
25. Whar is the major loss in boilers and what are the limiting factors in controlling these losses ?
27. Write down causes and actions to be taken if drum level goes down.
30. What is the normal blow down setting of drum safety valve ?
31. What is the minimum GT load requirement for taking s/f in HRSG?
32. What is the minimum gas temperature required at GT exhaust and why?
38. How many scanners are used in HRSG –8 for oil and RFG burners ?
Reliance Industries Limited
Refinery Division
Captive Power Plant
39. What is the max SH metal temperature limit in BHEL HRSG ?
46. How HRSG is taken in / out of HHP steam header pressure control ?
48. What is the max limiting value of flue gas temperature before SH-2 ?
49. If purge ready is not available, what are the checks necessary tobe done ?
50. If steam separators are not fixed properly, what will be the effect ?
52. If actual FW flow is showing higher than steam flow, what dow you infer and what do you check ?
53. Can we run HRSG without scanner cooling air, what protection is incorporated ?
56. Write atleast two IPF recommendation which are implemented in CPP HRSG ?
61. Environ ment is surrounding in which an organization operates , including air , water , land and their
(a) Interaction
(b) Co-existance
(c) Mechanism
(d) None
62. Out of 7 dearators 7V2 is common to CPP and process. ( True / False )
Reliance Industries Limited
Refinery Division
Captive Power Plant
66. For Boiler Feed water pumps & Process feed water pumps close cooling water
(a) Is not required at all
(b) Is used for lube oil cooler
(c) Close cooling water failure will not affect the pumps
(d) None of above is true
67. What is the purpose of adding hydrazine in dearators ? Is there any other alternative chemical available ?
69. Are process feed water pumps ( HP / MP / LP ) are really an improtant equipment ? Explain their criticality in
brief.
70. It is reported by Laboratory that the silica level in boiler water is increased the permissible value then which of
the following action you will take.
(a) Reduce the operating pressure of boiler
(b) Increase the pH level of boiler slightly high.
(c) Bothe (a) and (b) action can be taken.
(d) Immediatly stop the boiler.
75. Which of the following protection is provided for condensor over pressrization
(a) Bursting disc
(b) Pressure Relief valve.
(c) Vacuume breaker valve
(d) Turbine Run down
76. Condensor Vacuum Low in STG alarm appears and STG starts unloading at
(a) 0.5 kg/cm2 ( abs )
(b) 0.2 kg/cm2 ( abs )
(c) 0.2 kg/cm2 ( g )
(d) 0.35 kg/cm2 ( abs )
85. What is the significance of Low pressure of HP & MP extraction steam from STG ? What are the measures
taken to avoid / prevent the risk of low pressure ?
86. Explain the vacuum pulling sequence. Draw Simple sketch of Ejector
88. Why barring gear is provided in STG and what speed does cut-in and cut-off takes place ?
89. Gas Turbine Takes lesser time to achieve FSNL in black start mode than normal start ( True / False ) , How ?
93. Gas Turbine is designed to start with Two out of three < R> , <S> , <T> processors ( True / False )
94. Gas Turbine can be started if AHOP is not available. ( True / False )
95. Multiple start-up of Gas Turbine are not desirable for Gas Turbine without cranking. Why ?
96. What could be the reason if Gas Turbine trips on “ High Exhaust Spread ” ?
97. Startin clutch will disengage during the start-up of Gas Turbine at
(a) FSNL
(b) Cranking speed
(c) Self sustaing speed
(d) When L14HA picks-up.
98. What is to be checked if Gas Turbine trips on “ Loss of Flame “ during the normal operation ?
99. What are the probable reason for Lube oil Tank level fluctuation ?
a. 500 deg C
b. 510 deg C
c. 471 deg C
d. none of above
a. To drive TFD
b. To use in SCAPH
c. As a atomizing steam
Reliance Industries Limited
Refinery Division
Captive Power Plant
103 The normal exhaust temperature of flue gas in Aux boilers is
a. 121 Deg C
b. 160 Deg C
c. 185 Deg C
104 At What Pressure levels steam are extracted from Steam turbine?
a. HP&MP
b. MP&LP
c. HHP&HP
d. HP&LP
105 Lube oil in STG is cooled by
a. FCW
b. CCW
c. Secured water
d. DM water
106 Flash tank drain pump uses
a. MP steam
b. LP steam
c. LLP steam
d. H P steam
107. STG condensate transferred to
a. Utility dept.
b. DM Water tanks
c. Deaerators
d. Cooling tower
(Yes/No)
114. Steam generation capacity of CPP is ___________ TPH
115. There are ____ pressure levels of process feed water supplied by
process feed pumps.
a. Condenser
b. Flash tank
c. Atmosphere
d. Pump suction
119. MD-4100 is added in CCW system for maintaining ----------------level more than 150
ppm to prevent ------------.
120 How many stages ( of extraction ) are there in the steam turbine.
a. Three.
b. Two
c. One
121 .All Gas Turbine is designed to burn liquid as well as Gas ( Yes / No )
122. Design atmospheric dew point of instrument air at dryer outlet is___
____ deg C
124. What type of lube oil used for warren pump lubrication?
a. SP46
b. SP32
c. SS150
d. SP100
d
125 IGV opening at time of FSNL should be
a. 34 DGA
b. 57 DGA
c..84 DGA
a. Turbine Only
b. Compressor Only
c. Compressor and Turbine Both
*****************