4.4 Clariflocculator
Number of units (Nos.) 1.00
Diameter of clarifier (m) 15.80
Depth of side water column and free board (m) 3
Diameter of flocculation zone of each Clarifier 15.80
(m)
Slope of bottom floor (%) 01:10
- Surface Loading Rate (m2/Hr) As per CPHEEO Manual
- Detention time (hours)
- Vertical Raise rate (m/hr)
- Number and capacity of flocculation
paddles (KW)
- Scraper bridge drive capacity (KW)
- Material and diameter of sludge
withdrawal pipe
- bypass with control gate / valve
provided
4.5 Rapid sand filters Hence Provide 2 Nos. of Twin bed, Each single
- Number of filter beds (Nos.) bed having size of 2.25 m L X1.75 mW
- Size of each filter bed (m x m)
- Depth of filter bed and free board (m)
- Rate of filtration (lpm / m2)
- Depth of sand bed (m)
- Depth of supporting gravel media (m)
- Standing depth of water over filter bed
(m)
- Type of under drainage system
- Number and capacity of air blowers
- Material for piping and fittings
- Rate setters, filter rate controllers, filter
flow gauges, loss of head indicators, wash
water controllers and indicators, float
chambers, under drainage system,
calibrated notch etc. considered as per
specifications
- Sedimentation of filter back wash
water and return of supernatant to inlet
considered as per specifications
4.6 Size of below rooms / buildings As per RFP requirement and item no 2
considered:
- Chemical building (two storey) (m x m x
m)
- Air blower room (m x m x m)
- Office room (m x m x m)
- Electrical panel room (m x m x m)
- Control room (m x m x m) for PLC &
SCADA
- Laboratory (m x m x m)
- Disinfection room (m x m x m)
- Toilet (m x m x m)
- Staff quarters (m x m x m)
4.7 Filter Backwash Facility yes provided
Capacity of tank (m3) 55
Staging height (m) 4
Number and Capacity of Backwash pumps No. of Blowers 2Capacity of Blower
(Cum/min)5.90625
Valves & Fittings yes as per design
4.8 Details of disinfection facility meeting yes provided
CPHEEO / WHO guidelines
6 Other Parameters
6.1 Details of flow meter Pressure Gauge at each Pump
Discharge & Pressure
Transmitter at Common Delivery
6.2 Detail of Level Transmitter at ULGR
6.3 Detail of Level Indicator at ULGR
6.4 Pressure Gauge at each Pump Discharge & Yes
Pressure Transmitter at Common Delivery
6.5 Details of exhaust fans As per RFP requirement
ITEM – 6:-CLEAR WATER TRANSMISSION MAINS UP TO ESR:(foreach water
supply projects to be
furnished)
(100 marks & must score minimum 75 marks to
technically qualify)
Sl. Description Details to be filled by Bidder
No. for water supply project
(attach PDR sheets to
explain)
1 Number of hours of flow considered (hours) 20
2 Pipe :i) Material, ii)class of pipe, iii) length DI As per IS : 8329
of pipe
3 No of Air valves, scour valves, isolation 1 No Air Valve for each rising
valves etc. with valve chambers main, 1 scour valve, 3 isolation
valve
4 Pipe bridges, pipe support structures, As per site and re route of rising
ducts, concrete encasing, trenchless at SH, main condition
NH, railway crossings etc… for raw water
pumping main
ITEM – 7:- BOOSTER STATIONS: (If required)(for each water supply
projects to be furnished)
(100 marks & must score minimum 60 marks to technically qualify)
Sl. Description Details to be
No. filled by Bidder
for each water
supply project
IBPS- IBPS-
1 1
Booster Sumps & Booster Pumping Station Part - Part -
A 2 – 22
–
No.
CWR
within ESR –
WTP at
to – 1 Zone-
No. 2
ESR
at
Zone-
1
1 Hours operation (m3/Hr) 36 849.6
2 Number of compartments (Nos.) 2 2
3 Capacity of each compartment (m3) 591.84 16967.
52
4 Clear height of pump room (m) 4.5 4.5
5 Number of pumps W + S (Nos.) 2+1 3+3
6 Type of pumps HCF HCF
7 Design head for each clear water pump (m) 260 305
8 Material for piping and fittings
9 Number and size of valves As per As per
a) Actuator operated butterfly valves on suction (Nos. / design design
mm)
b) Non return valves (Nos. / mm)
c) Actuator operated butterfly valves on delivery (Nos. /
mm)
d) Automatic air valves (Nos. / mm)
e) Expansion joint / bellow (Nos. / mm)
f) Any other
10 Capacity of EOT crane / Chain pulley block (Ton) 4.5 3.5
Ton Ton
11 Source and distance of electricity supply Electri Electri
city city
12 Transformer capacity (KVA) 350 1000
13 Details of surge protection system yes yes
14 Size of below rooms: As per As per
- LT room (m x m x m) Item Item
- Control Room (m x m x m) no 2 no 2
15 Details of flow meter yes yes
16 Detail of Level Transmitter yes yes
17 Pressure Gauge at each Pump Discharge & yes yes
Pressure Transmitter at Common Delivery
18 Details of exhaust fans as per as per
NIT NIT
DETAILS OF ESR
Type of tank : ELSR / GLSR capacity(ltr) capacity(m3