Professional Documents
Culture Documents
User Manual
01
Product Name and Specifications
Power adapter
HEPA filter
Base
Model KJ320
AC Voltage AC 100V-240V
CADR 320m³/ h
Noise 58dB
N.W. 4 . 2kg
02
Important Satety Tips
Please read this instruction manual carefully before use and keep it for future reference.
When we use electrical appliances, we should have the most basic safety knowledge to avoid
fire, electric shock and other injuries. Therefore, please follow the instructions below
Do not use the machine without Do not use outdoors or when the
the filter installed. doors and windows are open.
Do not use the air cleaner in places If the power cord is damaged,it
that are exposed to moisture or must be replaced or repaired by
water splash,such as bathroom, the manufacturer or its authorized
kitchen,beside the sink or service network and maintenance
basement that is serious damp. personnel in order to avoid danger.
03
Important Satety Tips
Move
1. When moving, be sure to stop the host and pull out the power plug.
2. Hold the clamp on the side of the main engine to avoid excessive vibration or falling.
Install
1. Do not start the host in case of danger.
2. The distance between the center of the main machine and the wall and other occlusions should be
more than 50cm.
AC power cord
1. Use the power adapter and socket as indicated below to avoid fire,shock or damage.
2. Please use only the supplied power adapter and do not use any other brand of power adapter.
3. Disconnect the adapter's power cord from the ac socket before performing maintenance or moving
the air purifier.
04
Operating Instructions
This product is not recommended for users with physical, sensory, mental abilities,
experience or lack of knowledge.Use (including children), except under the
supervision or direction of the person responsible for its safety.
ATTENTION
Children should be supervised to ensure that children do not play with electrical
appliances.
If the product needs to be shut down during use, please press the "Power" button
on the control screen to shut down normally and then pull out the Power. Abnormal
Power failure may cause product failure.
Plug-in operation
Make sure the machine is level on a level surface so that the bottom microswitch is pressurized.
When the power is plugged in, the air purifier will sound "B", all the indicators will light off after 0.5
seconds, and the air purifier will enter the standby state.
Power on/off
Press ( ), the air purifier will sound “B”, the machine will run in automatic gear, the wind speed
will be adjusted according to the air quality; press ( ) again, the machine will stop running and
return to the standby state.
05
Operating Instructions
Wind speed
Touch ( ) to adjust the wind speed of the machine. The higher the speed, the higher the wind
speed.
Timing setting
Press ( ), the machine enters the timing setting, and displays 1H, 2H, 3H 12H to set the machine
off time.At 12H, press ( ) again to cancel the timing.If the child lock function is started in the
regular state, the machine can be started only after it is unlocked after being closed.
Child lock
Press and hold for 3 seconds ( ) to turn the child lock function on or off. When the child lock
function is activated, touching other buttons is invalid.
Filter reset
When the machine runs for a certain period of time, the Filter will flash in red. At this time, you
should replace it with a new filter. Press and hold for 3 seconds ( ) to clear the accumulated
time and the Filter stops flashing.
Special reminder: if the filter is replaced before the indicator light of the filter is on, the filter timer
will not be reset, and continue to calculate the life of the last filter. As a result, the filter replacement
light may soon be bright red.
Sleep Mode
Press ( ), the machine goes to sleep, except the light is on, the other lights are off. In this mode,
the wind speed runs in the first gear. When the sleep button is touched again, it returns to the last
running state. In the sleep state, other buttons are invalid.
Automatic Mode
When the machine is running in automatic mode, the machine will adjust the wind speed, the color
of the LED light according to the air quality.
A. Green: Good air quality, 0≤PM2.5≤70.
B. Blue: The air quality is normal, 70<PM2.5≤150.
C. Red: The air quality is poor, 150<PM2.5≤500.
When 0 ≤ PM2.5 ≤ 50, the fan motor operates in one gear.
When 50 < PM2.5 ≤ 100, the fan motor operates in the second gear.
When 100 < PM2.5 ≤ 150, the fan motor operates in third gear.
When 150 < PM2.5 ≤ 200, the fan motor operates in the fourth gear.
When 200 < PM2.5 ≤ 500, the fan motor operates in five gears.
06
Filter Reset Guideline
1. Disconnect the power 2. Rotate the bottom cover 3. Take out the filter.
and turn the machine counter clockwise, loosen
upside down. the bottom cover and
remove it.
4. After removing the new 5. Install the bottom cover 6.Turn the machine around.
filter from the bag,loaded and lock it clockwise.Turn
inside the machine. the machine around.
07
Common Trouble Shooting
Excessive product Are all packages of the filters Ensure that all packages
sound removed? have been removed.
Move the machine to a clean
room, if the red light is still
The air quality Is there unfound dust or peculiar always on, the sensor line
indication is always smell inducing substance indoors? may be abnormal.
red. Please contact the customer
service center.
The air quality Set to auto mode.The air
indicator light is always volume will not be changed
red/blue/green, but Is it in auto mode status? automatically in manual wind
the air volume is still speed mode.
unchanged.
08