You are on page 1of 1

Friction loss calculation

Pumped fluid Static head Layout


Water, pure 8.5 Wet well installation

Flow Number of pumps Calculation model


10 m³/h 1 Colebrook-White

Viscosity Nature of system


1.569 mm²/s Single head pump

Type Ø ? or L Qty. v k ΔH
(mm) (m/s) (mm) (m)
Ø = Diameter v = Velocity k = Pipe roughness ΔH = Head loss
Common discharge side pipe - Plastic / PE100 (HDPE) PE 4710
SDR 17 (PN 10) / DN 65 (75x4,5 mm) / K factor for Wastewater acc. DWA-A110
Pipe length 66 155 m 1 0.8119 0.25 2.442
Total friction head 2.442

Friction loss head 2.442 m


Total static head 8.5 m
Total head 10.94 m

Project Created by Manuel Lineiro Last update 1/11/2023