CRACK WIDTH R2 (I.S.

CODE METHOD) PROJECT: Reliance Nagar C

Concrete Grade N/mm2 30


Dia. Of the bar mm 16
Spacing of the bars c/c mm 150
Area of tension steel for the width given mm2 1286.1
Area of compression steel mm2 720
width of the section (b) mm 1000
Depth of section (D) mm 300
Creep coefficient 1.6
Working Moment at the secton (D+L) T-m 8.8
Clear cover to Tensile steel mm 25
Effective cover to compression steel mm 25
Modulus of elasticity of steel (Es) N/mm2 200000
Effective cover to steel (d') mm 33
Effective depth (d) mm 267
Pre-stressing Force (P) KN
Eccentricity of the Tendons mm
Section Modulus (Z) mm 15000000
Compressive stress due to induced Pre-stress N/mm2 0.00
De compression moment Tm 0.00
Net working moment at the secton (D+L) Tm 8.80
Short term Modulus of elasticity of concrete (Ecs) N/mm2 27386

Long Term Modulus of elasticity of concrete (Ecl) N/mm2 10533


Modular ratio (m2) for Cracked section 18.99
Depth of neutral axis for long term Ec . (x) mm 85.09
2nd mt. of area of cracked section for Long Term Ec . (Icr) mm4 1062814797
Strain in cracked section (e1) 0.001689
Average steel Strain at the level of cracking (em) 0.001360
Directly under
Location of the point at soffit, where crack width is required the bar
location
Distance from the point considered to the surface of the nearest longitudinal bar (acr) mm 25
CRACK WIDTH (The -ve value indicates uncracked section.) mm 0.102
PROJECT: Reliance Nagar Coil

30
FST ( Steel stress)
16
150 285.98
1286.1 FC (Concrete
720 stress)
1000 17.79
300
1.6
8.8
25
25
200000
33
267

Pre-stressing
15000000 Parametres. If not
0.00 done, put C16 and
C17 as zero
0.00
8.80
27386 As per Pillai &
Menon
10533 (m=280/3*cbc)
18.99 9.33
85.09 65.51
1062814797 591888103
0.001689 0.001626
0.001360 0.001273
Mid way of Mid way of two
two bars bars
73.94 73.94
0.207 0.199