Datos de consumo Datos de panel Hiku CS3W-390

Potencia facturada = 3000 W Pmax = 405 W Imp =


Energia consumida = 97000 Wh/mes Vmp = 38.9 V Isc =
3233.3 Wh/dia Voc = 47.4 V
HSP = 5.5

Cuadro de cargas
Carga Potencia [W] Cantidad Horas Energia consumida [Kwh/dia]
Bomba cisterna 745.7 1 2 1.49
Refrigeradora 121.0 1 6 0.73
Planchadora 1200 1 0.5 0.60
Televisor 90 2 4 0.72
Computadora 65 1 2 0.13
Luminarias 7.0 10 3 0.21
Σ Total 2381.7 3.88
panel Hiku CS3W-390 Solis mini 4G Series Inverter
10.42 A Max. DC Input power = 1.2
10.98 A Max . DC Input = 600
Max. Input current per MPPT = 11
Start Voltage = 60

Potencia fotovoltaica [kW] = 0.70 Sobre dimensionamiento = 21%


Cantidad de paneles = 2
Potencia FV Max = 0.85
Arreglos de paneles
Serie
Voltaje = 99.48
Corriente = 10.98
Paralelo
Voltaje = 47.4
Corriente = 23.0
i 4G Series Inverter
kW Rated output power (kW) = 0.7
V
A
V
Datos de JKM-550M-72HL Sunny
Pmax = 550 W Imp = 13.45 A Max. DC Input Voltage =
Vmp = 40.9 V Isc = 14.03 A Max . DC Input Current =
Voc = 49.6 V Max. Short-Current DC =
Start Voltage =

Potencia efectiva [MW] =


Cantidad de paneles =
Potencia FV Max =
Arreglos de paneles
Serie
Max. DC Input Voltage =
Voc =
Paralelo
Max. Input short circuit current =
Isc =

Combiner Box

Sunny
Max. DC Input Voltage =
Max . DC Input Current =
Max. Short-Current DC =
Start Voltage =

Arreglos de paneles
Serie
Max. DC Input Voltage =
Voc =
Strings
Max. Input short circuit current =
Isc =

Cantidad de paneles =
Potencia FV Max =
Sobredimensionamiento =

Combiner Box 16
Max.Current per Input (A) =
Max.number of inputs strings =
Cantidad de combiners =

Cable para entrada de cada combiner


Amperaje =
Factor de seguridad =

Sunny Central 2800 UP-US


Interruptor 3000 A 3P
Cable 12 AWG XLPE-PV 300m
Cable 250MCM XLP 200 m x 2 x 13
Cable 4 AWG THHN 1,300 m
Cable 750 MCM THHN 500m x4
Cable 1/0 THHN 100m
Combiner box 16 x13
Panel JKM-550M-72HL 6000 x 216
Estructura metalica
Transformador 2800 kVA 600/23kV
Total para 2.8MW
Total para 8.4MW
Sunny Central 4200 UP-US
1500 V Rated output power (kW) = 4200
4750 A
8400 A
891 V

8.40E+06 Potencia efectiva x Inversor 2.80E+06


18138
9.98E+06 Sobre dimensionamiento = 19%
os de paneles

1500
30
49.6
Strings Serie V
8400 200 30 1488
600
14.03 200 30 1488
199 30 1488

Analisis para un Inversor con potencia de salida de 2800

Sunny Central 2800 UP-US


1500 V Rated output power (kW) = 2800
4750 A
6400 A
891 V

os de paneles
Calculado Ajustado
1500 A V
30 30
49.6 2806 1488

6400
456 200
14.03

6000
3.30E+06
18%

biner Box 16
17.2 13 Combiners
16 16 Strings per Combiner
13 14 A

da combiner
224
1.5

$ 20,000.00
$ 8,434.43
$ 2,724.00
$ 126,246.74
$ 5,629.00
$ 127,657.48
$ 945.00
$ 71,500.00
$ 1,290,600.00
$ 100,000.00
$ 200,000.00
$ 1,953,736.65
$ 5,861,209.95
A #Paneles MW DC Sobredimensionamiento
2800 6000 3.30E+06 18%
2800 6000 3.30E+06 18%
2800 5970 3.28E+06 17%
17970 9.88E+06