Combustion stability tuning scheme

1、Air volume ratio adjustment of upper windbox and lower windbox

The windbox inlet damper initial position(with design coal)


Boiler load RO 75%

Upper damper Front 80 100


open % Rear 65 75

Lower damper Front 100 75


open % Rear 80 65

2、Stability adjustment of single burner


Adjust the single burner with large fluctuation of flame scanner signal, dark flame, flicker and
other poor combustion conditions.
It mainly adjusts the opening of the inner SA adjustable vane, outer SA adjustable vane, the
air zone disk and other parameters of the burner.
Status of burners on December 27
Front C1 B1 A1 C2 B2 A2 F1 E1 D1 F2 E2 D2
state √ √ √ √ √ √ √ √ not running × × not running

Rear D3 E3 F3 D4 E4 F4 A3 B3 C3 A4 B4 C4
state × × not running
not running × × × √ √ √ √ ×
× means adjustment is required

3、Variable oxygen adjustment


Increase the secondary air volume on the basis of the design value, operate with 5.5% and 6%
oxygen at the outlet of the economizer, and observe the stable combustion condition of the boiler.