Assign an IP-

address(IP Unnumbered)
If system mode is IP unnumbered the command for IP configuration
is:
1.
AXXCLI>Device\Management-Conf
iguration\IP-Configuration
IP-
ADDRESS=193.69.136.104 SUBNE
T-MASK=255.255.255.0
For most commands, if no parameters are supplied then all the
current parameter values are displayed.
AXXCLI>IP-Configuration
IP-ADDRESS: 10.0.0.1
SUBNET-MASK: 255.255.255.0
DEFAULT-GATEWAY: 10.0.0.254 (optional)
2.1.4
Change Passwords
AXXCLI>
ch ?
Usage:
Change-Passwords
[AXXCLI-PASSWORD=<string[6:12]>]
[TELNET-PASSWORD=<string[6:12]>]
39
3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2
Quick Reference Guide
By this command, TELNET
and AXXCLI passwords can be
changed. Both passwords can be changed in the same command or
they can be changed one by one.
2.1.5
Erase a Community string
To remove a community string the following command can be used:
1.
AXXCLI>Community-Handler\
remove manager=0.0.0.0
community=public
2.
Press
Enter
.
MANAGER: 0.0.0.0
COMMUNITY: public
removed.
2.2
Set up connection to a Network Element
The purpose of this section is to describe the tasks involved in
setting up a connection between the Craft Terminal and any network
element from Ericsson AXXESSIT.
See also “Commissioning of IP
address via VT100 Interface” on page 2 -33. An Ethernet connection
to the MGMT port is required instead of the VT100 connection that
is used in previous sections of the manual
2.2.0.1
Start AXX 9820
CRAFT on your computer
1.
Replace the VT100 connection previous used, with an Ethernet
connection to the MGMT port .
2.
Select Start>Programs>AXX 9820 CRAFT>AXX 9820 CRAFT
Figure 19
Starting AXX 9820 CRAFT
AXX 9100 CONNECT R1.2
Quick Refere
nce Guide
3/1531-ZAP 701 14/1 Uen A 2006-10-16
40
3.
A logon window is presented for you.
Figure 20
AXX 9820 CRAFT Logon Window
4.
If present,
select
desired
network element
from Ip pull-down
menu.
Figure 21
Selection of IP address - Logon window
The system adds the selected IP address to the logon window.
Yo u
can also fill in the IP address manually
.
5.
Enter
community string
in the
password
field.
NOTE!
For non-AXXMETRO NEs, enter the configured SNMP
community string in the password field. The User field is not
applicable for NE types other than AXXMETRO.
6.
Click
Logon
to continue.
Community access levels:
The network element supports three community access levels

ReadOnly - only read access to the whole MIB

ReadWrite - read and write to the MIB, but can not change
community strings

Super - read and write to the complete MIB.
41
3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2
Quick Reference Guide
7.
The system validates the user-id/password and IP address
combination. If valid, i.e. combination correct and valid SNMP
community string, the Craft Terminal sets up a connection to the
specified IP address. The desktop of the Craft Terminal with its
working windows is presented to you.
You can now browse the network element topology and perform the
required management tasks.
2.2.0.2
Non-existent IP-address
The IP-address given by you manually or selected by you in the list,
is not reachable/non-existent or does not belong to an Ericsson
AXXESSIT network element. The syst
em gives an error message
and ask for a new IP-address.