Unit of

Item Area Equipment Description Quantity Measure


1. chemical System of Complete gasket set for 1 Set
and waste each type and size.
Protection chemicals
Environm (vertical
ental pumps
centrifuges
submersible type
submersible)
(pit of
neutralization)
chemical System of
2. and waste
Protection chemicals
Environm (vertical complete set of
ental pumps bearings for every 2 1 Set
centrifuges pumps.
submersible type
submersible)
(Pit of
neutralization)
System
216. chemical separator complete set of
and oils and fats packages for each type
Protection Coalescing type and 1 Set
Environm industrial size.
ental
System
217. chemical separator Complete gasket set 1 Set
and oils and fats for every type and size
Protection Coalescing type
Environm industrial
ental
System
218. chemical separator complete set of 1 Set
and oils and fats bearings for every 2
Protection Coalescing type pumps
Environm industrial
ental
plant pumps
Set for each
treatment type and
219. chemical biological test Complete set of impeller. 1
and size of pump
sewage water supplied
Protection sanitary type
Environm aerobic.
ental
plant pumps
Set for each
treatment type and
220. chemical biological test Complete shaft/ axle set. 1
and size of pump
sewage water supplied
Protection sanitary type
Environm aerobic.
ental
plant pumps
Set for each
treatment type and size
221. chemical complete set of sleeve 1
biological test
and for shaft/ axle of pump
sewage water
Protection sanitary type supplied
Environm aerobic.
ental
plant pumps
Set for each
treatment type and size
222. chemical biological test Complete set of bearings 1
and sewage water of pump
Protection sanitary type supplied
Environm aerobic.
ental

Continuous NO cylinders in N2,


pieces for each
240. chemical Emissions certified in aluminum two
and system
Monitoring cylinders, and steel valves
Protection in stack and stainless type CGA-660 supplied
Environm air quality
ental
Continuous
SO2 cylinders in N2, pieces for each
chemical Emissions two
and certified in aluminum system
241. Monitoring
cylinders, and steel
Protection in stack and supplied
valves
Environm air quality
ental stainless type CGA-660
Continuous
CO cylinders in N2, pieces for each
chemical Emissions two
certified in aluminum system
242. and Monitoring
cylinders, and steel
Protection in stack and supplied
valves
Environm air quality
ental stainless type CGA-660
Continuous
O2 cylinders in N2, pieces for each
chemical Emissions two
certified in aluminum system
243. and Monitoring
Protection in stack and cylinders, and steel valves supplied
Environm air quality stainless type CGA-660
ental
Continuous
chemical Emissions pressure regulators for gas 4 pieces for each
245. and Monitoring cylinders. system
Protection in stack and supplied
Environm air quality
ental
The
necessary
for a
Consumable Parts Kit
period of
246. for a period of 2 years for Note 1
Continuous two 2)
chemical analyzers of O2, CO, SO2
Emissions years
and and NOx, constituted at least
Monitoring of
Protection with assemblies of the
in stack service
Environm capillaries, elements
filters and fuses. continuous
ental
depart from
the
Operation
Commerci
al
Continuous
247. chemical Emissions silica gel with moisture two kg for each
and Monitoring indicator system
Protection in stack and regenerable supplied
Environm air quality
ental
Continuous
Sample input filters, critical
248. chemical Emissions 10 pieces for each
and
orifice filters
Monitoring system
Protection in stack and (on probe and in cabinet) supplied
Environm air quality pump diaphragms
ental
Continuous
249. chemical Emissions Electronic multimeter. 1 piece for each
and Monitoring system
Protection in stack and supplied
Environm air quality
ental
Continuous Kit for a
Consumable material such
Emissions period of six
chemical as record cases, light bulbs,
250. Monitoring (6) months of
and LED's, printer paper, and 1
in stack and continuous
ink cartridges for a
Protection air quality service from
Environm one year period. Commercial
ental Operation for
each system
supplied
(Note 1)

Continuous
251. chemical Emissions repair kit 1 kit per system
and Monitoring pump supplied
Protection in stack and
Environm air quality
ental
Continuous
252. chemical Emissions Solenoid valves. 4 pieces for each
and Monitoring system
Protection in stack and supplied
Environm air quality
ental
Note 1: The Contractor must deliver a calculation report that justifies the amount to be supplied prior to the
delivery of the Spare Parts, as long as said report is not received, it will be considered that the
Contractor has not delivered the Spare Parts to which it refers
Note 2: Controls and instruments for the above systems shall be supplied as
requested in section 7.2.11.1 Spare Parts, in the Instrumentation and Control area of these Terms of
Reference, except for the System for measuring continuous emissions in the stack and air quality.