Professional Documents
Culture Documents
Impenetrable design:
By molding the weathersheds directly onto the core and over the end fittings under high pressure and high 120 kN 160 kN 120 kN 160 kN
- Shed profiles Standard End fitting Specified Shed profile Number of sheds Material
type mechanical designation
Grading ring
Three different profiles :
XF, XM, XL giving necessary load in kN
Grading rings are required to reduce the voltage
leakage distance to answer F for IEC S for Socket XF S for silicone rubber gradient on and within the insulator.
pollution conditions N for ANSI B for Ball XM E for EPDM rubber
Power arc can be deverted by the horn supporting
Y for Y Clevis XL the ring without damage to insulator:
- Covering materials :
- ARMOURSIL® Silicone rubber T for Tongue
coupling size 16 A : 20 kA 0,5s
which minimises leakage current and C for Clevis coupling size 20 A : 25 kA 0,5s
prevents arcing even in very polluted and E for Oval Eye (1 shot, according to IEC 61467)
salt water environments.
- ARMOURLITE® EPDM rubber which has proven its
efficiency over a wide range of climates, contamination
level and line voltage since 1975. *For application beyond the range listed here, please contact us for details. *For application beyond the range listed here, please contact us for details.
Sediver composite insulator: Sediver ARMOURSIL ® composite insulators Sediver ARMOURSIL ® composite insulators
most current requirements * most current requirements *
an impenetrable design
Impenetrable design:
By molding the weathersheds directly onto the core and over the end fittings under high pressure and high 120 kN 160 kN 120 kN 160 kN
- Shed profiles Standard End fitting Specified Shed profile Number of sheds Material
type mechanical designation
Grading ring
Three different profiles :
XF, XM, XL giving necessary load in kN
Grading rings are required to reduce the voltage
leakage distance to answer F for IEC S for Socket XF S for silicone rubber gradient on and within the insulator.
pollution conditions N for ANSI B for Ball XM E for EPDM rubber
Power arc can be deverted by the horn supporting
Y for Y Clevis XL the ring without damage to insulator:
- Covering materials :
- ARMOURSIL® Silicone rubber T for Tongue
coupling size 16 A : 20 kA 0,5s
which minimises leakage current and C for Clevis coupling size 20 A : 25 kA 0,5s
prevents arcing even in very polluted and E for Oval Eye (1 shot, according to IEC 61467)
salt water environments.
- ARMOURLITE® EPDM rubber which has proven its
efficiency over a wide range of climates, contamination
level and line voltage since 1975. *For application beyond the range listed here, please contact us for details. *For application beyond the range listed here, please contact us for details.
Sediver ARMOURSIL ® composite insulators
most current requirements *
120 kN 160 kN
220/275 kV FSB 120 XF 75 S1 2008 5607 615 530 1115 FSB 160 XF 75 S1
with 1 75 2319 FSB 120 XM 75 S1 2015 6371 620 535 1115 FSB 160 XM 75 S1 2354
grading
ring FSB 120 XL 75 S1 2032 8453 625 535 1125 FSB 160 XL 75 S1
FSB 120 XF 79 S1 2118 5907 650 555 1170 FSB 160 XF 79 S1
79 2429 FSB 120 XM 79 S1 2125 6712 650 555 1175 FSB 160 XM 79 S1 2464
FSB 120 XL 79 S1 2142 8905 655 560 1185 FSB 160 XL 79 S1
FSB 120 XF 87 S1 2338 6509 715 600 1285 FSB 160 XF 87 S1
87 2649 FSB 120 XM 87 S1 2345 7395 715 605 1290 FSB 160 XM 87 S1 2684
FSB 120 XL 87 S1 2362 9809 720 605 1295 FSB 160 XL 87 S1
FSB 120 XF 101 S5 2634 7561 800 655 1435 FSB 160 XF 101 S5
101 3034 FSB 120 XM 101 S5 2634 8589 800 655 1435 FSB 160 XM 101 S5 3069
FSB 120 XL 101 S5 2634 11392 800 655 1435 FSB 160 XL 101 S5
FSB 120 XF 107 S5 2799 8012 845 680 1520 FSB 160 XF 107 S5
107 3199 FSB 120 XM 107 S5 2799 9101 845 680 1520 FSB 160 XM 107 S5 3234
400/500 kV
FSB 120 XL 107 S5 2799 12070 845 680 1520 FSB 160 XL 107 S5
with 2
grading FSB 120 XF 111 S5 2909 8313 880 695 1580 FSB 160 XF 111 S5
rings 111 3309 FSB 120 XM 111 S5 2909 9442 880 695 1580 FSB 160 XM 111 S5 3344
FSB 120 XL 111 S5 2909 12522 880 695 1580 FSB 160 XL 111 S5
FSB 120 XF 117 S5 3074 8764 925 720 1660 FSB 160 XF 117 S5
117 3474 FSB 120 XM 117 S5 3074 9954 925 720 1660 FSB 160 XM 117 S5 3509
FSB 120 XL 117 S5 3074 13200 925 720 1660 FSB 160 XL 117 S5
Grading ring
Grading rings are required to reduce the voltage
gradient on and within the insulator.
*For application beyond the range listed here, please contact us for details.
Sediver Business Unit is the insulator division of SEVES International Glass
Sediver ARMOURSIL ® composite insulators group, a world leader in the technical glass industry whose headquarters are
most current requirements * located in Europe - Florence, Italy.
For more than 60 years Sediver has been specialised in the research, design,
manufacturing and testing of glass and composite insulators and surge
arresters for high voltage power networks and railway catenary systems.
210 kN Silicone Insulators Physical Electrical IEC 300 kN Silicone Insulators All our manufacturing plants are ISO 9001-2000 certified and are governed by
IEC coupling 20 Characteristics Withstand Values (kV) IEC coupling 24 the same Quality Assurance program and organisation. This ensures that all
Line voltage Number of Spacing Product Arcing Leakage Dry Power Wet Power Lightning Product Spacing Sediver insulators are manufactured following the same methods and
application Sheds (mm) reference distance distance Frequency Frequency Impulse reference (mm)
procedures, in order to supply all customers worldwide with insulators of the
FSB 210 XF41 S0 1142 3074 360 295 655 FSB 300 XF 41 S0
41 1495 1536
same quality.
FSB 210 XL 41 S0 1183 4777 370 305 675 FSB 300 XL 41 S0
132/170 kV
FSB 210 XF 25 S0 1417 3831 440 375 800 FSB 300 XF 51 S0 Composite insulators listed in this catalogue are manufactured in Brazil and are
51 1770 1811 in full conformity with IEC 61109 standard and ANSI C29.11.
FSB 210 XL 25 S0 1458 5950 455 390 825 FSB 300 XL 51 S0
FSB 210 XF 77 S1 2057 5798 630 545 1140 FSB 300 XF 77 S1
77 2485 2526
FSB 210 XL 77 S1 2088 9000 640 550 1155 FSB 300 XL 77 S1
220/275 kV FSB 210 XF 85 S1 2287 6403 700 590 1260 FSB 300 XF 85 S1
85 2705 2746
with 1 grading FSB 210 XL 85 S1 2308 9939 705 595 1270 FSB 300 XL 85 S1
Namibia 400 kV line
ring FSB 210 XF 95 S1 2562 7160 780 640 1400 FSB 300 XF 95 S1
95 2980 3021
FSB 210 XL 95 S1 2583 11112 785 645 1410 FSB 300 XL 95 S1
FSB 210 XF 115 S2 3047 8673 915 715 1650 FSB 300 XF 115 S2
115 3530 3571
FSB 210 XL 115 S2 3047 13458 915 715 1650 FSB 300 XL 115 S2
FSB 210 XF 121 S2 3212 9127 965 740 1730 FSB 300 XF 121 S2
121 3695 3736
FSB 210 XL 121 S2 3212 14162 965 740 1730 FSB 300 XL 121 S2
Namibia 400 kV line
with 2 grading FSB 210 XF 143 S2 3817 10791 1135 825 2035 FSB 300 XF 143 S2
rings 143 4300 4341
FSB 210 XL 143 S2 3817 16743 1135 825 2035 FSB 300 XL 143 S2
FSB 210 XF 149 S2 3982 11245 1180 850 2120 FSB 300 XF 149 S2
149 4465 4506
FSB 210 XL 149 S2 3982 17447 1180 850 2120 FSB 300 XL 149 S2
FSB 210 XF 179 S4 4757 13515 1395 1035 2505 FSB 300 XF 179 S4
179 5290 5331
FSB 210 XL 179 S4 4757 20966 1395 1035 2505 FSB 300 XL 179 S4
Packing
The packing method illustrated beside have been developed to
minimize possible damage during shipment and storage as well as
to reduce space and freight cost.
Sediver S.A.
Sediver composite insulator
Commercial and Marketing Headquarters
Composite insulators are packed in reinforced wooden crates and
are protected against moisture by a polyethylene film.
79, avenue François Arago
92017 Nanterre Cedex France
for high voltage overhead lines
Tel. +33.(0)1.46.14.15.24 - Fax +33.(0)1.46.14.15.32
sales@sediver.fr - www.sediver.fr
*For application beyond the range listed here, please contact us for details.
Sediver Business Unit is the insulator division of SEVES International Glass
group, a world leader in the technical glass industry whose headquarters are
located in Europe - Florence, Italy.
For more than 60 years Sediver has been specialised in the research, design,
manufacturing and testing of glass and composite insulators and surge
arresters for high voltage power networks and railway catenary systems.
Composite insulators listed in this catalogue are manufactured in Brazil and are
in full conformity with IEC 61109 standard and ANSI C29.11.
Sediver S.A.