You are on page 1of 20

Oxygen Bubble Facial Beauty Machine

Model:W9

USER MANUAL
Preface
Thank you for choosing the instrument designed and manufactured by our company. In

order to better exert the effect of the product, we sincerely recommend:

 Before using the instrument, please read this instruction carefully and keep it for future

reference.

 Please install, use and operate correctly according to the requirements in the instructions.

 Do not disassemble or modify any parts of the machine.

 Except the authorized personnel of our company, it is strictly forbidden for others to open

the cover and disassemble the host.

 It is strictly forbidden for non-professionals to carry out maintenance and transformation

without authorization.

 If you encounter any difficulties during the operation, please contact us.
1、Product Introduction

Oxygen bubble facial beauty machine is a multi-functional skin care instrument that combines

multiple energies with significant clinical effects; it is an indispensable basic beauty instrument

in skin management projects.

2、Application

 Hydro Dermabrasion Cleaning:Deep skin cleansing, removing oil and black acne

 Nano spray:Atomized liquid, osmotic replenishment

 Ion clamp:Sterilize, inhibit inflammation, acne removal, improve oily skin

 Iontophoresis:Introduction of nutrients, open pores and promote absorption

 Two stage RF:Lifting and firming, removing anti-aging, and proliferating collagen

 Eye ultrasound : Introduce eye nutrition, improve fine lines and wrinkles, and enhance

firmness

 Face ultrasound : Introduction of facial nutrition, improve fine lines and wrinkles, and

enhance firmness

 Hot & Cold hammer : heat is introduced to promote the absorption of essence; it calms the

skin and shrinks capillaries

 Ion clamp:Accelerate blood circulation and promote the absorption of mask essence

3、Technical Parameters

Ion frequency:65Khz

RF frequency:1Mhz

Ultrasonic frequency:1Mhz

Hot and cold temperature: -2--5°C;40--50°C


Display screen:10.4 inch color touch screen

Output Power:250W

4、Equipment introduction

Operating handle
Air regulating valve
Display screen
Water regulating valve

Handle hanger
Handle

Liquid bottle

Indicator light

Casters
Handle socket

Vents
Waste bottle

Filter Water injection hole

Drain hole
Power outlet
Power switch Overflow hole

① Operation handle:There are a total of 8 operating handles and 1 set of ion clamps, which are

respectively placed in the handle holders of the corresponding size;

② Air regulating valve:Knob for adjusting the suction power of the water;

③ Water regulating valve:Knob for adjusting the flow rate of clean water (original solution);

④ Handle hanger:There are 2 different sizes and specifications, a total of 8;

⑤ Liquid bottle: There are three clean liquid bottles A, B and C;

⑥ Indicator light: After the instrument is powered on, the indicator light is on;

⑦ Handle socket: There are 9 handle sockets in total, each socket has a corresponding handle

graphic;

⑧Waste bottle: The water mill cleans the waste bottle. After each operation, the waste water
must be discarded in time to clean the bottle; when the water is full, there will be an alarm on

the display. When installing the waste bottle, pay attention to its tightness, otherwise there will

be insufficient suction.

⑨ Filter: When operating the water mill cleaning and nano-spray functions, filter the impurities

in the gas; pay attention to its tightness when installing, otherwise there will be insufficient

suction or insufficient spraying power. The stagnant water in the filter bottle should be cleaned

up on schedule to avoid sucking in the air pump when the water is full, which may cause the air

pump to age easily.

5、Machine List

Machine:1 set

Hydro Dermabrasion Cleaning handle:1Pcs(Contains 3 soft heads, 3 hard heads, and 2 frosted

heads)

Nano spray handle:1Pcs

Plasma handle:1Pcs

Iontophoresis handle:1Pcs

Eye ultrasound handle:1Pcs

Face ultrasound handle:1Pcs

Hot & Cold hammer: 1Pcs

Ion clamp:1Pcs

Two stage RF: 1Pcs

Handle hanger:8Pcs
Power Line:1Pcs

Manual:1Pcs

Please check whether the accessories are complete according to the instrument list immediately

after unpacking. If you find any missing or damaged items, please contact our company within

24 hours.

6、Machine installation

6.1 Hanger installation

There are two raised card positions on the rack, press down on the base of the upper rack to

snap into the slot of the base, and insert the rack in order

6.2 Handle installation

Connect the handles to the corresponding handle sockets respectively, and then put the

handles into the hangers;

6.3 Add water to the instrument

Screw the water injection funnel to the hot and cold skin care water injection port, open the

cold and hot skin care overflow port sealing cap, add water until water flows out of the cold and

hot skin care overflow port, stop adding water;

Note: The sealing caps of the water injection port and the overflow port are to prevent

the residual water stains from flowing out of the instrument during the transportation

of the instrument; however, it is forbidden to screw on the sealing caps of the water

injection port and the overflow port when the instrument is working, otherwise it will

affect the water circulation and cause Too high water temperature can easily burn the
handle.

6.4 Load the stock solution

Put the original solution into the original solution bottle according to the dilution ratio

6.5 Instrument debugging

Check if the handle is connected properly

Check whether the waste bottle and air filter are installed in place

Plug in the power cord, turn on the power switch, and power-on test;

7、Instrument operation

7.1 Turn on the instrument and enter the function interface

7.2 By clicking the button ,Move the operation handle and click the middle handle icon

to enter the operation interface; or long press the switch button on the operation handle to

directly enter the operation interface;


① Hydro Dermabrasion Cleaning operation

Handle indicator
Handle switch

Cleaning tip

Water temperature

Water temperature adjustment

Time adjustment
Liquid bottle toggle button

Back Start / Standby


② Nano spray operation

Nutrition bottle

Handle indicator
Handle switch

Time adjustment

Back Start / Standby


③ Plasma Operation

Handle indicator
Handle switch

Time adjustment Energy regulation

Back Start / Standby


④ Iontophoresis operation

Nutrition bottle

Handle indicator
Handle switch

liquid outlet

Water output adjustment


Time adjustment Energy regulation

Mode regulation

Back Start / Standby


⑤ Two stage RF operation

Handle indicator
Handle switch

Energy regulation
Time adjustment

Mode regulation

Back Start / Standby


⑥ Eye ultrasound operation

Handle indicator

Handle switch

Time adjustment Energy regulation

Mode regulation

Back Start / Standby


⑦ Face ultrasound operation

Handle indicator
Handle switch

Time adjustment Energy regulation

Mode regulation

Back Start / Standby


⑧ Hot & Cold hammer operations

Handle indicator

Handle switch

Hot and cold indicator

Temperature display

Temperature adjustment

Time adjustment
Heating button
Cooling button

Back Start / Standby


⑨ Ion clamp operation

Ion positive electrode

Ion negative electrode

Mode regulation

Time adjustment Energy regulation

Back Start / Standby


8、 Taboo people

 Not to be used for serious diseases such as heart disease, high blood pressure, diabetes,

gastric ulcer, etc.;

 Not to be used by pregnant women and patients with epilepsy;

 Not to be used by patients with contact dermatitis;

 Not to be used for bleeding disorders or trauma;

 Customers who are taking antioxidants or hormone drugs are not allowed to use。

9、Precautions

9.1 Cleaning and maintenance

 The operating handle must be cleaned immediately after use, and the waste bottle liquid

must be drained; the power must be turned off when cleaning the instrument。

 When the instrument is not in use, it should be placed in a ventilated and dry place, and the

top of the instrument should be covered with a dust cover。

9.2 Safe handling

 The instrument has precision components in memory, users should try not to move them

long distances。

 The water in the original liquid bottle and waste bottle must be poured out before

transporting the machine;

 Remove the handle and put it in the handle packing box;

 The shock-absorbing packaging provided by the original manufacturer must be used

during transportation。

9.3 Electrical Safety


The instrument has built-in precision components. Do not disassemble or disassemble the

instrument privately. There is high voltage in the operating time. After the power is turned off,

the high voltage components may still have residual voltage. Open the case at will, there is a

danger of high voltage electric shock!

9.4 Operational safety

 You must fill up with water before starting up, otherwise the treatment hand tools will be

burned! And use purified water or medical distilled water.

 Check the circuit and waterway of the instrument immediately after turning it on, and

always observe the safety of the circuit and waterway during the entire operation.

10、Repair and service

10.1 This instrument has a 12-month warranty for the main unit and 3 months for the handle

from the date of purchase (by receipt); during the warranty period, the instrument malfunctions

(non-human phenomena) are repaired free of charge. If the warranty period expires, you can

also be responsible for repairs, and charge the cost of spare parts and consumables in

accordance with the company's regulations (transportation costs are borne by the customer). If

you need to add or purchase, please contact our company.

10.2 Free maintenance and warranty services are not provided for failures caused by the

following users’ personal reasons:

 Failure caused by unauthorized disassembly or modification of this product;

 Failure caused by the use of operating handles not delivered by our company;

 Failure caused by careless use, beating, or falling;

 Failure caused by lack of reasonable maintenance;


 Failure caused by correct use not in accordance with the instructions for use。

10.3 Product Warranty

Warranty Card

Product Name Customer Name

Model Number Contact Number

Purchase Date Contact Address

Repair Date Cause Of Issue Repair Content Maintenance Staff

You might also like