You are on page 1of 6

1100 ELEGANCE/ALLIANCE CLASSIC

REMOTE CONTROL 915Mhz [2,4 Ghz]


INSTRUCTIE - INSTRUCTION - ANLEITUNG - INSTRUCTION 11P00319, Revision O
[1]The remote controls on this lift function
GREEN: RF-2.4Ghz
BLUE: RF-915Mhz D E F on 915 Mhz or 2,4 Ghz.
The green button on the remotes is for
up{A}. The red button on the remotes is
for down{B}.
A
If the lift has more than 2 charge [stop]
points the lift will stop on every charge
B [stop] point. This will be when calling and
when sending the lift. If you keep pushing
the button on the remote, the lift will restart
after 3 seconds. The lift does not have
the easy call function. The chair when
operated by the remotes will not swivel on
intermediate floors.
The printed circuit has a mainboard{F},
a receiver board{D} and an adapter
board{E}.
Linking of the remotes
172001.52069 S 2.4 Ghz SP000800 The remotes are standard linked to the
lift out of the box. The light on the receiver
1 172001.52082 S 915 Mhz SP001901 board lights up green as soon as the
batteries are connected.
If the remotes are not linked yet (LED
LINKING

!
in remote control is blinking green),
follow this procedure for linking:
[2]Disconnect the batterie.
[3]Wait for 30 seconds.
[4]Reconnect the batterie.
[5]Press a button on the remote control.
[6]If the light on the remote control becomes
solid green, the remotes are linked{A}.
If the light on the remote control does not
stop blinking after 3 seconds{B} and the
light on the receiver board is also blinking{C},
it is necessary to change the dipswitch
setting to another channel. The reason
might be that an interfering signal is
close to the remotes.
For changing of channels, see picture 8
30 sec 1 of 4

2 3 4
BLINKING GREEN C
VERT CLIGNOTANT

3s
sec ec
3
A SOLID GREEN
VERT SOLIDE
B BLINKING GREEN
VERT CLIGNOTANT

5 6
1100 ELEGANCE/ALLIANCE CLASSIC

REMOTE CONTROL 915Mhz [2,4 Ghz]


INSTRUCTIE - INSTRUCTION - ANLEITUNG - INSTRUCTION 11P00319, Revision O
[7]You can check the remotes: [9]Remove the blue covers (915 Mhz) or the
A first push the red button of the remote and the green covers (2.4 Ghz) on the backside of the
B lift should go down{A}. Push the green button
and the lift should go up{B}.
remotes{A}. Set the dipswitches{B}(note: pay
attention to the position of the word “on”
as this is not always on the same position).
Changing channel Reinstall the covers{C}. [10]Remove the lower
[8]If there is more than one lift in the range of cap of the receiver board housing{A}. Set the
the remotes{A} or otherwise interference {B}, dipswitch on the board{B}. [11]Reinstall the
you can set the remotes on a different channel. cap on the receiver board housing. [12]Relink
7 There are four channels. the remote controles (see illustration 2-6).

CHANGING CHANNELS
A
2 C
1 <50 m
4 POSSIBLE POSITIONS
B

A C
B

8 9

11 2 of 3

Relink the remote controls:


SEE fig. 2 - 6
10 12
1100 ELEGANCE/ALLIANCE CLASSIC

REMOTE CONTROL 915Mhz [2,4 Ghz]


INSTRUCTIE - INSTRUCTION - ANLEITUNG - INSTRUCTION 11P00319, Revision O
PROBLEM SOLVING

!
[13]Problem: the remotes don't function;
blinking GREEN they are showing a blinking green light.
[14]Cause 1: the remote can be too far
away from the lift.
>50 m
[15]Cause 2: possibly the dipswitch set-
tings on the remote is not the same as
the dipswitch setting on the board{A}.
13 14 Solution: change the dipswitch settings:
see illustration 8{B}.

[16]When a button is pressed, and the


red light (located below the green light)
will be lit, you will know the batteries
are close to running out: replace the
batteries (two AA batteries) in your
remote control.
[17]Remove the back panel by slightly
pressing the recess in the cover and
sliding the cover downwards{A}. Remove
the old batteries by pulling the ribbon{B}.
Replace the ribbon across the housing.
Fit the new batteries on top of the ribbon.
The batteries should match the + and -
symbols on the battery label at the bottom
A B GO TO of the battery compartment{C}.
15 FIG. 8 3 of 4

BATTERY LOW POWER


RED light
RECHARGEABLE

B
A

16 17
EN Projectnr...................................... *11P00394*
11 P 0 0 3 9 4 _rev.L

INSTALLATION TEST/EXAMINATION EXPLANATION USE


1 Description of installation
Location: Manufacturer:

2 Rail

3) Confirm that the endstops are fitted in the correct position

3 Electrical drive unit tests

4 Clearance dimensions
1) Confirm the safety distances to obstacles are respected
2) Confirm that there are no open bannisters

5 Mechanical tests

[1.1 x max.load]
10) Confirm that other users can safely use the stairs
(instal support brackets if necessary)
11) Confirm that the stairs can withstand 100 N/cm2
12) Confirm all torque settings have been applied

6 Electrical tests
a)
b)
c)

7 Declaration engineer
I/We certify that on .................I/we thoroughly examinated this lift and that the foregoing is a correct
report of the result.
I/We declare that the erected stairlift is compound with approved components and installed according
to the instructions in the installation manual. I/We also declare that I/we have instructed the user by
telling him/her all users practice. The user is independently able to use the lift safely without further
instruction.The user manual has been handed over to the user.
Name Engineer: ................................................................. Name Engineer: .................................................................
Qualifications: ................................................................. Qualifications: .................................................................
Signing date: ................................................................. Signing date: .................................................................

Signature: ................................................................. Signature: .................................................................


Adress: If employed by a company/association>name/adress:

8 Declaration instructed person


Herewith confirms the user of the stairlift that the above mentioned engineer(s) has declared all
users practice and that he/she is known with the complete operation as instructed person.

Name : ................................................................. Adress: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

City: ................................................................. Phone number: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Signing date: ................................................................. Signature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Keep a filled in and signed form with the installed lift.