ZXMP S385-How to check the ECC part of optical board by eping

command

ZXMP S385/Multi-service
Transport platform Network
Product Series/SDH based Multi- Management
service transport Version
platform/IPTN
Equipment
Equipment
Hardware
Software Version
Version
Board Hardware Board Software
Version Version
Incident Error
Page Views 3
Code
WHD201402253
Author HanWei Knowledge No.
93780

Incident Description (Incident Phenomena)

In some case, we want to check the ecc part of optical board, so we can loopback the optical port
by fiber, use the command eping to check it.
Networking Environment

in normal network environment.


Problem Cause Analysis

telnet ip address of NE, input eping command, the eping c ommand format is: eping McuAddr
Port Length Times Timeout.

As shown in the above, the result is 'Request timed out', So there is some problem in optical
board or loopback fiber.
Solution
As shown in the above, the result is OK, So the optical board is Ok.
Summary and Notes

the eping command usage is eping McuAddr Port Length Times Timeout

In order to test the No.1 port of the optical board in No.2 slot, we can extend the eping time.

For example: eping 2 1 100 100 500.