You are on page 1of 3

AS 3894.

11-2002

Australian Standard"'

Site testing of protective coatings

Part 11: Equipment report


SITE TESTING OF PROTECTIVE COATINGS

EQUIPMENT REPORT
PROJECT DATE
r
SITE CONDITIONS [ ]

WORK AREA: Totally enclosed [ ] Roofed [ ] Fully exposed [ ]

Clean [ ] Dusty [ ] Sealed floor [ ] Well ventilated [ ]

Cramped access [ ] Clear access [ ] Marine, on-shore [ ] Marine, offshore [ ]

Ground l evel [ ] Height [ metres] Scaffold required [ ] Hazardous [ ]

TEST EQUIPMENT

DATE STANDARD
TEST REQUIREMENT TYPE / MODEL CALIBRATED AGAINST
REFERENCE STANDARD

ABRASIVE BLAST STANDARD-AS 1627.4

PROFILE-AS 3894.5

WET FILM THICKNESS-AS 3894.3

DRY FILM THICKNESS-AS 3894.3

DEWPOINT/HUMIDITY-AS 3894.7

ADHESION TESTING-AS 3894.9

HARDNESS-AS 3894.4

CONTINUITY TESTING-AS 3894.1

OTHER

METHOD OF A PPLICATIO N [ V]

Brush [ ] Roller [ ] Conventional spray [ ] Airless spray [ ] Plural spray [ ]

SPRAY EQUIPMENT

Airless pump [ ] Pressure pot [ ] Continuous agitator [ ] Water trap [ ]

Model

Gun Tipsize Needle Aircap

AIR SUPPLY ABRASIVE BLAST CLEANING SPRAY APPLICATION

COMPRESSOR BRAND/MODEL

CAPACITY

AIR PRESSURE Single pot Pressure pot

Double pot Airless pump

Blast nozzle Gun

Water trap fitted [ ] Condensor fitted [ ] Filter fitted [ ]

REMARKS Signed

. . . ................................................................................................................ On behalf of

. . . ................................................................................................................ Date
Site testing of protective coatings

EQUIPMENT REPORT

This Report was prepared by the Australian members of the Joint


Standards Australia/Standards New Zealand Committee CH-003, Paints
and Related Materials, as a quality control record of equipment used to
apply protective coatings to supersede AS 3894.11-1993.

The Report is suitable for use by paint applicators, coating suppliers,


i nspectors, project managers and specifiers who have undertaken work
i n such diverse fields as mining, energy and power, water, oil and gas,
transport and food.

This Report form may be used as a quality control document to record


details as required by the Painting Contractors Certification Progam
( PCCP) and AS/NZS ISO 9000.

The Report should be used in conjunction with AS 3894.10 and


AS 3894.12.

The listing of equipment conditions that apply at the time of application


will assist when reviewing the coating system's performance at a future
date.