Column Check

Calculation complies with SP 63.13330.2018 with Сhange No. 1

Importance factor    n = 1

Importance factor (Serviceability limit state)    1

Member length 7 m
Effective length factor in the XoY plane 2
Effective length factor in the XoZ plane 2
Random eccentricity along Z 20 mm
Random eccentricity along Y 20 mm
Structure is statically determinate
Limit slenderness - 120
Section

300 Z 300
300

600
300

b = 600 mm
h = 600 mm
a1 = 24 mm 600
a2 = 24 mm

Reinforcement Class Service factor


Longitudinal A500 1
Transverse A240 1

Concrete
Concrete type: Heavy-weight
Concrete grade: B40
Dead weight of concrete 2.5 T/m3
Service factor for concrete
b1 allowance for the sustained loads 1
b2 allowance for the failure behavior 1
b3 allowance for the vertical position during concreting 0.9
b5 allowance for the freezing/thawing and negative temperatures 1

Humidity of environment air - 40-75%

Crack Resistance
Limited crack opening width
Requirements to crack opening width are based on the preservation of reinforcement
Allowable crack opening width:
    Short-term opening    0.4 mm
    Long-term opening    0.3 mm

Schematic of segments

Specified reinforcement
Segment Length (m) Reinforcement Section
1 7 S1 - 2Ж32
S2 - 2Ж32
Transverse
reinforcement
along axis Z
2Ж10, spacing
of transverce
reinforcement
200 mm
Transverse
reinforcement
along axis Y
2Ж10, spacing
of transverce
reinforcement
200 mm

Loads

Load case 1
Type: permanent
Safety factor for load: 1
Factor for sustained load: 1
N 100 T T 0 T*m
My1 0 T*m Mz1 0 T*m
Qz1 0T Qy1 2T
My2 0 T*m Mz2 14 T*m
Qz2 0T Qy2 2T
qz 0 T/m qy 0 T/m

Load case 2
Type: temporary short-term
Safety factor for load: 1
Factor for sustained load: 1
N 100 T T 0 T*m
My1 0 T*m Mz1 0 T*m
Qz1 0T Qy1 2T
My2 0 T*m Mz2 14 T*m
Qz2 0T Qy2 2T
qz 0 T/m qy 0 T/m
Results
Checked according to
Segment Utilization Factor Check
SP
1 0.233 Strength for the ultimate longitudinal force of
the section
0.732 Ultimate moment strength of the section
0.501 Strains in compressed concrete Sec. 8.1.20-8.1.30
0.057 Strains in the tensile reinforcement Sec 8.1.20-8.1.30
0.476 Longitudinal force with the deflection taken Sec. 8.1.15, 7.1.11
into account for slenderness L0/i>14
0.016 Strength in a concrete strip between oblique Sec. 8.1.32, 8.1.34
sections
0.098 Strength for an oblique section Sec. 8.1.33, 8.1.34
0.674 Limit slenderness in XoY plane Sec. 10.2.2
0.674 Limit slenderness in XoZ plane Sec. 10.2.2

Report created 2022.12.02 10:18:38 (UTC+03:00) by ARBAT (64-bit), version: 21.1.9.9 dated 16.04.2021