You are on page 1of 96

2023

PRODUCT CATALOGUE

Electrical Test & Measurement


Instruments

The Motwane Manufacturing Company Private Limited | Nashik, India


CONNECT
TEST
ANALYSE
Table of Contents 1

Table of Contents

Sr.No. Contents Page No.

1. Digital Insulation Testers


Diagnostic Insulation Tester : 10K PI 8
Diagnostic Insulation Tester : 5K PI 10
Digital Insulation Tester : IT-51 12
Digital Insulation Tester : IT-250G 14
1KV Digital Insulation Tester Cum Multimeter : MIRT-61 16
1KV Digital Insulation Resistance : i-12 19

2. Transformer Testing Instruments


Transformer Winding Resistance Meter : XWRM-25A 21
Transformer Winding Resistance Meter : XWRM-10A 23
Transformer Turns Ratio Meter : XTRM-3 25
Oil Tan Delta & Resistivity Test Set : MOTR 27
Automatic Oil BDV Test Set : OTS 60A/80A/100A 29
Digital Oil BDV Test Set : OTS 60DS/80DS/100DS 31
3. Contact Resistance/Low Resistance Meter
Contact Resistance Meter : PCRM-200S 33
Contact Resistance Meter : PCRM-100S 35
Contact Resistance Meter : PCRM-100SM 37
Contact Resistance Meter : CRM100A 39
Micro Ohm Meter : LR-2065S 41
Micro Ohm Meter : LR-2045S 43
4. Protection Testing
High Vltage Test Set : HVT Series 45
Relay Test Set : MOT - RTS 47
Primary Current Injection Kit : PIK Series 49

5. High Voltage Detectors (33KV/132KV/220KV/400KV) 51

6. Digital Earth Tester 53


Digital Earth Tester : DET 20 55
Digital Clamp on Earth Resistance Tester : DECT - 3 57
Digital Clamp on Earth Resistance Tester : DECT - 2
7. Digital Multimeter
59
Digital Multimeter : M63
63
Digital Multimeter : M65
8. Digital Clamp Meter
67
Digital Clamp Meter : DCM49A
70
Digital Clamp Meter : DCM 30A
73
Digital Clamp Meter : DCM 39A/9930A

9. Motware Cloud Application


76

10. Cable Fault Locator (Telemetrics)


Different Types of Cable Network LV 78
Surge Tester 79
HV Surge Tester 80
Surge Receiver 81
High Voltage Combo Surge Test Sets 82
High Voltage Test Sets 83
Cable Route Tracer 84
Associated Equipments 85
Cable Fault Pre-Locators Combined 86
Systems 88
Trolley Mounted Systems 89
Other Products 90
Van / Trailer Systems 92
Company Profile 2

Over Hundred Years of Progress

Motwane is an Indian engineering company with an To be collaborative, curious, and authentic are the core
impressive legacy and a strong focus on R&D and IoT values that have been part of Motwane’s success story from
capabilities Its products, ranging from power plants to the start.
plug points, and surpass existing quality standards, are
synonymous with robust, reliable, and long-last What Make Motwane Unique ?
performance.
Pioneers
As a result, the Motwane brand has earned the trust of
clients over the last 100 years with its innovative, energy- We are innovators in the design and manufacture of high-
efficient, and user-friendly solutions. performance, high-precision electrical Test & Measurement
equipment.

Innovation
We create innovative IoT technologies and digital offerings
that are designed to boost productivity, efficiency, energy
saving, proactive decision making, and help our customers
to take a step towards a green, more sustainable future

R&D Facilities
We work in world-class R&D facilities in which all of
Motwane’s products and solutions are indigenously
designed by over 40 technologists. Maybe not world class?

Global Distribution Network


We have built a strong global distribution network with a
presence in more than 50+ countries, catering to the needs
Motwane’s spirit of innovation has not only transformed an of users across segments, such as EPC, Power, Railways,
entire industry, but also quietly keeps cities running and Certification Labs, Defence, Oil & Gas, Steel & Metal,
street lights shining while you sleep. Automobiles, Process Industries, and the MSME sector, in
addition to contractors and OEMs
The company’s global growth, and further innovative
ventures as part of its green initiatives are guided under Production
the aegis of Motwane’s forward-thinking leadership, who We offer a diverse product line, encompassing low voltage
are committed to creating opportunity and always going solutions for general industrial applications, specialized
the extra mile for our clients, partners, and employees, so products for high voltage applications, IoT-based intelligent
together we can engineer a better future for the world. street lighting solutions, advanced security solutions, and
digitized testing software

Our Journey
Our Legacy 3

A Legacy of Innovation
We are committed to taking the
Motwane was one of the earliest manufacturing
passion Mr. Nanik Motwane showed
companies during the time of the British Raj.
in the early days of the company
Inaugurated in 1909, Motwane started out
from a patriotic past into the
pioneering the mass medium of radio, and from
digital future.
then on, the firm’s history has been tightly
interwoven with the history of India. In 1929, 18
years before Indian Independence in 1947, the The bottom line of hope
Freedom Movement led by Mahatma Gandhi was
Motwane strives to continue to leave a mark on Indian
well under way. Motwane’s Managing Director at history – within the country’s boundaries and abroad - and
the time, Nanik Motwane, recounts: to help shape the next generation of engineers to
successfully tackle the challenges of tomorrow. Driven by
“ I saw Gandhi-ji going from insatiable curiosity, and the will to never give up, we work
platform to platform to
hard to create digital and physical spaces where we can
address meetings at one
turn dreams into realities. Our hope lies in being able to
and the same place, to
enable his weak voice to be predict the future by learning from the past, live in
heard by large numbers. It harmony with nature and each other, and to use the
was then that I felt that I advancements of technology and our capacity as
must find some means to
‘machine whisperers’ to create a safer, more equal, and
amplify his voice. ”
creative world.
Mr. Nanik G. Motwane

His solution: a loudspeaker that effortlessly Prominent Testimonial


carried Gandhi’s and other freedom fighter’s “Sjt. Nainik G. Motwane has been serving the Indian
voices to the masses. One can only estimate how National Congress since 1929 with his loudspeakers. Those
big the impact of Motwane’s patriotic impulse was who have witnessed the huge demonstration of the
Bombay Congress must have vivid recollections of his
on India’s Independence movement. Mr. Nanik’s
admirable arrangements. The Reception Committee will
immediate reaction to solve a problem at hand
not be able to find better arrangements in this line.”
with the help of technology, creating a positive
impact for the greater good, has been the Sardar Vallabhbhai Patel – First Deputy Prime Minister
cornerstone of Motwane’s ethos as a company. of India
Division 4

The last 100 years has seen the company rise to a Industrial & Commercial
significant position across the electrical sector in India and Embracing the global shift towards intelligent, cloud-
abroad, pioneering electrical test & measurement based technologies, Motwane offers efficient solutions
equipment that set market benchmarks for a wide range of that help its clients to take the necessary leap towards a
clients. Motwane’s long-standing commitment to greener future.
innovating products that anticipate future needs has led to
further diversification, and the creation of MOT-WARE, an
IoT-based test data software, AI engines for data
vis u al i s at io n , s m ar t lig ht i n g , a n d o t he r e n e rgy
management solutions.

Electrical
Working closely with our customers enables Motwane to
successfully innovate, design, and engineer future-ready
solutions. For the electrical sector, we have engineered a
variety of high precision test & measurement equipment
that have been industry standard for decades. Our
electrical business is organised into the following two
verticals.
The world is transitioning through a massively changed
Power & Grid technological landscape. There is a global shift towards cloud-
For decades, Motwane’s Test & Measurement product based IoT technologies that have become a part of day-to-day
Operations in intelligent factories, industry 4.0, green
range has helped clients to maintain efficiencies, ensure
buildings, and net-zero, with the remote monitoring of capital
safety, and increase profitability.
equipment through ‘digital twins’.

Responding to this need, Motwane has designed a range of


products that boost productivity, improve efficiency, and save
energy.

Motwane Security Systems


Motwane Security Systems, another business division of
Motwane, offers a range of holistic solutions for a spectrum of
access and entrance control needs.

Power & Grid is an interconnected network that generates,


transmits, and distributes electricity to the consumer.
Without these complex power systems, no cities,
industries, residential complexes, offices, and public
infrastructure would be able to function. Recognizing the
need for resistant, reliable, and high-quality equipment,
Motwane has taken large strides by offering real-time
monitoring, combined with accurate testing capabilities of
power systems.

We have acquired Telemetrics, an established market Visit our website


leader in highly specialised underground cable fault www.motwane.com
locating equipment, to serve global customers in the for more information
power and grid sector.
Global Presence 5

“ Presence in over 45 Countries Worldwide ”

From India to the world


The company's international expansion over the last
decade has contributed to Motwane's growth, and, as a Motwane is Committed to offering
result, strengthened its positioning as an internationally long-term sustainable growth
acknowledged brand. Their robust, innovative, and
constantly evolving product portfolio enables Motwane
to expand their reach into new markets.
Motwane complies with the following global
Constant R&D is one of the driving fundamentals at the
standards and certifications
company. Our diverse global presence empowers
Motwane to build scale efficiency, and through our variety
of project sizes, teams, and locations, we are able to
leverage the world for new knowledge and expertise,
incorporating it in our R&D facilities.

ISO 9001 (2015) QMS (Quality Management


International Clients System)
ISO 9001:2015 is internationally recognised as the world’s
leading quality management standard, ensuring a framework
for continuous improvement of the same within an
organisation.

CE Certification
CE marking is an administrative marking that indicates
conformity with health, safety, and environmental protection
standards for products sold within the European Economic
Area (EEA).
Product & Services 6

Test & Measurement

For more than a century, Motwane has set a benchmark


for test & measurement solutions and pioneered the
development of high-precision equipment across
segments.

Telemetrics Cable Fault Locator


Telemetrics offers a complete range of fault locating
instruments that enable preventive detection and
location of existing defects in power cables,
communication cables, and water pipelines.

MOT-WARE

Emerging from a deep understanding of domain


knowledge, Motwane has designed and developed a
SAAS-based test data platform: MOT-WARE. Creating
the age of ‘Connected Field Service Engineers’, the
software connects electrical test & measurement
equipment to the cloud, and sends asset health data
from devices onto a single, user-friendly dashboard.

IoTx - Online Transformer Monitoring Solution

IoTx is Motwane’s state-of-the-art Transformer


Monitoring Technology that enables any transformer
to become a ‘Smart Transformer’. Our technology is
designed to be a plug & play solution for
Transformers.
Product & Services 7

Motwane AI & Analytics

Motwane’s proprietary AI algorithm users can now


effortlessly predict behavioral patterns of their assets
based on operating conditions. It offers accurate
insights of an asset’s lifespan, leading to better decision-
making, higher efficiency, better CAPEX and OPEX
planning.

IoXn
Motwane built its proprietary IoXn technology, an
easyto- install ‘plug & play’ product, that connects
various assets: transformers, Chillers, Water Meter,
Motors, etc. to the cloud. Enjoy real-time monitoring
and asset management with the magic of one touch
through MOT-WARE.

Smart Street Lighting Solutions

Focused on offering energy-efficient and ROI-driven


solutions in the field of smart lighting, Motwane’s
latest innovation effortlessly illuminates cities,
industries, campuses, and residential projects with
automated lighting.

Motwane Academy
Motwane academy is built to bridge the skill gap and
enable the future of engineers with better
opportunities and technology.
Test & Measurement - 10K PI 8

Features
Available IR Testing with Diagnostic Modes
PI, DAR, DD, Step Voltage, BDV & Burn Test
Programmable Test Voltage from 500V-10KV
Insulation Resistance Range from 1KΩ to 20TΩ
Three Programmable Timers
Programmable Break Down Current Settings
Mains & Battery operation
Internal Data Storage up to 1000 tests*
Galvanic Isolated RS 232 & USB Port
Application Software for Data Trending Analysis
AC/DC voltage measurement up to 600V
Auto Calibration at every start up
Burn Mode for uninterrupted Insulation Resistance Testing
Alarm Mode with Min-Max Settings & Pass Fail Indication
CAT IV 600V, IP54, Complies with latest IEC/IS Standards
Hand Interlock Switch

10K PI
Diagnostic Insulation Tester

CAT IV IP Applications
600V 54
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
10K PI is an Insulation Diagnostic Tester having test voltage range up
resistance quality of an electrical system degrades with
to 10KV, designed & developed indigenously at the state of the art
time, environment condition i.e. temperature, humidity,
R&D laboratory to conduct automatic insulation tests on high voltage
moisture and dust particles. The instrument is designed for
equipment's like Transformers, Cables, Bushings, Switchgears &
routine insulation resistance testing and diagnostic testing
Rotating Machines 10K PI is a microprocessor based instrument
like PI, DD, DAR & SV of high voltage electric apparatus like
deploying the latest technology & very high speed data sampling to
transformers, generators, motors, cables, bushings, LAs,
give correct, repetitive readings & quality performance under harsh
switchgear, etc. and is temperature independent. Trending
electrical conditions. It has a wide insulation resistance range up to
of data can reveal vital information about insulation quality
20TΩ. and enables the user to take informed decision.

Model 10K PI is mains and battery operated portable & compact


insulation tester for outdoor applications. The battery backup of 6
Hours makes it suitable for field operations. IP54 rating keeps 10K PI
safe from water & dust ingress. It complies with CAT IV 600V for safe
operation. The instruments & its accessories are certified as per
relevant IS/IEC standard.

The Information displayed on the large backlit LCD includes


insulation resistance, leakage current, capacitance, battery status &
timer. Three programmable timers are provided to conduct various
tests like Polarization Index (PI), Dielectric Absorption Ratio (DAR),
Dielectric Discharge (DD), Step Voltage (SV), & Breakdown Voltage
(BDV) Test. 10K PI can store up to 1000 test results*. PC interface via
USB & RS-232 for data transfer. The PC software for report generation
& data trending analysis helps to keep records of capital equipment.
Instrument has automatic discharge facility for capacitive loads
discharging The instrument has the automatic discharge facility for
capacitive load discharge at the end of the test.
Test & Measurement - 10K PI 9

Power Supply
Technical Details 10K PI Mains 85V-265V, 50Hz +10%

Battery Type Li-ion Rechargeable Battery

Battery Backup 6 Hours of continuous testing at 10KV

on load of 100MΩ (approx.)


Test Specifications
Battery Charge Time 8 Hours (approx.)
Diagnostic Modes IR, DAR, PI, DD, SV, BDV, Burn Test

Test Voltage Environmental Condition

Voltage Selectable 500V, 1KV, 2.5KV, 5KV, 7.5KV, 10KV Operating Temperature 0℃ to 55℃

Programmable 500V to 1KV in 10 V steps Storage Temperature -20℃ to 70℃

1 KV to 10 KV in 25 V steps Humidity <95% RH, non-condensing

Voltage Accuracy ± 5 % of reading + 5 digit


Safety Standards
Short Circuit Current 3mA
Safety in accordance with EN61010-1
Resistance Range
EMC in accordance with EN61326-1
Analog Display 1 KΩ to 10 TΩ
Type test in accordance with IEC 60068
Digital Display 1 KΩ to 20 TΩ
Test leads in accordance with IEC61010-31,
Accuracy +5% (Upto 999GΩ )
CE & CAT IV600V, IP 54
+10% (1TΩ to 10TΩ )

+20% (10TΩ to 20TΩ ) Mechanical

Programmable Timer T1, T2 & T3 (0-99Min 59sec) Dimension 360mm(L) X 290mm(W) X 210 mm(H)

Current Measurement Weight 5Kg without accessories (Approx)

Range 0-3mA Gross weight 9.3Kg with accessories (Approx)

Accuracy ± 5% of reading + 5 digits


Data Handling & Analysis Software
Voltage Measurement Operated on XP/Windows7/Windows8/Windows10
Range 0-600V AC / DC Two way communication for remote operation
Accuracy ± 8% of reading + 5 digits Report generation along with the graphical representation
Capacitance Measurement for Data Trending Analysis.
Range 1nF to 50µF

Accuracy ± 5% of reading + 5 nF Accessories


Interference Rejection
Standard
1mA RMS per KV test voltage, not exceeding 5mA
3m Test lead set
Memory Mains Power Cord

Internal data storage up to 1000 tests* Instruction Manual


Calibration Certificate
PC Interface
Carry Case
Galvanic isolated USB & RS-232
Optional
Display
15m Test lead Set
Large LCD display with backlit Software CD
RS232 communication cable
USB Cable
Interlock Cable

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - 5K PI 10

Features
Programmable Test Voltage 250 - 5000V in steps of 50V
Insulation Resistance upto 10TΩ
Three Programmable Timers
Modes for conducting IR, Leakage current, PI, DAR,
DD, SV and BDV test
Mains & Battery Operation
CE, CAT-IV 600V, IP65, complies with latest IEC/IS
Standards
1000 test results storage
Optically Isolated RS-232 port & USB port
AC / DC Voltage Measurement
Pass Fail Limit is provided with software generated results
Bluetooth enabled for Motware Mobile App

Connected to Cloud

5K PI
Diagnostic Insulation Tester

CAT III CAT IV IP Applications


600V 600V 65
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
5K PI Insulation Diagnostic Tester is designed to conduct various resistance quality of an electrical system degrades with
diagnostic tests on electrical apparatus like Transformers, Cables, time, environment condition i.e. temperature, humidity,
Bushings, Insulator, Switchgears, Lightning Arrester/Arrestor and moisture and dust particles. The instrument is designed for
Rotating Machines etc. Designed & developed indigenously at the routine and diagnostic testing like IR, PI, DD, DAR & SV of
state of the art, R&D laboratory, the 5K- PI is a microprocessor based high voltage electric apparatus like transformers
instrument deployed with latest technology and very high speed data generators, motors, cables, bushings, LA's, switchgear, etc.
sampling to give correct, repetitive and durable performance under and is temperature independent. Trending of data can reveal
harsh conditions. It is operated through mains and (as well as) the vital information about insulation quality and enables the
battery, weighing less than 5kgs making truly light weight & compact user to take informed decision.
insulation resistance tester for outdoor applications. The instrument
is specially designed to suit operator's ease and test requirement, also
certified as per relevant IS/IEC standards. Instrument has large white
backlit LCD displayed with indication and display test information like
insulation resistance value, test voltage, leakage current, capacitance,
battery status and timer. Equipped with three programmable timers,
which provides to conduct various tests like Polarization Index (PI),
Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Step
Voltage (SV) test and Breakdown Voltage (BDV) test. The instrument
has the automatic capacitive load discharge at the end of the test.

5K-PI has Bluetooth connectivity module with Motware mobile app


for remote access of testing data & in the cloud for further analysis &
record purpose.
Test & Measurement - 5K PI 11

Standards & Approvals


Technical Details 5K PI
Safety In accordance with EN 61010-1

EMC In accordance with EN 61326-1

Type Test In accordance with IS 11994

Ingress Protection IP 65 (closed lead ) IP 40 (open lead )


Test Parameter Specifications
CE & CAT III 600V / CAT IV 600V
Test Regimes (Automatic) IR, Leakage Current, PI, DAR, DD, SV
Safety of Accessories with IEC61010-31
& BDV

Test Voltage 250V - 5KV in 50V steps


Environmental Specifications
Test Voltage Accuracy ± 5% of reading + 5 digit
Operating Temperature 0°C to 55°C
Short Circuit Current 3mA / 5 mA *
Storage Temperature -20°C to 70°C
Three Programmable Timers T1, T2 &T3 (max. 99 min 59 sec.)
Relative Humidity <95% RH, Non condensing
Measurement Ranges
Insulation Resistance Analog Display 1KΩ to 5TΩ
Indications & Annunciations
Digital Range (3 Digit Display) 1KΩ to 10TΩ
Audio visual indication for HV presence
Accuracy (25°C) +(5% + 5 digits)
LED indication for HV presence

Battery status and charging indication


Guard 300KΩ ±10%
Mains / Battery Indication
with 100MΩ Load.

Leakage Current Display Details

Range Up to 3mA / 5mA * Real-time display of Insulation Resistance

Accuracy ± 5% of reading + 5 digit After the end of the test, the result including resistance,

leakage current, time & capacitance information will be


Capacitance
displayed.
Range 10nF to 50µF

Accuracy +10% of rdg.

Voltage Measurement Accessories


Range Upto 600V DC / Upto 600V AC RMS Standard

Accuracy +5% of rdg. 3m Test lead set


Main Power Cord
Power Supply
Mains Protected fuse
AC Mains Voltage 100 - 270V AC Instruction Manual
Frequency 50/60Hz Carrying Bag

Battery Internal Rechargeable Battery Optional

Backup Approx. 6 Hours of continuous 15m Test lead set

testing at 5KV on a load of 10 GΩ RS-232 communication cable


USB Cable
Charging Time 5 Hours (Approx.)
PC Software
Interference Rejection 1mA rms per 250V up to a max of 4mA.
Bluetooth enabled for Motware Mobile App
Physical Specifications
Note : To learn more about the Motware Application, check Page 91
Dimensions 360mm(L) x 290mm(W) x 210mm(H)

Weight 5Kg. (Excluding Accessories)(Approx)

* : Current range 3mA or 5mA supplied as per customer requirement.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - IT 51 12

Features
Selectable Test Voltage from 250V, 500V, 1000V, 2500V,
5000V DC.
Insulation Resistance Measurement up to 1TΩ
Polarization Index Measurement Facility
Short Circuit Current < 2 mA + 0.5 mA
AC/DC Voltage Measurement up to 600V.
Two Programmable Timer from 0 sec to 99 minutes
Liquid Crystal Display with pleasant white backlit.
Internal rechargeable Battery.
Safety - IP 54, CAT IV 600V and CE conformity.
Robust ABS body with self-carrying handle for easy
portability.
Automatic discharge for capacitive circuits.
Guard Terminal to minimize the surface leakage
Pass - Fail Limit

IT 51
5KV Digital Insulation Resistance with Polarization Index

CAT IV IP Applications
600V 54
The Insulation Resistance Test is an essential test that help to
verify the condition of electrical insulation. Insulation
The Motwane IT-51 is a microprocessor based Digital Insulation Tester resistance quality of an electrical system degrades with
designed for testing all types of electrical apparatuses like time, environment condition i.e. temperature, humidity,
transformers, switchgears, motors, generators, cable and substation moisture and dust particles. The instrument is designed for
products. IT-51 has a digital display and an analog arc display. The routine and diagnostic testing like IR, PI of high voltage
instrument automatically performs IR Test and Polarization Index Test electric apparatuses like.
by selecting the mode. IT-51 has a large LCD white backlit display, it
shows leakage current in scrolling form along with IR value and PI All electrical rotating machineries
value. Transformers
HV & LV Switchgears
Insulation Resistance Test : The is an important test for future
comparative purposes, acceptance test and also for determining the Cables

suitability of the electrical apparatus of energizing or application of Insulators etc.


the high-potential (hi-pot) test. The IR test must be successfully
completed for factory warranty to be valid. The IR test must be
conducted immediately prior to energizing the electrical apparatus
or beginning the high potential test

Polarization Index Test : This is an extension of the IR test. In this test,


two IR measurements are taken, the first reading at 1 min and the
second reading at 10 min. Then the ratio of the 10 min reading to 1 min
reading is calculated to give the PI dielectric absorption value. A PI of
winding-to-winding and winding-to-ground should be determined. A
PI value below 2 indicates insulation deterioration and the cause for
further investigation.

IT 51 is designed in light portable instrument for electrical tester and it


has a rechargeable battery operated and AC mains provision for
battery charging. Ingress protection IP54. Instrument has an
automatic capacitive load discharge at the end of the test.
Test & Measurement - IT 51 13

Safety and Standards


Technical Details IT 51
Safety in accordance with : EN61010-1 : 2001

EMC in accordance with EN 61326-1 : 2006

Type Test in accordance with IS 11994

Ingress Protection IP54


Terminal Voltage
Test Voltage 250V, 500V, 1000V, 2500V, 5000V CE & CAT IV 600V

Test Voltage Accuracy ± 5 % of rdg Safety of test lead in accordance with

EN61010-031 : 2002 +A1 : 2008


Short Circuit Current > 2 mA + 0.5 mA

Programmable Timers T1 and T2

Insulation Resistance
Accessories
Analog Display 1 KΩ to 1 TΩ
Standard
Digital Display 1 KΩ to 1 TΩ (3 Digit Display)
Test leads 3 meter : 1 Set
Insulation Accuracy User Manual : 1 No
Up to 1GΩ All Ranges ± (2 % + 2 digits) Calibration Sheet : 1 No
Carrying bag : 1 No
Over 1GΩ 5000V ± (2% + 0.04% per GΩ)
Mains Protected Fuse : 1 No
2500V ± (2% + 0.08% per GΩ)

1000V ± (2% + 0.2% per GΩ) Optional

500V ± (2% + 0.4% per GΩ) Test leads 15 meter : 1 Set

250V ± (2% + 0.8% per GΩ)

AC/DC Voltage Measurement


Range Up to 600V

Accuracy +5% of reading + 5 digits

Polarization index (PI)


Display Range 0 - 99.9

Accuracy +5% of reading + 5 digits

Resolution 0.01

Power Supply Specifications

Battery Internal Rechargeable

Display LCD Display with White Backlit

Mains Power Supply 110/ 230VAC 50/60Hz

General

Dimensions 360 mm(L) X 290 mm(W) X 210 mm(H)

Weight 5.0 Kg (Approx) (without Accessories)

Environmental Specifications
Operating Temperature -10°C to 55°C

Storage Temp -20°C to 70°C

Humidity less than 95% RH, non 0° condensing max

at 40°C

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - IT-250G Spot 14

Features
Selectable Test Voltage from 250V, 500V, 1000V, 2500V,
5000V DC
Insulation Resistance Measurement up to 250GΩ
Short Circuit Current < 1.4 mA. approx
Programmable Timer from 1 sec to 99 minutes
Internal Memory Storage of 1000 readings
Auto Power Off to save battery
Auto Calibration at every start up.
Continuity Testing at 100mA approx.
GUARD Terminal to eliminate surface leakages.
Battery Status Indicator
Safety/EMC CE CAT III (1000V)/ CAT IV (600V), IP54
Shock proof, heavy duty & shrouded test lead
Inbuilt Digital Filter

IT-250G
5KV Battery Operated Digital Insulation Resistance

CAT III CAT IV IP


Applications
1000V 600V 54 The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
resistance quality of an electrical system degrades with
The Motwane has been offering comprehensive range of products
time, environment condition i.e. temperature, humidity,
designed in-house catering multiple segments of power and energy
moisture and dust particles. The instrument is designed for
sector. Digital Insulation ester IT-250G Spot is a micro controller
routine and diagnostic testing like IR of high voltage electric
based battery operated insulation tester for measuring insulation of
apparatuses like
all types of electrical equipments. IT250G Spot has a digital and
analog bar graph display designed for high voltage insulation All electrical rotating machineries
resistance testing in the maintenance and servicing of cables, electric
Transformers
motors, transformers, switchgears and industrial installations. DC
HV & LV Switch gears
insulation tests are performed at 250V, 500V, 1000V, 2500V and
Cables
5000V. Insulation resistance measuring range is 1K Ohm to 250G
Ohm. Auto power off feature enhances the battery life and pleasant Insulators etc.

amber backlit allows user to work in dusk environment also. Industrial Purpose

IT-250G Spot is ideally suited for insulation resistance testing during


erection, commissioning or installation at electrical substations, Accuracy
preventive operation, maintenance and servicing of cables,
transformers at industrial installations. Having robust ABS body , the Accuracy is specified as +(5% of reading + 5 digits) and is

instrument comes with rugged strap which gives easy handling valid at 25°C + 3°C, 55% RH +10%
during transit and also in handling while testing at outdoor sites. The Accuracy is valid from 10% of the range to 95% of the range
guard terminal features minimize the effects of surface leakages and Temp. Coefficient = (0.2% X Specified accuracy) per degree
give error free measurement. Loaded with multiple proposition, centigrade referred to 25°C
IT250G Spot addresses the routine insulation testing need of service Accuracy is not valid if battery status indicator symbol blinks
providers. It also has continuity range for measuring continuity. on display. In this case immediately replace the batteries
Automatic discharge for charged objects is provided and decaying It is recommended that calibration equipment used to verify
discharge voltage is displayed.
the accuracy of the instrument should be 10 times more
accurate
It is recommended to recalibrate the instrument once in year
Test & Measurement - IT-250G Spot 15

Environmental Specifications
Technical Details IT-250G
Operating Temperature 00C to 500 C

Storage Temp -200C to 600 C

Humidity 90% RH at 00 C to 400 C max.


(Non Condensing).
Terminal Voltage
70% RH at 400 C to 500 C max.
Test Voltage 250V, 500V, 1000V, 2500V, 5000V (Non Condensing).

Test Voltage Accuracy ± 10 % of reading + 5 digit


Power
Short Circuit Current <1.4 mA (±0.5 mA ) Approx.
Power Supply 8 X 1.5V AA size Alkaline batteries
Overload Protection 230V DC/AC rms for 30sec
(IEC LR6 )
Insulation Resistance
Power Consumption 40mA approx.
Analog Display 1 KΩ to 250GΩ
Power Consumption YES
Digital Display 1 KΩ to 250GΩ
Auto Power Off After 15 min.

Max. Insulation Accuracy +


Test Voltage Idle sleep mode consumption 400µA approx.(When not in use, always keep the
Resistance (% reading + Digit)
rotary switch at OFF position & remove the batteries from the battery
compartment to save the battery life)
250V 12.5GΩ

500V 25GΩ
Safety and Standards (CE Certifications)
1000V 50GΩ ± (5% + 5)
Safety and Standards (CE Certifications)
2500V 125GΩ Measurement Category : CAT IV (600V) Reinforced insulation

5000V Safety : EN 61010‐1


250GΩ
EMC : EN 61326-1
Notes: Test Voltage Accuracy + (10% + 5) is when tested by using 1000MΩ impedance probe
Motwane Make HV 30/HV 40 or equivalent IP rating: IP 54

Continuity
Accessories
Range Accuracy Overload Protection
Standard
0-200Ω ±(3% + 10) 230V DC/AC rms for 30 sec
Test Lead set (3 mtr. Long shrouded banana with
Buzzer will sound < 20Ω approx.
crocodile clip)
Open circuit voltage on continuity range is 8V approx. Red lead for +ve terminal 1 No.
Black lead for ‐ve terminal 1 No.
Short Circuit current is 100mA approx. on Continuity range w.r.t
Green lead for GUARD terminal 1 No.
GUARD/COM terminal (Battery should be in a full charged condition).
Instruction Manual 1 No.
General Specification Calibration Certificate 1 No.
Carrying Bag 1 No.
Insulation Resistance Measurement Digital & Analog (Bar Graph) indication

Display LCD display with Backlit (90 X 60)mm Optional

Dimensions 230 mm(L) X 165 mm(W) x 95 mm(H) Test Lead set (10 mtr. Long shrouded banana with
Weight 1.5 Kg approx. (without accessories) crocodile clip) 1 No.
Red Lead for +ve terminal. 1 No.
Default Test on time 30 sec.
Black Lead for ‐ve terminal 1 No.
Selectable test time 1 sec. to 99 minutes. Green Lead for GUARD terminal

HV ON Indication Visual & Audible. Test Lead set 1 meter long with one end pointed tip &
another with 4mm shrouded banana.
Data Storage functions 1000 readings.
(For continuity range)
Data Recall function.

Auto discharge facility after every test

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - MIRT61 16

Features
Multi-featured single box design
Wide IR range up to 6GΩ, suitable for all LT applications
Selectable Voltage Facility 50, 100, 250, 500 & 1000V
Maximum test current of 1mA
Industrial Grade True RMS Multimeter functions
Voltage Measurement up to 1OOOV AC/DC
Dual Display LCD with Amber backlit
Auto Power Off Facility, Reading Hold / Lock, Min/Max,
FLT ( Filter )
Bluetooth enabled for Motware Mobile App

Mulitimete
r + IR Test
er
Connected to Cloud

MIRT-61
1KV Digital Multimeter Insulation Tester

CAT IV IP Applications
Ideal for Insulation Resistance Measurement during
1000V 54
maintenance for electrical equipments (Motors,

The Motwane's multipurpose tester model MIRT-61 is a versatile, Transformers, Machines, Switchgears etc.)
battery operated Digital Insulation Tester with true RMS industrial Electrical Wire/Cables for Distribution Networks
grade multimeter features, best suited for industrial preventive Control Panels
maintenance With test voltage range up to 1KV, highest insulation Electrical Contractors
Industrial, Commercial & Residential Installations
resistance range of 6GΩ and multi-featured function of RMS
Railways applications & Telecom applications
multimeter (i.e. AC/DC 1OOOV); makes it a superior offering for the
industry and service segments. It is designed predominantly for low
voltage insulation resistance testing in maintenance and services,
which involves the applications like Cables/Wires, Rotating Machines,
LT transformers, Switchgears and Industrial installations etc. It is
designed to suit the extreme environment conditions. Save your
operating cost and test more with this single box design rather than
buying two different products.

MIRT61 has Bluetooth connectivity module with Motware Mobile App


for remote access of testing data & storage in the cloud for further
analysis & record purpose.
Test & Measurement - MIRT61 17

Overload Protection
Technical Details MIRT61
Fuse protection for 'mA' Input Terminal
0.8A/250V fast blow type,
Ceramic fuse

Ω/ / / /Hz (%)/IRT 1000V DC / AC rms

General
Safety CE Certifications
Display 6000 counts, LCD with amber backlit
Directives for CE Certification: LVD: 2006/95/EC,
Polarity Automatic
EMC: 2004/104/EC.
Display Update Rate 3 Times per second nominal
Measurement Category: CAT IV (600V) Reinforced insulation.
DCV, ACV, Resistance, Capacitance, Relevant Standard (S): EN61010-1, EN61326-1
Ranges
Frequency, AC/DC Current, IRT
IP Rating (dust & water protection) : IP 54.

Dimensions 44mm(L) X 209mm(W) X 102mm(H)

Weight 620 gm. (with battery) approx. Accessories


Indications Low battery Indication “ ”below 6.5V approx. Standard

Auto Power Off After 10 mins Test lead set Red & Black one end with shrouded

Resistance Range banana 4 mm & another with crocodile clip : 1 Set

Range 600Ω- 60MΩ (0.1Ω to 10KΩ resolution ) Test lead Green, one end with shrouded banana 4 mm

Accuracy & another with crocodile clip : 1 No


+(1.2%+3) upto 600KΩ
Test lead set with one end pointed tip & another with
+(1.5%+5) from 600 KΩ to 6 MΩ
4mm shrouded banana: 1 Set
+(3%+5) from 6MΩ to 60MΩ
Batteries 1.5V AA Alkaline (IEC LR6) (Duracell Only): 6 Nos.
Capacitance Range
Instruction Manual: 1 No.
Range 6nF - 60mF ( 0.001nF to 10µF resolution )
Carrying Bag: 1 No.
Accuracy +(3%+10) upto 600mF
Calibration Certificate
+(5%+20) from 6mF - 60mF
Optional
Diode Test
Bluetooth option for Motware Mobile App.
Range 6V ( 1mV resolution )

Continuity Test Note : To learn more about the Motware Application, check Page 91

600.0Ω ( 0.10 resolution ) Meter Beeps


Range
at < 60Ω approx.

Frequency Range (Auto Ranging Only)


Range 60Hz - 60MHz

Resolution 0.01Hz

Accuracy ± (0.1%+3)
Overload Protection 1000V DC/AC rms

Duty Cycle Measurement

Range 0.1% - 99.9% ( with resolution 0.1% )

Accuracy +(0.5%+3 Digit)

Environmental
Operating Temperature 0°C to 50°C

Storage Temperature -20°C to 60°C

Relative Humidity 80% RH@ 5°C to 31°C , 50 % RH@ 31°C

to 40°C,Non-condensing
Test & Measurement - MIRT61 18

Technical Details MIRT61

DC and AC Voltage Measurement


DC Accuracy AC Accuracy
Range Max. Measur- Overload
No. Resolution Reading ement ± (reading ± (reading Protection
+ digit) + digit)

1050V
1 600mV 0.1mV 600.0mV DC +(0.9%+3) N/A DC/AC rms

2 6V 1mV 6.000V AC/DC +(0.9%+3) +(1%+5)

3 60V 10mV 60V AC/DC +(0.9%+3) +(1%+5)

4 600V 100mV 600V AC/DC +(0.9%+3) +(1%+5)

5 1000V 1V 1000V AC/DC +(0.9%+3) +(1.2%+8)

DC And AC Current Range


DC Accuracy AC Accuracy
Range Max. Overload
No. Resolution Reading ± (reading ± (reading Protection
+ digit) + digit)

0.8A/250V fast
1 600mA 0.1mA 600.0 mA +(1%+5) +(1.2%+5) blow type ceramic
fuse

Insulation Test
Output Range Resistance Accuracy
Resolution Test Current
Voltage (Auto Ranging only) +(% of rdg + Digits)

50 V 1 mA approx@
30 to 300 kΩ 1 kΩ +(3% + 5 counts)
+(10%+5) 50 kΩ
0.30 to 3.00 MΩ 0.01 MΩ
3.0 to 30.0 MΩ 0.1 MΩ
30 to 300 MΩ 1 MΩ
100 V 1 mA approx@
60 to 600 kΩ 1 kΩ +(3% + 5 counts)
+(10%+5) 100 kΩ
0.60 to 6.00 MΩ 0.01 MΩ
6.0 to 60.0 MΩ 0.1 MΩ
60 to 600 MΩ 1 MΩ
250 V 1 mA approx@
0.15MΩ to 1.50 MΩ 0.01 MΩ +(1.5% + 5 counts)
+(10%+5) 250 kΩ
1.5to 15.0 MΩ 0.1 MΩ
15 to 150 MΩ 1 MΩ
0.15 to 1.50 GΩ 0.01 GΩ
500 V 1 mA approx@
0.30MΩ to 3.00 MΩ 0.01 MΩ +(1.5% + 5 counts)
+(10%+5) 500 kΩ
3.0 to 30.0 MΩ 0.1 MΩ
30 to 300 MΩ 1 MΩ
0.30 to 3.00 GΩ 0.01 GΩ
1000 V 1 mA approx@
0.60MΩto 6.00 MΩ 0.01 MΩ +(10% + 3 counts)
+(10%+5) 1MΩ
6.0 to 60.0 MΩ 0.1 MΩ
60 to 600 MΩ 1 MΩ
0.60 to 6.00 GΩ 0.01GΩ
Test & Measurement - i-12 19

Features
Smart
Go-No-Go Test Facility.
Pre selectable Timer Facility.
Mains Eliminator.
Selectable Voltage Facility 50, 100, 250, 500 & 1000V.
Auto Ranging Measurement from 10KΩ to 2GΩ - wide range
Live Circuit Detection up to 600V AC/DC.
Low Resistance Measurement up to 100Ω with continuity testing.
Temporary Storage of 10 readings.
User Selectable Backlit to measurement in dark environment.
Low Battery Indication.
Auto Power Off Facility.
Blown Fuse Indication.
Safe
CE mark conforming to latest EN 61010-1:2010.
EN 61326-1:2005, CAT IV 600V, IP54 protection.
Overload protection 1200V for all ranges.
Guard Terminal to minimize surface leakage.

Strong
i-12 Robust and Rugged Polycarbonate casing.
1KV Battery Operated Digital Insulation Resistance

CAT III CAT IV IP Applications


1000V 600V 54
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
The Motwane's Digital Insulation Tester model i-12 is a compact, light- resistance quality of an electrical system degrades with
weight, hand held, battery and mains operated (with the help of time, environment condition i.e. temperature, humidity,
mains eliminator) best suited for industrial use. i-12 is a 1kV insulation moisture and dust particles. The instrument is designed for
tester with maximum range of 2GΩ for Insulation Resistance routine and diagnostic testing like IR of high voltage electric
Measurement and is designed predominantly for low voltage apparatuses and useful to the following segments:
insulation resistance testing in maintenance and services, which
involves the applications like Cables, Rotating Machines, LT Electrical Equipment
Transformers, Switchgears and Industrial installations. It has (Motors, Transformers, Machines, etc.)
selectable test voltages of 50V, 100V, 250V, 500V and 1000V. The Industrial, Commercial & Residential Installations.
insulation tester is provided with additional low resistance Cables for Distribution or Communication Networks.
measurement and AC/DC voltage measurements to. It is designed to House Hold Appliances
suit the extreme environment conditions (Washing Machines, Mixer, Toaster, etc.)
Control Panels.
Railway and Metal Industry Applications.
Metal Industry Applications
Test & Measurement - i-12 20

Power
Technical Details i-12
Battery : 6 X 1.5V cells IEC LR6 Alkaline

(Nickel Cadmium rechargeable cells may also used)

(Battery symbol appears on the LCD screen, battery replacement

is necessary.)

General Mains Eliminator

Input : 230VAC, 50/60Hz


Display 1/
3 digit LCD with backlit
2

Output : 12 VDC, 1000mA


Analog Display Logarithmic Scale

Display 7 segment digits

Enclosure Material Polycarbonate Safety


CE Mark
Dimensions 102 mm(W) x 209 mm(H) x 44mm(D)
Directives for CE : LVD:2006/95/EC.,
Net Weight (Instrument) Approx. 60g (With battery excluding accessories)
EMC : 2004/104/EC
Gross Weight (with Accessories) Approx. 1 Kg. Measurement Category : CAT III 1000V/CAT IV 600V Reinforced

Environmental Insulation

0 0 Relevant Standard Specifications : EN61010-1:2010,


Nominal Temp. Range 0 C to 35 C
EN61326-1:2005
Operating Temp. -200C to 400C (Full Range)
IP Rating (Dust & Water Protection) : IP 54
200C to 600C (Up to 100M Ω ) Type tested as per : IS 10656

Storage Temp. 0
-25 C to 65 C 0

Relative Humidity 90% RH at 400C max


Accessories
Technical
Standard
Measurement Accuracy Overload
Range Resolution
Function ± (% reading+dgt) Protection Set of test leads of 1m length with crocodile clips
Instruction Manual
Insulation 0.01 MΩ to 0.99 MΩ 10 KΩ (0.01 MΩ ) ± (3% ± 2) 1200 V rms
Resistance (10 sec) Warranty Card
>1.0 M Ωto 99.9 M Ω 100 KΩ (0.1 M Ω ) ± (5% ± 2)
MΩ *1 Batteries 6 X 1.5V AA, Alkaline (IEC LR6)
(50V,100V) >100 MΩ to 999 MΩ 1MΩ ±(10%± 5) Fuse (800mA/600V)
0.01 MΩ to 9.99 MΩ 10 K Ω(0.01 M Ω ) ± (5% ± 2)
Insulation Optional
Resistance >10 M Ω to 99.9 MΩ 100 K Ω (0.01 MΩ ) ± (5% ± 2)
MΩ /G Ω*1
Mains eliminator (12 VDC, 1000mA output)
(250V,500 >100 MΩ to 999 MΩ 1 MΩ ±(10%± 5) Test lead set
V,1000V)
1G Ω to 2G Ω 10M Ω ±(10%± 5)

0 - 9.99 Ω 0.01Ω at 100 mA ± (3% ± 2)


Low Ohms
( Ω ) *2
>10 Ω to 99.9 Ω 0.1Ω at 10 mA ± (5% ± 2)

Continuity Test
0 - 9.99 Ω 0.01 Ω ± (3% ± 2)
Current 100mA

25V - 450V 1V ± (2% ± 2)


V AC/DC
450V - 600V 1V ± 3%

*1 For Insulation resistance range,

Terminal voltage on Open Circuit (DC) : - 0% to + 30% of rated voltage

Short Circuit current : < 2 mA

*2 For low Ohms/Continuity Ranges

*Open Circuit Voltage : 5V + 2V d.c.

*Lead Resistance compensation : 0 - 9.99Ω

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM-25A 21

Features
Test Current : 25A, 10A, 5A, 1A, 100mA & 10mA
Resolution of 0.1μΩ with + 0.1% Accuracy
3 independent channels for resistance measuring
Auto Range Facility
Heat Run Test Facility
60V High Open Circuit Voltage for stable readings
Demagnetization Facility
OLTC Dynamic Resistance Test with Graph: Time vs Current
Inbuilt Thermal Printer & Memory
Bluetooth enabled for Motware Mobile App
Temperature Measurement & Correction
Emergency Stop Switch

Connected to Cloud

XWRM-25A
Winding Resistance Meter

CAT III IP Applications


600V 54 Winding Resistance Test is an essential test which enables to
identify shorted turns, loose connections, or deteriorating
XWRM-25A transformer is a Winding Resistance Meter designed for contacts in tap changers and measurements on all tap
accurate & fast measurement of highly inductive loads such as changer positions in transformer (if present) and compared
Transformers, Reactors, Generator & HT Motors etc. The selectable to previous or factory test values for evaluating the
smooth DC test current is useful to test transformer with different condition of the transformer windings and leads. The
power ratings. Higher Open Circuit voltage saturate the core in acceptance criteria for the field-measured values should be
quickly in order to get stable readings. The three resistance within 3% of the factory values. A change greater than the
measurement channels for simultaneous measurement of three acceptance criteria is indicative of short-circuited turns,
windings help to reduce testing time. The heat run test feature is poor joints, or bad tap changer contacts. This test should be
available with graphical representation through software and also has performed during acceptance testing and when other
demagnetization facility, which eliminates the magnetic remanence maintenance electrical tests are conducted.
effects. XWRM-25A has facility to test make-before-break operation
of on-load tap-changers which helps in the analysis of OLTC switch Power Transformer
contacts. The Back EMF feature protects XWRM-25A from high Motor and Generator
inductive kickbacks. The large LCD display with keypad provides easy Reactor
operation. It also has the Software for remote operation and detail Heat Run Test
report generation. Also have an internal memory to store 2000 test OLTC Dynamic Test
results and inbuilt thermal printer provided for onsite report.

XWRM-25A has Bluetooth connectivity module with Motware mobile


app for remote access of testing data & storage in the cloud for
further analysis & record purpose.
Transformer Testing Instruments - XWRM-25A 22

Display LCD

Indication LED & Beep during test ON, & discharge.


Technical Details XWRM-25A
PC Interface USB

Internal Memory 2000 test readings

Printer Inbuilt thermal printer

Technical Specifications Safety & Standards


Safety & Standards : IP54
Power Supply 115/230VAC, 50/60 Hz CAT III - 600 V
CE Certification
Safety : Meets requirement of IEC 61010-1
Test Current 25A, 10A, 5A, 1A, 100mA & 10mA
EMC : Meets requirement of IEC 61326-1
Open-Circuit Test Voltage 60 VDC
Environmental
Burden 1500 W
Operating Temperature 0°C to 55°C
Resistance Measurement Range
Accuracy +(0.1% of rdg. + 5 counts) Storage Temperature -10°C to 60°C

Humidity 95% RH, Non condensing

Range Resolution Maximum Physical Specifications


Test Current Display
(Ω) (Ω)
(Ω)
Physical Specifications 525mm(L) x 437mm(W) x 213mm(H)
25A 10A 5A 1A 100mA 10mA 15 Kg (Approx)
Weight
P 200 μΩ 0.01 μΩ 199.99 μΩ
Software Details
P P 2 mΩ 0.1 μΩ 1.9999 mΩ
Type Windows based analytical software
P P P 20 mΩ 1 μΩ 19.999 mΩ Real time data transfer
Data Transfer
P P P P 200 mΩ 10 μΩ 199.99 mΩ Features Online Data Acquisition
Graph Plotting for Heat Run Test
P P P P 2Ω 0.1mΩ 1.9999 Ω
& OLTC Dynamic Test
P P P 20 Ω 1 mΩ 19.999 Ω Remote Operation
Test Report Generation
P P 200 Ω 10 mΩ 199.99 Ω

P 2000 Ω 0.1 Ω 1999.9 Ω Accessories


P 4 mΩ 0.1 μΩ 4.0000 mΩ Standard

P 40 mΩ 1 μΩ 40.000 mΩ 15 meter measuring test lead set


Mains cord
P 400 mΩ 10 μΩ 400.00 mΩ
Short links - 2Nos.
P 4Ω 0.1mΩ 4.0000 Ω
Earthing lead
User Manual
Calibration Certificate
Carry Case for Test leads
General
Optional
Principle 4 wire measurement
OLTC Probe
Measurement Channel 3 Resistance & 1 Current channels PC Software
Temperature Channel 2 Channel USB Cord

Temperature Range 0 - 100°C


Temperature Sensor
20 Mtr. Test Leads with alligator clamp
Test Leads with C clamp
Bluetooth application via cloud based Motware
application

Note : To learn more about the Motware Application, check Page 91

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM - 10A 23

Features
Test Current : 10A, 5A, 1A, 100mA & 10mA
Resolution of 0.1μΩ with +0.1% Accuracy
3 independent resistance measuring channels
Auto Range Facility
Heat Run Test Facility
48V Open Circuit Voltage for stable readings
Demagnetization Test Facility
OLTC dynamic test with Graph : Time vs Current
In-built Thermal Printer & Memory
Bluetooth enabled for Motware Mobile App
Temperature Measurement & Correction
Emergency Stop Switch

Connected to Cloud

XWRM-10A
Transformer Winding Resistance Meter

CAT III IP Applications


Winding Resistance Test is an essential test which enables to
600V 54
identify shorted turns, loose connections, or deteriorating
contacts in tap changers and measurements on all tap
XWRM-10A transformer winding resistance meter designed for
changer positions in transformer (if present) and compared
accurate & fast measurement of highly inductive loads such as
to previous or factory test values for evaluating the
Transformers, Reactors & HT Motors etc. The selectable smooth DC
condition of the transformer windings and leads. The
test current is useful to test windings with different ratings. 48V open
acceptance criteria for the field-measured values should be
circuit voltage saturates the core in quick time in order to get stable
within 3% of the factory values. A change greater than the
readings. The three resistance measurement channels for
acceptance criteria is indicative of short-circuited turns,
simultaneous measurement of three windings reduces testing time.
poor joints, or bad tap changer contacts. This test should be
The heat run test feature is available with graphical representation
performed during acceptance testing and when other
through software and also has a demagnetization facility, which
maintenance electrical tests are conducted.
eliminates the magnetic remanence effects. XWRM-10A has a facility
to test the make-before-break operation of on-load tap-changers Power Distribution Transformer
which helps in the analysis of OLTC switch contacts. The Back EMF Motor and Generator
feature protects XWRM-10A from high inductive kickbacks. The large Reactor
LCD display with keypad provides easy operation. Also have an
Heat Run Test
internal memory to store 2000 test results and inbuilt thermal printer
provided for onsite report.

XWRM10A has Bluetooth connectivity module with Motware mobile


app for remote access of testing data & storage in the cloud for
further analysis & record purpose
Transformer Testing Instruments - XWRM - 10A 24

Safety & Standards


Ingress Protection : IP54
Technical Details XWRM-10A
CAT III 600V
CE Certification
Safety : Meets requirement of IEC 61010-1
EMC : Meets requirement of IEC 61326-1

Technical Specifications
Power Supply 115/230VAC,50/60 Hz Environmental

10A, 5A, 1A, 100mA & 10mA Operating Temperature 0°C to 55°C
Test Current
Open Circuit Test Voltage 48 VDC Storage Temperature -10°C to 60°C

Humidity 95% RH, Non condensing


Burden 500 VA

Physical Specifications
Resistance Measurement Range
Physical Specifications 485mm x 392mm x 192mm
Accuracy +(0.1% of rdg. + 5 counts)
10 Kg (Approx)
Weight

Range Maximum
Resolution Analytic Software
Test Current Display
(Ω) (Ω)
(Ω) Type Windows based analytical software

10A 5A 1A 100mA 10mA Data Transfer Real time data transfer

Features Online data acquisition


P 2m Ω 0.1uΩ 1.9999mΩ
Graph plotting for heat run test
P P 20m Ω 1uΩ 19.999mΩ & OLTC dynamic test
Remote operation
P P P 200mΩ 10u Ω 199.99mΩ Test report generation

P P P P 2Ω 0.1mΩ 1.9999 Ω

P P P 20 Ω 1m Ω 19.999 Ω Accessories
P P 200Ω 10mΩ 199.99 Ω
Standard
P 2000Ω 0.1 Ω 1999.9 Ω
15 meter measuring test lead set with alligator clamp
P 4m Ω 4µΩ 4.0000m Ω Mains Power cord

40mΩ 1µ Ω 40.000m Ω Short links - 2Nos.


P
Earthing lead
P 400m Ω 10µΩ 400.00m Ω
User Manual
P 4Ω 0.1mΩ 4.0000m Ω Calibration Certificate
Carry Case for Test leads

Optional
General
OLTC Probe
Principle 4 wire measurement
PC Software
Measurement Channel 3 Resistance & 1 Current channels
USB Cord
Temperature Channel 2 Channel Temperature Sensor

Temperature Range 0 - 100°C 20 Mtr. Test Leads with alligator clamp


Test Leads with C clamp
Display LCD
Bluetooth application via cloud based
Indication LED & Beep during test ON, & discharge.
Motware application
PC Interface USB
Note : To learn more about the Motware Application, check Page 91
Internal Memory 2000 test readings

Printer Inbuilt thermal printer

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XTRM-3 25

Features
Test Voltage : 10V, 40V, 100V
Measure Turns Ratio, Voltage Ratio & Ratio Error
Measure Phase Deviation & Excitation Current
Auto Detection of Transformer Vector Group
Quick set up with intuitive guide
Inbuilt Printer with Memory for 500 test results
Bluetooth enabled for Motware Mobile App

Connected to Cloud

XTRM-3
Transformer Turns Ratio Meter

CAT III IP Applications


600V 54 Transformer Turn Ratio Meter determines the turns ratio and
polarity of single and three-phase transformers and also
confirm nameplate ratio, polarity, and vectors and useful in
Motwane's Transformer Turns ratio Meter XTRM-3 is a new generation
identifying trouble in the in transformer windings, such as
fully automated kit to measure Turns Ratio, Voltage Ratio, Ratio Error,
open circuit and short circuit of turn-to-turn sensitivity.
Phase Displacement and Excitation Current in Transformer. It also
automatically detects transformer vector group. User selectable test Turn Ratio testing of Single phase/ Three phase
voltage provided to test various ratings of power transformers. Auto Transformers, Power Transformers and
XTRM-3 controls from remote position using TAP changer option
Distribution Transformers
which allows operator to perform measurement at various Tap
Turn Ratio testing of Instument Transformers
position and has quick setup templates which automatically
calculates nameplate voltage ratios of transformer to avoid time
consuming process by adding details of each TAP ratio. Internal
memory for 500 test results provided to save results during testing on
site. Emergency safety switch is provided for operator's safety during
undesired condition.

XTRM-3 has Bluetooth connectivity module with Motware mobile


app for remote access of testing data & storage in the cloud for
further analysis & record purpose.
Transformer Testing Instruments - XTRM-3 26

Safety Features
Technical Details XTRM-3
Safety / EMC in accordance with EN 61010-1, EN 61326-1
CE Certified
Ingress Protection IP54 / CAT IV 600V
Emergency Stop
Technical Specifications
Power Supply 115V/230V AC, 50/60 Hz Full Windows Compatible Software
Measurement ratio 0.8 : 10000 Software is fully compatible with Microsoft

Type Window based Software

Ratio Accuracy Interface USB communication port

10V +0.15% (0.8 - 999) Features Remote Operation

Data Downloading

40V +0.1% (0.8 - 999) Analysis and Report Generation

+0.15% (1000 - 1999)

+0.20% (2000 - 3999)


Accessories
+0.25% (4000 - 10000)
Standard

+0.1% (0.8 - 999) Mains Power Cord


100V
Main Protected Fuse
+0.15% (1000 - 1999)
Extension Cable
+0.20% (2000 - 3999) 15m Measuring Test Lead Set with alligator clips

+0.25% (4000 - 10000) Thermal Paper roll


Instruction Manual
Calibration Certificate
Test Voltage 10V AC, 40V AC, 100V AC

Excitation Current Upto 2A Optional

Software 1 No
Resolution 0.1mA
USB Cable 1 No
Phase Angle +1800
Remote tap changer switch 1 No
Phase Angle Resolution 0.01 20 Mtr. Test Leads with alligator clamp
Accuracy 0
+0.50 + 1digit Bluetooth application via cloud based
Motware application
Display LCD

Printer Built in Thermal Printer

PC interface USB Note : To learn more about the Motware Application, check Page 91

Report Storage 500 reports

Environmental Specifications
Operating Temperature 00C to 400C

Storage Temperature -100C to 600C

Relative Humidity <95%RH at 400C max (non condensing)

Physical Specifications
Dimensions 188 mm(L) x 401mm(W) x 502mm(H)

Weigh 15 kg (Approx)
Test & Measurement - MOTR 27

Features
Dissipation Factor , Volume Resistivity, Dielectric Constant
(Permittivity), Watt Loss
Inbuilt Oil Heating Chamber with precise temperature control
Test Cell according to IEC 60247
Preprogrammed & Customized Test Sequences
Inbuilt Thermal Printer
Internal Memory for 250 Test
USB Interface
Portable Calibrator
Oil Auto Drain Facility
Auto Sequence Test
Bluetooth enabled for Motware Mobile App

MOTR Connected to Cloud

Oil Tan Delta & Resistivity Tester

CAT III IP
Applications
600V 54 Ÿ The
The dissipation
dissipation
factor
factor
indicates
indicates
the
thedielectric
dielectricloss
lossof
of the
liquid andand
liquid thusthus
it's dielectric heating.
it's dielectric The dissipation
heating. factor
The dissipation
testfactor
is widely
test used as anused
is widely acceptance and preventive
as an acceptance and
Motwane's MOTR is a microprocessor-based compact designed for
maintenance
preventivetest for insulatingtest
maintenance oil. The
for dissipation
insulating factor of
oil. The
precise measurement of the dissipation factor and volume resistivity
newdissipation
oil should not exceed
factor 0.05
of new oil%should
and the dissipation
not factor
exceed 0.05 %
of insulating oils. MOTR is built in a single unit and on boarded with
canand
gradually increase in factor
the dissipation servicecan
to a gradually
value as high as 0.5%,
increase in
international test standards for automatic measurement of all
i n service
m o st cto
ase
a s value
, i n d ias
c a thigh
i n g as
d e te r i o ra
0.5%, int i most
o n a ncases,
d /o r
parameters and also available with customized test sequences to
contamination with moisture,
indicating deterioration carbon,
and/or varnish, glyptal,
contamination with
conduct tests as per the user's requirement. The test cell is designed
sodium soaps,carbon,
moisture, or deterioration
varnish, products.
glyptal, sodium soaps, or
as per IEC 60247 with precise control for measuring dissipation factor
deterioration products.
and resistivity at 27°C & 90°C. MOTR also has an auto drain facility. It is ŸUsed Oil having a dissipation factor of less than 0.5% is
provided with internal memory & printer for on-field reports and also Used considered
Ÿusually Oil having a dissipation
satisfactoryfactor
for of less than
service and0.5% is
with
has a USB interface available for data transfer. The calibrator with usually considered
dissipation satisfactory
factor between 0.5% for
andservice and with
2% should be
standard dissipation factor & resistivity ranges are available for dissipation
considered factorinbetween
as being doubtful 0.5% and 2%
and further should be
investigation
validating the performance of MOTR. considered and
recommended as being in doubtful
in excess of 2.0 % andmayfurther
be an
investigation
operational recommended
hazard. and in excess of
It should be reconditioned or2.0 % may
replaced.
MOTR has a Bluetooth connectivity module with Motware mobile app
for remote access of testing data & storage in the cloud for further Useful for measuring the quality of insulating oil, used in
analysis & record purposes. electrical apparatuses like:

Power & Distribution Transformers


OLTC
HV Cables
Switchgear
Capacitor
Bushing
Instrument Transformer
Test & Measurement - MOTR 28

Heater
Technical Details MOTR
Temperature Range 20°C - 150°C

Accuracy +0.5°C

Resolution 0.1°C

Technical Specification Temperature Control One set point (max110°C)

AC Voltage 400-2400 V Heating Element Induction Type

Resolution 1V Sensor Solid state (PT100)

Accuracy +1%

Test Standards IEC 60247, VDE 0380, BS 5737,


ASTM D924, ASTM D1169, JISC2101:2010
DC Voltage 100 – 1000V
Display Alphanumeric LCD Display
Resolution 1V
Printer Inbuilt Thermal Printer
Accuracy +1%
Memory 250 Test

Power Supply 110V / 230V, 50/60Hz +15%


Dissipation Factor 10e-5 – 4.0

Resolution 1 X 10-5
Operating Temperature -100C to 500C, 90% non condensing
Accuracy +1% of rdg + 0.0001 (1 X 10-4)
Safety Standards IEC61010-1, IEC61326-1

Dimension 510mm(L) X 320mm(W) X 380mm(H)


Capacitance 0 -1600 pF
Weight 24 Kg (Approx)
Resolution 0.01 pF

Accuracy +0.1% +1pF

Accessories
Standard
Dielectric Loss 0 -10.0 watts
Test Lead sets
Resolution 0.001 mili Watts
Oil Test Cell with 3 Terminals
Accuracy +1% of Reading + 10-5 Watts
Standard Calibrator
Pen drive loaded with MOTR software
software
Dielectric Constant 1-30
USB Cord
Resolution 0.001
Calibration Certificate
Transportation case

Resistivity 106 to 1015 Ω


Optional
Accuracy +2% at 109- 1013 cm Motware Mobile App
13 14
+5% at 10 - 10 cm Oil Auto Drain Facility

+10 % above 1014cm Note : To learn more about the Motware Application, check Page 91

Resolution 0.001

Test Cell
Cell Constant 620 Nominal

Capacitance 55.5pF + 1pF

Insulation Teflon (PTFE)

Electrode Spacing 2mm

Volume of Oil 60ml

Calibrator Test Cell


Transformer Testing Instruments - OTS 29

Features
Fully Automatic Microprocessor based
Pre-programmed International Test Standards
Customized Test Sequences
Voltage Slew Monitoring: Real Breakdown Monitoring (RBM)
Upgraded Sequence as per IEC60156-2018
Suitable to test Mineral, Ester & Synthetic Oil
Internal Memory up to 100 Test
USB Interface
Inbuilt Thermal Printer
Voltage Checker for onsite Calibration (Optional Accessories)
Bluetooth enabled for Motware Mobile App

Connected to Cloud

OTS-60A/80A/100A
Automatic Oil Insulating Test Set

Applications
Transformer oil is used as insulating medium in transformer,
switchgear and other electrical apparatuses and it also acts
as a coolant which dissipates (or to dissipate) heat of the
OTS-A series is a fully automatic microprocessor-based Oil BDV
transformer. In addition to these, insulating oil serves other
Tester designed with advanced technologies to measure the
purposes like, it helps to preserve the core and winding as
electrical breakdown strength of insulating oil. OTS-A has a quick
these are fully immersed inside oil and another important
sensing ability to measure accurate breakdown voltage. OTS-A series
purpose of Insulating oil is, it prevents direct contact of
is equipped with national & international standards for test sequences
atmospheric oxygen with cellulose made of paper insulation
and it also has has user-friendly customized test sequences. The large
used in windings, which is susceptible to oxidation. When
LCD display with keypad provides easy operation. It is provided with
insulating oil deteriorates due to aging / contamination
internal memory for 100 data storage & inbuilt thermal printer for the
which leads to catastrophic event due to flashover in
onsite report. As for safety, the OTS-A series has open ground
insulation. The voltage withstands capability of oil which
detection feature to avoid damage. The molded oil test vessel is
often is reduced ( which often reduces) due to
suitable to test Mineral, Easter & Synthetic Oil and it is provided with
contamination like dirt, water ingress and foreign particles.
an adjustable electrode gap setting to conduct the test as per
standards. The portable voltage checker is useful for onsite
The Motwane's OTS-A series useful for Oil Testing
calibration verification.
in the following equipments:
OTS-A series has a Bluetooth connectivity module with Motware
mobile app for remote access of testing data & storage in the cloud Power and Distribution Transformer
for further analysis & record purposes. Bushing
Instrument Transformer
Switchgear
Capacitors
Transformer Testing Instruments - OTS 30

Technical Details OTS-60A/80A/100A Accessories


Standard

Oil test vessel with Mushroom Electrode Assembly


Magnetic Oil Stirrer
Technical Specification Retriever for magnetic stirrer
Electrode gauge set - 1.0mm / 2.0mm / 2.5mm /
Mains Supply 110V/230V, +10%, 50/60Hz
2.54 mm / 4.0mm
Output Voltage 0 - 100kV (OTS - 100A)
Pendrive loaded with OTS software
0 - 80kV (OTS - 80A) USB Cord
Mains Power Cord
0 - 60kV (OTS - 60A)
User Manual
Voltage Accuracy +0.1% +1kV
Calibration Certificate
Voltage Resolution 0.1kV Spherical Electrodes Set
Flat Electrodes Set
Rate of Rise 0.5kV to 9.9kV/sec & custom selected
Optional
Tripping Current <10μ Sec
Voltage Checker (100kV)
Pre-Programmed Standards
Motware Mobile App
IEC 60156-2018, IEC 60156-1995, 5 min. Test, IS6792, ASTM D877, ASTM D1816,

UNE 21, BS5730A, BS 148, BS5874, VDE 0370, NFC 27, CE1344, BS5730, OCT 6581, Note : ** Applicable for OTS 100A upto 9.9 kV /sec.

SABS 555, AS1767, STA 8286, STAS 286, IP 295, Withstand A, Withstand B Maximum custom selected and for OTS 80A & OTS 60A
upto 5 kV /sec max.
Manaual Test,

Customized Test Standards 10 Note : To learn more about the Motware Application, check Page 91

Programmable Parameters Stand time – 0 to 999 secs

Stirring Time – 0 to 999 secs

Intermediate Stand time – 0 to 999 secs

Voltage Ramp-up– 0.5kV/sec to 5kV/sec

Iterations - 24

Temperature Measurement 0 – 99.9°C

Temperature Resolution 0.1°C

PC Interface USB

Printer Inbuilt Thermal Printer

Internal Memory 100 Rest Results

Display Large LCD Colour Display

Protection
Zero Start and HT Cover Open Interlock

Auto Trip and Reset

Open Ground Protection

Overload Protection

Environmental Condition 0°C to +55°C, <90% RH, Non Condensing

Safety Standards IEC 61010-1 : 2010 AMD : 2016

EMC Standards IEC61326

Dimension 655 mm(L) x 327 mm(W) X 385 mm(H)

Weight <40 Kg (Approx)


Transformer Testing Instruments - OTS 31

Features
Motorized Operation with 2kV/s ramp rate
Safety Door & Zero Start Interlock
Digital Display with optional Hold Facility till Variac
goes zero position
Voltage Checker for onsite checking (optional)
Earth Open Interlock
Bluetooth enabled for Motware Mobile App

Connected to Cloud

OTS-60DS/80DS/100DS
Digital Oil Insulation Test Set

Applications
Transformer oil is used as insulating medium in transformer,
switchgear and other electrical apparatuses and it also acts
Motwane offers a wide range of Oil Breakdown Voltage test kits to as coolant to dissipate heat of the transformer. In addition to
check dielectric strength of insulating oil used in Transformers, these, Insulating Oil serves other purposes like it helps to
Capacitors, Switchgears and Instrument Transformer for safe preserve the core and winding as these are fully immersed
operation and maintenance. OTS-DS series Series is meeting to inside oil and another important purpose of insulating oil is,
national & international standards for conducting BDV Test. It is also it prevents direct contact of atmospheric oxygen with
facilitated with Zero Start Interlock and Earth Open Interlock for cellulose made of paper insulation used in windings, which is
safety and avoid hazards. Also equipped with LED (Digital Display) susceptible to oxidation. When insulating oil deteriorates
along with Hold Facility. Designed with unmatched quality and due to aging / contamination which leads to catastrophic
improved reliability and safety having earth & zero start, safety door event due to flash over in insulation. The voltage withstands
interlock ensuring high degree of protection. OTS comes with two capability of oil which often is reduced (which often
variants models- OTS-A series - a pre-programmed fully Automatic reduces) to contamination like dirt, water ingress and
Oil BDV kit and OTS-DS Series - Motorized with Digital Display. foreign particles.

OTS-DS series useful for Oil Testing in following


equipment's

Power and Distribution Transformer


Bushing
Instrument Transformer
Switchgear
Capacitors
Transformer Testing Instruments - OTS 32

Accessories
Technical Details OTS-60DS/80DS/100DS
Standard

Oil test vessel with Mushroom Electrode Assembly


Magnetic Oil Stirrer
Lifting stick for Magnetic Stirrer
Technical Specification
Go - No - Go Gauge
Mains Supply 110V/230VAC +10% 50/60Hz Single Phase
Mains Power Cord
Output Voltage 0 - 100kV (OTS - 100DS) User Manual
Calibration Certificate
0 - 80kV (OTS - 80DS)
Earth Lead
0 - 60kV (OTS - 60DS)
Spanner
Voltage Accuracy + 1% + 1kV Spare Fuses

Voltage Resolution 0.1kV


Optional
Voltage Rise Rate 2kV/sec
Voltage Checker
Bluetooth enabled & Motware Mobile App

Standards complying IEC 60156, IS6792


Note : To learn more about the Motware Application, check Page 91
Display 3 ½ digit LED digital

Earth Open Interlocking

Protection Zero Start Interlock

Safety Door Interlock

Earth Open Interlock

Overload Protection

Operating Temperature 0°C to 55°C, <90% RH, Non condensing

Storage Temperature -10°C to 55°C

Dimension 655mm(L) X 327mm(W) X 385mm(H)

Weight < 40kg


Contact Resistance/Low Resistance Meter - PCRM-200S 33

Features
100A & 200A Pulsating DC selectable Test Current
Resistance Range : 0.1μΩ to 20mΩ, Autoranging
Direct mV Drop Reading
Built in Thermal Printer
Internal Memory of 500 test results
Mains and Battery Operated
USB Interface for Data Transfer
LED Indication for Mains/Battery/LOBAT
Calibration Due Indicator
Dual Grounding Facility
Conformity IP54, CE
Bluetooth enabled for Motware Mobile App

Connected to Cloud

PCRM200S
Contact Resistance Meter

CAT II IP Applications
300 54 Stationary and moving contacts are built from alloys that are
formulated to endure the stresses of electrical arcing.
The Motwane's Digital Contact Resistance Meter, Model However, if contacts are not maintained on a regular basis,
PCRM-200S is specially designed to measure extremely low their electrical resistance due to repeated arcing builds up,
resistances in micro ohm. The Instrument is based on Kelvin 4- wire resulting in a significant decrease in the contact's ability to
connection method for measurement of low resistance. User carry current and increase in resistance. Excessive corrosion
selectable current injection is 100A/200A. PCRM 200S has large LCD of contacts is detrimental to the breaker performance.
with backlight and display real time test information like injected Hence to check contacts is to apply DC and measure the
current with measured resistance value & voltage drop. User friendly contact resistance or voltage drop across the closed
instrument and it comes with heavy duty cable with clamps for contacts. The use of a higher current value gives more
accurate measurement and accessories are housed in easy reliable results than using lower current values. The
transportation case. Advance Windows based software is provided resistance value is usually measured in micro ohms (μΩ).
for data downloading, analysis and report generation. Internal
PCRM-200S is specially used to measure static contact
memory of 499 records is provided for onsite data storage and inbuilt
resistance of LV, HV, EHV circuit breaker contacts installed in
thermal printer to print the test results at the field.
energised switchyards. High accuracy and repeatability
PCRM 200S has dual ground technique to test circuit breaker with makes it a reliable tool for Quality Assurance and easy
both side grounded, which is safer to conduct test in substation. operation makes it a very handy tool for quick maintenance
checks in various industries
PCRM 200S has Bluetooth connectivity module with Motware mobile
app for remote access of testing data & storage in the cloud for Typical resistance measurement applications are
further analysis & record purpose. Circuit Breaker contact resistance
Bus bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-200S 34

Software Details
Technical Details PCRM 200S
Type Windows based software

Interface USB

Data Transfer Real Time Data

Internal Data Storage 500 Test results


Technical Specification
Features Remote Operation
Test Current Injection 100A & 200A Pulsating DC selectable
Data down loading
Test ON Alert BEEP
Analysis and report generation
Range & Resolution 20µΩ with 0.1µΩ

200µΩ with 0.1 µΩ


Accessories
2000µΩ with 1µΩ
Standard
20mΩ with 0.01mΩ
15 meter lead set with C Clamp 75mm opening
Master Earthing Cable (5 meter)
Measurement Principle Four wire measurement Mains power cord

Basic Accuracy + 1% of reading, + 5 digits User Manual


Calibration Certificate
Memory Storage 500 reading storage facility
Thermal Paper Role
Computer Interface USB Spare Fuse (3A/250V slow blow)

Thermal Printer For printing the test results.


Optional
Display Custom Built 3 ½ digit LCD Display with Backlit
22 meter lead set with C Clamp 150mm jaw size
Physical Specifications 15 meter heavy duty lead set with alligator clip

Enclosure Material Industrial grade Polypropylene Software and USB Cord


Bluetooth application via cloud based
Dimensions 188mm(L) x 395mm(W) x 502mm(H)
Motware application
Weight 25 Kg (Approx)

Power Supply
Note : To learn more about the Motware Application, check Page 91
Mains 115V-230V, 50Hz / 60Hz Single phase AC supply

Battery Rechargeable Li-ion, 14.8 v 5.6 A

Power Consumption 35VA, 6.0 Watt on battery

Environmental
Operating Temperature 0°C to 55°C.

Storage Temperature 0°C to 50°C.

Humidity less than 95% RH, Non condensing.

Safety Standards
Safety According to EN 61010 - 1

EMC According to EN 61326 - 1

IP Rating IP 54

Measurement Category CAT II

CE Certification LVD: 2006/95/EC

EMC Certification 2004/104/EC

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - PCRM-100S 35

Features
100A Pulsating DC Test Current
Resistance Range : 0.1μΩ to 2mΩ Autoranging
Direct mV Drop Reading
Built in Thermal Printer
Internal Memory of 500 test results
Mains and Battery Operated
USB Interface for Data Transfer
LED Indication for Mains/Battery/LOBAT
Calibration Due Indicator
Dual Grounding Facility
Conformity IP54, CE
Bluetooth enabled for Motware Mobile App

Connected to Cloud

PCRM 100S
Contact Resistance Meter

CAT II IP Applications
300 54 Stationary and moving contacts are built from alloys that are
formulated to endure the stresses of electrical arcing.
The Motwane's Digital Contact Resistance Meter, model However, if contacts are not maintained on a regular basis,
PCRM-100S is specially designed to measure extremely low their electrical resistance due to repeated arcing builds up,
resistances in micro ohm. The instrument is based on Kelvin 4- wire resulting in a significant decrease in the contact's ability to
connection method for measurement of low resistance. Selectable carry current and increase in resistance. Excessive corrosion
current injection is 100A. PCRM 100S has a large LCD with backlight of contacts is detrimental to the breaker performance.
and display real time test information like injected current with Hence to check contacts, apply DC and measure the contact
measured resistance value & voltage drop. It is a user-friendly resistance or voltage drop across the closed contacts. The
instrument and it's comes with heavy duty cable with clamps for use of a higher current value gives more reliable results than
accurate measurement and accessories are housed in easy using lower current values. The resistance value is usually
transportation case. Advance Windows based software is provided measured in micro ohms (μΩ).
for data downloading, analysis and report generation. Internal
PCRM-100S is specially used to measure static contact
memory of 499 records is provided for onsite data storage and inbuilt
resistance of LV, HV, EHV circuit breaker contacts installed in
thermal printer to print the test results at the field.
energised switchyards. High accuracy and repeatability
PCRM 100S has dual ground technique to test circuit breaker with makes it a reliable tool for Quality Assurance and easy
both side grounded, which is safer to conduct test in substation. operation makes it a very handy tool for quick maintenance
checks in various industries.
PCRM 100S has Bluetooth connectivity module with Motware mobile
app for remote access of testing data & storage in the cloud for Typical resistance measurement applications are
further analysis & record purpose. Circuit Breaker contact resistance
Bus Bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-100S 36

Software Details
Technical Details PCRM 100S
Type Windows based software

Interface USB

Data Transfer Real Time Data

Internal Data Storage 500 Test results


Technical Specification
Features Remote Operation
Test Current Injection 100 A Pulsating DC
Data down loading
Test ON Alert BEEP
Analysis and report generation
Range & Resolution 200µΩ with 0.1 µΩ

2000 µΩ with 1 µΩ

Measurement Principle Four wire measurement Accessories


Basic Accuracy + 1% of reading, + 5 digits
Standard
Memory Storage 500 reading storage facility 15 meter lead set with C Clamp 75mm opening
Computer Interface USB Master Earthing Cable (5 meter)
Mains power cord
Thermal Printer For printing the test results.
User Manual
Display Custom Built 3 ½ digit LCD Display with Backlit Calibration Certificate
Thermal Paper Role
Spare Fuse (3A/250V slow blow)
Physical Specifications

Enclosure Material Industrial grade Polypropylene Optional

Dimensions 365mm(L) x 465mm(W) x 185mm (H)


22 meter lead set with C Clamp 150mm jaw size
15 meter heavy duty lead set with alligator clip
Weight 24 Kg (Approx)
Software and USB Cord
Bluetooth application via cloud based
Power Supply Motware application

Mains 115V-230V, 50Hz / 60Hz Single phase AC supply


Note : To learn more about the Motware Application, check Page 91
Battery Rechargeable Li-ion

Power Consumption 35VA, 6.0 Watt on battery

Environmental
Operating Temperature 0°C to 55°C.

Storage Temperature 0°C to 50°C.

Humidity less than 95% RH, Non condensing

Safety Standards
Safety According to EN 61010 - 1

EMC According to EN 61326 - 1

IP Rating IP 54

Measurement Category CAT II

CE Certification LVD: 2006/95/EC

EMC Certification 2004/104/EC

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - PCRM-100SM 37

Features
100A True DC Test Current
Resistance Range : 200 µΩ with 0.1 µΩ
: 2000 µΩ with 1 µΩ
Direct mV Drop Reading
Internal Memory of 100 test
Dual Grounding Facility
Light weight & Portable
Rust Removing C Clamp

PCRM 100SM
Contact Resistance Meter

Applications
Stationary and moving contacts are built from alloys that
are formulated to endure the stresses of electrical arcing.
However, if contacts are not maintained on a regular basis,
Motwane's PCRM-100SM is True DC Contact resistance meter
their electrical resistance due to repeated arcing builds up,
designed for accurate and reliable result at a very reasonable cost.
resulting in a significant decrease in the contact's ability to
The instrument is based on Kelvin 4- wire connection method for
carry current and increase in resistance. Excessive
measurement of low resistance. PCRM 100SM has true 100A DC test
corrosion of contacts is detrimental to the breaker
current suitable for testing Circuit Breaker, Bus Bar, Isolator and Cable
performance. Hence to check contacts is to apply DC and
etc. PCRM 100SM has dual ground feature considering safety of
measure the contact resistance or voltage drop across the
operator and equipment. PCRM100SM is very light weight and
closed contacts. The use of a higher current value gives
portable with heavy duty test leads with C clamp and crocodile clips
more reliable results than using lower current values. The
to suit different applications.
resistance value is usually measured in micro ohms ( µΩ ).

PCRM-100SM is specially used to measure static contact


resistance of LV, HV, EHV circuit breaker contacts installed
in energised switchyards. High accuracy and repeatability
makes it a reliable tool for Quality Assurance and easy
operation makes it a very handy tool for quick maintenance
checks in various industries.

Typical resistance measurement applications are

Circuit Breaker contact resistance


Bus Bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-100SM 38

Accessories
Technical Details PCRM 100SM
Standard

15 meter lead set with C Clamp 75mm opening


Master Earthing Cable (5 meter)
Mains power cord
Technical Specification
User Manual
Test Current Injection 100A DC Calibration Certificate
Range & Resolution 200µΩ with 0.1 µΩ Spare Fuse (3A/250V slow blow)
Carry Case
2000 µΩ with 1 µΩ
Optional
Basic Accuracy + 2% of reading, + 1 digits
22 meter lead set with
(From 10% of the range)
C Clamp 50mm jaw size
Measurement Principle Four wire measurement
C Clamp 100mm jaw size
Display 3 ½ LCD with Backlit C Clamp 150mm jaw size

Memory Storage 100 Test Heavy duty crocodile clip 32mm Jaw Size.
15 meter Cable (heavy crocodile clip 32mm Jaw opening)

Physical Specifications
Dimensions 320 mm(L) x 435 mm(W) x 188 mm(H)

Weight 19.5 Kg Approx

Power Supply

Mains 115V-230V, 50Hz / 60Hz Single phase AC supply

Power Consumption 35VA

Environmental
Operating Temperature 0°C to 50°C.

Storage Temperature 0°C to 55°C.

Humidity less than 95% RH, Non condensing

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - CRM100A 39

Features
Continuously selectable Current In steps of 10, 20,
50 & 100A resp.
Digital Resistance Reading from 0.1μΩ to 20mΩ.
Simultaneous Display of Test Current, Resistance
Minimum Resolution of 0.1μΩ
Accuracy + (0.5% +5 digits)
3 1 ⁄ 2- digit readings for resistance.
Custom built backlit LCD with sealed soft touch
membrane keypad.
Data Exchange to PC through USB Interface.
Built-in Memory to store up to 99 test results.
Test 'ON' indicator with LED & beep, provided to signify
the flow of Direct Current DUT.

CRM 100A
Contact Resistance Meter

Applications
Stationary and moving contacts are built from alloys that
are formulated to endure the stresses of electrical arcing.
The Motwane's Contact Resistance Meter- CRM 100A is a digital However, if contacts are not maintained on a regular basis,
micro ohmmeter, designed to measure extremely low resistance. The their electrical resistance due to repeated arcing builds up,
instrument is based on the proven 4-wire measurement method for resulting in a significant decrease in the contact's ability to
low resistances to eliminate the effect of lead resistance of two wire carry current and increase in resistance. Excessive corrosion
method. The instrument is designed to replace complex bridge set up of contacts is detrimental to the breaker performance.
with a single compact unit. The DC current injection in continuously Hence to check contact, apply DC and measure the contact
adjustable between 10A to 100A. The testing information is displayed resistance or voltage drop across the closed contacts. The
on large LCD with backlit, real time data is displayed during the test use of a higher current value gives more reliable results than
using lower current values. The resistance value is usually
ON condition. The instrument gives a high resolution of 0.1 μΩ on 200
measured in micro ohms (μΩ).
μΩ resistance range.
CRM 100A has a large application for direct and indirect
The instrument is easy to operate and user friendly. Accessories are
measurements in various industries and manufacturing
rugged and come with heavy duty clips for better grip on test object.
facilities. High accuracy makes it a reliable tool for Quality
The kit and accessories are housed in a trolley mounted casing for
Assurance and easy operation makes it a very handy tool for
easy transportation. Advanced Dot Net based software is provided
quick maintenance checks for process industries.
for data downloading, analysis and report generation. The instrument
can be operated through software from a remote location. Internal
memory is provided for onsite data storage. Typical resistance measurement applications are

Circuit Breaker Contact Resistance in non-energized areas


Electrode Resistance Measurement
Bus Bar joints
Isolator Contacts
Cable Drum Resistance Measurement
Cable Splice
Weld Joints
Bond Resistance
Contact Resistance/Low Resistance Meter - CRM100A 40

Safety Standards
Technical Details CRM 100A
Safety : According to EN 61010 - 1

EMC : According to EN 61326 - 1

Power Supply
Accessories
Standard
Input Power 230V+ 10%, 50 Hz, 1 Phase
Output lead Set 4 X 5m
DC Test Current 10A, 20A, 50A & 100A
Mains Power Cord
Accuracy +0.5% + 5 digits
Mains Protection fuse 5A
Resolutions 0.1 A User Manual

Open Circuit Voltage 5V DC Calibration Certificate


Carrying Case
0/P Power 500 VA
Optional

Software CD
Resistance Measurement
USB Cord
Resistance Ranges 200µΩ 2m Ω 20mΩ

Resolution 0.1μΩ 1μΩ 10μΩ

Accuracy +(0.5% + 5 digits)

Operation Time
Continuous Operation up to 50A

4 minutes-ON and 10 minutes-OFF for 100A

Display 3 ½ digit Large LCD Display

PC interface USB for data transfer

Warning
Audio Visual Indication for Test ON Operation

Indication on Mains ON Operation

Blinking display for Over range indication

Environment
Operating Temperature 0°C to 55°C

Storage Temperature -10°C to 55°C

Humidity < 90% RH, Non condensing

Physical

Dimensions 365 mm(D) x 426 mm(W) x 178 mm(H)

Weight 12 Kg (Approx)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.

Note : Do not use this instrument in HT switchyard


Micro Ohm Meter - LR 2065S 41

Features
4.3” Color TFT display with backlit
Resolution 0.1 μΩ on 2 mΩ range
Best Measurement Accuracy of +0.03 %
Mains cum Battery operated.
High measurement current (10A) for faster settling of
measured values on low resistance.
True 4 wire resistance measuring technique
Pulse Mode, Auto Hold Operation.
Bluetooth interface and cloud connectivity through
Motware app
Inbuilt thermal paper printer
Low Battery indication to prevent deep discharge of
internal recharging battery.
Temperature Measurement & Correction

Connected to Cloud

LR2065-S
Micro Ohm Meter

CAT III IP Applications


600V 54 High Precise micro ohmmeter used for measuring accurate
low resistance with high accuracy, makes it a reliable tool
Motwane's Digital micro ohm meter LR2065-S with maximum 10A DC for Quality Assurance, easy operation and also makes it a
current injection is useful for the measurement of very low resistance very handy for quick maintenance checks for process
industries. Typical It is very useful in design, test,
in micro Ω as low as 0.1 μΩ. Mains cum rechargeable battery operated
maintenance, QC/QA and production. Typical applications
LR2065S, works on the proven principle of 4-wire measurements. The
include the measurement of
LR 2065S is having 4 digit LCD display with resistance measurement
range from 2mΩ to 20KΩ, with minimum resolution of 0.1μΩ. The pulse Cables
mode operation is an additional feature. The LR2065S can be used for Components
measuring resistance of cables, wires, PCB Relays, LT bus-bar, Relays
Graphite electrode, Quality testing of resistive components, Low PC Boards
capacity motors etc. Bus Bars

LR2065S has Bluetooth connectivity module with Motware mobile Contactors

app for remote access of testing data & storage at cloud for further Low rating motors & transformers
analysis & record purpose. Weld Joints
Electrodes
Micro Ohm Meter - LR 2065S 42

Safety
Technical Details LR2065S Measurement Category: CAT II (1000V)/CAT III (600V)
Reinforced insulation
Relevant Standard Specifications: Safety According to
EN 61010-1,EMC According to EN 61326-1

Printer Built in Thermal Printer


Accessories
PC Interface USB
Standard
Report Storage 1000 Reports
Test Lead set with Crocodile clip 2 meter : 1 Set.
Temperature correction Manual entry or Temperature Probe
Test Lead set with Kelvin clip 2 meter : 1 Set.
Temperature Channel 1 Mains Power Cord : 1 No.
Mains Protected Fuse : 1 No.
Dimensions 368 mm(L) X 283 mm(W) X 188 mm(H)
Thermal Paper roll : 1 No.
Net Weight 6.0Kg Approx. Instruction Manual : 1 No.
USB cable : 1 No.
Temperature measurement probe : 1 No.
Environmental Pen Drive for PC Software : 1 No.

Operating Temperature 0
0 C to 55 C 0

Note : To learn more about the Motware Application, check Page 91


Storage Temperature -100C to 600C

Relative Humidity 95 % RH at 400C max. (Non Condensing)

Power
Mains Power Supply Mains Input Voltage 110/230 Volt AC, 50/60Hz

Battery Power Supply Li-Ion Battery 14.8 V

Electrical Specifications
Test Current Injection 10A, 1A, 100mA, 10mA, 1mA, 100μA

Test ON Alert BEEP

Resistance Range

Max MAX ACCURACY


Range Resolution
Reading CURRENT ± (%RDG + DIGITS)

2mΩ 1.9999mΩ 0.1μΩ 10A ± 0.03 % of reading ± 4 digits

20mΩ 19.999mΩ 1μΩ 1A ± 0.03 % of reading ± 4 digits

200mΩ 199.99mΩ 10μΩ 100mA ± 0.03 % of reading ± 4 digits

2Ω 1.9999Ω 100μΩ 10mA ± 0.03 % of reading ± 4 digits

20Ω 19.999Ω 1mΩ 100mA ± 0.03 % of reading ± 4 digits

200Ω 199.99Ω 10mΩ 10mA ± 0.03 % of reading ± 4 digits

2000Ω 1999.9Ω 100mΩ 1mA ± 0.03 % of reading ± 4 digits

20KΩ 19999mΩ 1Ω 100μA ± 0.03 % of reading ± 4 digits

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - LR 2045S 43

Features
Back-EMF Protection
Best Measurement Accuracy of 0.05% + 5 dgt
Resolution 1 μΩ on 20 mΩ range
Inbuilt Thermal Paper Printer
Temperature Measurement & Temperature Correction
Feature.
4.3“ Colour TFT Digit Large And Clear Display
Accurate & Stable Readings
Pc Interfacing With Software
4 Wire Measurement Method
Sealed Soft Touch Membrane Keypad
Bluetooth Interface And Cloud Connectivity Through
Motware App

Connected to Cloud

LR 2045S
Micro Ohm Meter

Applications
Hot & Cold Winding Resistance Measurement of Motors,
The Motwane LR 2045S capable of measuring low resistance with 1
Generators, Alternators, and Transformers.
micro-ohm resolution. It employs the proven 4-wire (4W)
Contact Resistance Measurement of Fuses and
measurement where fixed DC current is supplied to DUT and voltage
Miniature Circuit Breakers.
drop across the DUT is measured and displayed as proportional
Resistance Measurement of Cables & Wires.
resistance reading. The meter is able to deliver guaranteed stable
readings on inductive as well as resistive loads.
Contact Resistance/Low Resistance Meter - LR 2045 44

Safety
Technical Details LR 2045S Measurement Category: CAT II (1000V)/CAT III (600V)
Reinforced insulation
Relevant Standard Specifications: Safety According to
EN 61010-1, EMC According to EN 61326-1

Technical Specification Protection


Display 4.3” Color TFT with backlit Protection against EMF : 12KV-(1.2/50µ sec.pulse).
Instrument Protected against mains overload
Temperature correction Range 0 to 100 deg,
(Fuse 250mA)
Accuracy + 1 deg, Resolution 0.1deg. All ranges are fuse protected. (Input fuse 1A).

Temperature Channel 1
Physical Specifications:
Printer Built in Thermal Printer
Dimensions : 360.68 mm (L) X 289.56 mm (W) X 165.1 mm (H)
PC Interface USB Net Weight : 8.0kg (Approx)

Report Storage 1000 Reports

Accessories
Indications
Standard
4.3” Color TFT with backlit or range and Ω/mΩ indications.
Test Lead set 10meter : 1 Set.
LED indication for operation and pulse mode. Mains Power Cord : 1 No.
Mains Protected Fuse : 1 No.
Over range indication: Blinking zero display.
Thermal Paper roll : 1 No.
Under Range Indication: All Display shows zero. (Not blinking) Instruction Manual : 1 No.
Calibration Certificate : 1 No.

Optional
Technical Specifications :
USB cable : 1 No.
MAX ACCURACY Temperature measurement probe : 1 No.
Range Resolution
CURRENT ± (%RDG + DIGITS)

20mΩ 1μΩ 1A ± 0.05 % of reading ± 5 digits Note : To learn more about the Motware Application, check Page 91

200mΩ 10μΩ 1A ± 0.05 % of reading ± 5 digits

2000mΩ 100μΩ 100mA ± 0.05 % of reading ± 5 digits

20Ω 1mΩ 10mA ± 0.05 % of reading ± 5 digits

200Ω 10mΩ 1mA ± 0.05 % of reading ± 5 digits

2000Ω 100mΩ 100uA ± 0.05 % of reading ± 5 digits

Note : Accuracies are valid from 1/10th of the range to FS of range & valid

Temperature 25°C + 3°C at 55% + 10%RH.

Temperature Coefficient 100ppm/°C.

Open Circuit Voltage 15Volt ± 3volt.

Power Supply Mains Input Voltage115/230VAC,

50/60Hz

Environmental Specifications:

Operating Temperature 0°C-55°C.

Storage Temperature 10°C -60°C.

Relative Humidity 95 % RH at 400C max.

(Non Condensing)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - HVT Series 45

Features
Variable Output Voltage AC/DC/AC+DC
Selectable Trip Current
Zero Start Interlock
Timer to set duration of test
Audio/Visual Indications
Overload Protection
High Leakage Current Range
Supply Fault / Earth Open Interlocking Door / Cabin
Door Interlock
Wheel mounted for easy transportation

Applications
Dielectrics (insulation) for electrical equipment and
apparatus is used for many different applications. It is
expressed for a wide range of environmental conditions
HVT Series such as temperature, moisture, chemicals, other
AC-DC Hi Pot Test Set contaminants, and exposure to weather. One major factor
affecting insulation life is thermal degradation, although
moisture, contamination, voltage stress, and other factors
The Motwane's Hi-Pot Tester, HVT series offers a wide range of test
may also contribute to its degradation. In addition, the life of
voltages to determine the withstand strength of electrical insulation
an insulating material depends on the degree of loading, the
for the normally occurring over voltage transients. HVT series sets
type of service to which the equipment is subjected, the
are available in a wide range of voltage and power ratings with
care it receives during installation and operation, and
exceptional reliability, durability and functionality which can
mechanical vibration and forces to which it is subjected.
generate AC, DC or AC+DC voltages (eliminates the need of two
separate kits). Available with manual / motorized controlled A dielectric withstand test is an electrical test performed on
operation provides variable output voltage. Test sets had selectable a component or product to determine the strength of
tripping current to identify breakdown voltage of different test insulation. Voltage applied between equally insulated
objects and also have timer, useful to set duration of test period. HVT sections of a part or energized parts and electrical ground
series is provided with HV indication, supply fault / earth open under test and determining the leakage current that may
interlocking & door / cabin interlocking & overload protection flow under test conditions. Excessive leakage current flows
provided for safety of operator & test set. may indicate a deteriorated condition or impending failure
of the insulation. Insulation testing can be performed by
applying either direct current (DC) voltage or alternating
current (AC) voltage The test to qualify a device's ability to
operate safely during rated electrical conditions. If the
current through a device under test is less than the specified
limit at the required test potential and time duration, the
device meets the dielectric withstand requirement. A
dielectric withstand test may be done as a factory test on
new equipment, or may be done on apparatus already in
service as a routine maintenance test.

Typically used for


Transformer/Motor/ Generator/Switchgear testing
Insulated Electric Apparatus & Components
Power Cables.
Aerial Lift Equipment/Bucket Trucks
Domestic appliance testing
Capacitor Coils & chokes
Protection Testing - HVT Series 46

Technical Details HVT Series

Technical Specification

MOT- MOT- MOT- MOT- MOT- MOT- MOT- MOT-


Model
HVT5 HVT10 HVT15 HVT20 HVT30 HVT40 HVT50 HVT70

Output Voltage 5KV 10KV 15KV 20KV 30KV 40KV 50KV 70KV

Tripping Current Options 1) 50mA or 2) 100mA, Selectable at (25%-50%-100%) of full range

Burden at 50mA 0.25KVA 0.5KVA 0.75KVA 1KVA 1.5KVA 2KVA 2.5KVA 3.5KVA

Burden at 100mA 0.5KVA 1KVA 1.5KVA 2KVA 3KVA 4KVA 5KVA 7KVA

Type of Voltage AC/DC/AC+DC

Display (V/I/T) Digital Meter

Voltage Meter 0.-5KV 0.-10KV 0-15KV 0-20KV 0-30KV 0-40KV 0-50KV 0-70KV

Voltage Accuracy +2% of full scale reading +2 digits

Voltage Resolution 0.1KV

Current Accuracy +2% of full scale reading +2 digits

Mains Supply 230 V +10%, 1 Phase AC, 50/60 Hz

Duty Cycle 15 min On, 10min Off

Timer 0-999 seconds Digital Timer

Time Accuracy +0.05% of full scale reading

Operation Mode Manual Motorized

Colling Type Air cooled

Indication Bright LED for Power ON & Test ON

Protected by MCB,
Protection and
Fuse Zero Start Interlock
Safety
Earth Open/ Supply Fault Interlock, Door/ Cabin Interlock

Operating
0-55°C, 5-90% RH Non Condensing
Temperature

*We also provide customized High voltage test set as per requirement

Ordering Information

Model Products Detail Accessories


MOT-HVT5 5KV High Voltage Tester Standard

MOT-HVT10 10KV High Voltage Tester Grounding Cable


Instruction Manual
MOT-HVT15 15KV High Voltage Tester
Warranty Certificate
MOT-HVT20 20KV High Voltage Tester Calibration Certificate
MOT-HVT30 30KV High Voltage Tester Non shielded HV Cable
Spare Fuse
MOT-HVT40 40KV High Voltage Tester
Optional
MOT-HVT50 50KV High Voltage Tester
Interconnecting Cable
MOT-HVT70 70KV High Voltage Tester Discharge Rod
Note: while ordering need to mention 1) Type of voltage : AC, DC or AC-DC
2) Tripping Current : 50mA or 100mA

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes continuous improvement of its product. We, therefore,
reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - MOT-RTS 47

Features
Compact unit with rugged case
Variable model and selectable Output Current
up to 200A/600VA
Output Voltage 0-250V AC/DC
Auto Cut-Off upon Tripping Relay
Timer Range 0.0001-9999 Seconds Auto Ranging ,
Digital Timer with Accuracy +0.05% + 2 Counts
Wheel mounted for easy transportation

MOT - RTS
Relay Test Set

The Motwane's RTS Series also known as kit is a portable, cost Applications
effective is portable cost effective solution to test voltage & current
The secondary current injection test of solid-state units
based relays. It is designed with highly accurate digital meters for
can be performed by a specially designed power supply
testing of protective devices. The MOT-RTS set provides high burden
unit. Secondary injection tests are always done prior to
to test electromechanical relays. RTS Series can provide up to 200A
primary injection tests. The purpose of secondary injection
for CT, MCB Testing. The compact & rugged design makes it easy to
testing is to prove the correct operation of the protection
move in relay room.
scheme that is downstream from the inputs to the
protection relay(s). This is because the risks during initial
testing to the LV side of the equipment under test are
minimized. It should be noted that the secondary current
injection method only tests the solid-state trip unit logic
and components like relay, miniature breaker etc.

Over Current Relay


Undercurrent Relays
Over voltage Relays
Under Voltage Relays
Thermal Relays
Earth Fault Relays
Electromechanical Relays
Miniature Circuit breaker etc.

Ordering Information
MOT-RTS10/200 10A Relay Test Set

MOT-RTS20/200 20A Relay Test Set

MOT-RTS50/400 50A Relay Test Set

MOT-RTS100/600 100A Relay Test Set

MOT-RTS200/600 200A Relay Test Set


Protection Testing - MOT-RTS 48

Technical Details MOT - RTS

Technical Specification

MOT- MOT- MOT- MOT- MOT-


Model
SIK10 SIK20 SIK50 SIK100 SIK200

Output Current 0-10A 0-20A 0-50A 0-100A 0-200A

Selectable Current
0-1-5-10-25-
Ranges (O/P current 0-1-5-10A 0-1-5-10-20A 0-1-5-10-25-50A 0-1-5-10-25-50-100A
display on % Ammeter)
50-100-200A

Burden 200VA 400VA 600VA

O/P DC Voltage 0-250V DC

O/P AC Voltage 0-250V AC

Voltage Accuracy +1.5% of full scale reading +2 digits

Voltage resolution 1V

Current Accuracy + 1.5% of full scale reading + 2 digits

Current Resolution 1% of full scale

Timer Range 0.0001-9999 Seconds Auto Ranging ,Digital Timer

Timer Accuracy +0.05% +2 Counts

Duty Cycle 30 Min ON, 10 Min OFF

Mode of Operation Manual

Display LED Seven Segment Digital Display Meters

Indications Bright LED for Power ON & Test ON

Mains Supply 230 Vac +10%, 1 Phase, 50/60Hz

Protection and Safety Fast blow glass fuse Over current tripping

Operating Temperature 0-55°C, 5-90% RH Non Condensing

PVC insulated 2.5 sq. PVC insulated 10 sq. mm PVC insulated 16 sq. PVC insulated 25 sq. PVC insulated 50 sq.
Output Current leads mm cu cables 2X1.5mtr cu cable 2X1.5mtr lug mm cu cable 2X1.5mtr mm cu cable 2X1.5mtr mm cu cable 2X1.5mtr
lug at both ends at both ends lug at both ends lug at both ends lug at both ends

*We also provide Customized RTS as per requirements

Accessories
Standard

Lead sets Short Link

PVC insulated output current lead set - 1set Spare Fuse

PVC insulated 2.5 Sq.mm Cu cable 2 corex4 mtrs one Calibration Report

side banana plug & other side small crocodile clip - 1 no Warranty Certificate

PVC Insulated 1.5 Sq.mm Cu Cable 2 core x 4 mtrs one

side banana plug & other side small crocodile clip - 2 no

Mains Power Supply Cord

Instruction Manual

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - PIK Series 49

Features
Variable Output Current
High VA burden to test high impedance objects
Digital timer for measuring tripping time
Zero Start Interlock for safety
Auto Cut-Off upon Tripping Relay
Current range ( Low - 50% & High - 100% of full range )
CT sec current measurement (Optional)
CT Polarity Detection (Optional)
Wheel mounted for easy transportation

PIK Series Applications


Primary Current Injection Kit.
The primary current injection method is usually a preferred
method to verify the current sensors, wiring, and the current
The Motwane's Primary Current Injection kit MOT-PIK series is most conduction path in the breaker. In order to identify sensor
reliable & effective kit for testing & commissioning of protecting and wiring related problems, it is recommended that the
system in electrical substation. The PIK series offer high output primary current injection test is to be conducted separately
current up to 3000 Amps with relatively high burden up to 20kVA. It on each phase through current transformer that ensures
is designed with user friendly features to check operations of that the sensors and wiring of the breaker are working
protection component system including Current transformer, Circuit proper.
Breaker, Current Sensor and Relays The Motwane PIK with high VA
The primary current injection method is also useful for
burden makes it possible to deliver desired current to high impedance
testing current transformer ratio. The secondary current of
object like Current transformer. It has optional feature to measure CT
the transformer bears a known relationship with the primary
secondary current as well as polarity.
current. Any change in the primary current is reflected in the
secondary circuit. To verify the turns ratio and polarity tests
Ordering Information on CT, current injected on primary side of CT and measured
at secondary side of CT for relaying to ensure that they have
MOT-PIK200/1 Primary Current Injection Kit : 200A with 1kVA Burden the correct turn's ratio and relaying accuracy.

MOT-PIK500/3 Primary Current Injection Kit : 500A with 3kVA Burden


High current injection (primary current) used is recom-
MOT-PIK800/5 Primary Current Injection Kit : 800A with 5kVA Burden mended during commissioning of protection systems and
also recommended during major repairs and component
MOT-PIK1000/5 Primary Current Injection Kit : 1000A with 5kVA Burden
replacement in power substations.
MOT-PIK1500/10 Primary Current Injection Kit : 1500A with 10kVA Burden
Motwane's Primary Current Injection Kits are used to test
MOT-PIK2000/15 Primary Current Injection Kit : 2000A with 15kVA Burden Current Transformers, Circuit Breakers, Bus Bars, Relays,

Primary Current Injection Kit : 2000A with 15kVA Burden


MCBs, MCCBs etc.
MOT-PIK2500/15

MOT-PIK3000/20 Primary Current Injection Kit : 3000A with 20kVA Burden Optional Features

Measurement of CT sec current & Polarity


Auxiliary variable AC/DC voltage 0-250V
Measurement of Open Circuit Voltage of o/p
current terminals

Warranty: Standard one year warranty against any


manufacturing defects.
Protection Testing - PIK Series 50

Technical Details PIK Series

Technical Specification

MOT- MOT- MOT- MOT- MOT- MOT- MOT- MOT-


Model
PIK200 PIK500 PIK800 PIK1000 PIK1500 PIK2000 PIK2500 PIK3000

Output Current 0-200A 0-500A 0-800A 0-1000A 0-1500A 0-2000A 0-2500A 0-3000A

O/P Accuracy +1.5% of full scale reading + 2 digits

O/P Resolution 1A

Burden at 100mA 5V 6V 6.25V 5V 6.67V 7.5V 6V 6.67V

Burden 1KVA 3KVA 5KVA 5KVA 10KVA 15KVA 15KVA 20KVA

Timer 0.0001 to 9999 sec Auto ranging, Digital timer

Timer Accuracy +0.05% +2 counts

Mains Power Supply 230Vac +10 %, Single Phase, 50/60Hz

Operation Mode Manual Motorized

Duty Cycle 10 min On, 20 min Off

Display LED Seven Segment type Digital Display

Indication Bright LED for Test ON and Power ON operation

Protected by MCB & Fuse


Protection & Safety Zero Start Interlock
Over Current Tripping

Unit Combined control & loading unit Separate control & loading units

Operating Temperature 0-55°C, 5-90% RH Non Condensing

Standard 50 mm2 120 mm2 180 mm2 240 mm2 400 mm2 480 mm2 600 mm2 720 mm2
Output Cables (2X5) meters (2X5 ) meters (2X5 ) meters (2X5) meters (2X7) meters (2X10) meters (2X10) meters (2X10) meters

*We also Provide customized Primary Injection kit as per requirement

Accessories
Standard Optional

Test Lead set : pair of cotton braided copper C - clamp

Cables with lugs at both end Interconnecting cables

Mains Power Supply Cord

Spare Fuse

Short Link

Instruction Manual

Calibration Certificate

Warranty Certificate

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
High Voltage Detectors 51

Features
Non-contact / Contact type Detectors.
Type tested at CPRI/ERDA
Complies IS 2071 (Part-I) and IS 13770: 1993 for FRP
Sectional Hot Stick Rod.
Available in FRP Telescopic Rod / FRP Sectional Hot Stick
Rod in 1.2 / 3 / 5 mtr.
Colour Code models for different voltage levels.
Indicates presence of High Voltage by Audio
Annunciations as well as Visual Indications.
Bright high intensity red LED's provide clear visual
Bullet even in unfavourable daylight conditions.
A Buzzer produces a loud beep which is audible even in
noisy backgrounds.
Supplied as a complete kit with HV Detector, Telescopic
Fibre Glass Insulation stick and ergonomically designed
sturdy carry bag.
Self test button to test battery and proper functioning
of HV detector.
Powered by a single 9V battery type (6F22), easily
replaceable on field.

High Voltage Detectors


The Motwane HV Detector series provide an exceptional combination Applications
of user comfort and safety in one electrical safety device. The
Useful for Utility, Industrial, Railway and for Mine Safety
optimum LED layout, integrated audible signals and innovative self-
applications like following.
test features form the basic elements on all voltage detection
equipment types. HV Detector series are designed in contact type Contact/Non-contact detection of live voltages.
and non-contact type. The HV detectors are used to check for the Check and detect live high voltage cables.
absence or presence of voltage on medium and high voltage Trace live wires
switchgear, transformers or overhead lines – electrical safety is
Detect residual or induced voltages.
imperative in all areas of power transmission and distribution at all
voltage levels including MV, HV and EHV up to 400kV (suitable for 11
kV/ 33 kV / 132 kV / 220 kV/ 440 kV supply lines). It is available in FRP
Telescopic Rod/FRP sectional hot stick. Powered by a single 9V
battery. The HV detector starts annunciation with flashing red LED's
and buzzer beeps indicating that the line is live and not safe to earth
before carry any operations. HV Detector series is easy to use, hence
jobs get done more quickly and safely. Reliably detecting high
voltage on distribution and transmission voltage power lines is critical
jobs performed by electric utility linemen.

Non Contact Type Probe.

LEDs for Visual


Indication

Universal Link
High Voltage Detectors 52

Technical Details High Voltage Detectors

Technical Specification

Model HV50P HV50 HV132 HV220 HV440

Voltage Range 230V - 33kV 3.3kV - 33kV 11kV - 132kV 33kV - 220kV 66kV - 440kV

Type Non Contact Non Contact Contact/Non Contact Contact/Non Contact Non Contact

Sensing Distance - - 1mtr - 3mtr - 5mtr 1mtr - 3mtr - 5mtr 1mtr - 3mtr - 5mtr

General Specifications
High Voltage Indication

RED LEDs start flashing with an audible buzzer if taken into High Voltage induction area.

Electrical Specifications

Insulation Resistance Greater Than 100M Ohms by 1KV I.R. Tester.

Dielectric Strength Equivalent or greater than as per model selected.

Power Specifications Universal Link


Current Consumption 30mA maximum Material Glass Filled Nylon

Battery Low 7.2 V Nominal Length 95mm Approx

Battery 9V / Battery type 6F22 or equivalent Insulated Stick

Visual Indication High Bright LEDs flashing Material Fibre Glass (Sturdy & Rugged)

Audible Indication Buzzer beeps Loudly Length Telescopic Extendable length 3 mtrs.

for 33 KV & 5 mtrs. for 132 KV & above.

Environmental Specifications
Recommended Operating Physical Specifications
Temperature Range 5°C to 50°C Length 245mm Approx.

Humidity <85% RH non-condensing Diameter 105mm Approx

Storage Temperature 10°C to 60°C, Weight Approx. 2.5Kg.including

<85% RH non-condensing Range Telescopic Insulated Stick.

Accessories
Standard

FRP Telescopic Rod 1.2 / 3 / 5 metre OR

FRP sectional hot stick Rod 1.2 / 3 / 5 metre (Optional)

Carrying Bag

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Earth/Ground Tester - DET20 53

Features
3 ½ digit LCD Display with max reading 1999.
3 terminal and 4 terminal Measurement Method
Earth Resistance Range 0.01Ω to 1999Ω
4 Soil Resistivity Measurement
Rechargeable Internal Ni-MH Battery
Earth Measurement Voltage up to 200V
Ratio Metric Synchronous Rectification

Applications
The integrity of the grounding system is very important in
an electrical power system for the following reasons:

To maintain a reference point of potential (ground) for


DET 20 equipment and personnel safety. To provide a discharge
point for travelling waves due to lightning. To prevent
Digital Earth Tester
excessive high voltage due to induced voltages on the
power system
DET 20 is a conventional type 3 digit LCD display which is designed to
Therefor to maintain sufficiently low resistance values of
measure Earth Resistance, Soil Resistivity & Earth Voltage. It has a
grounding systems, their periodic testing is required. The
unique RSR technology in which even at the drop of battery voltage
testing involves measurement to ensure that they do not
the measurement reading remain constant. DET 20 has 128Hz test
exceed design limits.
frequency which eliminates the harmonics interference and has
rechargeable long-life battery which reduces the cost of battery. The measurement of ground resistances may only be
Earthresistance is measured by three wires & Soil Resistivity is accomplished with specially designed test equipment. The
measured by four wire measurement techniques. This meter is shock most common method for measuring ground resistance
proof, drop and dust proof. It has ABS casing which is useful for heavy uses the fall-of-potential principle of alternating current
duty. DET 20 is Type tested as per IS 9223. (AC) at higher frequency circulating between an auxiliary
electrode and the ground electrode under test; the reading
will be given in ohms and represents the resistance of the
ground electrode to the surrounding earth.

Soil Resistivity is also the key factor that determines what


the resistance of a grounding electrode will be, and to what
depth it must be driven to obtain low ground resistance. The
resistivity of the soil varies widely throughout the world and
changes seasonally. Soil Resistivity is determined largely by
its content of electrolytes, consisting of moisture, minerals,
and dissolved salts. A dry soil has high resistivity if it
contains no soluble salts. It figures has a direct impact on the
overall sub-station resistance and how much earth electrode
is required to achieve the desired values. Lower the
resistivity, fewer the electrodes required to achieve the
desired earth resistance value. Hence the Soil Resistivity is
also important test.

The methods of measuring and testing the Earth


Resistance and Soil Resistivity:

3 pole method used for Earth Resistance testing


4 pole method used for Soil Resistivity testing.
Earth/Ground Tester - DET20 54

Accessories
Technical Details DET 20
Standard

4nos. Spike of 10mm dis, 450mm long


10m, 20, 30m &40m of measurement cable
on a winder as standard.
Earth Resistance Ranges Battery Charger
0.01Ω to 19.99Ω Hammer
Carrying bag
0.1Ω to 199.9Ω
Instruction Manual
1Ω to 1999Ω

Accuracy (250C +50C)


Typically used for
+1.5% of reading +5 digits valid from 10% of reading to 95% of range.
Standard
Earth Voltage accuracy : 2% of Range
Substation Earth Testing.
Earth Voltage resolution : 0.1V
To test telecom tower grounding, Railways Earthing.
Test Frequency 128Hz ±0.5Hz To test the quality of grounding without disconnecting
the ground rod under test.
Test Current
Earth Resistance of Grid.
20 Ω Range : 10mA AC rms

200 Ω Range : 1mA AC rms

2000 Ω Range : 100mA AC rms

Test Current us generally constant throughout the range

Power Supply Internal, rechargeable Ni-MH 1.2V, 600mAh x 8nos.

Charging Time Recommended 16hrs.

Single Charge Battery life Approximately 5-6hrs of continuous

operation on mid-range.

Interference

Interference voltage of 20V +5% peak to peak, 50Hz in the potential circuit will

have a maximum effect +1% on the reading obtained form 20 Ω to 2KΩ ranges.

Influence of Temperature
<+0.2% per0 C over the temperature range 0-200C and 28-550C.

Temperature Range
Operating : 00C to +550C <90% RH

Storage : -200C to +700C <90% RH

Humidity

Operating : 95% RH non condensing max at 400C

Storage : 93% RH non condensing max at 550C

Flash Test : 2KV AC

Voltage withstand
In the event of as system fault, the instrument will withstand 240V AC, applied

between any two terminals.

Dimensions 180mm(L) x 100mm(W) x 54mm(H)

Weight 550gms without accessories.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Earth/Ground Tester - DECT 3 55

Features
Clamp-on Ground Resistance Tester
55*32mm jaw size for larger ground rods.
Autoranging ground resistance measurement from 0.01
to 1000 ohms with 0.001-ohm resolution
AC leakage current range from 0.05mA to 30A with
0.05mA resolution.
Configurable alarm value in resistance and current to
support your measurement
Ergonomic mold, full rubber coating, and hand strap for
slip-proof
Datalogging with 99 data points
Verification resistor confirms the accuracy of the meter
Complete with heavy-duty case and verification resistor

DECT 3
Digital Clamp on Earth Resistance Tester
Applications
Motwane's new Digital Clamp on Earth resistance Tester, DECT-3
Clamp on measurement method is new and quite unique. It
measures earth resistance using clamp on technology. Clamp on is a
offers the ability to measure the Earth Resistance without
relatively new method of determining the quality of a ground system.
disconnecting the ground. This type of measurement also
DECT-3 can measure Earth Resistance, earth bonds measurement &
offers the advantage of including the bonding to ground
also measures AC leakage current. It's actually recommended to use it
and the overall grounding connection resistances and also
on sites where there are multiple grounds placed in parallel and not
indispensable troubleshooting tools to help you maintain
required to isolate the ground rod. Simply clamp around the
uptime. It is recommended that all grounds and ground
conductor or earthing strip and measure the Earth Resistance fast and
connections be checked at periodically as a part of normal
accurately. The unique big jaw is particularly suitable where
predictive maintenance plan. If there is an increase more
grounding is done by flat steels or copper strips. It has low battery
than the acceptable limit during these periodic checks, the
indication & data hold facility within built memory storage of up to 99
engineer should investigate the source of the problem and
test results. DECT-3 has got the double insulation level and is
make the correction to lower the resistance by replacing or
protected from external magnetic & electric fields.
adding ground rods to the ground system.

Typically used for


Measures Earth Resistance of the electrical ground
rod and grid.
Utility Poles/Service Entrance or Meter
Street Lighting
Lightning Protection
Street Cabinets
Telephone Pedestals and Telecommunication Tower's
grounding
Cell Towers (applications with buried ground ring)
Pad Mounted Transformer
Pole Mounted Transformer
Measures AC leakage current of transformer neutral.
Conduct field surveys fast and effectively and
retrieves & analyses the readings for later reference.
Earth/Ground Tester - DECT 3 56

Specification Range Resolution Accuracy

0.01Ω-0.099Ω 0.001Ω + (1% + 0.01Ω)

0.10Ω-0.99Ω 0.01Ω + (1% + 0.01Ω)

1.0Ω-49.9Ω 0.1Ω + (1% + 0.1Ω)

50.0Ω-99.5Ω 0.5Ω + (2% + 0.5Ω)


Earth Resistance
100Ω-199Ω 1Ω + (3% + 1Ω)

200Ω-395Ω 5Ω + (6% + 5Ω)

400Ω-590Ω 10Ω + (10% + 10Ω)

600Ω-880Ω 20Ω + (20% + 20Ω)

Min. Resolution 900Ω-1200Ω 30Ω + (25% + 30Ω)

0 mA - 9 mA 0.1mA + (2.5% + 1mA)

10 mA - 99 mA 1mA + (2.5% + 5mA)


Leakage Current
100 mA - 29.9 mA 1mA + (2.5% + 10mA)

0.30A - 29.9 A 0.1 A + (2.5% + 20mA)

Configurable alarm value of resistance 0.199Ω

Min. Resolution 50μA

Configurable alarm value of current 0-499mA

Measurement Leakage Current 45-65A, RMS

Memory 99 sets

Conductor Size 55mm x 32 mm

Working Temperature -100C - 550C

Working Humidity 10%-90%

LCD Size 28x46mm

Power Supply AA.1.5V x 4

Dimension 288mm (L) x 86mm (W) x 57 mm(H)

Weight Approx 960g (Battery Included)

Accessories
Standard
Standard Loop Resistance of 5.1Ω
Instruction Manual
Carrying Case
Calibration Certificate
USB

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes continuous improvement of its product. We, therefore,
reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.

Note : Color of Clamp May be variable Red or Green


Earth/Ground Tester - DECT 2 57

Features
CLAMP-ON GROUND RESISTANCE TESTER
65*32mm jaw size for larger ground rods
Autoranging ground resistance measurement from 0.01
to 1000 ohms with 0.001-ohm resolution.
Configurable alarm value in resistance and current to
support your measurement.
Ergonomic mold, full rubber coating, and hand strap for
slip-proof.
Datalogging with 99 data points.
Verification resistor confirms the accuracy of the meter.
Complete with heavy-duty case and verification resistor

DECT 2
Digital Clamp on Earth resistance Tester

Applications
Clamp on measurement method is new and quite unique. It offers the
Clamp on measurement method is new and quite unique. It
ability to measure the earth resistance without disconnecting the
offers the ability to measure the earth resistance without
ground. This type of measurement also offers the advantage of
disconnecting the ground. This type of measurement also
including the bonding to ground and the overall grounding
offers the advantage of including the bonding to ground
connection resistances and also indispensable troubleshooting tools
and the overall grounding connection resistances and also
to help you maintain uptime. It is recommended that all grounds and
indispensable troubleshooting tools to help you maintain
ground connections are checked periodically as a part of a normal
uptime. It is recommended that all grounds and ground
predictive is seen maintenance plan. If an increase in resistance of
connections be checked periodically as a part of normal
more than acceptable limit during these periodic checks, the engineer
predictive maintenance plan. If an increase in resistance of
should investigate the source of the problem and make the correction
more than acceptable limit during these periodic checks,
to lower the resistance by replacing or adding ground rods to the
then the engineer should investigate the source of the
ground system.
problem and make the correction to lower the resistance by
replacing or adding ground rods to the ground system.

Typically used for


Measures Earth Resistance of the electrical ground
rod and grid.
Utility Poles/Service Entrance or Meter
Street Lighting
Lightning Protection
Street Cabinets
Telephone Pedestals and Telecommunication
Tower's grounding
Cell Towers (applications with buried ground ring)
Pad Mounted Transformer
Pole Mounted Transformer
Conduct field surveys fast and effectively and
retrieves and analyses the readings for later reference.
Earth/Ground Tester - DECT 2 58

Specification Range Resolution Accuracy

0.01Ω-0.099Ω 0.001Ω + (1% + 0.01Ω)

0.10Ω-0.99Ω 0.01Ω + (1% + 0.01Ω)

1.0Ω-49.9Ω 0.1Ω + (1.5% + 0.1Ω)

50.0Ω-99.5Ω 0.5Ω + (2% + 0.5Ω)


Earth Resistance
100Ω-199Ω 1Ω + (3% + 1Ω)

200Ω-395Ω 5Ω + (6% + 5Ω)

400Ω-590Ω 10Ω + (10% + 10Ω)

600Ω-1000Ω 20Ω + (20% + 20Ω)

Min. Resolution 0.001Ω

Memory 99 sets

Conductor Size 65mm x 32 xx

Working Temperature -100C - 550C

Working Humidity 10%-90%

LCD Size 47x28.5mm

Power Supply AA.1.5V x 4

Dimension 293mm (L) x 90mm (W) x 60 mm (H)

Weight Approx 1320g (Battery Included)

Accessories
Standard
Standard Loop Resistance of 5.1Ω
Instruction Manual
Carrying Case
Calibration Certificate

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Multimeter - M63 59

Features
6000 Count LCD display with pleasant white backlit.
AC/ DC Current range upto 20A.
Resistance, Capacitance, Diode & Continuity
Measurement Facility.
Selectable Frequency & Duty Cycle Measurement.
60 position analog bar graph for trend indication.
Highly Linear Readings.
Select, Range, Hold/Light, Rel, Hz/duty.
Max/Min functions incorporated
Safety - CE, CAT IV(600V), IP 54, EN61326-1 & IEC 61010-1
Robust, Rugged & Double Mould Casing.

M63
Digital Multimeter Industrial Graded

CAT iV IP Applications
600V 54 Power Utility
Industries
The Motwane’s Terms Industrial Graded Digital Multimeter M63 is Electrical Contractor
specially designed in our research laboratory & went under stringent
Telecommunication
manufacturing process for a wide range of applications like Power
Railway
Generation, Power Distribution, Power Transmission, Steel Industries,
Defence
Cement Industries, Mining Industries, Power Electronics Industries,
Heavy Engineering Industries and Defence Sector & Aviation Sector.
M63 is a versatile and high-performance industrial grade multimeter
that complies with IEC 61010-1-2010 safety standards and excellent
noise immunity to disturbances from energized power lines, with CE,
CAT IV 600 V safety rating IP-54 protection.
Digital Multimeter - M63 60

Technical Details M63

General
Display 6,000 Count LCD display with white backlit.

Display Update Rate 3 times per second nominal.

Dimensions (WxHxD) 205mm(L) X 94mm(W) X 36 mm(H)

Weight 450g. Approx

Environmental

Environmental 0°C to 50°C

Relative Humidity 80% RH @ 5°C to 31°C

50% RH @ 31°C to 40°C Non condensing

Storage Temperature - 20°C to 60°C

Power
Power Supply 9V Battery Type 6F22 or equivalent

Power Consumption 4mA typical.

Low Battery Indication “ ” is displayed below 6.5V approx.

Auto Power OFF After 15 Min., Ideal sleep mode

consumption is 300µA approx. (Can be cancelled by pushing SELECT key before power on the meter).

Overload Protection:
Fuse Protection for ‘mA’ input terminal 0.75 A/ 0.8 A/ 500V fast blow type ceramic fuse.

Fuse Protection for 20A input terminal 20A/ 500V fast blow type ceramic fuse

Ω/ / / /Hz (%) 1000 V DC / AC rms

Safety

Directives for CE Certification LVD:2006/95/EC., EMC: 2004/104/EC

Measurement Category CAT IV, 600V Reinforced Insulation.

Relevant Standard Specification EN 61010-1:2010, EN61326-1:2006

IP Rating (Dust & Water Protection) IP54

Accessories

Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.

DC Voltage
Range Resolution Max. Reading Accuracy Overload Protection

600mV 0.1 mV 600.0 mV +(0.5% + 3)

6V 1 mV 6.000 V +(0.5% + 3)

60V 10 mV 60.00 V +(0.5% + 3) 1050V DC/AC rms

600V 100 mV 600.0 V +(0.5% + 3)

1000V 1V 1000 V +(0.8% + 3)

Note: Input Impedance 10MΩ approx.


Digital Multimeter - M63 61

Technical Details M63

AC Voltage (50Hz-500Hz)Trms
Range Resolution Max. Reading Accuracy Overload Protection

6V 1 mV 6.000 V +(1% + 5)

60V 10 mV 60.00 V +(1% + 5)

600V 100 mV 600.0 V +(1% + 5) 1050V DC/AC rms

750V 1V 750 V +(1.2% + 8)

Note : Input impedance : 10 MΩ approx. shunted by 60pF approx

DC ‘mV’ Range
Range Resolution Max. Reading Accuracy Overload Protection
60 mV 0.01 mV 60.00 mV +(0.5% + 3)
1000V DC/AC rms
600 mV 0.1 mV 600.0 mV +(0.5% + 3)

Input Impedance : 1000MΩ approx.

AC ‘mV’ Range (50Hz-1KHz) Trms


Range Resolution Max. Reading Accuracy Overload Protection
60 mV 0.01 mV 60.00 mV +(1% + 5)
1000V DC/AC rms
600 mV 0.1 mV 600.0 mV +(1% + 5)

Input Impedance : 1000MΩ approx.

DC Current Range

Range Resolution Max. Reading Accuracy Overload Protection


60 mA 0.01 mA 60.00 mA +(1% + 5) 0.75A/0.8A/ 500V DC/AC

0.1 mA 600.0 mA +(1% + 5) fuse protection


600 mA

6A 1 mA 6.000 A +(1% + 5)
20A/500V DC/AC

20 A 10 mA 20.00 A +(1.2% + 5) fuse protection

Note : 1. 10A for continuous 2. >10A for 20sec. after 15min. cool down interval

AC Current Range (50Hz-500Hz) Trms


Range Resolution Max. Reading Accuracy Overload Protection
60 mA 0.01 mA 60.00 mA +(1.2% + 5) 0.75A/0.8A/ 500V DC/AC

0.1 mA 600.0 mA +(1.2% + 5) fuse protection


600 mA

6A 1 mA 6.000 A +(1.2% + 5)
20A/500V DC/AC

20 A 10 mA 20.00 A +(1.5% + 5) fuse protection

Note : 1. 10A for continuous 2. .>10A for 20sec. after 15min. cool down interval

Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection
600 Ω 0.1 Ω 600.0 Ω +(0.5% + 3)
6 KΩ 1Ω 6.000 Ω +(0.5% + 3)
60 KΩ 10 Ω 60.00 K Ω +(0.5% + 3)
1000V DC/AC rms
600 KΩ 100 Ω 600.0 K Ω +(0.5% + 3)
6 MΩ 1KΩ 6.000 M Ω +(1% + 5)
60 MΩ 10 K Ω 60.00 M Ω +(3% + 5)
Note : 1. Open Circuit Voltage on 600 -6M ranges is 0.62V DC approx. 2. Open Circuit Voltage on 60M range is 0.31V DC approx
Digital Multimeter - M63 62

Technical Details M63

Capacitance Range (Auto Ranging Only)


Range Resolution Max. Reading Accuracy Overload Protection

40 nF 0.01 nF 39.99 nF +(3.0% + 10)

400 nF 0.1 nF 399.9 nF +(3.0% + 10)

4 µF 1 nF 3.999 µF +(3.0% + 10)


1000V DC/AC rms
40 µF 10 nF 39.99 µF +(3.0% + 10)

400 µF 100 nF 399.0 µF +(3.0% + 10)

4000 µF 1 µF 3999 µF +(5.0% + 20)

Note : Setting time on 4000uF range is 40sec. approx.

< 2.85 V DC approx. < 1.0mA approx.

Continuity Test
Range Resolution

600.0Ω 0.1Ω Meter Beeps at <20Ω

Note : Open Circuit Voltage on continuity range is 0.64VDC approx.

Frequency Ranges (Auto Ranging Only)


Range Resolution Max. Reading Accuracy Overload Protection

10 Hz 0.001 Hz 9.999 Hz +(0.1% + 3)

100 Hz 0.01 Hz 99.99 Hz +(0.1% + 3)

1 KHz 0.1 HZ 999.9 Hz +(0.1% + 3)

10 KHz 1 Hz 9.999 KHz +(0.1% + 3) 1000V DC/AC rms

100 KHz 10 Hz 99.99 KHz +(0.1% + 3)

1000 KHz 100 Hz 999.9 KHz +(0.1% + 3)

10 MHz 1 KHz 9.999 MHz +(0.1% + 3)

Note : Setting time on 4000uF range is 40sec. approx.

Duty Cycle Measurement


Range Resolution Accuracy Overload Protection

0.1%-99.9% 0.1% +(0.5% + 3) 1000V DC/AC rms

Accessories
Standard

Standard Accessories Optional

Pair of Test leads, User Manual, Battery installed, Pair of test leads.

Fuses, Carrying Bag.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Multimeter - M65 63

Features
6,000 Count LCD Dual display with white backlit.
Auto ranging, terms AC Voltage & Current measurement.
Basic DCV Accuracy of 0.25%.
Highly Linear Readings.
Capacitance Range upto 60mF.
Resistance, Diode and Continuity Measurement Facility
Selectable Frequency & Duty Cycle Measurement.
60 position analogy bar graph for trend indication.
Select, Range, Hold, Rel, Lights, Max/Min
Functions Incorporated.
CE and IEC 61010-1 CAT III (1000V), IP 54 protection.
Robust, Rugged and Double Mould Casing.

M65
Digital Multimeter

CAT III IP Applications


1000V 54 Power Utility Industries
Electrical Contractor
The Motwane M65 Dual display Terms Digital Multimeter with high Telecommunication
accuracy, is specially designed in our Research Laboratory and
Railway
manufactured under stringent manufacturing processes for R&D and
Defence
Process industries. M65 has 6000 count LCD dual display and
measuring facilities like capacitance, resistance, diode and continuity
as well as comes with µ Amp. range & DCV accuracy of 0.25%. M65
includes the features you need to troubleshoot and repair electrical
and electronic systems.

M65 is a high performance multimeter complies with IEC 61010-1


safety standards and with CE, CAT III 1000 V safety rating, meeting
with IP54 protection. M65 is designed very robust and rugged with
double mould casing.
Digital Multimeter - M65 64

Technical Details M65

Accuracy
Accuracy is valid from 10% of range to 95% of the range.

Accuracy is specified as + % of reading + digits and is valid at 25 + 30C, < 55% RH Humidity.

It is recommended that calibration equipment used to verify the accuracy of the instrument should be 10 times more accurate.

Temp. Coefficient = (0.1% x Specified accuracy) per degree centigrade referred to 25°C. Accuracy is not valid if display shows ' LO BAT'.

General

Display 6,000 Count Dual, LCD display with white backlit.

Display Update Rate 2.8 times per second nominal.

Dimension 205 mm(L) X 94mm(W) X 36 mm(H) approx.

Weight 450g. approx.

Dual Display For AC Voltage with Frequency & Frequency with Duty Cycle simultaneously

Environmental
Operating Temperature 0°C to 50°C

Relative Humidity 80% RH @ 5°C to 31°C

50% RH @ 31°C to 40°C, Non condensing

Storage Temperature - 20°C to 60°C

Power
Power Supply 9V Battery Type 6F22 or equivalent

Power Consumption 8mA typical.

Low Battery Indication ‘ ' is displayed below 6.5V approx.

Auto Power OFF After 15 Min., Ideal sleep mode

consumption is 1.3mA approx. (Can be cancelled by pushing any except for

Hold & SELECT key before power on the meter).

Overload Protection
Fuse Protection for ‘µA’ & ‘mA’ input terminal 0.8 A/ 250V fast blow type ceramic fuse.

Fuse Protection for 10A input terminal 20A/ 500V fast blow type ceramic fuse

V/Ω/ / / /Hz (%) 440 V DC / AC rms

Safety

Directives for CE Certification LVD:2006/95/EC., EMC: 2004/104/EC

Measurement Category CAT III, (1000V) Reinforced Insulation

Relevant Standard Specification EN 61010-1:2010, EN61326-1:2006

IP Rating (Dust & Water Protection) IP 54

Accessories
Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.
Digital Multimeter - M65 65

Technical Details M65

Optional Accessories
Pair of test leads, Pair of small test leads

Range Resolution Max. Reading Accuracy Overload Protection

6V 1 mV 6.000 V +(0.25% + 3)

60V 10 mV 60.00 V +(0.25% + 3)


1050V DC/AC rms
600V 100 mV 600.0 V +(0.25% + 3)

1000V 1V 1000 V +(0.5% + 3)

Note: 1. Input Impedance 10M approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).

AC Voltage (50-500Hz) Trms


Range Resolution Max. Reading Accuracy Overload Protection

6V 1 mV 6.000 V +(1% + 5)

60V 10 mV 60.00 V +(1% + 5)


1050V DC/AC rms
600V 100 mV 600.0 V +(1% + 5)

1000V 1V 1000 V +(1.2% + 8)

Note : 1. Input impedance : 10 MΩ approx. shunted by 60pF approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).

3. Main display shows AC Voltage & sub display shows frequency applied.

DC Current Range
Range Resolution Max. Reading Accuracy Overload Protection

600µA/6000µA 0.1µA/1µA 600.0µA/6000µA +(1.2% + 5)


0.8A/ 250V DC/AC
fuse protection
60mA/600 mA 10µA/100µA 60.00mA/600.0 mA +(1.5% + 5)

20A/250V DC/AC fuse


10 A 10 mA 10.00 A +(1.5% + 8)
protection

AC Current Range (50Hz-500Hz) Trms


Range Resolution Max. Reading Accuracy Overload Protection

600µA/6000µA 0.1µA/1µA 600.0µA/6000µA +(1.5% + 5)


0.8A/ 250V DC/AC fuse
protection
60mA/600 mA 10µA/100µA 60.00mA/600.0 mA +(1.8% + 5)

20A/250V DC/AC fuse


10 A 10 mA 10.00 A +(2.0% + 8)
protection

Note: Main display shows AC Current and sub display shows frequency applied.

Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection

600 Ω 0.1 Ω 600.0 Ω +(0.5% + 3)

6 KΩ 1Ω 6.000 Ω +(0.5% + 3)

60 KΩ 10 Ω 60.00 KΩ +(0.5% + 3)
440V DC/AC rms
600 KΩ 100 Ω 600.0 KΩ +(0.5% + 3)

6 MΩ 1 KΩ 6.000 MΩ +(1% + 5)

60 MΩ 10 KΩ 60.00 MΩ +(3% + 10)

Note : 1. Open Circuit voltage on 600Ω range is -3.3V DC approx. 2. Open Circuit voltage on 6kΩ-6MΩ ranges is -1.10V DC approx.

3. Open Circuit Voltage on 60MΩ range is -600mV approx.


Digital Multimeter - M65 66

Technical Details M65

Capacitance Range (Auto Ranging Only)

Pair of test leads, Pair of small test leads

Range Resolution Max. Reading Accuracy Overload Protection

6 nF 0.001 nF 6.000 nF +(5.0% + 10)

60 nF 0.01 nF 60.00 nF +(3.0% + 10)

600 nF 0.1 nF 600.0 nF +(3.0% + 10)

6 µF 1 nF 6.000 µF +(3.0% + 10)


440V DC/AC rms
60 µF 10 nF 60.00 µF +(3.0% + 10)

600 µF 100 nF 600.0 µF +(5.0% + 10)

6 mF 1 µF 6.000 mF +(5.0% + 20)

60 mF 10 µF 60.00 mF +(5.0% + 30)

Note : 1. Settling time on 6mF and 60mF range is 40 sec. approx. 2. Press REL button at 6nF & 60nF ranges so that the offset count can be subtracted

from measurement. Now apply low value capacitance.

Diode Test
Range Resolution Open Circuit Voltage Test Current
6V 1mV <3.0 V DC approx. <2.0mA approx.

Continuity Test
Range Resolution
600.0Ω 0.1Ω Meter Beeps < 20Ω

Note: Open Circuit Voltage on continuity range is -3.3VDC approx.

Frequency Ranges (Auto Ranging Only)


Range Resolution Max. Reading Accuracy Overload Protection

60 Hz 0.01 Hz 60.00 Hz +(0.5% + 3)

600 Hz 0.1 Hz 600.0 Hz +(0.5% + 3)

6 KHz 1 HZ 6.000 KHz +(0.5% + 3)

60 KHz 10 Hz 60.00 KHz +(0.5% + 3) 1000V DC/AC rms

600 KHz 100 Hz 600.0 KHz +(0.5% + 3)

6 MHz 1 KHz 6.000 MHz +(0.5% + 3)

60 MHz 10 KHz 60.00 MHz +(0.5% + 3)

Note: 1. Main display shows frequency & sub display shows Duty Cycle. 2. If input frequency is less than 6.0Hz, display will show 0.00Hz.

Duty Cycle Measurement


Range Resolution Open Circuit Voltage Test Current
0.1%-98.9% 0.1% +(0.5% + 30) 440V DC/AC rms

Accuracy is specified at <20 VAC rms Sensitivity : 60Hz to 600 KHz > 3 Vrms, 6 MHz to 60MHz > 5Vrm, 1.00% -98.9% < 10KHz at 3 Vrms

Electromagnetic compatibility: In RF Field, overall accuracy is equal to 10% of reading +30 digits

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Clamp Meter - DCM49A 67

Features
True RMS reading for ACV & ACA
AC/DC Current measurements up to 1000A
Auto Ranging 3 ¾ digits (6000) LCD-Display Bargraph.
2 in 1 Clamp Meter + Digital Multimeter.
Overload protection for all ranges.
DCM-49A

Data Hold, Min/Max Hold


Water Resistant front panel, Fireproof heavy-duty
ABS Casing.
Current Sensor-Hall Effect Sensor
Over Range Indication: 'OL' is displayed.
Max Conductor size 60mm approx.
Power – 3*AAA 1.5V Alkaline Batteries
Double Colour backlight
Flashlight
Temperature Measurement
Non Contact Voltage detector (NCV)
with LED indication & Buzzer Sound.
Low Power Frequency Test.

DCM49A
Digital Clamp Meter

CAT II Applications
600V
Generation, Transmission & Distribution
Substation Process Industries.
Motwane's Digital Clamp Meter DCM 49A is highly precise, industrial
OEM's
grade, Trms, auto ranging clamp meters with 3 ¾ digit display. This Railway's
clamp meters can be used as multimeter with test leads for AC/DC Telecom Industries
Current measurements up to 1000A, AC/DC Voltage, Resistance,
Service Industries
Frequency, Capacitance, Duty Cycle and Diode, Continuity etc. This
clamp meters are provided with safety features like water resistant
front panel, fireproof heavy-duty ABS casing. It uses a Hall Effect
Sensor for measuring the current.
Digital Clamp Meter - DCM49A 68

Technical Details DCM 49A

General
Display 3 ¾ Digits LCD display, 6000 Count

Dimension 240 mm (H) X 85 mm (W) X 40 mm(L) (approx.)

Net weight 380 gm (approx.)

Power
Power Supply 3*AAA 1.5V Alkaline Batteries

Approx 15 min Auto Power Off, Low Battery Indication

Standard Accessories Pair of Test leads, User Manual, 3*AAA 1.5V Alkaline Batteries

AC Current (True rms for AC) DC Current


Range Resolution Accuracy Range Resolution Accuracy

60 A 0.01 A ±(2.5% reading+8) 60 A 0.01 A

600 A 0.1 A VFD : + (5.0% reading+10) 600 A 0.1 A ±(2.5% reading +8)
INRUSH : +(5.0% reading+10)
1000 A 1A 1000 A 1A

Max Current : 1000 A, True RMS Max Current : 1000A

Note : Press ZERO key to clear before measurement.

AC Voltage DC Voltage
Range Resolution Accuracy Range Resolution Accuracy

600mV 0.1 mV 600mV 0.1 mV


±(0.8% reading+5)
6V 0.001 V 6V 0.001 V
±(0.5% reading +5)
60 V 0.01 V 60 V 0.01 V

600 V 0.1 V 600 V 0.1V

750 V 1V ±(1.0% reading +5) 1000 V 1V ±(0.8% reading+5)

VFD 0.1 V ±(2.0% reading +5) Input Impedance : 10MΩ (Approx)

Input Impedance : 10MΩ (Approx) | Frequency Response : 45Hz - 1KHz Capacitance Range

Resistance Range Range Resolution Accuracy

Range Resolution Accuracy 10nF 0.001 nF

600 Ω 0.1 Ω 100nF 0.01 nF

6 KΩ 0.001 kΩ 1000nF 0.1 nF

60 KΩ 0.01 kΩ ±(1.0% reading 10μF 0.001 μF ±(4.0% reading +5)

600 KΩ 0.1 kΩ +5) 100μF 0.01 μF

6 MΩ 0.001 MΩ 1000mF 0.1 mF

60 MΩ 0.01 MΩ 10mF 0.001mF

100mF 0.01mF ±(5.0% reading +10)

Overload protection : 250 V.


Digital Clamp Meter - DCM49A 69

Technical Details DCM 49A

Duty Cycle
Range Accuracy

1% - 99% + 1% + 5dgt

Diode : Measures forward voltage drop

Continuity Check : Buzzer sound & LED indication.

Temperature (0C / 0F )
Range Accuracy Range Accuracy

-200C To 00C + 3% -40F to 320F +60F

00C To 4000C +1% or + 20 C 320F to 7520F +1% or +40F

4000C To 10000C + 2% 7520F to 18320F +2%

Frequency
Range Resolution Accuracy

10 HZ 0.001 Hz

100HZ 0.01 Hz

1 kHZ 0.1 KHz


±(1.0% reading +3)
10 kHZ 0.001 kHz

100 kHZ 0.01 kHz

1 MHZ 0.1 kHz

10 MHZ 0.001 MHz ±(3.0% reading +3)

Overload Protection : 250 V

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Clamp Meter - DCM30A 70

Features
AC Current measurements up to 1000A,
Auto Ranging 3 ¾ digits (6000) LCD-Display.
True RMS reading for ACV & ACA
2 in 1 Clamp Meter + Digital Multimeter.
Overload protection for all ranges.
Data Hold, Min/Max Hold
Water Resistant front panel, Fireproof heavy-duty
ABS Casing.
Current Sensor-Hall Effect Sensor
Over Range Indication: 'OL' is displayed.
Max Conductor size 60mm approx.
3*AAA Alkaline Batteries
Double Colour backlight
Flashlight
Temperature measurement
Non Contact Voltage detector (NCV)
with LED indication & Buzzer Sound.

DCM 30A
Digital Clamp Meter

Motwane's Digital Clamp Meter DCM 30A is highly precise, industrial Applications
grade, Trms, auto ranging clamp meters with 3 ¾ digit display. This
clamp meters can be used as multimeter with test leads for AC Generation, Transmission & Distribution
Current measurements up to 1000 A, AC/DC Voltage, Resistance, Substation Process Industries.
Frequency, Capacitance, Duty Cycle and Diode, Continuity etc. This OEM's
clamp meters are provided with safety features like water resistant Railway's
front panel, fireproof heavy-duty ABS casing. It uses a Hall Effect Telecom Industries
Sensor for measuring the current.
Service Industries
Digital Clamp Meter - DCM30A 71

Technical Details DCM 30A

General
Display 3 ¾ Digits LCD display, 6000 Count

Dimension 240 mm (H) X 85 mm (W) X 40 mm(L) (approx.)

Net weight 380 gm (approx.)

Power
Power Supply 3*AAA 1.5V Alkaline Batteries

15 Min Auto Power OFF, Low Battery Indication

Standard Accessories Pair of Test leads, User Manual,3* AAA Batteries 1.5V

AC Current (True rms for AC)


Range Resolution Accuracy VFD Inrush

60 A 0.01 A ±(5% reading + 10) ±(5% reading + 10)

600 A 0.1 A ±(2.5% reading+8)

1000 A 1A

Maximum Current : 1000 A

AC Voltage DC Voltage
Range Resolution Accuracy Range Resolution Accuracy

6V 0.1 mV 600 mV 0.1 mV

60 V 0.001 V ±(0.8% reading+5) 6V 0.001 V ±(0.5% reading + 5)

600 V 0.1 V 60 V 0.01 V

750 V 1V ±(1.0% reading+5) 600 V 0.1 V

VFD (750) 0.01 V + (2.0% reading+5) 1000 V 1V ±(0.8% reading + 5)

Input Impedance : 10MΩ (Approx) | Frequency Response : 45Hz - 1KHz Input Impedance : 10MΩ (Approx)

Resistance Range Capacitance Range


Range Resolution Accuracy Range Resolution Accuracy

600 Ω 0.1 Ω 10nF 0.001 nF

6 KΩ 0.001 kΩ 100nF 0.01 nF

60 KΩ 0.01 kΩ 1000nF 0.1 nF


±(1.0% reading+5)
600 KΩ 0.1 kΩ 10μF 0.001 µF ±(4.0% reading+5)

6 MΩ 0.001MΩ 100μF 0.01 µF

60 MΩ 0.01MΩ 1000μF 0.1 µF

10mF 0.001 mF

100mF 0.01 mF ±(5.0% reading+10)


Digital Clamp Meter - DCM30A 72

Technical Details DCM 30A

Duty Cycle
Range Accuracy

1% - 99% + 3% + 3dgt

Diode : Measures forward voltage drop

Continuity Check : Buzzer sound & LED indication.

Temperature (0C / 0F )
Range Accuracy Range Accuracy

-200C To 00C + 30C -4F to 320F + 60 F

00C To 4000C + 1% + 20C 32F to 7520F + 1% or + 40 F

4000C To 10000C + 2% 752F to 18320F + 2%

Frequency
Range Resolution Accuracy

10 HZ 0.001Hz

100HZ 0.01Hz

1 KHZ 0.1Hz

10 KHZ 0.001kHz ±(1.0% reading+3)

100 KHZ 0.01kHz

1 MHZ 0.1kHz

10 MHZ 0.001MHz ±(3% reading+3)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Clamp Meter - DCM 39A/9930A 73

Features
Auto Ranging 3 ¾ digits (3999) LCD-Display.
True RMS reading for ACV & ACA
2 in 1 Clamp Meter + Digital Multimeter.
Overload protection for all ranges.
Data Hold, Relative Key Facility
Water Resistant front panel, Fireproof heavy-duty
ABS Casing.
Current Sensor-Hall Effect Sensor
Over Range Indication: 'OL' is displayed.
Max Conductor size 60mm approx.
Power – one 9V battery type (6F22)

DCM 39A/9930A
Digital Clamp Meter

Motwane's Digital Clamp Meter DCM 39A & DCM 9930A are highly Applications
precise, industrial grade, Trms, auto ranging clamp meters with 3 ¾
digit display. Both these clamp meters can be used as multimeter Generation, Transmission & Distribution
with test leads for AC/DC Current measurements up to 400 mA, Substation Process Industries.
AC/DC Voltage, Resistance, Frequency, Capacitance, Duty Cycle and OEM's
Diode, Continuity etc. These clamp meters are provided with safety Railway's
features like water resistant front panel, fireproof heavy-duty ABS Telecom Industries
casing. It uses a Hall Effect Sensor for measuring the current. The
Service Industries
model DCM 39A measures AC/DC currents up to 1000A. The model
DCM 9930A measures AC/DC currents up to 2000A.
Digital Clamp Meter - DCM 39A/9930A 74

Technical Details DCM 39A/9930A

General
Display 15 mm (0.6") LCD, 4 digits max indication 5000

Dimension 38 mm(L) X 73 mm (W) X 255 mm (H) (approx.)

Net weight 515 gm with battery (approx.)

Power

Power Supply 9V Battery Type 6F22

Standard Accessories
Pair of Test leads, User Manual, One 9V Battery installed

AC/DC Current (True rms for AC)- DCM39A / DCM9930A


Range Resolution Input Accuracy

400 µA 0.1 µA + 1.2% + 5dgt

4000 µA 1 µA + 1.2% + 5dgt


Direct Input (by using leads)
40 mA 0.01 mA + 1.2% + 5dgt

400 mA 1 mA + 1.2% + 5dgt

400 A 0.1 A + 2% + 5dgt


Indirect Input (by using clamp)
1000 A 1A + 2% + 8dgt

2000 A (DCM 9930A ) 1A + 2% + 8dgt

Overload Protection : AC/DC 500mA(Fuse) | AC/DC 1000A/1000V | Frequency Response : 45Hz - 1KHz

Common Technical Specification for DCM39A / DCM9930A


DC Voltage
Range Resolution Accuracy Overload protection

400mV 0.1 mV + 0.5% + 2dgt

4V 0.001 V + 1% + 2dgt
1000V DC OR 1000V
40V 0.01 V + 1% + 2dgt
AC rms (Sine wave)
400V 0.1 V + 1% + 2dgt

1000V 1V + 1.2% + 5dgt

Input Impedance : 10MΩ (Approx)

AC Voltage
Range Resolution Accuracy Overload protection

4V 0.001 V + 1.2% + 5dgt

40V 0.01 V + 1.2% + 5dgt 1000V DC OR 1000V


AC rms (Sine wave)
400V 0.1 V + 1.2% + 5dgt

1000V 1V + 1.2% + 5dgt

Input Impedance : 10MΩ (Approx) | Frequency Response : 45Hz - 1KHz


Digital Clamp Meter - DCM 39A/9930A 75

Technical Details DCM 39A/9930A

Resistance Range
Range Resolution Input Accuracy

400 Ω 0.1 Ω + 1% + 5dgt

4 KΩ 1Ω + 1% + 5dgt

40 KΩ 10 Ω + 1% + 5dgt
400V DC/AC RMS (Sine wave)
400 KΩ 100 Ω + 1% + 5dgt

4MΩ 1 KΩ + 2% + 2dgt

40 M 10 K + 3.5% + 5dgt

Capacitance Range
Range Resolution Input Accuracy

50Hz 0.01HZ + 1% + 5dgt 1000V AC/DC

500Hz 0.1Hz + 1% + 5dgt

5KHz 1Hz + 1% + 5dgt 1000V AC/DC

50KHz 0.01 kHz + 1% + 5dgt

100KHz 0.1 KHz + 1% + 5dgt

Amplitude : < 5V

Duty Cycle
Range Resolution Accuracy Overload protection
1% - 99% 0.1% + 1% + 5dgt 1000 V AC/DC

Diode : Measures forward voltage drop

Continuity Check : Buzzer sound if Resistance < 10

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
76
Telemetrics Is Now Part of Motwane Group

Underground Cable Fault Locator Solution


in our Product Basket.
78

Different Types of Cable Network

LT NETWORK EQUIPMENT
( Low Voltage Network 1.1KV )

Cable Fault Detection Steps Equipments


Diagnosis Multimeter & Insulation Tester
Pre-locator Cable Fault Pre-locator TFL 8
Cable Route Tracer Cable Route Tracer CRT 10D
Surge Tester System LV Surge tester SWT 4 / SWT 6 &
( Thumper + Receiver ) Surge Wave Receiver SLE 90

High Voltage DC Test HV DC Test Set HVG 40


( Optional )

MV NETWORK EQUIPMENT
( Medium Voltage Network 11KV )
Cable Fault Detection Steps Equipments
Diagnosis Multimeter & Insulation Tester
Pre-locator Cable Fault Pre-locator TFL 8
Cable Route Tracer Cable Route Tracer CRT 10D
Surge Tester System HV Surge tester SWT 16D &
( Thumper + Receiver ) Surge Wave Receiver SLE 90

High Voltage DC Test HV DC Test Set HVG 40


( Optional )

HT NETWORK EQUIPMENT
( High Voltage Network 33KV )
Cable Fault Detection Steps Equipments
Diagnosis Multimeter & Insulation Tester
Pre-locator Cable Fault Pre-locator TFL 8 / TFL 9
Cable Route Tracer Cable Route Tracer CRT 10D
Surge Tester System HV Surge tester SWT 32 / SWT 32D &
( Thumper + Receiver ) Surge Wave Receiver SLE 90

High Voltage DC Test HV DC Test Set HVG 50


( Optional ) SIM / ARC Filter
79

Power Sector LV Surge Testers

Low Voltage Surge Tester


Model : SWT 4
LT Network up to 1.1kV
( Use with Surge Wave Receiver ) Features :
Pinpoint location of cable fault in LT cables by
acoustic method.

Voltage ranges 2kV & 4kV selectable

500J Energy ( optional 1000J ) at easy pinpoint


of fault.

Pre-Location of fault distance using ICM method


coupling with suitable Pre-locator.

Continous operation for extended period in case


of difficult faults.

Fully protected operation with safely interlocks.

Auto discharge facility.

Rugged construction.

Low Voltage Surge Tester


Features :
Model : SWT 6
Pinpoint location of cable fault in LT/HT cables by
LT Network up to 1.1kV acoustic method.
(Use with Surge Wave Receiver)
Voltage ranges 3kV & 6kV.

750J Energy (optional 1000J) at each range for


easy pin-pointing of fault.

Pre-location of fault distance using ICM method


coupling with suitable Pre-locator.

Pre-location of fault distance using SIM method


coupling with ARC reflection filter and suitable
Pre-locator.

Continuous operation for extended period in case


of difficult faults.

Fully protected operation with safely interlocks.

Rugged construction.
80

Power Sector HV Surge Testers

High voltage surge tester

Model : SWT 16 / SWT 16D / SWT 16CPT


Medium Network up to 11kV
( Use with Surge Wave Receiver )
Features :
Pinpoint location of cable fault in
LT / HT cables by acoustic method.

Output surge voltage 4kV ,8kV & 16kV

Surge energy 500J ( optional 1000J / 2000J )


full energy at each range for easy Pin-pointing
of fault.

Pre-location of fault distance


using ICM method coupling with suitable
Pre-locator.

Pre-location of fault distance using SIM


method coupling with Arc reflection filter
and suitable Pre-locator.

Continous operation for extended


period in case of difficult faults.

Fully protected operation with


safely interlocks.
Auto discharge facility.
Rugged construction.

High voltage surge tester


Features :
Model : SWT 32 / SWT 32D /SWT 32CPT
Pinpoint location of cable fault in LT / HT cables
by acoustic method.
HT Network up to 33kV
( Use with Surge Wave Receiver ) Output surge voltage 8kV ,16kV & 32kV
Surge energy 1000J ( optional 2000J /3000J )

full energy at each range for easy Pin-pointing


of fault.

Pre-location of fault distance using ICM method


coupling with suitable Pre-locator.

Pre-location of fault distance using SIM method


coupling with Arc reflection filter and suitable
Pre-locator.

Continuous operation for extended period in case


of difficult faults.

Fully protected operation with safely interlocks.

Auto discharge facility.

Rugged construction.
81

Power Sector Surge Receiver

Surge Wave Receiver

Model : SLE 90
Features :
For pin-pointing of cable faults by acoustics and
magnetic method.

Guides the operator to be on cable route while


pin-pointing.

Dual channel LCD display denoting the signal


strength of magnetic and acoustic signals.

Separate sensitivity and volume/level


controls for magnetic and acoustic channels.

No external noise under mute operation.

Battery check facility.

Time lapse display ( optional )

Surge Wave Receiver Features :


Model : SLE 200Z Perfect function, suitable for pin-pointing all kinds
of cable faults and detect path.

High accuracy.

Synchronous sensing of acoustic and magnetic


signals of the fault with high ability to
anti-interference.

Waveforms displayed on large LCD.

With the assistance of the earphone, direct and


easy to identify the fault.

High Acoustic & Magnetic field sensitivity.

Comparison of last and the new measurement.

Time lapse display.

Stealth fault pin-pointing by step voltage method.

Low batt indication.

Mute operation.
82

Power Sector High Voltage Combo Surge Test Sets

High Voltage Surge Tester

Model : SWT 16CPT


( Use with Surge Wave Receiver )
Features :
Two working mode Surge and DC high voltage
( High Pot ) test.

Pin-point location of cable faults in Low, Medium


and high voltage cables by acoustic method.

Perform Surge and DC high voltage


test up to 16 kV.

Output voltage selectable in three ranges


4kV,8kV,16kV.

High energy of 1000 Joules. ( optional 2000 J )

Full energy delivering capacity at each


select range in SWT mode.
Fully protected operation with safety interlocks.

Cable fault resistance burning facility.

Emergency OFF facility.

High Voltage Surge Tester


Features :
Model : SWT 32DPT-S
Two working mode Surge and DC high voltage
(Use with Surge Wave Receiver) ( High Pot ) test.

Pin-point location of cable faults in Low, Medium


and high voltage cables by acoustic method.

Perform Surge and DC high voltage test up to 32 kV.

Output voltage selectable in three ranges 8kV, 16kV,


32kV.

High energy of 2000 Joules. ( optional 1000 J ).

Full energy delivering capacity at each select range


in SWT mode.

Fully protected operation with safety interlocks.

Cable fault resistance burning facility.

In built ARC Module/Filter.

Emergency OFF facility.


83

Power Sector High Voltage Test Sets

High Voltage DC Test Set Reliable and cost-effective


equipment for high pressure
Model : HVG 40 testing of cables

(Other models are available on request)


Features :
Easy to perform HIPOT test.

Only DC or AC/DC combined units.

Continuously variable voltage up to 40kV, 20mA.

Open or close discharge unit option.

Selectable current ranges.

Input & output over current tripping protection.

Built in auto discharge in case of mains power


failure or equipment switch off.

Emergency OFF facility.

Timer provision to switch of equipment


automatically after the preset period.

High voltage DC test set Features :


Model : HVG 70 Easy to perform HIPOT test.

Only DC or AC/DC combined units.

Continuously variable voltage up to 70kV, 10mA.

Open or close discharge unit option.

Selectable current ranges.

Input & output over current tripping protection.

Built in auto discharge in case of mains power


failure or equipment switch off.

Emergency OFF facility.

Timer provision to switch of equipment


automatically after the preset period.

Additional discharge rod provided.

Rugged construction.
84

Power Sector Cable Route Tracer

Cable Route Tracer Reliable and cost-effective


equipment for Cable route
Model : CRT 8 tracing

Other products CRT50 , CRT200 , CRT500


as per customer request. Features :
Route tracing of buried cables up to 10 km length.

Depth measurement of buried cable more than 5m.

Output power 1, 2 , 4 & 8 watt selectable.

Output Frequency 480Hz, 1450Hz 9820Hz


selectable.

Identification of wanted cable from bunch of cables


in telecom cables.

Ground survey for underground metallic utilities.

Route tracing of live loaded cables.

Inductive coupling in a particular cable using


transmitter tongs.

Cable Route Tracer Features :


Model : CRT 10 Route tracing of buried cables up to 10 km length.

Depth measurement of buried cable more than 5m.

Output power 1, 2 , 5 & 10 watt selectable.

Output Frequency 480Hz, 1450Hz 9820Hz


selectable.

Identification of wanted cable from 9820Hz


selectable.

Ground survey for underground metallic utilities.

Route tracing of live loaded cables.

Inductive coupling in a particular metallic utilities.

Pin-point contact nature fault in power cables.


85

Power Sector Associated Equipments

Shealth Fault Tester Reliable and cost-effective


equipment for Shealth / earth
Model : SFL 12 fault location

SFL1 ( 6 kV ) / SFL25 ( 25kV ) also available


Features :
Suitable equipment for to test, condition, Pre-locate
and Pin-point of stealth fault.

Pre-location of stealth fault using Micro controller


based operation.

Insulating testing up to 12kV DC

Conditioning of fault by 1200 VA power in 3


selectable ranges.

Auto discharge facility.

Stealth fault pre-location with high precision


measuring bridge method.

Maximum 400mA current to gives better result.

Rugged construction.

Reliable and cost-effective


Cable Burn Down Instrument equipment for Cable Burn down

Model : CBD 7
Features :
Burn down high resistance / unstable faults to
alter fault condition.

6 selectable range with AC and DC operation.

High energy output, suitable for drying long wet


cables under controlled condition.

Interlock protection for safe operation.

Burn down voltage continuously variable from


0-100%

Auto discharge facility.

Input overcurrent protection.

Rugged construction.
86

Power Sector Cable Fault Pre-Locators

Cable Fault Pre-locator Reliable and cost-effective


equipment for Pre-location
Model : TFL 5 of cable fault

Features :
TDR mode

Measuring range 8 km ( optional 16 km )

Open & short fault of all types of metallic cable.

Open & short fault of power cable upto 1.1 kV.

Auto testing mode.

Memory storage through USB.

Cable Fault Pre-locator Features :


Model : TFL 8 Two work modes selectable, TDR and ICM

Interactive menu-guidance operation with manual


and touch screen operation.

Measuring range up to 100 km.

Internal storage of waveforms.

Communication with computer through USB port.

Memory save through USB device for printing of


store graph.

Big 7 color LED screen , 160 viewing angle.


87

Power Sector Cable Fault Pre-Locators

Reliable and cost-effective


Cable Fault Pre-locator equipment for Pre-location
of cable fault
Model : TFL 9

Features :
Three work modes selectable, TDR, ICM & SIM

Automatic fault in TDR modes.

Measuring range up to 64km.

Comparison between healthy with faulty cable.

Pre-location of fault distance using ICM method


coupling with sutable surge Tester.

Pre-location of fault distance using SIM method


coupling with suitable surge Tester & Arc reflection
filter.

PC Compatibility.

Internal memories stores up to 100 result.

Printer facility through via USB.

Cable Fault Pre-locator


Features :
Model : TDR 4000
Cable Fault Pre-locator TDR 4000

HT Network

Most advanced pre-locator in Telemetrics Portfolio

All modes available – TDR, ICE/ICM,


ARM ( SIM / MIM ) , Decay

Measuring Range – 120 Km.

Touch-sensitive display.

10 inch touch pad operation.

3 phase mesurement (optional).


88

Power Sector Combined Systems

Cable Fault Locating System Reliable and cost-effective


equipment for Pre-location,
Model : Compac 20 Pin-point & Cable pressure testing

Customized mode is also available


Features :
Pin-point location of cable fault in LT / HT cables
by acoustic method.

Output surge voltage 4, 8, 16kV.


Surge energy 1000J ( optional 2000J ) full energy
at each range for easy pin-pointing of fault.

DC testing up tp 20kV, 10mA & Burning 60mA.


Shealth fault up to 5kV DC.
Fully menu guided.
Connect with Touchscreen & LCD
Fully protected operation with safety interlocks.
Five mode for Pre-location TDR, ICM, SIM, MIM &
Decay

Measuring range : 64km.


Auto discharge facility.
Cable drum HV, Mains, Earthing Aux. Earth & TDR
15mtr. each.

Rugged construction.

Cable Fault Locating System


Features :
Model : Compac 32 Pin-point location of cable fault in LT / HT cables
by acoustic method.

Output surge voltage 8, 16, 32kV.

Surge energy 1000J ( optional 2000J ) full energy


at each range for easy pin-pointing of fault.

DC testing up to 32kV, 10mA & Burning 60mA.

Shealth fault up to 10kV DC.

Fully menu guided.

Connect with Touchscreen & LCD

Fully protected operation with safety interlocks.

Five mode for Pre-location TDR, ICM, SIM, MIM &


Decay

Measuring range : 64km.

Auto discharge facility.

Cable drum HV, Mains, Earthing Aux. Earth & TDR


15mtr. Each.

Rugged construction.
89

Power Sector Trolley Mounted Systems

Trolley Mounted LT Cable Fault Locating System

Model : LOCOMP
LT Network Up to 1.1 kv
Features :
Compact system for Pre-location and Pin-pointing
the faults in LT / HT cables.

Consisting of :

Cable fault Pre-locator TFL8


HV surge Tester - SWT 6
surge wave receiver - SLE 90
HV, Mains & Earting cable drum of 10mtr.
cable length. ( optional ) Insulation Tester
for IR measurement.

Pre-location of fault distance 100km.

Output surge voltage 3kV & 6kV.

Surge energy 750J.

Comprehensive safety interlocks.

Mounted on 2 rubber & 2 ms swivel wheel trolley


for excellent mobility, Rugged construction for
ease of transportation.

Trolley Mounted HT Cable Fault Locating System Features :


Model : HICOMP 16 Compact system for Pre-location and Pin-pointing
the faults in LT / HT cables.
Medium Network uo to 11kV
Consisting of :
Cable fault Pre-locator TFL8
HV surge Tester - SWT 16D
surge wave receiver - SLE 90
HV, Mains & Earting cable drum of
10mtr. cable length. ( optional ) Insulation
Tester for IR measurement.

Pre-location of fault distance 100km.

Output surge voltage 4, 8,16kV.

Surge energy 1000J ( optional 2000J ).

Comprehensive safety interlocks.

Mounted on 2 rubber & 2 ms swivel wheel trolley


for excellent mobility, Rugged construction for
ease of transportation.
90

Power Sector Other Products

Reliable and cost-effective


Cable Identification System
equipment for cable identification
system of power cables
Model : CI 60S
Features :
Identification of wanted power cable from bunch
of cables.

Operation on battery / mains supply

Suitable for single or multi-core armoured or


unarmoured cables.

High impulse current up to 60Amp for reliable result.

6 steps for sensitivity control.

Available of special tongs 120mm & 150mm opening.

Soft Discharge Rod Reliable and cost-effective


equipment for discharging cable
or insulators
Model : SDR11, SDR35, SDR70
& SDR100KV
Other model available
Hard Discharge Rod Model : HDR 11kV to 100kV
Features :
Maximum discharge capacitance up to 6uF to 10uF.

In-built damp discharge current limiting resistance.

Robust fiberglass housing.

Heavy duty Brass tip.

Flexible copper wire with heavy duty ‘C’ Clamp.

Supplied with cushioned soft carrying case.


91

Power Sector Van / Trailer Systems

Features :
92

Power Sector Van / Trailer Systems

Features :
DC testing upto 80kV – 25mA

Cable Burning 200mA @ 40kV.

Surge Voltage 4, 8, 16 & 32kV.

Surge Energy up to 4kV – 1000J / 8-16-32kV - 2000


Joules / 3000J option also available

Surge ranges / timer / Hipot voltage/ Burn voltage &


current settings, control & display on 10.1 inch
touchscreen or blue tooth mouse control color display

Pre location model TDR , ICM . SIM/MIM & DECAY

Pre-location range up to 120km. Display 10.4”,


800x600 TFT, Touch-sensitive.

Sheath fault test voltage up to 10kV

Fault pinpointer, cable identification system.


Cable route tracer.

Easy user friendly interface.

Highest safety level and multi step self fault protection


with error code display.

Flexible auxiliary equipment integration.

Cable Drums - 50mtr.

Tempo Traveller 3350 AC BS6 / Equivalent


van with internal modification

3kVA silent generator ( optional )

Standalone VLF and partial discharge


measurement facility (optional)

GPS mapping and remote operation through APP


(optional)

Customisation shall be possible


Notes :
Contact Details Scan the QR code to visit
Motwane’s new website

The MOTWANE Manufacturing


Company Private Limited

Gyan Baug, Nashik Road,


422101 Maharashtra, India

www.motwane.com
National : 03/01/2023

Toll-free number:
1800 233 7766

https://www.linkedin.com/company/motwanemanufacturing