You are on page 1of 29

For OLED Panel Diagnostics, see page 22 (Also available in Article 9268)

SMART POWER TEST JIG GUIDE


Using
g Multi Gender Board
Notice: Prices are subject to change without notice.

4.25 inches
Multi-Gender Board Jig
p/n: RAD33187801 (Sold Separately ($22.30))

3.35 inches
s
1.10 inches

Smart TV Test Jig (Sold Separately)


p/n: RAD32507801 ($43($43.60)
60)
Published: June 28th, 2017 (Ver 01)
Version 9 Updated: October 25th, 2017 (Ver 08)
Items Needed for Utilizing Smart Jig, Multi-Gender Board

Multi-Gender Board
to Smart Test Jig
Cable Included

Multi-Gender Board
p/n: RAD33187801
($43.60)

Not Included: Solder two needle tips (one on each


end) to a 6 inch insulated wire. Cover solder
connections with heat shrink tubing
tubing.

Note: You may receive


Needle to Needle
a cable like this with Jumper (Hand Made)
two 18pin connectors
on the Smart Jig side.
The unnecessary ※Only needed for B7, G7 and W7 Panel Diagnostic Test.
connector will be zip Usage explained from page 18 ~ 21.
tied in place. In the Smart Power
future this additional Supply Test Jig ※ For the EG9100 Series models you will need an
connector may be alligator clip jumper wire instead of this needle tipped
p/n:
/ RAD32507801 jumper. Usage explained beginning on page 14.
utilized, but it is not
necessary at this time. ($22.30)
Page 2 of 29
Page 3 of 29
Power Board Multi Gender JIG Layout (P/N: RAD33187801)
※ 12/13/2014 Smart JIG
connector applied

28Pin 24Pin 24Pin 24Pin NC

1. New
1 N 18Pi
18Pin
Smart JIG 2015/2016 24Pin
2015 2015
(LF/UF Series) (OLED)
Zip tied o
on 3 plug cables

24Pin
28Pin
2013/2014

2. Old
Smart JIG 2017
(OLED)
24Pin Use this
24Pin
2012 port for B7
/ G7 24pin

To the Smart See Notes


TV Test
T t Jig
Ji N t Page
Next P
“A”
2016/2017
18Pin
(UH/UJ)

12Pin 12Pin 28Pin 28Pin


28Pin
24Pin Check
2017 2016 2016/2017 2016/2017 2016
Cable connection (UH)
(SJ/UJ) (LH/LJ) (UH/SJ) (UH Series)
Also 49UJ63
Page 4 of 29
Power Board Multi Gender JIG Diagnostic Model List
Existing 2012, 2013, 2014, 2015 LED models included. *Note 1: Special Note for OLED Test:
N l added
Newly dd d function:
f ti 2015
2015, 2016
2016, 2017 OLED,
OLED The Multi
Multi-Gender
Gender board and Smart Jig does not check OLED
2016/2017 LED model Power diagnosis Power Supplies completely.
The issue will be 12VT/20VD or 24VD, voltages which connect
<2015/2016/2017 OLED Model, 2016/2017 LED Model> “directly” to the T-CON board.
If you come across an OLED Power Supply that the
Year Product Model
12VT/20VD or 24VD directly y to the T-CON do not
EG91 Power Test OK, (See note1 and 2 on right) turn on during this test, it may be because the
2015 *OLED EG92/EG93/EG94/EG96 (Use P8 plug) 12V_ON (12VT_ON) command is not sent from the
EF95 (Use P8 plug) Smart Jig to the Power Supply.
B6 (Use P7 plug) Be sure to check for approximately 3V on the
C6 (Use P10 plug) 12V_ON line if these voltages are missing before
*OLED condemning the Power Supply.
E6 (Use P10 plug)
G6 (Use P10 plug)
Models that are confirmed that
2016 UH95/UH96 (Use P14 plug) (79” Use P15 plug)
UH85/UH93 (Use P15 plug) Do Not turn on voltages to the T-CON
UH77/UH87 (Use P13 plug) (No 12VT_ON command):
LED W7: (No 12VT or 24VD)
UH75/UH76 (Use P13 plug)
UH65/UH68 (Use
( P13 plug)) B7/G7: 24VD (Yes),
(Yes) 12VT (No)
(No).
LH54, LH60, LH66, LH68 (Use P16 plug)
Additional Note:
B7 (See note 1 on right) Use W7 P13 plug
The 12V 13.2V, 18V, 20V or 24V to the Main board
C7 (Use P11 plug)
is always checked, but these are different
2017 *OLED E7 (Use P11 plug)
regulators on the Power Supply than voltages that
G7 (See note on right) Use W7 P13 plug
W7 (See note on right) Use W7 P13 plug
are sent to the T
T-CON.
CON

SJ95/UJ98 (Use P18 plug) (79SJ95 Use P15 plug) Note 2: VIDEO TEST (Panel Diagnostics):
SJ85/UJ94 (Use P13 plug) See page 22. (Also available Article 9268).
SJ80, UJ77 (Use P13 plug) (See note 2 on right) “OLED Panel Diagnostics Guide.”
UJ75/UJ78 (Use P13 plug) Note: You will use this document to turn on the
2017 LED
UJ65/UJ68 (Use
(U P13 plug)
l ) P
Power Supply
S l which
hi h iin tturn provides
id power to
t the
th
UJ63/UJ67 (Use P13 plug) (49UJ63 Use P17 plug) Smart Power Test Jig and T-CON Board.
LJ61/LJ68 (Use P13 plug) EG91,2,3,4: See Page 14
LJ55/LJ58 (Use P13 plug) LCD “UJ77” Jump 12V to T-CON. (Pg 29).
Page 5 of 29
How to Connect the Multi Gender Board to the Smart Power Test Jig

▶ Plug cable into the Multi Gender Board: Into port (MAIN Jig In)

“A: 2013 LCD POWER”


2014

▶ Connect the Multi Gender board to the (black) connector


as shown in picture above.
Page 6 of 29
Smart Test Jig Voltage Setting Switch Guidelines

3 4

▶ Switch the power ▶ LCD MODEL: Check the


Switch on JIG to LCD
LCD. power voltage and switch to
the correct voltage.
▶ Check power board Voltage Label to the Main board. See rules below.

※ Rules Related to Switch Settings:


(The correct power diagnosis can be made only if the switch is set correctly.)
- 24V Power Board: Change the switch to 24V of Smart Jig Voltage
- 20V Power Board: Change the switch to 20V of Smart Jig Voltage
- 13.2V or 18V Power Board: Change
g the switch to 24V of Smart Jig
g Voltage
g

Power Supply Smart Jig Voltage


(To Main) Switch Setting
24V 24V
20V 20V

13.2V or 18V 24V


2016 / 2017 LED 18Pin Power Board Diagnostic Method

1 2

▶ Check
Ch k power board
b d voltage,
l (13
(13.2V).
2V) ▶ Disconnect the Main Board 18Pin Power Cable connector.

3 4

▶ Set the PRODUCT SWITCH on SMART JIG to LCD.


▶ LCD MODEL SWITCH: Set the switch to 24V.
▶ Check Voltage out to the Main Board.
▶ Apply Power: When the OK LED turns on, Power
▶ Connect the 18Pin Power Cable connector Board is normal.
to the Multi Gender JIG 18Pin connector ▶ When the NG LED turns on, the Power Board
can be judged as defective.
Page 7 of 29
2016 LED (UH95, UH96) Power Board Diagnostic Method
1 2

▶ Check power board voltage


voltage. (18V) ▶ Disconnect the Main Board 28Pin Power Cable connector
connector.

3 4

▶ Apply Power; when the OK LED turns on,


Power Board is normal. Backlights should be On.
▶ Connect the 28Pin Power Cable connector
to the Multi Gender JIG 28Pin connector ▶ Check all voltages out to the Main board.
▶ Set the PRODUCT SWITCH on SMART JIG to LCD. ▶ When the NG LED turns on, the Power Board
▶ LCD MODEL SWITCH: Set the switch to 24V. can be judged as defective.
Page 8 of 29
2016 / 2017 LED (UH85, UH93) Power Board Diagnostic Method
1 2

▶ Check power board voltage (12V and 24V)


24V). ▶ Disconnect the Main Board 28Pin Power Cable connector
connector.

3 4

▶ Connect the 28Pin Power Cable connector ▶ Apply Power; when the OK LED turns on,
to the Multi Gender
G JIG
G 28Pin P15 connector. Power Board is normal.
normal Backlights should be On
On.
▶ Set the PRODUCT SWITCH on SMART JIG to LCD. ▶ Check all voltages out to the Main board.
▶ LCD MODEL SWITCH: Set the switch to 24V. ▶ When the NG LED turns on, the Power Board
can be judged as defective.
Page 9 of 29
2016 / 2017 LED 12Pin Power Board Diagnostic Method

1 2

▶ Check power board voltage


voltage. ▶ Disconnect the Main Board 12Pin Power Cable connector
connector.

3 4

▶ Apply Power; when the OK LED turns on,


▶ Connect the 12Pin Power Cable connector Power Board is normal. Backlights should be On.
to the Multi Gender JIG 12Pin connector
▶ Check all voltages out to the Main board.
▶ Set the PRODUCT SWITCH on SMART JIG to LCD.
▶ LCD MODEL SWITCH: Set the switch to 24V. ▶ When the NG LED turns on, the Power Board
can be judged as defective.
Page 10 of 29
2016 LED 12Pin Power Board Diagnostic Method (And 49UJ63**)

1 2

▶ Check power board voltage


voltage, (13
(13.2V).
2V) ▶ Disconnect the Main Board 12Pin Power Cable connector
connector.

3 4

Also
49UJ63**

▶ Apply Power; when the OK LED turns on,


▶ Connect the 12Pin Power Cable connector
Power Board is normal. Backlights should be On.
to the Multi Gender JIG 24Pin connector
▶ Set the PRODUCT SWITCH on SMART JIG to LCD. ▶ Check all voltage out to the Main board.
▶ LCD MODEL SWITCH: Set the switch to 24V. ▶ When the NG LED turns on, the Power Board
can be judged as defective.
Page 11 of 29
2017 LED 28Pin Power Board Diagnostic Method

1 2

▶ Check
Ch k power board
b d voltage
lt (13.2V
(13 2V and
d 20V)
20V). ▶ Disconnect
Di t the
th Main
M i Board
B d 28Pin
28Pi P
Power C
Cable
bl connector.
t

3 4

▶ Apply Power; when the OK LED turns on,


▶ Connect the 28Pin Power Cable connector Power Board is normal. Backlights should be On.
to the Multi Gender JIG 28Pin connector ▶ Check all voltages out to the Main board.
▶ Set the PRODUCT SWITCH on SMART JIG to LCD.
▶ When the NG LED turns on, the Power Board
▶ LCD MODEL SWITCH: Set the switch to 20V. Note: 20V can be judged as defective.
Page 12 of 29
2015 OLED (EG91, 92, 93, 94, EG96, EF95) Power Board Diagnostic Method (1 of 2)

1 2

▶ Set the PRODUCT SWITCH on SMART JIG to LCD.


▶ LCD MODEL SWITCH: Set the switch to 24V.
24V
▶ Check power board voltage, (12VM and 24VS).

3 4

▶ Disconnect the Main Board 24Pin Power Cable connector. ▶ Connect the 24Pin Power Cable connector to the Multi
Gender JIG 24Pin connector (P8 Port).

Page 13 of 29
2015 OLED (EG91, 92, 93, 94, EG96, EF95) Power Board Diagnostic Method (2 of 2)

5 6 Green

▶ When the OK LED turns on, Power Board is normal.


▶ When the NG LED turns on, the Power Board
▶ Apply Power to the Set. can be judged as defective.

Be sure to check all voltages from the Power Supply to the Main Board and to the T-CON Board.
7 MAIN VOLTAGES: T-CON
T CON VOLTAGES:
• 3.5V, (P201 pins 5, 7, 8) • 12VT, (P203 pins 7-12)
• 12VM, (P201 pins 11-15) • 24VD, (P202 pins 8-14)
• 24VS, (P201 pins 19-22)

NOTE: EG91 SERIES: Only necessary if you want to run the Panel Diagnostic Test. (Also see Article 9268 for details)
In the EG91 Series OLED, the 12VT for the T-CON is routed out of the Main board through the LVDS Cable. 12VT is routed from the
Power Supply to the Main Board and to the T-CON Board. To run the OLED Video Panel Test (rolling test patterns) it will require an
additional step. You will have to Jump 12V from the Power Supply to the T-CON Fuse.

MAIN VOLTAGES: T-CON VOLTAGES:


• 3.5V, (P201 pins 5, 7, 8) • 12VT, (P7200 (LVDS) pins 1-4) Not active when using the Smart Jig test.
• 12VM,
12VM (P201 pinsi 11
11-15)
15) (Y will
(You ill h
have tto JJump 12V ffrom th
the P
Power S
Supply
l tto th
the T
T-CON
CON F
Fuse).
)
• 24VS, (P201 pins 19-22) • 24VD, (P203 pins 8-15)

Page 14 of 29
2016 OLED (C6, E6, G6, B6) Power Board Diagnostic Method (1 of 2)

1 2

▶ Set the PRODUCT SWITCH on SMART JIG to LCD.


▶ LCD MODEL SWITCH: Set the switch to 24V.
24V
▶ Check power board voltage, (12VM and 24VS).

3 4

▶ For C6, E6, and G6, Connect the 24Pin Power Cable
connector to the Multi-Gender JIG 24Pin connector (P10 Port).

▶ Disconnect the Main Board 24Pin Power Cable connector. ▶ For B6, Connect the 24Pin Power Cable connector to the Multi
Gender JIG 24Pin connector (P7 Port).

Page 15 of 29
2016 OLED (C6, E6, G6) Power Board Diagnostic Method (2 of 2)

5 6 Green

▶ When the OK LED turns on, Power Board is normal.


▶ When the NG LED turns on, the Power Board
▶ Apply Power to the Set. can be judged as defective.

7 For C6, E6, and G6, Check all voltages from the Power Supply For B6 model, check this Power Supply to the Main
to the Main Board and to the T-CON Board. Board and to the T-CON Board.
• MAIN VOLTAGES: • MAIN VOLTAGES:
• 3.5V_ST, (P201 pins 5, 7, 8) • 12VM, (P201 pins 5,7,8 and 13-15)
• 12VM, (P201 pins 11-15) • 24VS, (P201 pins 19-22)
• 24VS,
24VS (P201 pins 19-22)
19 22) • T-CON
T CON VOLTAGES:
• T-CON VOLTAGES: • 12VT, (P203 pins 7-12)
• 12VT, (P202 pins 7-12) • 24VD, (P202 pins 8-15)
• 24VD, (P203 pins 8-15)

Page 16 of 29
2017 OLED (C7, E7) Power Board Diagnostic Method (1 of 1)

1 2

▶ Check power board voltage


voltage, (12V and 20V)
20V). ▶ Connect
C the 28
28Pin Power C
Cable connector
▶ Disconnect the Main Board 28Pin Power Cable connector. to the Multi Gender JIG 28Pin connector P11.

3 Green
4

▶ Connect the 24Pin Power Cable connector to the


Multi Gender JIG 28Pin connector P11.
▶ Set the PRODUCT SWITCH on SMART JIG to LCD.
▶ LCD MODEL SWITCH: Set the switch to 20V.
▶ Apply Power, when the OK LED turns on, Power
Board is normal.
Note: 20V
▶ When the NG LED turns on, the Power Board
can be judged as defective.
Page 17 of 29
2017 OLED (B7, G7) Power Board Diagnostic Method (1 of 2)

1 2

▶ Set the PRODUCT SWITCH on SMART JIG to LCD.


▶ Check power board voltage
voltage, (12V and 20V)
20V). ▶ LCD MODEL SWITCH: Set the switch to 20V.
20V
▶ Disconnect the Main Board 28Pin Power Cable connector.

3 4

ATTENTION:
For the 24Pin
Connector type,
Do not use P11.
Use the 24Pin
connector P13
P13.
(Labeled W7)

▶ Unplug the 24Pin Power Cable connector ▶ Connect the 24Pin Power Cable connector
from the Main board. to the Multi Gender JIG 24Pin connector P13.

Page 18 of 29
2017 OLED (B7, G7) Power Board Diagnostic Method (2 of 2)

5 SPECIAL STEP FOR THE B7, G7. Unplugged Side of Main Board P1001

20VS 23 24 20VS
NOTE: These pin 20VS 21 22 20VS
numbers are Main
Gnd 19 20 Gnd
Board plug side.
12VM 17 18 12VM
15 16
8th pin up from
Gnd
12V_ON b tt
bottom right.
i ht
Gnd 13 14 Gnd
6th pin up from 11 12
Add Jumper PWR_ON
ACD
bottom left
Gnd 9 10 12VM
▶Add a jumper wire (Needle tip on each end) 7 8
12VM 12VM
between Pins 11 and 16 P1001 sideside, (13 and 10
5 6
P201 side). This will give the command to the 20VS 20VS
Power Supply to turn on the 12VT to the T-CON. Add Jumper Gnd 3 4 Gnd

DRV_ON 1 2 DPC

7 Check all voltages from the Power Supply


to the Main Board and to the T-CON Board.
• MAIN VOLTAGES:
• 12VM, (P201 pins 7-8, 16-18)
• 20VS, (P201 pins 1-4,
1 4, 19-20)
19 20)
• T-CON VOLTAGES:
• 12VT, (P202 pins 14, 16, 18, 20, 22, 24)
• 24VD, (P202 pins 13, 15, 17, 19, 21, 23, 25, 27)

WARNING: To use the Smart Jig & Multi-Gender board or run


▶ Apply Power
Power, when the OK LED turns on
on, Power OLED PPanell Di
Diagnostics
ti on th
the G7 andd B7 requires
i a Jumper
J
Board is normal. between PWR_ON and 12V_ON. If you feel uncomfortable or
▶ When the NG LED turns on, the Power Board unable to make and/or use a needle jumper, please do not attempt.
can be judged as defective.
Page 19 of 29
2017 OLED (W7) Power Board Diagnostic Method (1 of 2)

1 2

▶ Set the PRODUCT SWITCH on SMART JIG to LCD.


▶ LCD MODEL SWITCH: Set the switch to 20V.
20V
▶ Check power board voltage, (12VM and 20VS).

3 4

▶ Connect the 24Pin Power Cable connector


▶ Disconnect the Main Board 24Pin Power Cable connector.
to the Multi Gender JIG 24Pin connector P13.

Page 20 of 29
2017 OLED (W7) Power Board Diagnostic Method (2 of 2)

5 SPECIAL STEP FOR THE B7, G7. Unplugged side of Main Board P1001

No Wire 23 24 20VS

NOTE: These pin No Wire 21 22 20VS


numbers are Main No Wire 19 20 Gnd
Board plug side.
No Wire 17 18 12VM
8th pin up
No Wire 15 16 from bottom
12V_ON
Add Jumper 6th pin up Gnd 13 14 right.
Gnd
from bottom
11 12 ACD
left PWR_ON
Gnd 9 10 12VM
7 8
▶Add a jumper wire (Needle tip on each end) 12VM 12VM

between Pins 11 and 16. 20VS 5 6 20VS


This will give the command to the Power Supply Add Jumper 3 4
Gnd Gnd
to turn on the 12VT to the T-CON.
1 2
Note: SMPS pins numbers are different. DRV_ON DPC

Check all voltages from the Power Supply


6 7 to the Main Board and to the T-CON Board.
• MAIN VOLTAGES:
• 12VM, (SMPS P201 pins 7, 8, 16, 17, 18),
(MAIN P1001 pins 7, 8, 10, 18)
• 20VS,, (SMPS
( P201 pins
p 1,, 2,, 3,, 4,, 19,, 20)) ,
(MAIN P1001 pins 5, 6, 22, 24)
• T-CON VOLTAGES:
• 12VT, (P251 pins 14, 16, 18, 20, 22, 24)
• 24VD, (P251 pins 13, 15, 17, 19, 21, 23, 25, 27)

▶ Apply
pp y Power,, when the OK LED turns on,, Power WARNING: To use the Smart Jig & Multi-Gender
Multi Gender board or run
Board is normal. OLED Panel Diagnostics on the W7 requires a Jumper between
PWR_ON and 12V_ON. If you feel uncomfortable or unable to
▶ When the NG LED turns on, the Power Board make and/or use a needle jumper, please do not attempt.
can be judged as defective.
Page 21 of 29
Use in conjunction with Smart TV Power Test “Previous”: Also Articles 9267 and 9268.

OLED PANEL DIAGNOSTIC GUIDE


Using Smart JIG, Multi Gender Board
and the OLED Panel Diagnostic Cable
Forcing the Panel to develop Test Patterns without the Main board to Isolate video issues.

Smart TV Test Jig Multi-Gender Board Jig


p/n: RAD32507801 (Sold Separately $43.60) p/n: RAD33187801 (Sold Separately $22.30)

OLED Panel Diagnostic Cable


p/n: AGF79219801
(Sold Separately $5.60)

Published: June 28th, 2017 (Ver 01)


Version 8
Updated: November 28th, 2017 (Ver 08)
Page 22 of 29
OLED / LCD Panel Diagnostic Cable Model List
OLED Panel Diagnostic Cable Model Year: 2015, 2016, 2017. OLED Panel Diagnostic Cable Model Year: 2017.
<2015/2016/2017 OLED Models> <2017 LCD Models>

Year Product Model Year Product Model


EG91 Power Test OK, (See note on right)
UJ77 (See note on right)
2015 *OLED EG92/EG93/EG94/EG96 (Use P8 plug) 2017 *LCD
Use LCD16/17 P12 plug
EF95 (Use P8 plug)
B6 (Use P7 plug) *Special Note for LCD Test:
C6 (Use P10 plug)
2016 *OLED UJ77 Series:
E6 (Use P10 plug)
Must jump 13.2V from Power Supply to T-CON fuse.
G6 (Use P10 plug)
See special note page 29.
B7 (See note on right) Use W7 P13 plug
C7 (Use P11 plug)
2017 *OLED E7 (Use P11 plug)
G7 (See note on right) Use W7 P13 plug
W7 (See note on right) Use W7 P13 plug

*Special Note for OLED Test:


The Multi-Gender
Multi Gender board and Smart Jig does not check all OLED Power Supplies completely
completely.
The issue will be 12VT/20VD or 24VD voltages which connect “directly” to the T-CON board. If you come across an OLED Power
Supply that the 12VT/20VD or 24VD directly to the T-CON do not turn on during this test, it may be because the 12V_ON (12VT_ON)
command is not sent from the Smart Jig to the Power Supply.
Be sure to check for approximately 3V on the 12V_ON line if these voltages are missing before condemning the Power Supply.

Models that are confirmed that


Do Not turn on voltages to the T-CON Additional Note:
(No 12VT_ON command): The 12V 13.2V, 18V, 20V or 24V to the Main board is always checked,
W7: (No 12VT or 24VD) but these are different regulators on the Power Supply than the ones
B7/G7: 24VD (Yes), 12VT (No). that are sent to the T-CON.

VIDEO TEST (Panel


(P l Diagnostics):
Di ti )
See Article 8267 “Power-Test-Smart-Jig-Multi-Gender-Guide” for Details below.
See special notes on the G7, B7 page 19 and W7 on page 21 related to “How to turn these voltages on during the Test” so that the
Video Test can be run. EG9100: See special note page 29.
Page 23 of 29
Items Needed for Utilizing Smart Jig, Multi-Gender Board

Smart Power Supply Test Jig ($43.60) N dl tto N


Needle Needle
dl JJumper (H
(Hand
dMMade)
d )
p/n: RAD32507801
Not Included: Solder two needle tips (one on each
end) to a 6 inch insulated wire. Cover solder
connections with heat shrink tubing.

※Only needed for B7, G7 and W7 Panel Diagnostic Test.


Usage shown on page 7, (Also see Article 9267).

※ For the EG9100 and UJ77 Series models you will need
an alligator clip jumper wire instead of this needle tipped
jumper. Usage explained Page 29 (Also in Article 9267)

Multi-Gender Board
Cable Included

($5 60)
($5.60)
Multi-Gender Board OLED Panel Diagnostic Cable
($22.30)
p/n: RAD33187801 p/n: AGF79219801
Page 24 of 29
Power Board Multi Gender JIG Layout (P/N: RAD33187801)

2015 2015/2016
(LF/UF Series) (OLED)
※ 12/13/2014 Smart JIG
connector applied 28Pin 24Pin 24Pin 24Pin NC

2015 18Pi
18Pin
24Pin

2013/2014 24Pin
28Pin

2017
(OLED)

2012 24Pin Use this


24Pin
port for B7
/ G7 24pin

To the Smart
TV Test Jig 2016/2017
18Pin
“A” (UH/UJ)

12Pin 12Pin 28Pin 28Pin


28Pin

2017 2016 2016/2017 2016/2017 2016


(SJ/UJ) (UH) (LH/LJ) (UH/SJ) (UH Series)
Also 49UJ63
Page 25 of 29
How to Connect the Multi Gender Board to the Smart Power Test Jig

▶ Plug cable into the Multi Gender Board: Into port (MAIN Jig In)

“A: 2013 LCD POWER”


2014

▶ Connect the Multi Gender board to the (black) connector


as shown in picture above.
Page 26 of 29
Smart Test Jig Voltage Setting Switch Guidelines

1 2

▶ Switch the power ▶ LCD MODEL: Check the


Switch on JIG to LCD
LCD. power voltage and switch to
the correct voltage. See
▶ Check power board voltage to the Main board. rules below.

※ Rules Related to Switch Settings:


(The correct power diagnosis can be made only if the switch is set correctly.)
- 24V Power Board: Change the switch to 24V of Smart Jig Voltage
- 20V Power Board: Change the switch to 20V of Smart Jig Voltage
- 13.2V/18V Power Board: Change
g the switch to 24V of Smart Jig
g Voltage
g

Power Supply Smart Jig Voltage


(To Main) Switch Setting
24V 24V
20V 20V

13.2V/18V 24V

Page 27 of 29
How to Connect the OLED Panel Diagnostics Cable Page 28 of 29

3 4 p/n: AGF79219801

“Module” Label:
This plugs into the
This plugs T-CON board.
into the Smart
Test Jig
▶ OLED Panel Diagnostic Cable notes.
▶ Hook the TV up using the normal Smart Power Supply
Test Jig and Multi-Gender Board. This will allow the TV to
be turned on and apply power to the Panel and T-CON
Board. DO NOT turn set on at this time. 6
N/G OK
5 “Module” Label

▶ Unplug both “Vx1” LVDS Cables to the T-CON Board.


▶ Plug the Diagnostic Cable into the Smart Jig. ▶ Plug the “Module” label side of the Diagnostic Cable
Note: Not the “Module” label side. Exposed pins Go down. into the T-CON Board (51 pin). Exposed pins go down.
Page 28 of 29
Set-Up for using the OLED Panel Diagnostics Cable Page 29 of 29

▶ See Article 9267 for complete details related to proper hook-up of NOTES:
the Multi-Gender board and the Smart Power Test Jig to your panel.
▶I
▶Important:
t t Disconnect
Di t “Both”
“B th” V
Vx1
1 (LVDS) cables.
bl
7 Smart Jig to
▶ It is necessary for the Power Supply to be producing the
Multi-Gender
12VT and the 20VD or 24VD to the T-CON.
OLED Diagnostic Vx1 Cables ▶ Note: Follow the specific steps for setting up your specific
Cable from Smart disconnected
Model TV to run correctly when connected to the Smart
Jig to T-CON
T CON
Jig and Multi-Gender Board.
Diagnostic Cable The Green “OK” LED on the front of the Smart Jig must be
plugged into
turned on, (Illuminated).
T-CON 51pin
▶ For Most Models, you do not need to add a jumper.
Additional Jumper But for some Models they will require the addition of a
required
q only
y on
“Jumper”
Jumper wire (as shown in the example on the left for a
some models.
B7 OLED model.
Multi-Gender The following OLED series models (B7, W7 and G7)
Board to turn on require a jumper wire to activate the 12V_ON command to
Power Supply the Power Supply so the 12VT and the 20VD or 24VD
voltages will turn on.
▶ Apply Power to the Set and observe the front of the OLED (All off these
th will
ill use th
the same 24pin
24 i connector
t on the
th
Panel. It should be producing Patterns on the screen. Multi-Gender board P13, (lower right). The Jumper jumps
▶ OLED Patterns may vary by panel design. Some will be PWR_ON to 12V_ON. (See previous section for details).
rolling test patterns of Black, White, Red, Green, Blue, then
repeats with a lower IRE level. The OLED “EG91, 2, 3, 4” series and LCD “UJ77”
Other ppanels have section sweep pppatterns that run Series models require jumping 12V from the Power
horizontally then vertically. Supply to the T-CON because this model receives 12VT
from the Main board through the LVDS cable. Use a small
▶ If the Panel fails to product patterns on the screen. Confirm the alligator clip lead type jumper for easier attachment.
12VT and 20VD or 24VD to the T-CON. Note: Before applying power, Diode check the Fuse on
Be sure the check these voltages on the T-CON board itself. the T-CON for a possible short.
There will be fuses for both voltages.
WARNING T
WARNING: To use th
the S
Smartt Ji
Jig & M
Multi-Gender
lti G d board
b d or run
If they are present see T-CON Troubleshooting to confirm if the OLED Panel Diagnostics on the G7, B7 or W7 requires a Jumper
problem is the T-CON board or the Panel that needs replacing. between PWR_ON and 12V_ON. If you feel uncomfortable or
unable to make and/or use a needle jumper, please do not attempt.
Page 29 of 29