Model:W9
USER MANUAL
Preface
Thank you for choosing the instrument designed and manufactured by our company. In
Before using the instrument, please read this instruction carefully and keep it for future
reference.
Please install, use and operate correctly according to the requirements in the instructions.
Except the authorized personnel of our company, it is strictly forbidden for others to open
without authorization.
If you encounter any difficulties during the operation, please contact us.
1、Product Introduction
Oxygen bubble facial beauty machine is a multi-functional skin care instrument that combines
multiple energies with significant clinical effects; it is an indispensable basic beauty instrument
2、Application
Hydro Dermabrasion Cleaning:Deep skin cleansing, removing oil and black acne
Two stage RF:Lifting and firming, removing anti-aging, and proliferating collagen
Eye ultrasound : Introduce eye nutrition, improve fine lines and wrinkles, and enhance
firmness
Face ultrasound : Introduction of facial nutrition, improve fine lines and wrinkles, and
enhance firmness
Hot & Cold hammer : heat is introduced to promote the absorption of essence; it calms the
Ion clamp:Accelerate blood circulation and promote the absorption of mask essence
3、Technical Parameters
Ion frequency:65Khz
RF frequency:1Mhz
Ultrasonic frequency:1Mhz
Output Power:250W
4、Equipment introduction
Operating handle
Air regulating valve
Display screen
Water regulating valve
Handle hanger
Handle
Liquid bottle
Indicator light
Casters
Handle socket
Vents
Waste bottle
Drain hole
Power outlet
Power switch Overflow hole
① Operation handle:There are a total of 8 operating handles and 1 set of ion clamps, which are
② Air regulating valve:Knob for adjusting the suction power of the water;
③ Water regulating valve:Knob for adjusting the flow rate of clean water (original solution);
⑥ Indicator light: After the instrument is powered on, the indicator light is on;
⑦ Handle socket: There are 9 handle sockets in total, each socket has a corresponding handle
graphic;
⑧Waste bottle: The water mill cleans the waste bottle. After each operation, the waste water
must be discarded in time to clean the bottle; when the water is full, there will be an alarm on
the display. When installing the waste bottle, pay attention to its tightness, otherwise there will
be insufficient suction.
⑨ Filter: When operating the water mill cleaning and nano-spray functions, filter the impurities
in the gas; pay attention to its tightness when installing, otherwise there will be insufficient
suction or insufficient spraying power. The stagnant water in the filter bottle should be cleaned
up on schedule to avoid sucking in the air pump when the water is full, which may cause the air
5、Machine List
Machine:1 set
Hydro Dermabrasion Cleaning handle:1Pcs(Contains 3 soft heads, 3 hard heads, and 2 frosted
heads)
Plasma handle:1Pcs
Iontophoresis handle:1Pcs
Ion clamp:1Pcs
Handle hanger:8Pcs
Power Line:1Pcs
Manual:1Pcs
Please check whether the accessories are complete according to the instrument list immediately
after unpacking. If you find any missing or damaged items, please contact our company within
24 hours.
6、Machine installation
There are two raised card positions on the rack, press down on the base of the upper rack to
snap into the slot of the base, and insert the rack in order
Connect the handles to the corresponding handle sockets respectively, and then put the
Screw the water injection funnel to the hot and cold skin care water injection port, open the
cold and hot skin care overflow port sealing cap, add water until water flows out of the cold and
Note: The sealing caps of the water injection port and the overflow port are to prevent
the residual water stains from flowing out of the instrument during the transportation
of the instrument; however, it is forbidden to screw on the sealing caps of the water
injection port and the overflow port when the instrument is working, otherwise it will
affect the water circulation and cause Too high water temperature can easily burn the
handle.
Put the original solution into the original solution bottle according to the dilution ratio
Check whether the waste bottle and air filter are installed in place
Plug in the power cord, turn on the power switch, and power-on test;
7、Instrument operation
7.2 By clicking the button ,Move the operation handle and click the middle handle icon
to enter the operation interface; or long press the switch button on the operation handle to
Handle indicator
Handle switch
Cleaning tip
Water temperature
Time adjustment
Liquid bottle toggle button
Nutrition bottle
Handle indicator
Handle switch
Time adjustment
Handle indicator
Handle switch
Nutrition bottle
Handle indicator
Handle switch
liquid outlet
Mode regulation
Handle indicator
Handle switch
Energy regulation
Time adjustment
Mode regulation
Handle indicator
Handle switch
Mode regulation
Handle indicator
Handle switch
Mode regulation
Handle indicator
Handle switch
Temperature display
Temperature adjustment
Time adjustment
Heating button
Cooling button
Mode regulation
Not to be used for serious diseases such as heart disease, high blood pressure, diabetes,
Customers who are taking antioxidants or hormone drugs are not allowed to use。
9、Precautions
The operating handle must be cleaned immediately after use, and the waste bottle liquid
must be drained; the power must be turned off when cleaning the instrument。
When the instrument is not in use, it should be placed in a ventilated and dry place, and the
The instrument has precision components in memory, users should try not to move them
long distances。
The water in the original liquid bottle and waste bottle must be poured out before
during transportation。
instrument privately. There is high voltage in the operating time. After the power is turned off,
the high voltage components may still have residual voltage. Open the case at will, there is a
You must fill up with water before starting up, otherwise the treatment hand tools will be
Check the circuit and waterway of the instrument immediately after turning it on, and
always observe the safety of the circuit and waterway during the entire operation.
10.1 This instrument has a 12-month warranty for the main unit and 3 months for the handle
from the date of purchase (by receipt); during the warranty period, the instrument malfunctions
(non-human phenomena) are repaired free of charge. If the warranty period expires, you can
also be responsible for repairs, and charge the cost of spare parts and consumables in
accordance with the company's regulations (transportation costs are borne by the customer). If
10.2 Free maintenance and warranty services are not provided for failures caused by the
Failure caused by the use of operating handles not delivered by our company;
Warranty Card