M820-The Jumbo Frames of The ASMA Board Is Not Enabled Cause GE Fail
M820-The Jumbo Frames of The ASMA Board Is Not Enabled Cause GE Fail
cause GE fail
The ASMA board configurated GE , but the service is not working normally.
Networking Environment
2 、 Check the ASMA Board OCH optical power and OSNR is normal or not?
3 、 Check the service configuration is correct or not, whether the Client and LR / LT port are
binding in the same VLAN ?
1 、 Connect the GE swithes with the bare fibers , the service is working normally,so the
customer switch can be excluded
2 、 Check the ASMA Board OCH Optical Power and OSNR by OSA , and confirm they are normal
!
3 、 Test the service from the ASMA Client port with GE Analyzer while looping from another
site .The service is working normally !
4 、 After discussing with customer , we found that GE sent a jumbo frame , but ASMA port
default jumbo frame is disable . So that jumbo frame will be discarded.
Configure the jumbo Frame enable and the service will work normally .