You are on page 1of 1

450

NOTES:-
225 175 1. ALL DIMENSIONS ARE IN MILIMETERS UNLESS NOTED
OTHERWISE, ONLY WEITTEN DIMENSIONS AND REINF.
"A" 450
50 50 DETAILS SHALL BE FOLLOWED. NO DIMENSION SHALL
BE SCALED
CRASH
CRASH BARRIER
"B" BARRIER
2. GRADE OF CONCRETE IS TO BE M30
3. THE REINFORCEMENT SHALL OF HYSD BAR (GRADE
Fe-5000 CONFIRMING TO IS :1786
4. CLEAR COVER TO OUTERMOST STEEL SHALL BE AS BELOW

750
TOP OF CRASH BARRIER
RETAINING WALL REINFORCEMENT IN EARTH FACE--------------------75MM
300 IN OPEN FACE--------------------50MM
AS PER DETAIL

1100
IN FOUNDATION------------------75MM
5. SAFE BEARING CAPACITY SHOULD NOT BE LESS THAN THAT

OUTER FACE
GIVEN IN DETAILED DRAWING IN CASE ALLOWABLE SOIL BEARING
R25 CAPACITY , IS FOUND TO BE LESS THAN THE REQUIRED BEARING
0
8 CAPACITY , THE SOIL SHOULD STABILES TO ACHEVE THE

250
SAME, FOR THE PURPOSE THE WEAK SOIL LAYER SHALL BE

200
7 REMOVED & REFILLED WITH COMPACTED GRAVEL.

300
GEO TEXTILE
R5 6. 100 DIA WEEP HOLES WITH SLOPE 1 IN 20 SHALL BE
0 PROVED AT SPACING OF 1000 c/c BOTH HORIZONTALLY AND

H
FILTER MEDIA

HOLES @1000

150
300 VERTICALLY (STAGGERED) IN FULL HEIGHT OF THE RETAINING
600 THICK

150
c/c (TYP)
WALL WITH BOTTOM MOST ROW 150mm ABOVE G.L.

100
EARTH FACE

OUTER FACE
7. BACK FILLING AND FILTER MEDIA BEHIND THE RETAING
EARTH FACE

10 10 WALL SHALL BE PROVED WITH SELECTED EARTH CONFORMING


150 RETAINING WALL
7 + 8

300
8. TO COUNTER FOR THE DEFLECTION RETAINING WALL SHALL BE

K
N.G.L N.G.L 9 CONSTRUCTED TILTED BACK BY 1 IN 100.
9. MINIMUM LAP LENGTH FOR REINFORCEMENT SHALL BE 63 TIMES
THE DIA OF BARS.
2 RETAINING WALL
2 REINFORCEMENT
E AS PER DETAIL SPECIAL NOTED:-
6 +5 6 5
FOUNDING LVL DETAIL AT "A"
DETAIL AT "B"
(SCALE 1:15) FOUNDING SHOULD HAVE GRANULAR MATERIAL LIKE SANDY
(SCALE 1:15)
MURUM OR STONE DUST.
100 THK. PCC
LEVELLING 50XBAR DIA
D C B
300

COURSE(M15)
A
4 3
SECTION AT X-X 1
(SCALE 1:50)
REINFORCEMENT DETAILS
(SCALE 1:50)
STEM

X X
HEEL TOE

300
D C B
A
PLAN
(SCALE 1:50)
REINFORCEMENT DETAILS OF RCC RETAINING WALL:- DIMENSION DETAILS OF RCC RETAINING WALL

BAR MARKED TOTAL HEIGHT 2.0M TOTAL HEIGHT 3.0M TOTAL HEIGHT 4.0M TOTAL HEIGHT 5.0M TOTAL HEIGHT 6.0M SR.NO. TOTAL HEIGHT (HT) 2.0M 3.0M 4.0M 5.0M 6.0M
1 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 1 H 1.00 2.0 2.8 3.50 4.50

2 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 2 A 1.80 2.10 2.70 3.50 4.30

3 NOT USED NOT USED NOT USED 10 T


O @ 180c/c 12 T
O @ 200c/c 3 B 0.40 0.50 0.65 1.10 1.40

4 10 T
O @ 150c/c 10 T
O @ 150c/c 12 T
O @ 170c/c 10 T
O @ 180c/c 12 T
O @ 200c/c 4 C 0.40 0.40 0.50 0.60 0.70

5 10 T
O @ 150c/c 10 T
O @ 150c/c 12 T
O @ 150c/c 12 T
O @ 180c/c 16 T
O @ 200c/c 5 D 1.00 1.20 1.55 1.80 2.20

6 NOT USED NOT USED NOT USED 12 T


O @ 180c/c 12 T
O @ 200c/c 6 E 1.00 1.00 1.20 1.50 1.50

7 NOT USED NOT USED NOT USED 16 T


O @ 220c/c 16 T
O @ 200c/c 7 K 0.00 0.00 0.00 2.50 3.00

8 12 T
O @ 150c/c 12 T
O @ 150c/c 12 T
O @ 120c/c 16 T
O @ 220c/c 16 T
O @ 200c/c 8 T 0.40 0.40 0.50 0.60 0.70

9 10 T
O @ 150c/c 10 T
O @ 150c/c 12 T
O @ 200c/c 10 T
O @ 200c/c 12 T
O @ 200c/c 9 MAX. BASE PRESSURE 10 14 14 14 14
(T/M2) - AS PER DESIGN
10 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c 10 T
O @ 200c/c