Product

Feed PKS 4800kCal/Kg W.V Char BioSynGas Fuels


35 40 20 5
1000 350 400 200 50
Temperature C at exit 75 350 28 75
Cp 1 0.25 0.20 0.42
Heat at exist 17,500 32,500 120 1,050 51,170
Internal Heat U 5,908 1,650 8,500
Potential Heat 2,363,200 330,000 425,000 3,118,200
Moisture PKS 18% Moisture 180 Kg
Heat Energy from Heaters 330,769 kCal/hr

Potential Heat in the BioSynGas 330,000 kCal/hr


kCal in PKS Cp 4800kCal/Kg 3,936,000 kCal/hr
4,266,769 kCal/hr
Heat to be Dissipated 1,097,399 kCal/hr
hg of water at 30C 608 kCal/kg
Cooling tower water "Loss" 1,805 Kg
Process Under Vacuum
P Hg"
V ?
PV=nRT