You are on page 1of 120

2021

PRODUCT CATALOGUE

Electrical Test & Measurement


Instruments

The Motwane Manufacturing Company Private Limited | Nashik, India


CONNECT
TEST
ANALYSE
Table of Contents 1

Table of Contents

Sr.No. Contents Page No.

1. Digital Insulation Testers


Diagnostic Insulation Tester : 10K PI 8
Diagnostic Insulation Tester : 5K PI 10
5KV Digital Insulation Resistance with Polarization Index : IT-51 13
5KV Battery Operated Digital Insulation Resistance : IT-250G 15
1KV Digital Multimeter Insulation Tester : MIRT-61 18
1KV Battery Operated Digital Insulation Resistance : i-12 22

2. Transformer Testing Instruments


Transformer Winding Resistance Meter : XWRM-10 24
Transformer Winding Resistance Meter : XWRM-10A 26
Winding Resistance Meter : XWRM-25A 29
Transformer Turns Ratio Meter : XTRM-3 32
Oil Tan Delta & Resistivity Tester : MOTR 35
Automatic Oil Insulating Test Set : OTS 60A/80A/100A 38
Digital Oil Insulation Test Set : OTS 60DS/80DS/100DS 41
Analog Oil Insulation Test Set : ANALOG OTS 60/80/100 44
Voltage Calibrator For Oil Test Set : VC 100 46

3. Contact Resistance/Low Resistance Meter


Contact Resistance Meter : PCRM-200S 47
Contact Resistance Meter : PCRM-100S 50
Contact Resistance Meter : PCRM-100SM 53
Contact Resistance Meter : CRM100A 55
10 (AMPS CURRENT) : LR-2065S 57
Micro Ohm Meter : LR-2045S 60

4. Protection Testing
Circuit Breaker Timer Kit : MCBT-P 63
Circuit Breaker Operational Analyser : MCBO-A 66
Circuit Breaker Operational Analyzer - MCBOA Plus 73
Portable Dynamic Contact Resistance Meter : MDCR-M 76
DC Ground Fault Locator : MGFL 78
Leakage Current Monitoring : MLCM 81
Leakage Current Monitor : MLCM-B2 83
AC-DC Hi Pot Test Set : HVT Series 85
Relay Test Set : MOT - RTS 87
Primary Current Injection Kit : PIK Series 90

5. High Voltage Detector (33KV/132KV/220KV/400KV) 93

6. Digital Earth Tester


Digital Earth Tester : DET 20 95
Digital Clamp on Earth Resistance Tester : DECT 3 97
Digital Clamp on Earth Resistance Tester : DECT 2 99
7. Digital Multimeter
Digital Multimeter Industrial Graded : M63 102
Digital Multimeter : M65 106
8. Digital Clamp Meter
Digital Clamp Meter : DCM49A 110
Digital Clamp Meter : DCM 39A/9930A 113
Company Profile 2

Over Hundred Years of Progress

Motwane is an Indian engineering company with an To be collaborative, curious, and authentic are the core
impressive legacy and a strong focus on R&D and IoT values that have been part of Motwane’s success story from
capabilities Its products, ranging from power plants to the start.
plug points, and surpass existing quality standards, are
synonymous with robust, reliable, and long-last What Make Motwane Unique ?
performance.
Pioneers
As a result, the Motwane brand has earned the trust of
clients over the last 100 years with its innovative, energy- We are innovators in the design and manufacture of high-
efficient, and user-friendly solutions. performance, high-precision electrical Test & Measurement
equipment.

Innovation
We create innovative IoT technologies and digital offerings
that are designed to boost productivity, efficiency, energy
saving, proactive decision making, and help our customers
to take a step towards a green, more sustainable future

R&D Facilities
We work in world-class R&D facilities in which all of
Motwane’s products and solutions are indigenously
designed by over 40 technologists. Maybe not world class?

Global Distribution Network


We have built a strong global distribution network with a
presence in more than 50+ countries, catering to the needs
Motwane’s spirit of innovation has not only transformed an of users across segments, such as EPC, Power, Railways,
entire industry, but also quietly keeps cities running and Certification Labs, Defence, Oil & Gas, Steel & Metal,
street lights shining while you sleep. Automobiles, Process Industries, and the MSME sector, in
addition to contractors and OEMs
The company’s global growth, and further innovative
ventures as part of its green initiatives are guided under Production
the aegis of Motwane’s forward-thinking leadership, who We offer a diverse product line, encompassing low voltage
are committed to creating opportunity and always going solutions for general industrial applications, specialized
the extra mile for our clients, partners, and employees, so products for high voltage applications, IoT-based intelligent
together we can engineer a better future for the world. street lighting solutions, advanced security solutions, and
digitized testing software

Our Journey

Launch of Motwane Launch of HV Launch of Motwane Acquisition of


Foundation Manufacturing in Nashik Product Basket Security Systems Telemetrics

1909 1960 2008 2017 2021

1926 1967 2016 2020


Renamed as Chicago Manufacture of the Launch of Motwane Launch of
Telephone & Radio Co. 1st MultiMeter, 8x Mark III Lighting MOT-WARE
Our Legacy 3

A Legacy of Innovation
We are committed to taking the
Motwane was one of the earliest manufacturing
passion Mr. Nanik Motwane showed
companies during the time of the British Raj.
in the early days of the company
Inaugurated in 1909, Motwane started out
from a patriotic past into the
pioneering the mass medium of radio, and from
digital future.
then on, the firm’s history has been tightly
interwoven with the history of India. In 1929, 18
years before Indian Independence in 1947, the The bottom line of hope
Freedom Movement led by Mahatma Gandhi was
Motwane strives to continue to leave a mark on Indian
well under way. Motwane’s Managing Director at history – within the country’s boundaries and abroad - and
the time, Nanik Motwane, recounts: to help shape the next generation of engineers to
successfully tackle the challenges of tomorrow. Driven by
“ I saw Gandhi-ji going from insatiable curiosity, and the will to never give up, we work
platform to platform to
hard to create digital and physical spaces where we can
address meetings at one
turn dreams into realities. Our hope lies in being able to
and the same place, to
enable his weak voice to be predict the future by learning from the past, live in
heard by large numbers. It harmony with nature and each other, and to use the
was then that I felt that I advancements of technology and our capacity as
must find some means to
‘machine whisperers’ to create a safer, more equal, and
amplify his voice. ”
creative world.
Mr. Nanik G. Motwane

His solution: a loudspeaker that effortlessly Prominent Testimonial


carried Gandhi’s and other freedom fighter’s “Sjt. Nainik G. Motwane has been serving the Indian
voices to the masses. One can only estimate how National Congress since 1929 with his loudspeakers. Those
big the impact of Motwane’s patriotic impulse was who have witnessed the huge demonstration of the
Bombay Congress must have vivid recollections of his
on India’s Independence movement. Mr. Nanik’s
admirable arrangements. The Reception Committee will
immediate reaction to solve a problem at hand
not be able to find better arrangements in this line.”
with the help of technology, creating a positive
impact for the greater good, has been the Sardar Vallabhbhai Patel – First Deputy Prime Minister
cornerstone of Motwane’s ethos as a company. of India
Division Q

The last 100 years has seen the company rise to a Industrial & Commercial
significant position across the electrical sector in India and Embracing the global shift towards intelligent, cloud-
abroad, pioneering electrical test & measurement based technologies, Motwane offers efficient solutions
equipment that set market benchmarks for a wide range of that help its clients to take the necessary leap towards a
clients. Motwane’s long-standing commitment to greener future.
innovating products that anticipate future needs has led to
further diversification, and the creation of MOT-WARE, an
IoT-based test data software, AI engines for data
vis u al i s at io n , s m ar t lig ht i n g , a n d o t he r e n e rgy
management solutions.

Electrical
Working closely with our customers enables Motwane to
successfully innovate, design, and engineer future-ready
solutions. For the electrical sector, we have engineered a
variety of high precision test & measurement equipment
that have been industry standard for decades. Our
electrical business is organised into the following two
verticals.
The world is transitioning through a massively changed
Power & Grid technological landscape. There is a global shift towards cloud-
For decades, Motwane’s Test & Measurement product based IoT technologies that have become a part of day-to-day
Operations in intelligent factories, industry 4.0, green
range has helped clients to maintain efficiencies, ensure
buildings, and net-zero, with the remote monitoring of capital
safety, and increase profitability.
equipment through ‘digital twins’.

Responding to this need, Motwane has designed a range of


products that boost productivity, improve efficiency, and save
energy.

Motwane Security Systems


Motwane Security Systems, another business division of
Motwane, offers a range of holistic solutions for a spectrum of
access and entrance control needs.

Power & Grid is an interconnected network that generates,


transmits, and distributes electricity to the consumer.
Without these complex power systems, no cities, Backed by aesthetics engineering, our products are designed
industries, residential complexes, offices, and public to add sophistication to the environment, and peace of mind
infrastructure would be able to function. Recognizing the to users. The company’s strong R&D lab and manufacturing
need for resistant, reliable, and high-quality equipment, facilities ensure that each product delivers on our promise of
Motwane has taken large strides by offering real-time quality, precision and innovation.
monitoring, combined with accurate testing capabilities of
power systems.

We have acquired Telemetrics, an established market Visit our website


leader in highly specialised underground cable fault www.motwane.com
locating equipment, to serve global customers in the for more information
power and grid sector.
Global Presence 5

“ Presence in over 45 Countries Worldwide ”

From India to the world


The company's international expansion over the last
decade has contributed to Motwane's growth, and, as a Motwane is Committed to offering
result, strengthened its positioning as an internationally lone-term sustainable growth
acknowledged brand. Their robust, innovative, and
constantly evolving product portfolio enables Motwane
to expand their reach into new markets.
Motwane complies with the following global
Constant R&D is one of the driving fundamentals at the
standards and certifications
company. Our diverse global presence empowers
Motwane to build scale efficiency, and through our variety
of project sizes, teams, and locations, we are able to
leverage the world for new knowledge and expertise,
incorporating it in our R&D facilities.

ISO 9001 (2015) QMS (Quality Management


International Clients System)
ISO 9001:2015 is internationally recognised as the world’s
leading quality management standard, ensuring a framework
for continuous improvement of the same within an
organisation.

CE Certification
CE marking is an administrative marking that indicates
conformity with health, safety, and environmental protection
standards for products sold within the European Economic
Area (EEA).
Product & Services 6

Test & Measurement

For more than a century, Motwane has set a benchmark


for test & measurement solutions and pioneered the
development of high-precision equipment across
segments.

Telemetrics Cable Fault Locator


Telemetrics offers a complete range of fault locating
instruments that enable preventive detection and
location of existing defects in power cables,
communication cables, and water pipelines.

MOT-WARE

Emerging from a deep understanding of domain


knowledge, Motwane has designed and developed a
SAAS-based test data platform: MOT-WARE. Creating
the age of ‘Connected Field Service Engineers’, the
software connects electrical test & measurement
equipment to the cloud, and sends asset health data
from devices onto a single, user-friendly dashboard.

IoTx - Online Transformer Monitoring Solution

IoTx is Motwane’s state-of-the-art Transformer


Monitoring Technology that enables any transformer
to become a ‘Smart Transformer’. Our technology is
designed to be a plug & play solution for
Transformers.
Product & Services 7

Motwane AI & Analytics

Motwane’s proprietary AI algorithm users can now


effortlessly predict behavioral patterns of their assets
based on operating conditions. It offers accurate
insights of an asset’s lifespan, leading to better decision-
making, higher efficiency, better CAPEX and OPEX
planning.

IoXn
Motwane built its proprietary IoXn technology, an
easyto- install ‘plug & play’ product, that connects
various assets: transformers, Chillers, Water Meter,
Motors, etc. to the cloud. Enjoy real-time monitoring
and asset management with the magic of one touch
through MOT-WARE.

Smart Street Lighting Solutions

Focused on offering energy-efficient and ROI-driven


solutions in the field of smart lighting, Motwane’s
latest innovation effortlessly illuminates cities,
industries, campuses, and residential projects with
automated lighting.

Motwane Academy
Motwane academy is built to bridge the skill gap and
enable the future of engineers with better
opportunities and technology.
Test & Measurement - 10K PI 8

Features
Available IR Testing with Diagnostic Modes
PI, DAR, DD, Step Voltage, BDV & Burn Test
Programmable Test Voltage from 500V-10KV
Insulation Resistance Range from 1KΩ to 20TΩ
Three Programmable Timers
Programmable Break Down Current Settings
Mains & Battery operation
Internal Data Storage up to 1000 tests*
Galvanic Isolated RS 232 & USB Port
Application Software for Data Trending Analysis
AC/DC voltage measurement up to 600V
Auto Calibration at every start up
Burn Mode for uninterrupted Insulation Resistance Testing
Alarm Mode with Min-Max Settings & Pass Fail Indication
CAT IV 600V, IP54, Complies with latest IEC/IS Standards
Hand Interlock Switch

10K PI
Diagnostic Insulation Tester

CAT IV IP Applications
600V 54
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
10K PI is an Insulation Diagnostic Tester having test voltage range up
resistance quality of an electrical system degrades with
to 10KV, designed & developed indigenously at the state of the art
time, environment condition i.e. temperature, humidity,
R&D laboratory to conduct automatic insulation tests on high voltage
moisture and dust particles. The instrument is designed for
equipment's like Transformers, Cables, Bushings, Switchgears &
routine insulation resistance testing and diagnostic testing
Rotating Machines 10K PI is a microprocessor based instrument
like PI, DD, DAR & SV of high voltage electric apparatus like
deploying the latest technology & very high speed data sampling to
transformers, generators, motors, cables, bushings, LAs,
give correct, repetitive readings & quality performance under harsh
switchgear, etc. and is temperature independent. Trending
electrical conditions. It has a wide insulation resistance range up to
of data can reveal vital information about insulation quality
20TΩ. and enables the user to take informed decision.

Model 10K PI is mains and battery operated portable & compact


insulation tester for outdoor applications. The battery backup of 6
Hours makes it suitable for field operations. IP54 rating keeps 10K PI
safe from water & dust ingress. It complies with CAT IV 600V for safe
operation. The instruments & its accessories are certified as per
relevant IS/IEC standard.

The Information displayed on the large backlit LCD includes


insulation resistance, leakage current, capacitance, battery status &
timer. Three programmable timers are provided to conduct various
tests like Polarization Index (PI), Dielectric Absorption Ratio (DAR),
Dielectric Discharge (DD), Step Voltage (SV), & Breakdown Voltage
(BDV) Test. 10K PI can store up to 1000 test results*. PC interface via
USB & RS-232 for data transfer. The PC software for report generation
& data trending analysis helps to keep records of capital equipment.
Instrument has automatic discharge facility for capacitive loads
discharging The instrument has the automatic discharge facility for
capacitive load discharge at the end of the test.
Test & Measurement - 10K PI 9

Power Supply
Technical Details 10K PI Mains 85V-265V, 50Hz +10%

Battery Type Li-ion Rechargeable Battery

Battery Backup 6 Hours of continuous testing at 10KV

on load of 100MΩ (approx.)


Test Specifications
Battery Charge Time 8 Hours (approx.)
Diagnostic Modes IR, DAR, PI, DD, SV, BDV, Burn

Test Voltage Environmental Condition

Voltage Selectable 500V, 1KV, 2.5KV, 5KV, 7.5KV, 10KV Operating Temperature 0℃ to 55℃

Programmable 500V to 1KV in 10 V steps Storage Temperature -20℃ to 70℃

1 KV to 10 KV in 25 V steps Humidity <95% RH, non-condensing

Voltage Accuracy ±5 %
Safety Standards
Short Circuit Current 3mA
Safety in accordance with EN61010-1
Resistance Range
EMC in accordance with EN61326-1
Analog Display 1 KΩ to 10 TΩ
Type test in accordance with IEC 60068
Digital Display 1 KΩ to 20 TΩ
Test leads in accordance with IEC61010-31,
Accuracy +5% (Upto 999GΩ )
CE & CAT IV600V, IP 54
+10% (1TΩ to 10TΩ )

+20% (10TΩ to 20TΩ ) Mechanical

Programmable Timer T1, T2 & T3 (0-99Min 59sec) Dimension 195mm(H) X 290mm(W) X 360 mm(L)

Current Measurement Weight 5Kg without accessories (Approx)

Range 0-3mA Gross weight 9.3Kg with accessories (Approx)

Accuracy ± 5% of reading + 5 digits


Data Handling & Analysis Software
Voltage Measurement Operated on XP/Windows7/Windows8/Windows10
Range 0-600V Two way communication for remote operation
Accuracy ± 8% of reading + 5 digits Report generation along with the graphical representation
Capacitance Measurement for Data Trending Analysis.
Range 1nF to 50µF

Accuracy ± 5% of reading + 5 digits Accessories


Noise Rejection
Standard
1mA RMS per KV test voltage, not exceeding 5mA
3 X 3m Test lead with large insulated clip
Memory Mains Power Cord

Internal data storage up to 1000 tests* Instruction Manual


Calibration Certificate
PC Interface
Carry Case
Galvanic isolated USB & RS-232
Optional
Display
3 X 15m Test lead with large insulated clip
Large LCD display with backlit Software CD
RS232 communication cable
USB Cable
Interlock Cable

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - 5K PI 10

Features
Programmable Test Voltage 250 - 5000V in steps of 50V
Insulation Resistance upto 10TΩ
Three Programmable Timers
Modes for conducting IR, Leakage current, PI, DAR,
DD, SV and BDV test
Mains & Battery Operation
CE, CAT-IV 600V, IP65, complies with latest IEC/IS
Standards
1000 test results storage
Optically Isolated RS-232 port & USB port
AC / DC Voltage Measurement
Pass Fail Limit is provided with software generated results
Bluetooth enabled for Motware Mobile App

Connected to Cloud

5K PI
Diagnostic Insulation Tester

CAT III CAT IV IP Applications


600V 600V 65
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
5K PI Insulation Diagnostic Tester is designed to conduct various resistance quality of an electrical system degrades with
diagnostic tests on electrical apparatus like Transformers, Cables, time, environment condition i.e. temperature, humidity,
Bushings, Insulator, Switchgears, Lightning Arrester/Arrestor and moisture and dust particles. The instrument is designed for
Rotating Machines etc. Designed & developed indigenously at the routine and diagnostic testing like IR, PI, DD, DAR & SV of
state of the art, R&D laboratory, the 5K- PI is a microprocessor based high voltage electric apparatus like transformers
instrument deployed with latest technology and very high speed data generators, motors, cables, bushings, LA's, switchgear, etc.
sampling to give correct, repetitive and durable performance under and is temperature independent. Trending of data can reveal
harsh conditions. It is operated through mains and (as well as) the vital information about insulation quality and enables the
battery, weighing less than 5kgs making truly light weight & compact user to take informed decision.
insulation resistance tester for outdoor applications. The instrument
is specially designed to suit operator's ease and test requirement, also
certified as per relevant IS/IEC standards. Instrument has large white
backlit LCD displayed with indication and display test information like
insulation resistance value, test voltage, leakage current, capacitance,
battery status and timer. Equipped with three programmable timers,
which provides to conduct various tests like Polarization Index (PI),
Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Step
Voltage (SV) test and Breakdown Voltage (BDV) test. The instrument
has the automatic capacitive load discharge at the end of the test.

5K-PI has Bluetooth connectivity module with Motware mobile app


for remote access of testing data & in the cloud for further analysis &
record purpose.
Test & Measurement - 5K PI 11

Standards & Approvals


Technical Details 5K PI
Safety In accordance with EN 61010-1

EMC In accordance with EN 61326-1

Type Test In accordance with IS 11994

Ingress Protection IP 65 (closed lead ) IP 40 (open lead )


Test Parameter Specifications
CE & CAT III 600V / CAT IV 600V
Test Regimes (Automatic) IR, Leakage Current, PI, DAR, DD, SV
Safety of Accessories with IEC61010-31
& BDV

Test Voltage 250V - 5KV in 50V steps


Environmental Specifications
Test Voltage Accuracy ± 5%
Operating Temperature 0°C to 55°C
Short Circuit Current 3mA / 5 mA *
Storage Temperature -20°C to 70°C
Three Programmable Timers T1, T2 &T3 (max. 99 min 59 sec.)
Relative Humidity <95% RH, Non condensing
Measurement Ranges
Insulation Resistance Analog Display 1KΩ to 5TΩ

Digital Range (3 Digit Display) 1KΩ to 10TΩ Indications & Annunciations

Accuracy (25°C) +(4% + 5 digits) Audio visual indication for HV presence

LED indication for HV presence

Battery status and charging indication


Guard 2% error guarding<300KΩ leakage

Audible discharge annunciation


with 100MΩ Load.
Mains / Battery Indication
Leakage Current
Range Up to 3mA / 5mA *

Accuracy ± 5% Display Details


Capacitance Real-time display of Insulation Resistance

Range 10nF to 50µF After the end of the test, the result including resistance,

Accuracy +10% of rdg. leakage current, time & capacitance information will be

Voltage Measurement displayed.

Range Upto 600V DC / Upto 600V AC RMS

Accuracy +5% of rdg.


Accessories
Power Supply
Standard
AC Mains Voltage 90 - 270V AC
3 x 3m test leads for Earth, Guard and Line connection
Frequency 50/60Hz with large insulated clamps 1.5m
Battery Internal Rechargeable Battery Main Power Cord
Mains Protected fuse
Backup Approx. 6 Hours of continuous
Instruction Manual
testing at 5KV on a load of 10 GΩ
Carrying Bag
Charging Time 4 Hours (Approx.)
Optional
Interference Rejection 1mA RMS per KV test voltage
3 X 15m Test leads with large insulated clamps
Physical Specifications RS-232 communication cable
Dimensions 195mm(H) x 290mm(W) x 360mm(L) USB Cable

Weight 5Kg. (Excluding Accessories)(Approx) PC Software


Bluetooth enabled for Motware Mobile App
* : Current range 3mA or 5mA supplied as per customer requirement.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - 5K PI 12

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Test & Measurement - IT 51 13

Features
Selectable Test Voltage from 250V, 500V, 1000V, 2500V,
5000V DC.
Insulation Resistance Measurement up to 1TΩ
Polarization Index Measurement Facility
Short Circuit Current < 2 mA + 0.5 mA
AC/DC Voltage Measurement up to 600V.
Two Programmable Timer from 0 sec to 99 minutes
Liquid Crystal Display with pleasant white backlit.
Internal rechargeable Battery.
Safety - IP 54, CAT IV 600V and CE conformity.
Robust ABS body with self-carrying handle for easy
portability.
Automatic discharge for capacitive circuits.
Guard Terminal to minimize the surface leakage
Pass - Fail Limit

IT 51
5KV Digital Insulation Resistance with Polarization Index

CAT IV IP Applications
600V 54
The Insulation Resistance Test is an essential test that help to
verify the condition of electrical insulation. Insulation
The Motwane IT-51 is a microprocessor based Digital Insulation Tester resistance quality of an electrical system degrades with
designed for testing all types of electrical apparatuses like time, environment condition i.e. temperature, humidity,
transformers, switchgears, motors, generators, cable and substation moisture and dust particles. The instrument is designed for
products. IT-51 has a digital display and an analog arc display. The routine and diagnostic testing like IR, PI of high voltage
instrument automatically performs IR Test and Polarization Index Test electric apparatuses like.
by selecting the mode. IT-51 has a large LCD white backlit display, it
shows leakage current in scrolling form along with IR value and PI All electrical rotating machineries
value. Transformers
HV & LV Switchgears
Insulation Resistance Test : The is an important test for future
comparative purposes, acceptance test and also for determining the Cables

suitability of the electrical apparatus of energizing or application of Insulators etc.


the high-potential (hi-pot) test. The IR test must be successfully
completed for factory warranty to be valid. The IR test must be
conducted immediately prior to energizing the electrical apparatus
or beginning the high potential test

Polarization Index Test : This is an extension of the IR test. In this test,


two IR measurements are taken, the first reading at 1 min and the
second reading at 10 min. Then the ratio of the 10 min reading to 1 min
reading is calculated to give the PI dielectric absorption value. A PI of
winding-to-winding and winding-to-ground should be determined. A
PI value below 2 indicates insulation deterioration and the cause for
further investigation.

IT 51 is designed in light portable instrument for electrical tester and it


has a rechargeable battery operated and AC mains provision for
battery charging. Ingress protection IP54. Instrument has an
automatic capacitive load discharge at the end of the test.
Test & Measurement - IT 51 14

Safety and Standards


Technical Details IT 51
Safety in accordance with : EN61010-1 : 2001

EMC in accordance with EN 61326-1 : 2006

Type Test in accordance with IS 11994

Ingress Protection IP54


Terminal Voltage
Test Voltage 250V, 500V, 1000V, 2500V, 5000V CE & CAT IV 600V

Test Voltage Accuracy ± 5 % of rdg Safety of test lead in accordance with

EN61010-031 : 2002 +A1 : 2008


Short Circuit Current 2 mA + 0.5 mA

Programmable Timers T1 and T2

Insulation Resistance
Accessories
Analog Display 1 KΩ to 1 TΩ
Standard
Digital Display 1 KΩ to 1 TΩ (3 Digit Display)
Test leads 3 meter : 1 Set
Insulation Accuracy User Manual : 1 No
Up to 1GΩ All Ranges ± (2 % + 2 digits) Calibration Sheet : 1 No

Over 1GΩ 5000V ± (2% + 0.04% per GΩ)


Optional
2500V ± (2% + 0.08% per GΩ)
Test leads 15 meter : 1 Set
1000V ± (2% + 0.2% per GΩ)

500V ± (2% + 0.4% per GΩ)

250V ± (2% + 0.8% per GΩ)

AC/DC Voltage Measurement


Range Up to 600V

Accuracy +5% of reading + 5 digits

Polarization index (PI)


Display Range 0 - 99.9

Accuracy +5% of reading + 5 digits

Resolution 0.01

Power Supply Specifications

Battery Internal Rechargeable

Display LCD Display with White Backlit

Mains Power Supply 110/ 230VAC 50/60Hz

General

Dimensions 195 mm(H) X 290 mm(W) X 360 mm(L)

Weight 5.0 Kg (Approx) (without Accessories)

Environmental Specifications
Operating Temperature -10°C to 55°C

Storage Temp -20°C to 70°C

Humidity less than 95% RH, non 0° condensing max

at 40°C

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - IT-250G Spot 15

Features
Selectable Test Voltage from 250V, 500V, 1000V, 2500V,
5000V DC
Insulation Resistance Measurement up to 250GΩ
Short Circuit Current < 1.4 mA. approx
Programmable Timer from 1 sec to 99 minutes
Internal Memory Storage of 1000 readings
Auto Power Off to save battery
Auto Calibration at every start up.
Continuity Testing at 100mA approx.
GUARD Terminal to eliminate surface leakages.
Battery Status Indicator
Safety/EMC CE CAT III (1000V)/ CAT IV (600V), IP54
Shock proof, heavy duty & shrouded test lead
Inbuilt Digital Filter

IT-250G
5KV Battery Operated Digital Insulation Resistance

CAT III CAT IV IP


Applications
1000V 600V 54 The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
resistance quality of an electrical system degrades with
The Motwane has been offering comprehensive range of products
time, environment condition i.e. temperature, humidity,
designed in-house catering multiple segments of power and energy
moisture and dust particles. The instrument is designed for
sector. Digital Insulation ester IT-250G Spot is a micro controller
routine and diagnostic testing like IR of high voltage electric
based battery operated insulation tester for measuring insulation of
apparatuses like
all types of electrical equipments. IT250G Spot has a digital and
analog bar graph display designed for high voltage insulation All electrical rotating machineries
resistance testing in the maintenance and servicing of cables, electric
Transformers
motors, transformers, switchgears and industrial installations. DC
HV & LV Switch gears
insulation tests are performed at 250V, 500V, 1000V, 2500V and
Cables
5000V. Insulation resistance measuring range is 1K Ohm to 250G
Ohm. Auto power off feature enhances the battery life and pleasant Insulators etc.

amber backlit allows user to work in dusk environment also. Industrial Purpose

IT-250G Spot is ideally suited for insulation resistance testing during


erection, commissioning or installation at electrical substations,
preventive operation, maintenance and servicing of cables,
transformers at industrial installations. Having robust ABS body , the
instrument comes with rugged strap which gives easy handling
during transit and also in handling while testing at outdoor sites. The
guard terminal features minimize the effects of surface leakages and
give error free measurement. Loaded with multiple proposition,
IT250G Spot addresses the routine insulation testing need of service
providers. It also has continuity range for measuring continuity.
Automatic discharge for charged objects is provided and decaying
discharge voltage is displayed.
Test & Measurement - IT-250G Spot 16

Environmental Specifications
Technical Details IT-250G
Operating Temperature -00C to 500 C

Storage Temp -200C to 600 C

Humidity 90% RH at 00 C to 400 C max.


(Non Condensing).
Terminal Voltage
70% RH at 400 C to 500 C max.
Test Voltage 250V, 500V, 1000V, 2500V, 5000V (Non Condensing).

Test Voltage Accuracy ± 10 % + 5 rdg


Power
Short Circuit Current <1.4 mA (±0.5 mA ) Approx.
Power Supply 8 X 1.5V AA size Alkaline batteries
Overload Protection 230V DC/AC rms for 30sec
(IEC LR6 )
Insulation Resistance
Power Consumption 40mA approx.
Analog Display 1 KΩ to 250GΩ
Power Consumption YES
Digital Display 1 KΩ to 250GΩ
Auto Power Off After 15 min.

Max. Insulation Accuracy +


Test Voltage Idle sleep mode consumption 400µA approx.(When not in use, always keep the
Resistance (% reading + Digit)
rotary switch at OFF position & remove the batteries from the battery
compartment to save the battery life)
250V 12.5GΩ

500V 25GΩ
Safety and Standards (CE Certifications)
1000V 50GΩ ± (5% + 5)
Safety and Standards (CE Certifications)
2500V 125GΩ Measurement Category : CAT IV (600V) Reinforced insulation

5000V Safety : EN 61010‐1


250GΩ
EMC : EN 61326-1
Notes: Test Voltage Accuracy + (10% + 5) is when tested by using 1000MΩ impedance probe
Motwane Make HV 30/HV 40 or equivalent IP rating: IP 54

Continuity
Accessories
Range Accuracy Overload Protection
Standard
0-200Ω ±(3% + 10) 230V DC/AC rms for 30 sec
Test Lead set (3 mtr. Long shrouded banana with
Buzzer will sound < 20Ω approx.
crocodile clip)
Open circuit voltage on continuity range is 8V approx. Red lead for +ve terminal 1 No.
Black lead for ‐ve terminal 1 No.
Short Circuit current is 100mA approx. on Continuity range w.r.t
Green lead for GUARD terminal 1 No.
GUARD/COM terminal (Battery should be in a full charged condition).
Instruction Manual 1 No.
General Specification Calibration Certificate 1 No.
Carrying Bag 1 No.
Insulation Resistance Measurement Digital & Analog (Bar Graph) indication

Display LCD display with Backlit (90 X 60)mm Optional

Dimensions 230 mm(H) X 165 mm(W) X 95 mm(L). Test Lead set (10 mtr. Long shrouded banana with
Weight 1.5 Kg approx. (without accessories) crocodile clip) 1 No.
Red Lead for +ve terminal. 1 No.
Default Test on time 30 sec.
Black Lead for ‐ve terminal 1 No.
Selectable test time 1 sec. to 99 minutes. Green Lead for GUARD terminal

HV ON Indication Visual & Audible. Test Lead set 1 meter long with one end pointed tip &
another with 4mm shrouded banana.
Data Storage functions 1000 readings.
(For continuity range)
Data Recall function.

Auto discharge facility after every test

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - IT-250G Spot 17

Technical Details IT-250G

Accuracy

Accuracy is specified as + (% of reading + digits) and is valid at


25°C + 3°C, 55% RH +10%
Accuracy is valid from 10% of the range to 95% of the range
Temp. Coefficient = (0.2% X Specified accuracy) per degree
centigrade referred to 25°C
Accuracy is not valid if battery status indicator symbol blinks on
display. In this case immediately replace the batteries
It is recommended that calibration equipment used to verify the
accuracy of the instrument should be 10 times more accurate
It is recommended to recalibrate the instrument once in year
Test & Measurement - MIRT61 18

Features
Multi-featured single box design
Wide IR range up to 6GΩ, suitable for all LT applications
Selectable Voltage Facility 50, 100, 250, 500 & 1000V
Maximum test current of 1mA
Industrial Grade True RMS Multimeter functions
Voltage Measurement up to 1OOOV AC/DC
Dual Display LCD with Amber backlit
Auto Power Off Facility, Reading Hold / Lock, Min/Max,
FLT ( Filter )
Bluetooth enabled for Motware Mobile App

Mulitimete
r + IR Test
er
Connected to Cloud

MIRT-61
1KV Digital Multimeter Insulation Tester

CAT IV IP Applications
Ideal for Insulation Resistance Measurement during
1000V 54
maintenance for electrical equipments (Motors,

The Motwane's multipurpose tester model MIRT-61 is a versatile, Transformers, Machines, Switchgears etc.)
battery operated Digital Insulation Tester with true RMS industrial Electrical Wire/Cables for Distribution Networks
grade multimeter features, best suited for industrial preventive Control Panels
maintenance With test voltage range up to 1KV, highest insulation Electrical Contractors
Industrial, Commercial & Residential Installations
resistance range of 6GΩ and multi-featured function of RMS
Railways applications & Telecom applications
multimeter (i.e. AC/DC 1OOOV); makes it a superior offering for the
industry and service segments. It is designed predominantly for low
voltage insulation resistance testing in maintenance and services,
which involves the applications like Cables/Wires, Rotating Machines,
LT transformers, Switchgears and Industrial installations etc. It is
designed to suit the extreme environment conditions. Save your
operating cost and test more with this single box design rather than
buying two different products.

MIRT61 has Bluetooth connectivity module with Motware Mobile App


for remote access of testing data & storage in the cloud for further
analysis & record purpose.
Test & Measurement - MIRT61 19

Overload Protection
Technical Details MIRT61
Fuse protection for 'mA' Input Terminal
0.8A/250V fast blow type,
Ceramic fuse

Ω/ / / /Hz (%)/IRT 440V DC / AC rms

General
Safety CE Certifications
Display 6000 counts, LCD with amber backlit
Directives for CE Certification: LVD: 2006/95/EC,
Polarity Automatic
EMC: 2004/104/EC.
Display Update Rate 3 Times per second nominal
Measurement Category: CAT IV (1000V) Reinforced insulation.
DCV, ACV, Resistance, Capacitance, Relevant Standard (S): EN61010-1, EN61326-1
Ranges
Frequency, AC/DC Current, IRT
IP Rating (dust & water protection) : IP 54.

Dimensions 102mm(H) X 209mm(W) X 44mm(L).

Weight 620 gm. (with battery) approx. Accessories


Indications Low battery Indication “ ”below 6.5V approx. Standard

Auto Power Off After 10 mins Test lead set Red & Black one end with shrouded

Resistance Range banana 4 mm & another with crocodile clip : 1 Set

Range 600Ω- 60MΩ (0.1Ω to 10KΩ resolution ) Test lead Green, one end with shrouded banana 4 mm

Accuracy & another with crocodile clip : 1 No


+(1.2%+3) upto 600KΩ
Test lead set with one end pointed tip & another with
+(1.5%+5) from 600 KΩ to 6 MΩ
4mm shrouded banana: 1 Set
+(3%+5) from 6MΩ to 60MΩ
Batteries 1.5V AA Alkaline (IEC LR6) (Duracell Only): 6 Nos.
Capacitance Range
Instruction Manual: 1 No.
Range 6nF - 60mF ( 0.001nF to 10uF resolution )
Carrying Bag: 1 No.
Accuracy +(3%+10) upto 600uF
Calibration Certificate
+(5%+20) from 600uF - 60uF
Optional
Diode Test
Bluetooth option for Motware Mobile App.
Range 6V ( 1mV resolution )

Continuity Test

600.0Ω ( 0.10 resolution ) Meter Beeps


Range
at < 60Ω approx.

Frequency Range (Auto Ranging Only)


Range 60Hz - 60MHz

Resolution 0.01Hz

Accuracy ± (0.1%+3)
Overload Protection 1000V DC/AC rms

Duty Cycle Measurement

Range 0.1% - 99.9% ( with resolution 0.1% )

Accuracy +(0.5%+3 Digit)

Environmental
Operating Temperature 0°C to 50°C

Storage Temperature -20°C to 60°C

Relative Humidity 80% RH@ 5°C to 31°C , 50 % RH@ 31°C

to 40°C,Non-condensing
Test & Measurement - MIRT61 20

Technical Details MIRT61

DC and AC Voltage Measurement


DC Accuracy AC Accuracy
Range Max. Measur- Overload
No. Resolution Reading ement ± (reading ± (reading Protection
+ digit) + digit)

1050V
1 600mV 0.1mV 600.0mV DC +(0.9%+3) N/A DC/AC rms

2 6V 1mV 6.000V AC/DC +(0.9%+3) +(1%+5)

3 60V 10mV 60V AC/DC +(0.9%+3) +(1%+5)

4 600V 100mV 600V AC/DC +(0.9%+3) +(1%+5)

5 1000V 1V 1000V AC/DC +(0.9%+3) +(1.2%+8)

DC And AC Current Range


DC Accuracy AC Accuracy
Range Max. Overload
No. Resolution Reading ± (reading ± (reading Protection
+ digit) + digit)

0.8A/250V fast
1 600mA 0.1mA 600.0 mA +(1%+5) +(1.2%+5) blow type ceramic
fuse

Insulation Test
Output Range Resistance Accuracy
Resolution Test Current
Voltage (Auto Ranging only) +(% of rdg + Digits)

50 V 1 mA approx@
30 to 300 kO 1 kO +(3% + 5 counts)
+(10%+5) 50 kO
0.30 to 3.00 MO 0.01 MO
3.0 to 30.0 MO 0.1 MO
30 to 300 MO 1 MO
100 V 1 mA approx@
60 to 600 kO 1 kO +(3% + 5 counts)
+(10%+5) 100 kO
0.60 to 6.00 MO 0.01 MO
6.0 to 60.0 MO 0.1 MO
60 to 600 MO 1 MO
250 V 1 mA approx@
0.15MO to 1.50 MO 0.01 MO +(1.5% + 5 counts)
+(10%+5) 250 kO
1.5to 15.0 MO 0.1 MO
15 to 150 MO 1 MO
0.15 to 1.50 GO 0.01 GO
500 V 1 mA approx@
0.30MO to 3.00 MO 0.01 MO +(1.5% + 5 counts)
+(10%+5) 500 kO
3.0 to 30.0 MO 0.1 MO
30 to 300 MO 1 MO
0.30 to 3.00 GO 0.01 GO
1000 V 1 mA approx@
0.60MO to 6.00 MO 0.01 MO +(10% + 3 counts)
+(10%+5) 1MO
6.0 to 60.0 MO 0.1 MO
60 to 600 MO 1 MO
0.60 to 6.00 GO 0.01GO
Test & Measurement - MIRT61 21

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Test & Measurement - i-12 22

Features
Smart
Go-No-Go Test Facility.
Pre selectable Timer Facility.
Mains Eliminator.
Selectable Voltage Facility 50, 100, 250, 500 & 1000V.
Auto Ranging Measurement from 10KΩ to 2GΩ - wide range
Live Circuit Detection up to 600V AC/DC.
Low Resistance Measurement up to 100Ω with continuity testing.
Temporary Storage of 10 readings.
User Selectable Backlit to measurement in dark environment.
Low Battery Indication.
Auto Power Off Facility.
Blown Fuse Indication.
Safe
CE mark conforming to latest EN 61010-1:2010.
EN 61326-1:2005, CAT IV 600V, IP54 protection.
Overload protection 1200V for all ranges.
Guard Terminal to minimize surface leakage.

Strong
i-12 Robust and Rugged Polycarbonate casing.
1KV Battery Operated Digital Insulation Resistance

CAT III CAT IV IP Applications


1000V 600V 54
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
The Motwane's Digital Insulation Tester model i-12 is a compact, light- resistance quality of an electrical system degrades with
weight, hand held, battery and mains operated (with the help of time, environment condition i.e. temperature, humidity,
mains eliminator) best suited for industrial use. i-12 is a 1kV insulation moisture and dust particles. The instrument is designed for
tester with maximum range of 2GΩ for Insulation Resistance routine and diagnostic testing like IR of high voltage electric
Measurement and is designed predominantly for low voltage apparatuses and useful to the following segments:
insulation resistance testing in maintenance and services, which
involves the applications like Cables, Rotating Machines, LT Electrical Equipment
Transformers, Switchgears and Industrial installations. It has (Motors, Transformers, Machines, etc.)
selectable test voltages of 50V, 100V, 250V, 500V and 1000V. The Industrial, Commercial & Residential Installations.
insulation tester is provided with additional low resistance Cables for Distribution or Communication Networks.
measurement and AC/DC voltage measurements to. It is designed to House Hold Appliances
suit the extreme environment conditions (Washing Machines, Mixer, Toaster, etc.)
Control Panels.
Railway and Metal Industry Applications.
Metal Industry Applications
Test & Measurement - i-12 23

Power
Technical Details i-12
Battery : 6 X 1.5V cells IEC LR6 Alkaline

(Nickel Cadmium rechargeable cells may also used)

(Battery symbol appears on the LCD screen, battery replacement

is necessary.)

Genera Mains Eliminator

Input : 230VAC, 50/60Hz


Display 1/
3 digit LCD with backlit
2

Output : 12 VDC, 1000mA


Analog Display Logarithmic Scale

Display 7 segment digits

Enclosure Material Polycarbonate Safety


CE Mark
Dimensions 102 mm(W) x 209 mm(H) x 44mm(D)
Directives for CE : LVD:2006/95/EC.,
Net Weight (Instrument) Approx. 60g (With battery excluding accessories)
EMC : 2004/104/EC
Gross Weight (with Accessories) Approx. 1 Kg. Measurement Category : CAT III 1000V/CAT IV 600V Reinforced

Environmental Insulation

0 0 Relevant Standard Specifications : EN61010-1:2010,


Nominal Temp. Range 0 C to 35 C
EN61326-1:2005
Operating Temp. -200C to 400C (Full Range)
IP Rating (Dust & Water Protection) : IP 54
200C to 600C (Up to 100M Ω ) Type tested as per : IS 10656

Storage Temp. 0
-25 C to 65 C 0

Relative Humidity 90% RH at 400C max


Accessories
Technical
Standard
Measurement Accuracy Overload
Range Resolution
Function ± (% reading+dgt) Protection Set of test leads of 1m length with crocodile clips
Instruction Manual
Insulation 0.01 MΩ to 0.99 MΩ 10 KΩ (0.01 MΩ ) ± (3% ± 2) 1200 V rms
Resistance (10 sec) Warranty Card
>1.0 M Ωto 99.9 M Ω 100 KΩ (0.1 M Ω ) ± (5% ± 2)
MΩ *1 Batteries 6 X 1.5V AA, Alkaline (IEC LR6)
(50V,100V) >100 MΩ to 999 MΩ 1MΩ ±(10%± 5) Fuse (800mA/600V)
0.01 MΩ to 9.99 MΩ 10 K Ω(0.01 M Ω ) ± (5% ± 2)
Insulation Optional
Resistance >10 M Ω to 99.9 MΩ 100 K Ω (0.01 MΩ ) ± (5% ± 2)
MΩ /G Ω*1
Mains eliminator (12 VDC, 1000mA output)
(250V,500 >100 MΩ to 999 MΩ 1 MΩ ±(10%± 5) Test lead set
V,1000V)
1G Ω to 2G Ω 10M Ω ±(10%± 5)

0 - 9.99 Ω 0.01Ω at 100 mA ± (3% ± 2)


Low Ohms
( Ω ) *2
>10 Ω to 99.9 Ω 0.1Ω at 10 mA ± (5% ± 2)

Continuity Test
0 - 9.99 Ω 0.01 Ω ± (3% ± 2)
Current 100mA

25V - 450V 1V ± (2% ± 2)


V AC/DC
450V - 600V 1V ± 3%

*1 For Insulation resistance range,

Terminal voltage on Open Circuit (DC) : - 0% to + 30% of rated voltage

Short Circuit current : < 2 mA

*2 For low Ohms/Continuity Ranges

*Open Circuit Voltage : 5V + 2V d.c.

*Lead Resistance compensation : 0 - 9.99Ω

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM - 10 24

Features
Test Current 10A, 1A, 100mA & 10mA & Resistance
up to 2000Ω
Resolution of 0.1μΩ with +0.2% Accuracy
High Open Circuit Voltage for quick stabilization
Dual Channel Resistance Measurement
Heat Run Test Facility
OLTC Test Facility
Auto Discharge
Internal Memory for 100 test results
USB interface with software for Report Generation

XWRM - 10
Transformer Winding Resistance Meter

CAT IV IP Applications
600V 54 XWRM-10 is perfectly suitable for measurements of cold and
hot winding resistances of Transformer winding. The
XWRM-10 is a dual channel 10A rated, transformer winding resistance instrument is designed for testing of power transformers as
meter designed for accurate & fast measurement of highly inductive well as distribution transformer. Trending of data can reveal
loads such as Transformers, Reactors & HT Motors etc. The instrument vital information about deterioration, incipient faults in tap
has one current channel and two resistance channels and the changer and enables user to take informed decision
selectable smooth DC test current useful to test windings with regarding maintenance.
different ratings. The instrument provides a large open circuit voltage
XWRM-10 is useful to the following segments:
of 42 Volts, for fast charging of the highly inductive windings of
transformers, to provide stable resistance values in minimum time. Power and Distribution Transformer
The XWRM-10 is intended to replace a complex bridge set up with a Motor and Generator
single compact instrument. The instrument is well protected against Heat Run Test
the inductive kickbacks offered by the inductive windings

XWRM-10 has a special feature to conduct heat run tests on


transformers. The periodic samples of readings of both channels are
stored in a special memory which can be uploaded to a PC. The
Windows based software is provided with instruments for
calculations of temperature rise in windings from the recorded
resistance values. The software can also be used for data
management, graph plotting, analysis and report generation. The
instrument can be operated through software. It has an additional
feature of detecting open OLTC conditions, thereby indicating the
healthiness of OLTC. The windings are automatically discharged after
the test, for the safety of the operator.
Transformer Testing Instruments - XWRM - 10 25

Environmental
Technical Details XWRM-10
Operating Temperature -00C to 550 C

Storage Temperature -100C to 550 C

Humidity <90% RH, Non condensing

Technical Specifications
Power Supply 115/230VAC,50/60 Hz
Physical Specifications
Dimensions 520mm(L) x 425mm(W) x 230mm(D)
Test Current 10A, 1A, 100mA & 10mA
Weight 11 Kg (Approx)
Open Circuit Test Voltage 42 VDC

Burden 420VA

Resistance Measurement Range Software Details


Resistance Range 0.1 µΩ to 2k Ω Type Windows based Analytical Software

Accuracy +(0.2% of rdg. + 5counts) Data Transfer Real Time Data Transfer

Resolution 0.1 µΩ Features Online Data Acquisition

Range Maximum Graph Plotting for Heat Run Test


Resolution
Test Current Display
(Ω) (Ω) Remote Operation
(Ω)

10A 1A 100mA 10mA Test Report Generation

P 2m Ω 0.1uΩ 1.9999mΩ

P P 20m Ω 1uΩ 19.999mΩ Accessories


P P P P 200mΩ 10u Ω 199.99mΩ
Standard
P P P P 2Ω 0.1mΩ 1.9999 Ω
15 meter measuring test lead set (1 current channel,
P P P 20 Ω 1m Ω 19.999 Ω 2 resistance channels)

P P 200Ω 10mΩ 199.99 Ω Mains Power cord


Short Links
P 2000Ω 0.1 Ω 1999.9 Ω
Earthing Lead
General User Manual

Principle 4 wire measurement Calibration Certificate


Carry Case for Test leads
Measurement Channel 2 Resistance & 1 Current channels

Display LCD Optional

Keypad Sealed soft touch keypad Software


USB cord
Indication LED and Beep during Test On & Discharge.

PC Interface USB

Internal memory 100 test readings

Safety & Standards


Ingress Protection IP 54

CE Certification

Safety Meets requirement of IEC 61010-1

EMC Meets requirement of IEC 61326-1

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.

**** Please refer catalogue for technical specification.


Transformer Testing Instruments - XWRM - 10A 26

Features
Test Current : 10A, 5A, 1A, 100mA & 10mA
Resolution of 0.1μΩ with +0.1% Accuracy
3 independent resistance measuring channels
Auto Range Facility
Heat Run Test Facility
48V Open Circuit Voltage for stable readings
Demagnetization Test Facility
OLTC dynamic test with Graph : Time vs Current
In-built Thermal Printer & Memory
Bluetooth enabled for Motware Mobile App
Temperature Measurement & Correction
Emergency Stop Switch

Connected to Cloud

XWRM-10A
Transformer Winding Resistance Meter

CAT III IP Applications


Winding Resistance Test is an essential test which enables to
600V 54
identify shorted turns, loose connections, or deteriorating
contacts in tap changers and measurements on all tap
XWRM-10A transformer winding resistance meter designed for
changer positions in transformer (if present) and compared
accurate & fast measurement of highly inductive loads such as
to previous or factory test values for evaluating the
Transformers, Reactors & HT Motors etc. The selectable smooth DC
condition of the transformer windings and leads. The
test current is useful to test windings with different ratings. 48V open
acceptance criteria for the field-measured values should be
circuit voltage saturates the core in quick time in order to get stable
within 3% of the factory values. A change greater than the
readings. The three resistance measurement channels for
acceptance criteria is indicative of short-circuited turns,
simultaneous measurement of three windings reduces testing time.
poor joints, or bad tap changer contacts. This test should be
The heat run test feature is available with graphical representation
performed during acceptance testing and when other
through software and also has a demagnetization facility, which
maintenance electrical tests are conducted.
eliminates the magnetic remanence effects. XWRM-10A has a facility
to test the make-before-break operation of on-load tap-changers Power Distribution Transformer
which helps in the analysis of OLTC switch contacts. The Back EMF Motor and Generator
feature protects XWRM-10A from high inductive kickbacks. The large Reactor
LCD display with keypad provides easy operation. Also have an
Heat Run Test
internal memory to store 2000 test results and inbuilt thermal printer
provided for onsite report.

XWRM10A has Bluetooth connectivity module with Motware mobile


app for remote access of testing data & storage in the cloud for
further analysis & record purpose
Transformer Testing Instruments - XWRM - 10A 27

Safety & Standards


Ingress Protection : IP54
Technical Details XWRM-10A
CE Certification
Safety : Meets requirement of IEC 61010-1
EMC : Meets requirement of IEC 61326-1

Technical Specifications Environmental


Power Supply 115/230VAC,50/60 Hz
Operating Temperature 0°C to 55°C

Test Current
Storage Temperature -10°C to 60°C
10A, 5A, 1A, 100mA & 10mA 95% RH, Non condensing
Humidity
Open Circuit Test Voltage 48 VDC

Burden 500 VA Physical Specifications


Resistance Measurement Range Physical Specifications 485mm x 392mm x 192mm

10 Kg (Approx)
Accuracy +(0.1% of rdg. + 5 counts) Weight

Analytic Software
Range Maximum
Resolution
Test Current Display Type Windows based analytical software
(Ω) (Ω)
(Ω)
Data Transfer Real time data transfer
10A 5A 1A 100mA 10mA Features Online data acquisition
Graph plotting for heat run test
P 2m Ω 0.1uΩ 1.9999mΩ
& OLTC dynamic test
P P 20m Ω 1uΩ 19.999mΩ Remote operation
Test report generation
P P P 200mΩ 10u Ω 199.99mΩ

P P P P 2Ω 0.1mΩ 1.9999 Ω
Accessories
P P P 20 Ω 1m Ω 19.999 Ω
Standard
P P 200Ω 10mΩ 199.99 Ω
15 meter measuring test lead set with alligator clamp
P 2000Ω 0.1 Ω 1999.9 Ω
Mains Power cord
P 4m Ω 4µΩ 4.0000m Ω
Short links - 2Nos.
P 40mΩ 1µ Ω 40.000m Ω Earthing lead
User Manual
P 400m Ω 10µΩ 400.00m Ω
Calibration Certificate
P 4Ω 0.1mΩ 4.0000m Ω
Carry Case for Test leads

Optional

General OLTC Probe

Principle 4 wire measurement PC Software


USB Cord
Measurement Channel 3 Resistance & 1 Current channels
Temperature Sensor
Temperature Channel 2 Channel
20 Mtr. Test Leads with alligator clamp
Temperature Range 0 - 100°C Test Leads with C clamp

Display LCD Bluetooth application via cloud based


Motware application
Indication LED & Beep during test ON, & discharge.

PC Interface USB

Internal Memory 2000 test readings

Printer Inbuilt thermal printer

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM - 10A 28

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Transformer Testing Instruments - XWRM-25A 29

Features
Test Current : 25A, 10A, 5A, 1A, 100mA & 10mA
Resolution of 0.1μΩ with + 0.1% Accuracy
3 independent channels for resistance measuring
Auto Range Facility
Heat Run Test Facility
60V High Open Circuit Voltage for stable readings
Demagnetization Facility
OLTC Dynamic Resistance Test with Graph: Time vs Current
Inbuilt Thermal Printer & Memory
Bluetooth enabled for Motware Mobile App
Temperature Measurement & Correction
Emergency Stop Switch

Connected to Cloud

XWRM-25A
Winding Resistance Meter

CAT III IP Applications


600V 54 Winding Resistance Test is an essential test which enables to
identify shorted turns, loose connections, or deteriorating
XWRM-25A transformer is a Winding Resistance Meter designed for contacts in tap changers and measurements on all tap
accurate & fast measurement of highly inductive loads such as changer positions in transformer (if present) and compared
Transformers, Reactors, Generator & HT Motors etc. The selectable to previous or factory test values for evaluating the
smooth DC test current is useful to test transformer with different condition of the transformer windings and leads. The
power ratings. Higher Open Circuit voltage saturate the core in acceptance criteria for the field-measured values should be
quickly in order to get stable readings. The three resistance within 3% of the factory values. A change greater than the
measurement channels for simultaneous measurement of three acceptance criteria is indicative of short-circuited turns,
windings help to reduce testing time. The heat run test feature is poor joints, or bad tap changer contacts. This test should be
available with graphical representation through software and also has performed during acceptance testing and when other
demagnetization facility, which eliminates the magnetic remanence maintenance electrical tests are conducted.
effects. XWRM-25A has facility to test make-before-break operation
of on-load tap-changers which helps in the analysis of OLTC switch Power Transformer
contacts. The Back EMF feature protects XWRM-10A from high Motor and Generator
inductive kickbacks. The large LCD display with keypad provides easy Reactor
operation. It also has the Software for remote operation and detail Heat Run Test
report generation. Also have an internal memory to store 2000 test OLTC Dynamic Test
results and inbuilt thermal printer provided for onsite report.

XWRM25A has Bluetooth connectivity module with Motware mobile


app for remote access of testing data & storage in the cloud for
further analysis & record purpose.
Transformer Testing Instruments - XWRM-25A 30

Display LCD

Indication LED & Beep during test ON, & discharge.


Technical Details XWRM-25A
PC Interface USB

Internal Memory 2000 test readings

Printer Inbuilt thermal printer

Technical Specifications Safety & Standards

Power Supply 115/230VAC, 50/60 Hz Safety & Standards : IP54

CE Certification

Safety : Meets requirement of IEC 61010-1


Test Current 25A, 10A, 5A, 1A, 100mA & 10mA
EMC : Meets requirement of IEC 61326-1
Open-Circuit Test Voltage 60 VDC

Burden 1500 W
Environmental
Resistance Measurement Range
Operating Temperature 0°C to 55°C
Accuracy +(0.1% of rdg. + 5 counts)
Storage Temperature -10°C to 60°C

Humidity 95% RH, Non condensing


Range Maximum
Resolution
Test Current Display
(Ω) (Ω) Physical Specifications
(Ω)

10A 5A 1A 100mA 10mA Physical Specifications 525 x 437 x 213

15 Kg (Approx)
P 2m Ω 0.1uΩ 1.9999mΩ Weight

P P 20m Ω 1uΩ 19.999mΩ


Software Details
P P P 200mΩ 10u Ω 199.99mΩ Type Windows based analytical software

P P P P 2Ω 0.1mΩ 1.9999 Ω Data Transfer Real time data transfer

Features Online Data Acquisition


P P P 20 Ω 1m Ω 19.999 Ω
Graph Plotting for Heat Run Test
P P 200Ω 10mΩ 199.99 Ω & OLTC Dynamic Test
Remote Operation
P 2000Ω 0.1 Ω 1999.9 Ω
Test Report Generation
P 4m Ω 4µΩ 4.0000m Ω

P 40mΩ 1µ Ω 40.000m Ω Accessories


P 400m Ω 10µΩ 400.00m Ω Standard

P 4Ω 0.1mΩ 4.0000m Ω 15 meter measuring test lead set


Mains cord
Short links - 2Nos.
General Earthing lead
Principle 4 wire measurement User Manual
Calibration Certificate
Measurement Channel 3 Resistance & 1 Current channels
Carry Case for Test leads
Temperature Channel 2 Channel
Optional
Temperature Range 0 - 100°C
OLTC Probe
PC Software
USB Cord
Temperature Sensor
20 Mtr. Test Leads with alligator clamp
Test Leads with C clamp
Bluetooth application via cloud based Motware
application

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM-25A 31

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Transformer Testing Instruments - XTRM-3 32

Features
Test Voltage : 10V, 40V, 100V
Measure Turns Ratio, Voltage Ratio & Ratio Error
Measure Phase Deviation & Excitation Current
Auto Detection of Transformer Vector Group
Quick set up with intuitive guide
Inbuilt Printer with Memory for 500 test results
Bluetooth enabled for Motware Mobile App

Connected to Cloud

XTRM-3
Transformer Turns Ratio Meter

CAT III IP Applications


600V 54 Transformer Turn Ratio Meter determines the turns ratio and
polarity of single and three-phase transformers and also
confirm nameplate ratio, polarity, and vectors and useful in
Motwane's Transformer Turns ratio Meter XTRM-3 is a new generation
identifying trouble in the in transformer windings, such as
fully automated kit to measure Turns Ratio, Voltage Ratio, Ratio Error,
open circuit and short circuit of turn-to-turn sensitivity.
Phase Displacement and Excitation Current in Transformer. It also
automatically detects transformer vector group. User selectable test Turn Ratio testing of Single phase/ Three phase
voltage provided to test various ratings of power transformers. Auto Transformers, Power Transformers and
XTRM-3 controls from remote position using TAP changer option
Distribution Transformers
which allows operator to perform measurement at various Tap
Turn Ratio testing of Instument Transformers
position and has quick setup templates which automatically
calculates nameplate voltage ratios of transformer to avoid time
consuming process by adding details of each TAP ratio. Internal
memory for 500 test results provided to save results during testing on
site. Emergency safety switch is provided for operator's safety during
undesired condition.

XTRM-3 has Bluetooth connectivity module with Motware mobile


app for remote access of testing data & storage in the cloud for
further analysis & record purpose.
Transformer Testing Instruments - XTRM-3 33

Safety Features
Technical Details XTRM-3
Safety / EMC in accordance with EN 61010-1, EN 61326-1
CE Certified
Ingress Protection IP54 / CAT III 600V
Emergency Stop
Technical Specifications
Power Supply 115V/230V AC, 50/60 Hz Full Windows Compatible Software
Measurement ratio 0.8 : 10000 Software is fully compatible with Microsoft

Type Window based Software

Ratio Accuracy Interface USB communication port

10V +0.15% (0.8 - 999) Features Remote Operation

Data Downloading

40V +0.1% (0.8 - 999) Analysis and Report Generation

+0.15% (1000 - 1999)

+0.20% (2000 - 3999)


Accessories
+0.25% (4000 - 10000)
Standard

+0.1% (0.8 - 999) Mains Power Cord


100V
15m Measuring Test Lead Set with alligator clips
+0.15% (1000 - 1999)
Thermal Paper roll
+0.20% (2000 - 3999) Instruction Manual

+0.25% (4000 - 10000) Calibration Certificate

Optional

Test Voltage 10V AC, 40V AC, 100V AC Software 1 No

Excitation Current Upto 2A USB Cable 1 No


Remote tap changer switch 1 No
Resolution 0.1mA
20 Mtr. Test Leads with alligator clamp
Phase Angle +1800 Bluetooth application via cloud based
Phase Angle Resolution 0.01 Motware application

Accuracy +0.500 + 1digit

Display LCD

Printer Built in Thermal Printer

PC interface USB

Report Storage 500 reports

Environmental Specifications
Operating Temperature 00C to 400C

Storage Temperature -100C to 600C

Relative Humidity <95%RH at 400C max (non condensing)

Physical Specifications
Dimensions 502mm(H) x 401mm(W) x 188 mm(L)

Weigh 15 kg (Approx)
Transformer Testing Instruments - XTRM-3 34

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Test & Measurement - MOTR 35

Features
Dissipation Factor , Volume Resistivity, Dielectric Constant
(Permittivity), Watt Loss
Inbuilt Oil Heating Chamber with precise temperature control
Test Cell according to IEC 60247
Preprogrammed & Customized Test Sequences
Inbuilt Thermal Printer
Internal Memory for 250 Test
USB Interface
Portable Calibrator
Oil Auto Drain Facility
Auto Sequence Test
Bluetooth enabled for Motware Mobile App

MOTR Connected to Cloud

Oil Tan Delta & Resistivity Tester

CAT III IP
Applications
600V 54 The dissipation factor indicates the dielectric loss of the
liquid and thus it's dielectric heating. The dissipation factor
test is widely used as an acceptance and preventive
Motwane's MOTR is a microprocessor-based compact designed for
maintenance test for insulating oil. The dissipation factor of
precise measurement of the dissipation factor and volume resistivity
new oil should not exceed 0.05 % and the dissipation factor
of insulating oils. MOTR is built in a single unit and on boarded with
can gradually increase in service to a value as high as 0.5%,
international test standards for automatic measurement of all
i n m o st c a s e s , i n d i c a t i n g d e te r i o ra t i o n a n d /o r
parameters and also available with customized test sequences to
contamination with moisture, carbon, varnish, glyptal,
conduct tests as per the user's requirement. The test cell is designed
sodium soaps, or deterioration products.
as per IEC 60247 with precise control for measuring dissipation factor
and resistivity at 27°C & 90°C. MOTR also has an auto drain facility. It is Used Oil having a dissipation factor of less than 0.5% is
provided with internal memory & printer for on-field reports and also usually considered satisfactory for service and with
has a USB interface available for data transfer. The calibrator with dissipation factor between 0.5% and 2% should be
standard dissipation factor & resistivity ranges are available for considered as being in doubtful and further investigation
validating the performance of MOTR. recommended and in excess of 2.0 % may be an
operational hazard. It should be reconditioned or replaced.
MOTR has a Bluetooth connectivity module with Motware mobile app
for remote access of testing data & storage in the cloud for further Useful for measuring the quality of insulating oil, used in
analysis & record purposes. electrical apparatuses like:

Power & Distribution Transformers


OLTC
HV Cables
Switchgear
Capacitor
Bushing
Instrument Transformer
Test & Measurement - MOTR 36

Heater
Technical Details MOTR
Temperature Range 20°C - 150°C

Accuracy +0.5°C

Resolution 0.1°C

Technical Specification Temperature Control One set point (max110°C)

AC Voltage 400-2400 V Heating Element Induction Type

Resolution 1V Sensor Solid state (PT100)

Accuracy +1%

Test Standards IEC 60247, VDE 0380, BS 5737,


ASTM D924, ASTM D1169, JISC2101:2010
DC Voltage 100 – 1000V
Display Alphanumeric LCD Display
Resolution 1V
Printer Inbuilt Thermal Printer
Accuracy +1%
Memory 250 Test

Power Supply 110V / 230V, 50/60Hz +15%


Dissipation Factor 10e-5 – 4.0

Resolution 1 X 10-5
Operating Temperature -100C to 500C, 90% non condensing
Accuracy +1% of rdg + 0.0001 (1 X 10-4)
Safety Standards IEC61010-1, IEC61326-1

Dimension 510mm(H) X 320mm(W) X 380mm(L)


Capacitance 0 -1600 pF
Weight 24 Kg (Approx)
Resolution 0.01 pF

Accuracy +0.1% +1pF

Accessories
Dielectric Loss 0 -10.0 watts Standard

Resolution 0.001 mili Watts Test Lead sets

Accuracy Oil Test Cell with 3 Terminals


+1% of Reading + 10-5 Watts
Standard Calibrator
Pen drive loaded with MOTR software
Dielectric Constant 1-30 software

Resolution 0.001 USB Cord


Calibration Certificate
Transportation case
Resistivity 10e9Ω cm to 10e15 Ω cm
Optional
Accuracy + 2% of rdg at 10e9 – 10e13Ω cm
Motware Mobile App
+ 5% of rdg at 10e13 – 10e15Ω cm
Oil Auto Drain Facility
+ 10% of rdg above 10e15 Ω cm

Test Cell
Cell Constant 620 Nominal

Capacitance 55pF + 1pF

Insulation Teflon (PTFE)

Electrode Spacing 2mm

Volume of Oil 60ml

Calibrator Test Cell


Test & Measurement - MOTR+ 37

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Transformer Testing Instruments - OTS 38

Features
Fully Automatic Microprocessor based
Pre-programmed International Test Standards
Customized Test Sequences
Voltage Slew Monitoring: Real Breakdown Monitoring (RBM)
Upgraded Sequence as per IEC60156-2018
Suitable to test Mineral, Ester & Synthetic Oil
Internal Memory up to 100 Test
USB Interface
Inbuilt Thermal Printer
Voltage Checker for onsite Calibration
Bluetooth enabled for Motware Mobile App

Connected to Cloud

OTS-60A/80A/100A
Automatic Oil Insulating Test Set

Applications
Transformer oil is used as insulating medium in transformer,
switchgear and other electrical apparatuses and it also acts
as a coolant which dissipates (or to dissipate) heat of the
OTS-A series is a fully automatic microprocessor-based Oil BDV
transformer. In addition to these, insulating oil serves other
Tester designed with advanced technologies to measure the
purposes like, it helps to preserve the core and winding as
electrical breakdown strength of insulating oil. OTS-A has a quick
these are fully immersed inside oil and another important
sensing ability to measure accurate breakdown voltage. OTS-A series
purpose of Insulating oil is, it prevents direct contact of
is equipped with national & international standards for test sequences
atmospheric oxygen with cellulose made of paper insulation
and it also has has user-friendly customized test sequences. The large
used in windings, which is susceptible to oxidation. When
LCD display with keypad provides easy operation. It is provided with
insulating oil deteriorates due to aging / contamination
internal memory for 100 data storage & inbuilt thermal printer for the
which leads to catastrophic event due to flashover in
onsite report. As for safety, the OTS-A series has open ground
insulation. The voltage withstands capability of oil which
detection feature to avoid damage. The molded oil test vessel is
often is reduced ( which often reduces) due to
suitable to test Mineral, Easter & Synthetic Oil and it is provided with
contamination like dirt, water ingress and foreign particles.
an adjustable electrode gap setting to conduct the test as per
standards. The portable voltage checker is useful for onsite
The Motwane's OTS-A series useful for Oil Testing
calibration verification.
in the following equipments:
OTS-A series has a Bluetooth connectivity module with Motware
mobile app for remote access of testing data & storage in the cloud Power and Distribution Transformer
for further analysis & record purposes. Bushing
Instrument Transformer
Switchgear
Capacitors
Transformer Testing Instruments - OTS 39

Accessories
Technical Details OTS-60A/80A/100A
Standard

Oil test vessel with Mushroom Electrode Assembly


Magnetic Oil Stirrer
Retriever for magnetic stirrer
Technical Specification Electrode gauge set - 1.0mm / 2.0mm / 2.5mm /
2.54 mm / 4.0mm
Mains Supply 110V/230V, +10%, 50/60Hz
Pendrive loaded with OTS software
Output Voltage 0 - 100kV (OTS - 100A)
USB Cord
0 - 80kV (OTS - 80A) Mains Power Cord
User Manual
0 - 60kV (OTS - 60A)
Calibration Certificate
Voltage Accuracy +1% +2digits
Spherical Electrodes Set
Voltage Resolution 0.1kV Flat Electrodes Set

Switch-Off Time 0.5kV to 5kV/sec Optional


Voltage Checker
Switch-off time <10μ Sec
Motware Mobile App
Pre-Programmed Standards

IEC 60156-2018, IEC 60156-1995, IS6792, ASTM D877, ASTM D1816,

UNE 21, BS5730A, BS 148, BS5874, VDE 0370, NFC 27, CE1344,

OCT 6581, SABS 555, AS1767, STA 8286, IP 295

Customized Test Standards 10

Programmable Parameters Stand time – 0 to 999 secs

Stirring Time – 0 to 999 secs

Intermediate Stand time – 0 to 999 secs

Voltage Ramp-up– 0.5kV/sec to 5kV/sec

Iterations - 24

Temperature Measurement 0 – 99.9°C

Temperature Resolution 0.1°C

PC Interface USB

Printer Inbuilt Thermal Printer

Internal Memory 100 Rest Results

Display Large LCD Colour Display

Protection
Zero Start and HT Cover Open Interlock

Auto Trip and Reset

Open Ground Protection

Overload Protection

Environmental Condition 0°C to +55°C, <90% RH, Non Condensing

Safety Standards IEC 61010-1 : 2010 AMD : 2016

EMC Standards IEC61326

Dimension 650 mm(H) X 320 mm(W) X 361 mm(L)

Weight 39 Kg (Approx)
Transformer Testing Instruments - OTS 40

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Transformer Testing Instruments - OTS 41

Features
Motorized Operation with 2kV/s ramp rate
Safety Door & Zero Start Interlock
Digital Display with optional Hold Facility till Variac
goes zero position
Voltage Checker for onsite checking (optional)
Earth Open Interlock
Bluetooth enabled for Motware Mobile App

Connected to Cloud

OTS-60DS/80DS/100DS
Digital Oil Insulation Test Set

Applications
Transformer oil is used as insulating medium in transformer,
switchgear and other electrical apparatuses and it also acts
Motwane offers a wide range of Oil Breakdown Voltage test kits to as coolant to dissipate heat of the transformer. In addition to
check dielectric strength of insulating oil used in Transformers, these, Insulating Oil serves other purposes like it helps to
Capacitors, Switchgears and Instrument Transformer for safe preserve the core and winding as these are fully immersed
operation and maintenance. OTS-DS series Series is meeting to inside oil and another important purpose of insulating oil is,
national & international standards for conducting BDV Test. It is also it prevents direct contact of atmospheric oxygen with
facilitated with ZZero Start Interlock and Earth Open Interlock for cellulose made of paper insulation used in windings, which is
safety and avoid hazards. Also equipped with LED (Digital Display) susceptible to oxidation. When insulating oil deteriorates
along with Hold Facility. Designed with unmatched quality and due to aging / contamination which leads to catastrophic
improved reliability and safety having earth & zero start, safety door event due to flash over in insulation. The voltage withstands
interlock ensuring high degree of protection. OTS comes with two capability of oil which often is reduced (which often
variants models- OTS-A series - a pre-programmed fully Automatic reduces) to contamination like dirt, water ingress and
Oil BDV kit and OTS-DS Series - Motorized with Digital Display. foreign particles.

OTS-DS series useful for Oil Testing in following


equipment's

Power and Distribution Transformer


Bushing
Instrument Transformer
Switchgear
Capacitors
Transformer Testing Instruments - OTS 42

Accessories
Technical Details OTS-60DS/80DS/100DS
Standard

Oil test vessel with Mushroom Electrode Assembly


Magnetic Oil Stirrer
Lifting stick for Magnetic Stirrer
Technical Specification
Go - No - Go Gauge
Mains Supply 110V/230VAC +10% 50/60Hz Single Phase
Mains Power Cord
Output Voltage 0 - 100kV (OTS - 100DS) User Manual
Calibration Certificate
0 - 80kV (OTS - 80DS)
Earth Lead
0 - 60kV (OTS - 60DS)
Spanner
Voltage Accuracy + 2% + 2digits Spare Fuses

Voltage Resolution 0.1kV


Optional
Voltage Rise Rate 2kV/sec
Voltage Checker
Bluetooth enabled & Motware Mobile App

Standards complying IEC 60156, IS6792

Display 3 ½ digit LED digital

Earth Open Interlocking

Protection Zero Start Interlock

Safety Door Interlock

Earth Open Interlock

Overload Protection

Operating Temperature 0°C to 55°C, <90% RH, Non condensing

Storage Temperature -10°C to 55°C

Dimension 650mm(H) X 320mm(W) X 361mm(L)

Weight < 39kg


Transformer Testing Instruments - OTS 43

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Transformer Testing Instruments - Analog 44

Features
Motorized-cum-Manual Operation.
Safety Interlock Door
Analog Voltmeter with Memory Effect.
Earth Open Interlock
Oil Test Set meeting standards IS6792: 1992
Continuous variable Output Voltages

ANALOG OTS-60/80/100
Analog Oil Insulation Test Set

Motwane offers a wide range of Oil Breakdown Voltage Test kits to


check dielectric strength of insulating oil used in Transformers,
Applications
Capacitors, Switchgear and Instrument Transformer for safe The Oil BDV Test method is intended for an acceptance of
operation and maintenance. OTS Analog Series is IS6792-1992 new insulating oil at the time of oil filling. Transformer oil is
standards for conducting BDV Test. It has motorized-cum-manual used as insulating medium in transformer, switchgear and
operation. Designed with unmatched quality and improved reliability other electrical apparatuses and it also acts as a coolant to
and safety having earth & zero start, safety door interlock ensuring dissipate heat of the transformer. In addition to these,
high degree of protection and to avoid hazards. The output voltmeter insulating oil serves other purposes like it helps to preserve
is with memory effect i.e even after HV supply trip off due to the the core and winding as these are fully immersed inside oil
failure of equipment under test, the voltmeter continues to show the and another important purpose of Insulating oil is, it
voltage at which breakdown has been occurred. prevents direct contact of atmospheric oxygen with
cellulose made of paper insulation used in windings, which
is susceptible to oxidation. When insulating oil
deterioration due to aging / contamination leads to
catastrophic event due to flashover in insulation. The
voltage withstands capability of oil often reduced due to
contamination like dirt, water ingress and foreign particles.

Analog OTS series useful for Oil Testing in the


following equipments:

Power and Distribution Transformer


Bushing
Instrument Transformer
Switchgear
Capacitors
Transformer Testing Instruments - Analog 45

Technical Details ANALOG OTS-60/80/100 Accessories


Standard

Mains Power Cord


Test Cell with Electrodes
Technical Specification Magnetic Oil Stirrer (Optional)
Mains Supply 230VAC+10% 50/60Hz Go - No - Go Gauge
User Manual
Output Voltage 0 - 100kV
Calibration Certificate
0 - 80kV

0 - 60kV

Standards IS6792

Display A linear scaled AC rectifier voltmeter

marked kV to measure output voltage.

HV Indication Mains 'ON' and H.T 'ON' Indication

Mode of Operation Motorized-cum-Manual Operation

Protection HV Chamber Door Interlocking

Earth Open Interlocking


Transformer Testing Instruments - VC-100 46

Technical Details VC - 100

Technical Specification
Display

31/2 Digit LCD Display

Voltage Range

10kVAC - 90kVAC

Resolution

0.1 kV

Measurement Accuracy at 250C

+1%+1kV upto 75kV and +2% + 1 kV above 75kV

VC-100
Voltage Calibrator For Oil Test Set Operating Temperature

00C to +550C
The VC-100 is a calibration meter suitable for verifying the calibration
of oil test sets. The high voltage output is measured between both
terminals using the VC 100 meter. The meter will enable the high Storage Temperature
voltage output to be checked, traceable to national standards. The -100C to 700C
VC 100 meter fits in the oil test set chamber in place of oil test vessel
in all models of OTS-A series and OTS-DS series for calibration. The
voltage indication is viewed on a digital display and voltage range Humidity
10KV AC - 90KV AC. Also high voltage attenuator chain moulded in
<90% non-condernsing
epoxy avoids moisture absorption or leakage. The meter is supplied
with protective carrying case.

Dimensions
Features 258 mm (L) x 180 mm (B) x 116 mm (H) Approx.
Measures relative output voltage between both
terminals Oil Dielectric Test Set
Direct Digital Display read out in kV. True RMS Weight

Voltage reading < 3 Kg Approx. (without carrying case)


High Voltage Attenuator chain melded in epoxy avoids
moisture absorption or leakage
Fits perfect place of oil vessel in all models of OTS-100A/
Accessories
OTS-100DS series. Standard

Voltage Checker : 1 Nos

Carrying Case : 1 Nos


Contact Resistance/Low Resistance Meter - PCRM-200S 47

Features
100A & 200A Pulsating DC selectable Test Current
Resistance Range : 0.1μΩ to 20mΩ, Autoranging
Direct mV Drop Reading
Built in Thermal Printer
Internal Memory of 500 test results
Mains and Battery Operated
USB Interface for Data Transfer
LED Indication for Mains/Battery/LOBAT
Calibration Due Indicator
Dual Grounding Facility
Conformity IP54, CE
Bluetooth enabled for Motware Mobile App

Connected to Cloud

PCRM200S
Contact Resistance Meter

CAT II IP Applications
300 54 Stationary and moving contacts are built from alloys that are
formulated to endure the stresses of electrical arcing.
The Motwane's Digital Contact Resistance Meter, Model However, if contacts are not maintained on a regular basis,
PCRM-200S is specially designed to measure extremely low their electrical resistance due to repeated arcing builds up,
resistances in micro ohm. The Instrument is based on Kelvin 4- wire resulting in a significant decrease in the contact's ability to
connection method for measurement of low resistance. User carry current and increase in resistance. Excessive corrosion
selectable current injection is 100A/200A. PCRM 200S has large LCD of contacts is detrimental to the breaker performance.
with backlight and display real time test information like injected Hence to check contacts is to apply DC and measure the
current with measured resistance value & voltage drop. User friendly contact resistance or voltage drop across the closed
instrument and it comes with heavy duty cable with clamps for contacts. The use of a higher current value gives more
accurate measurement and accessories are housed in easy reliable results than using lower current values. The
transportation case. Advance Windows based software is provided resistance value is usually measured in micro ohms (µΩ).
for data downloading, analysis and report generation. Internal
PCRM-200S is specially used to measure static contact
memory of 199 records is provided for onsite data storage and inbuilt
resistance of LV, HV, EHV circuit breaker contacts installed in
thermal printer to print the test results at the field.
energised switchyards. High accuracy and repeatability
PCRM 200S has dual ground technique to test circuit breaker with makes it a reliable tool for Quality Assurance and easy
both side grounded, which is safer to conduct test in substation. operation makes it a very handy tool for quick maintenance
checks in various industries
PCRM 200S has Bluetooth connectivity module with Motware mobile
app for remote access of testing data & storage in the cloud for Typical resistance measurement applications are
further analysis & record purpose. Circuit Breaker contact resistance
Bus bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-200S 48

Software Details
Technical Details PCRM 200S
Type Windows based software

Interface USB

Data Transfer Real Time Data

Internal Data Storage 500 Test results


Technical Specification
Features Remote Operation
Test Current Injection 100A & 200A Pulsating DC selectable
Data down loading
Test ON Alert BEEP
Analysis and report generation
Range & Resolution 20µΩ with 0.1µΩ

200µΩ with 0.1 µΩ


Accessories
2000µΩ with 1µΩ
Standard
20mΩ with 0.01mΩ
15 meter lead set with C Clamp 75mm opening
Master Earthing Cable (7 meter)
Measurement Principle Four wire measurement Mains power cord

Basic Accuracy + 1% of reading, + 5 digits User Manual


Calibration Certificate
Memory Storage 500 reading storage facility
Thermal Paper Role
Computer Interface USB Spare Fuse (250mA/250V slow blow)

Thermal Printer For printing the test results.


Optional
Display Custom Built 3 ½ digit LCD Display with Backlit
22 meter lead set with C Clamp 150mm jaw size
Physical Specifications 15 meter heavy duty lead set with alligator clip

Enclosure Material Industrial grade Polypropylene Software and USB Cord


Bluetooth application via cloud based
Dimensions (DxWxL) 188mm x 395mm x 502mm
Motware application
Weight 13 Kg (Approx)

Power Supply
Mains 115V-230V, 50Hz / 60Hz Single phase AC supply

Battery Rechargeable Li-ion

Power Consumption 35VA, 6.0 Watt on battery

Environmental
Operating Temperature 0°C to 55°C.

Storage Temperature 0°C to 50°C.

Humidity less than 95% RH, Non condensing.

Safety Standards
Safety According to EN 61010 - 1

EMC According to EN 61326 - 1

IP Rating IP 54

Measurement Category CAT II

CE Certification LVD: 2006/95/EC

EMC Certification 2004/104/EC

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - PCRM-200S 49

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Contact Resistance/Low Resistance Meter - PCRM-100S 50

Features
100A Pulsating DC Test Current
Resistance Range : 0.1μΩ to 2mΩ Autoranging
Direct mV Drop Reading
Built in Thermal Printer
Internal Memory of 500 test results
Mains and Battery Operated
USB Interface for Data Transfer
LED Indication for Mains/Battery/LOBAT
Calibration Due Indicator
Dual Grounding Facility
Conformity IP54, CE
Bluetooth enabled for Motware Mobile App

Connected to Cloud

PCRM 100S
Contact Resistance Meter

CAT II IP Applications
300 54 Stationary and moving contacts are built from alloys that are
formulated to endure the stresses of electrical arcing.
The Motwane's Digital Contact Resistance Meter, model However, if contacts are not maintained on a regular basis,
PCRM-100S is specially designed to measure extremely low their electrical resistance due to repeated arcing builds up,
resistances in micro ohm. The instrument is based on Kelvin 4- wire resulting in a significant decrease in the contact's ability to
connection method for measurement of low resistance. Selectable carry current and increase in resistance. Excessive corrosion
current injection is 100A. PCRM 100S has a large LCD with backlight of contacts is detrimental to the breaker performance.
and display real time test information like injected current with Hence to check contacts, apply DC and measure the contact
measured resistance value & voltage drop. It is a user-friendly resistance or voltage drop across the closed contacts. The
instrument and it's comes with heavy duty cable with clamps for use of a higher current value gives more reliable results than
accurate measurement and accessories are housed in easy using lower current values. The resistance value is usually
transportation case. Advance Windows based software is provided measured in micro ohms (μΩ).
for data downloading, analysis and report generation. Internal
PCRM-100S is specially used to measure static contact
memory of 99 records is provided for onsite data storage and inbuilt
resistance of LV, HV, EHV circuit breaker contacts installed in
thermal printer to print the test results at the field.
energised switchyards. High accuracy and repeatability
PCRM 100S has dual ground technique to test circuit breaker with makes it a reliable tool for Quality Assurance and easy
both side grounded, which is safer to conduct test in substation. operation makes it a very handy tool for quick maintenance
checks in various industries.
PCRM 100S has Bluetooth connectivity module with Motware mobile
app for remote access of testing data & storage in the cloud for Typical resistance measurement applications are
further analysis & record purpose. Circuit Breaker contact resistance
Bus Bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-100S 51

Software Details
Technical Details PCRM 100S
Type Windows based software

Interface USB

Data Transfer Real Time Data

Internal Data Storage 500 Test results


Technical Specification
Features Remote Operation
Test Current Injection 100 A Pulsating DC
Data down loading
Test ON Alert BEEP
Analysis and report generation
Range & Resolution 200µΩ with 0.1 µΩ

2000 µΩ with 1 µΩ

Measurement Principle Four wire measurement Accessories


Basic Accuracy + 1% of reading, + 5 digits
Standard
Memory Storage 500 reading storage facility 15 meter lead set with C Clamp 75mm opening
Computer Interface USB Master Earthing Cable (7 meter)
Mains power cord
Thermal Printer For printing the test results.
User Manual
Display Custom Built 3 ½ digit LCD Display with Backlit Calibration Certificate
Thermal Paper Role
Spare Fuse (250mA/250V slow blow)
Physical Specifications

Enclosure Material Industrial grade Polypropylene Optional

Dimensions (DxWxL) 365mm x 465mm x 185mm


22 meter lead set with C Clamp 150mm jaw size
15 meter heavy duty lead set with alligator clip
Weight 11 Kg (Approx)
Software and USB Cord
Bluetooth application via cloud based
Power Supply Motware application

Mains 115V-230V, 50Hz / 60Hz Single phase AC supply

Battery Rechargeable Li-ion

Power Consumption 35VA, 6.0 Watt on battery

Environmental
Operating Temperature 0°C to 55°C.

Storage Temperature 0°C to 50°C.

Humidity less than 95% RH, Non condensing

Safety Standards
Safety According to EN 61010 - 1

EMC According to EN 61326 - 1

IP Rating IP 54

Measurement Category CAT II

CE Certification LVD: 2006/95/EC

EMC Certification 2004/104/EC

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - PCRM-100S 52

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Contact Resistance/Low Resistance Meter - PCRM-100SM 53

Features
100A True DC Test Current
Resistance Range : 0.1µΩ to 2mΩ
Direct mV Drop Reading
Internal Memory of 100 test
Dual Grounding Facility
Light weight & Portable
Rust Removing C Clamp

PCRM 100SM
Contact Resistance Meter

Applications
Stationary and moving contacts are built from alloys that
are formulated to endure the stresses of electrical arcing.
However, if contacts are not maintained on a regular basis,
Motwane's PCRM-100SM is True DC Contact resistance meter
their electrical resistance due to repeated arcing builds up,
designed for accurate and reliable result at a very reasonable cost.
resulting in a significant decrease in the contact's ability to
The instrument is based on Kelvin 4- wire connection method for
carry current and increase in resistance. Excessive
measurement of low resistance. PCRM 100SM has true 100A DC test
corrosion of contacts is detrimental to the breaker
current suitable for testing Circuit Breaker, Bus Bar, Isolator and Cable
performance. Hence to check contacts is to apply DC and
etc. PCRM 100SM has dual ground feature considering safety of
measure the contact resistance or voltage drop across the
operator and equipment. PCRM100SM is very light weight and
closed contacts. The use of a higher current value gives
portable with heavy duty test leads with C clamp and crocodile clips
more reliable results than using lower current values. The
to suit different applications.
resistance value is usually measured in micro ohms ( µΩ ).

PCRM-100SM is specially used to measure static contact


resistance of LV, HV, EHV circuit breaker contacts installed
in energised switchyards. High accuracy and repeatability
makes it a reliable tool for Quality Assurance and easy
operation makes it a very handy tool for quick maintenance
checks in various industries.

Typical resistance measurement applications are

Circuit Breaker contact resistance


Bus Bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-100SM 54

Accessories
Technical Details PCRM 100SM
Standard

15 meter lead set with C Clamp 75mm opening


Master Earthing Cable (5 meter)
Mains power cord
Technical Specification
User Manual
Test Current Injection 100A DC Calibration Certificate
Range & Resolution 200µΩ with 0.1 µΩ Spare Fuse (250mA/250V slow blow)
Carry Case
2000 µΩ with 1 µΩ
Optional
Basic Accuracy + 2% of reading, + 1 digits
22 meter lead set with
(From 10% of the range)
C Clamp 50mm jaw size
Measurement Principle Four wire measurement
C Clamp 100mm jaw size
Display 3 ½ LCD with Backlit C Clamp 150mm jaw size

Memory Storage 100 Test Heavy duty crocodile clip 32mm Jaw Size.
15 meter Cable (heavy crocodile clip 32mm Jaw opening)

Physical Specifications
Dimensions 320 mm(D) x 435 mm(W) x 188 mm(L)

Weight 7 Kg Approx

Power Supply

Mains 115V-230V, 50Hz / 60Hz Single phase AC supply

Power Consumption 35VA

Environmental
Operating Temperature 0°C to 50°C.

Storage Temperature 0°C to 55°C.

Humidity less than 95% RH, Non condensing

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - CRM100A 55

Features
Continuously selectable Current In steps of 10, 20,
50 & 100A resp.
Digital Resistance Reading from 0.1μΩ to 20mΩ.
Simultaneous Display of Test Current, Resistance
Minimum Resolution of 0.1μΩ
Accuracy + (0.5% +5 digits)
3 1 ⁄ 2- digit readings for resistance.
Custom built backlit LCD with sealed soft touch
membrane keypad.
Data Exchange to PC through USB Interface.
Built-in Memory to store up to 99 test results.
Test 'ON' indicator with LED & beep, provided to signify
the flow of Direct Current DUT.

CRM 100A
Contact Resistance Meter

Applications
Stationary and moving contacts are built from alloys that
are formulated to endure the stresses of electrical arcing.
The Motwane's Contact Resistance Meter- CRM 100A is a digital However, if contacts are not maintained on a regular basis,
micro ohmmeter, designed to measure extremely low resistance. The their electrical resistance due to repeated arcing builds up,
instrument is based on the proven 4-wire measurement method for resulting in a significant decrease in the contact's ability to
low resistances to eliminate the effect of lead resistance of two wire carry current and increase in resistance. Excessive corrosion
method. The instrument is designed to replace complex bridge set up of contacts is detrimental to the breaker performance.
with a single compact unit. The DC current injection in continuously Hence to check contact, apply DC and measure the contact
adjustable between 10A to 100A. The testing information is displayed resistance or voltage drop across the closed contacts. The
on large LCD with backlit, real time data is displayed during the test use of a higher current value gives more reliable results than
using lower current values. The resistance value is usually
ON condition. The instrument gives a high resolution of 0.1 μΩ on 200
measured in micro ohms (μΩ).
μΩ resistance range.
CRM 100A has a large application for direct and indirect
The instrument is easy to operate and user friendly. Accessories are
measurements in various industries and manufacturing
rugged and come with heavy duty clips for better grip on test object.
facilities. High accuracy makes it a reliable tool for Quality
The kit and accessories are housed in a trolley mounted casing for
Assurance and easy operation makes it a very handy tool for
easy transportation. Advanced Dot Net based software is provided
quick maintenance checks for process industries.
for data downloading, analysis and report generation. The instrument
can be operated through software from a remote location. Internal
memory is provided for onsite data storage. Typical resistance measurement applications are

Circuit Breaker Contact Resistance in non-energized areas


Electrode Resistance Measurement
Bus Bar joints
Isolator Contacts
Cable Drum Resistance Measurement
Cable Splice
Weld Joints
Bond Resistance
Contact Resistance/Low Resistance Meter - CRM100A 56

Safety Standards
Technical Details CRM 100A
Safety : According to EN 61010 - 1

EMC : According to EN 61326 - 1

Power Supply
Accessories
Standard
Input Power 230V+ 10%, 50 Hz, 1 Phase
Output lead Set 4 X 5m
DC Test Current 10A, 20A, 50A & 100A
Mains Power Cord
Accuracy 5%
Mains Protection fuse 5A
Resolutions 0.1 A User Manual

Open Circuit Voltage 5V DC Calibration Certificate


Carrying Case
0/P Power 500 VA
Optional

Software CD
Resistance Measurement
USB Cord
Resistance Ranges 200µΩ 2m Ω 20mΩ

Resolution 0.1μΩ 1μΩ 10μΩ

Accuracy +(0.5% + 5 digits)

Operation Time
Continuous Operation up to 50A

4 minutes-ON and 10 minutes-OFF for 100A

Display 3 ½ digit Large LCD Display

PC interface USB for data transfer

Warning
Audio Visual Indication for Test ON Operation

Indication on Mains ON Operation

Blinking display for Over range indication

Environment
Operating Temperature 0°C to 55°C

Storage Temperature -10°C to 55°C

Humidity < 90% RH, Non condensing

Physical

Dimensions 365 mm(D) x 426 mm(W) x 178 mm(H)

Weight 12 Kg (Approx)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.

Note : Do not use this instrument in HT switchyard


Micro Ohm Metre - LR 2065S 57

Features
4.3” Color TFT display with backlit
Resolution 0.1 μΩ on 2 mΩ range
Best Measurement Accuracy of 0.03 %
Mains cum Battery operated.
High measurement current (10A) for faster settling of
measured values on low resistance.
True 4 wire resistance measuring technique
Pulse Mode, Auto Hold Operation.
Bluetooth interface and cloud connectivity through
Motware app
Inbuilt thermal paper printer
Low Battery indication to prevent deep discharge of
internal recharging battery.
Temperature Measurement & Correction

Connected to Cloud

LR 2065S
10 (AMPS CURRENT)

CAT III IP Applications


600V 54 High Precise micro ohmmeter used for measuring accurate
low resistance with high accuracy, makes it a reliable tool
Motwane's Digital micro ohm meter LR 2065S with maximum 10A DC for Quality Assurance and easy operation and also makes it
current injection is useful for the measurement of very low resistance a very handy for quick maintenance checks for process
industries, typical It is very useful in design, test, mainte-
in micro Ω as low as 0.1 μΩ. Mains cum rechargeable battery operated
nance, QC/QA and production. Typical applications include
LR 2065S, works on the proven principle of 4-wire measurements.
the measurement of
The LR 2065S is having 4 digit LCD display with resistance
measurement range from 2mΩ to 20KΩ, with minimum resolution of Cables
0.1μΩ. The pulse mode operation is an additional feature. The LR Components
2065S can be used for measuring resistance of cables, wires, PCB Relays
Relays, LT bus-bar, Graphite electrode, Quality testing of resistive PC Boards
components, Low capacity motors etc. Bus Bars
Contactors
LR-2065S has Bluetooth connectivity module with Motware mobile
Low rating motors & transformers
app for remote access of testing data & storage at cloud for further
Wed Joints
analysis & record purpose.
Electrodes
Micro Ohm Metre - LR 2065S 58

Safety
Technical Details LR 2065S Measurement Category: CAT II (1000V)/CAT III (600V)
Reinforced insulation
Relevant Standard Specifications: Safety According to
EN 61010-1,EMC According to EN 61326-1

Printer Built in Thermal Printer


Accessories
PC Interface USB
Standard
Report Storage 1000 Reports
Test Lead set 1meter : 1 Set.
Temperature correction Manual entry or Temperature Probe
Mains Power Cord : 1 No.
Temperature Channel 1 Mains Protected Fuse : 1 No.
Thermal Paper roll : 1 No.
Dimensions 360.68 mm(L) X 289.56 mm(W) X 165.1 mm(H)
Instruction Manual : 1 No.
Net Weight 6.0Kg Approx. Calibration Certificate : 1 No.

Optional

Environmental USB cable : 1 No.


Temperature measurement probe : 1 No.
Operating Temperature 00C to 550C

Storage Temperature -100C to 600C

Relative Humidity 95 % RH at 400C max. (Non Condensing)

Power
Mains Power Supply Mains Input Voltage 115/230 Volt AC, 50/60Hz

Battery Power Supply Li-Ion Battery 14.8 V

Electrical Specifications
At 25°C +3°C 55% RH+10% Temp. Co. 150 ppm/°C

Test Current Injection 10A, 1A, 100mA, 10mA, 1mA, 100mA

Test ON Alert BEEP

Resistance Range

Max MAX ACCURACY


Range Resolution
Reading CURRENT ± (%RDG + DIGITS)

*2mΩ 1.9999mΩ 0.1μΩ 10A ± 0.03 % of reading ± 4 digits

20mΩ 19.999mΩ 1μΩ 1A ± 0.03 % of reading ± 4 digits

200mΩ 199.99mΩ 10μΩ 100mA ± 0.03 % of reading ± 4 digits

2Ω 1.9999Ω 100Ω 10mA ± 0.03 % of reading ± 4 digits

20Ω 19.999Ω 1mΩ 100mA ± 0.03 % of reading ± 4 digits

200Ω 199.99Ω 10mΩ 10mA ± 0.03 % of reading ± 4 digits

2000Ω 1999.9Ω 100mΩ 1mA ± 0.03 % of reading ± 4 digits

20KΩ 19999mΩ 1Ω 100μA ± 0.03 % of reading ± 4 digits

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Micro Ohm Metre - LR 2065S 59

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Contact Resistance/Low Resistance Meter - LR 2045S 60

Features
Back-EMF Protection
Heat Run Test
Best Measurement Accuracy of 0.05 %
Bluetooth Interface And Cloud Connectivity Through
Motware App
The Inbuilt Thermal Paper Printer
Temperature Measurement & Temperature Correction
Feature.
4¼ Digit Large And Clear Display
Accurate & Stable Readings
Pc Interfacing With Software
4 Wire Measurement Method
Sealed Soft Touch Membrane Keypad
Temperature Measurement & Correction

Connected to Cloud

LR 2045S
Micro Ohm Meter

Applications
Hot & Cold Winding Resistance Measurement of Motors,
The Motwane LR 2045S capable of measuring low resistance with 1
Generators, Alternators, and Transformers.
micro-ohm resolution. It employs the proven 4-wire (4W)
Contact Resistance Measurement of Fuses and
measurement where fixed DC current is supplied to DUT and voltage
Miniature Circuit Breakers.
drop across the DUT is measured and displayed as proportional
Resistance Measurement of Cables & Wires.
resistance reading. The meter is able to deliver guaranteed stable
readings on inductive as well as resistive loads.
Contact Resistance/Low Resistance Meter - LR 2045 61

Safety
Technical Details LR 2045S Measurement Category: CAT II (1000V)/CAT III (600V)
Reinforced insulation
Relevant Standard Specifications: Safety According to
EN 61010-1, EMC According to EN 61326-1

Technical Specification Protection


Display 4.3” Color TFT with backlit Protection against EMF : 12KV-(1.2/50µ sec.pulse).
Instrument Protected against mains overload
Temperature correction Range 0 to 100 deg,
(Fuse 250mA)
Accuracy + 1 deg, Resolution 0.1deg. All ranges are fuse protected. (Input fuse 1A).

Temperature Channel 1
Physical Specifications:
Printer Built in Thermal Printer
Dimensions : 360.68 mm (L) X 289.56 mm (W) X 165.1 mm (H)
PC Interface USB Net Weight : 6.0kg (Approx)

Report Storage 1000 Reports

Accessories
Indications
Standard
4.3” Color TFT with backlit or range and Ω/mΩ indications.
Test Lead set 10meter : 1 Set.
LED indication for operation and pulse mode. Mains Power Cord : 1 No.
Mains Protected Fuse : 1 No.
Over range indication: Blinking zero display.
Thermal Paper roll : 1 No.
Under Range Indication: All Display shows zero. (Not blinking) Instruction Manual : 1 No.
Calibration Certificate : 1 No.

Optional
Technical Specifications :
USB cable : 1 No.
MAX ACCURACY Temperature measurement probe : 1 No.
Range Resolution
CURRENT ± (%RDG + DIGITS)

20mΩ 1μΩ 1A ± 0.05 % of reading ± 5 digits

200mΩ 10μΩ 1A ± 0.05 % of reading ± 5 digits

2000mΩ 100μΩ 100mA ± 0.05 % of reading ± 5 digits

20Ω 1mΩ 10mA ± 0.05 % of reading ± 5 digits

200Ω 10mΩ 1mA ± 0.05 % of reading ± 5 digits

2000Ω 100mΩ 100uA ± 0.05 % of reading ± 5 digits

Note : Accuracies are valid from 1/10th of the range to FS of range & valid

Temperature 25°C + 3°C at 55% + 10%RH.

Temperature Coefficient 100ppm/°C.

Open Circuit Voltage 15Volt ± 3volt.

Power Supply Mains Input Voltage115/230VAC,

50/60Hz

Environmental Specifications:

Operating Temperature 0°C-55°C.

Storage Temperature 10°C -60°C.

Relative Humidity 95 % RH at 400C max.

(Non Condensing)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - LR 2045 62

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Protection Testing - MCBT-P 63

Features
Lightweight and Portable
Testing up to 6 Main + 6 PIR
High resolution of 0.05ms
Programmable delays in OC, CO cycle
Internal Memory for 200 Results
Calibration Due Indicator
Comes with Inbuilt Battery and
Thermal Printer

MCBT-P
Circuit Breaker Timer Kit

Applications
Circuit Breaker Testing (AIS, VCB) Gas Insulated
Switchgear Testing Drive Switch/Earth Switch Testing
MCBT-P is a microprocessor-based second generation circuit breaker Isolator /Disconnect or Testing
time interval meter. It measures the Closing, Opening, CO and OC
Measurements
times of various types of circuit breakers up to 400kV. The equipment
is capable of testing up to 6 Main and 6 PIR contacts at a time under Main Contact Timing
hostile EHV switch yard conditions. MCBT-P has a compact and PIR Contact Timing
lightweight construction. This makes it ideal for reliable Number of Bounces
measurements during periodic maintenance and inspection of circuit Bounce Duration
breakers. Contact Mismatch
Protection Testing - MCBT-P 64

Technical Details MCBT-P

Contact Channels 6 Main + 6 PIR

Sampling Speed 20kC, 10C, 5kC, 2C, 1kC, 500Hz and 100Hz selectable

0 - 1000 mSec @ 20kHz, 0 - 2000 mSec @ 5kHz, 0 - 10000 Sec @ 1kHz,

Plot Length 0 - 1000 mSec @ 20kHz, 0 - 5000 Sec @ 2kHz 0 - 50000 mSec @ 500Hz,

and 0 - 100000 mSec @ 100Hz

0.05mSec @ 20kHz 0.2 mSec @ 5kHz, 1 mSec @ 1kHz,

Resolution 0.1 mSec @ 10kHz, 0.5 mSec @ 2kHz 2 mSec @ 500Hz

and 10 mSec @ 100Hz

Accuracy Value 0.05% + 1 Digit

Breaker Control Two solid state contacts rated at 35A, 300V AC/DC for breaker operation

Trigger Options Open, Close, C-O, O-C (Delay between operations selectable)

Special Cycle Duty Cycle "O-0.3Sec-CO-3Min-Co" Operation Only with Fixed Delay)

Display 4 lines x 20 characters backlit LCD

Printer 56 mm paper width, thermal printer

Keypad 5 Keys

Memory Upto 200 results

Built-in Li-Ion Battery Li-lon, 11.1 V, 4 Ah

Power Input to Instrument: 230 V AC, 50 Hz + 15% Instrument consumption: 15 VA

Communication Serial (RS 232C) and USB (Through Converter)

Window PC Software for MCBT-P


Software
Optional : “Motware" - Windows based Software for downloading test results and analysis

Environment 00C to 500C, 95% RH (non-condensing), Electrical noise normally found in charged HV switchyards

Dimensions 380 mm x 260 mm x 175 mm

Weight 7 kg

IEC 364-4-41 Protection against electric shock

IEC 1010-1 Safety requirements for electrical equipment for Measurement, control & laboratory use.

IP 54/IEC 529 Weather Proof Standards.

Type Test IEC 68-2/ IS 9000 Basic Environmental Testing Procedures covering shock, bump and vibration tests.

IEC 61326 EMC Standards

IEC 359 Humidity

IEC 61000 EMI/EMC/ Safety environment requirement for EHV switchyard


Protection Testing - MCBT-P 65

Technical Details MCBT-P

User Benefits
Simultaneous measurement of 6 Main and 6 PIR contacts i.e. 2 Main and 2 PIR per pole.

Easy to use with backlit LCD Display and a special purpose keypad.

Continuous indication of breaker contact status by using LEDs.

Special operation of O-0.3 Sec-CO-3Min-CO (Operation only)

The highest sampling rates of 20 kHz offers a high resolution of 0.05ms.

Special facility of programmable delay Too for CO operation.

Special facility of programmable delay Toc for OC operation.

Dual-powered with AC mains or through built-in Li-Ion battery with quick charging and long battery back-up.

Battery protection from overcharging and deep discharge.

Inbuilt Real-time clock which enables report printing with date and time stamp using an onboard thermal printer

Up to 200 results can be stored along with the date and time stamp on the internal memory.

User-friendly Windows software for downloading test results, performing trend analysis, and generating test reports.

Supplied in Lightweight, military-grade ABS Case (IP67 class).

Rugged and easy-to-connect test leads for timing measurement (15 meters) and breaker control (7 meters).

Accessories
Contact Timing Cable, 15m 3 Nos

Breaker Control Cable, 7m 1 Nos

Master Earthing Cable 7m 1 Nos

Mains cord, 3m 1 Nos

Communication Cable 1.5m 1 Nos

USB to Serial (RS232) Converter 1 Nos

Printer Paper Roll 1 Set

Spare Fuses 1 Set

Soft Carrying Case For Test Leads 1 Nos

PC Downloading & Analysis Software on CD 1No

Printer Paper Roll. One fitted in instrument + One in TLS case 1 No

Operation cum Instruction Manual 1 Set


Protection Testing - MCBOA Plus 66

Features
Tests all types of circuit breakers from LV to UHV up to
1200 kV in switchyard conditions.
Completely modular analyzer allowing the user to select
the configuration as per their specific requirements.
Timing measurements for up to 12 Main, 12 PIR, and 8
Auxiliary contacts.
Rotary and linear travel measurements
AC/DC coil and motor current measurements
Up to 6 channels for static and dynamic contact resistance
measurement of 100A rating each.
Mounted in a trolley with wheels for easy movement in
rough switchyard terrain.
MCBOA Puls software for pre-configuring test parameters
and sequences.

MCBOA Plus
Circuit Breaker Operational Analyzer

MCBOA Plus is a NextGen operational analyser that performs contact Coil & motor current analysis
travel, contact timing, coil and motor current, and static and dynamic MCBOA Plus records the current signature curves of the coils and
contact resistance measurements in live switchyard conditions. The motors during the breaker operation. Deviations from the
analyser is mounted in a specially designed trolley that allows it to be expected signature curves show possible electrical or
moved easily in the rough switchyard terrain. The analyser is supplied mechanical defects of the trip and close coils and incorrect
with MCBOA Plus PC software that allows pre-configuration of test coordination of the auxiliary contacts and release latches. The
parameters and test sequences that save you vital time in the analysis of motor currents shows the in-rush current, average
switchyard, thus minimising downtime. The software displays results current, and spring charging time. Spring charging time analysis
along with graphs and generates test reports. help in determining the condition of the spring mechanism.
Tests Performed
Static contact resistance test (CRM test)
Timing tests
MCBOA Plus tests the contact resistance of the closed
MCBOA Plus assesses the main contact and auxiliary contact timings.
switchgear to ensure that the load current flows with low losses.
This assessment is useful for measuring the contact bounces and non-
Sufficiently high contact resistance can cause substantial
simultaneity of contacts and helps in finding possible electrical or
heating and subsequent failure of the breaker contacts.
mechanical defects. It is possible to detect incorrect mechanical
adjustments and wear phenomena of the breaker by measuring the
differences between the fastest and slowest phases. Dynamic contact resistance test (DCRM test)
MCBOA Plus performs dynamic contact resistance measurement
Contact travel analysis (DCRM) analysis on the switchgear to measure the wear of the
MCBOA Plus makes use of special transducers to record the travel arcing contacts of SF6 MV, HV, and EHV breakers. Dynamic
signature curve of main contacts/rotating shafts during the breaker contact resistance measurement is important for assessing the
operation. Travel measurements assess the rate of displacement of contact condition after several fault trips on-site for finding out
the contact assembly. This assessment helps in understanding erosions, pitting, sluggishness, residual arcing tip length, etc.
whether the breaker contact operating mechanism is working without opening the interrupter. This cannot be detected by
appropriately. Deviations from the expected signature help finding performing static contact resistance measurements. The
possible mechanical defects of the main contacts, moving shafts, and measurement also helps to record the benchmark signature of
springs. The travel measurements also include measurement of the arcing contacts, which is used for studying the deterioration
velocity, insertion, contact gap, over-travel, and rebound. of arcing contact conditions over time.
Protection Testing - MCBOA Plus 67

Modules
CPU & Power Module Auxiliary Contact Modules
The CPU & Power Module communicates with a PC through either The Auxiliary Contact Module measures the status of the auxiliary
WiFi or Ethernet and controls the activity of all the remaining contacts, bounce, etc. A small current is injected through each
modules. In response to instructions given by the user, the PC sends channel using the common terminal which is sensed back and the
the data containing the command, sampling frequency, current status of the external contact to which the channel is wired is
range, travel settings, etc. that is required to control the remaining interpreted. Depending on the status of the contact, the module
modules. Once the command and other settings are transferred from provides digital data to the bus on the interface module. Each
the PC to this module, the data sampling process begins, and the timing channel is optically isolated from the other. The same
sampled data from each module are stored in the memory of the CPU module measures the Auxiliary contact timings of wet and dry
& Power Module. When the sampling operation is completed, the auxiliary contacts. Two Auxiliary Contact Modules are present in
collected data is sent to the PC for further evaluation. the default configuration of the system, each having four auxiliary
contact channels.

Travel Modules
The Travel Modules measure travel, contact speed, etc. Each
module has three isolated ADC channels running at 40 kHz and
with a 16-bit resolution. The module has programmable gains and
offsets to provide maximum amplification and conditioning to the
received signal. Additionally, it also has a built-in 5 V DC source for
exciting the transducers.

Motor Current Module


The Motor Current Module is an optional module that measures the
motor current and spring charging time. Each module has three
isolated ADC channels running at 1 kHz and with a 16-bit resolution.
The card has programmable gains and offsets to provide maximum
amplification and conditioning to the received signal. The module
Figure 1 : MCBOA Plus Modules measures motor current up to 30 A AC/DC. The same module
measures up to three channels of DC or 1-phase AC current or a

Command Modules single channel of 3-phase AC current. Multiple modules can be


added for increasing the channel count.
The Command Modules consist of two channels of fast SSRs ('NO')
rated at 35 A, 300V AC/DC that is used for issuing Close and Trip
Analog Input Module (0-10 V DC)
commands to the circuit breaker coils and controlling the motor
The 0-10 V DC Analog Input Module is an optional special purpose
command and its duration, based on the selections made in the
module that measures any signal or sensor that has a voltage
software. The module has an over-current sensing logic, which trips
output in the range of 0 to 10 V DC. The module has programmable
the module if the coil current exceeds 30 A. Additionally, each
gains and offsets to provide maximum amplification and
channel has a special circuit that is used to detect the instance when
conditioning to the received signal. The module is, typically, used
current begins to flow through the breaker coil and generate a trigger
for reading the laser or encoder-type sensor outputs. Multiple
impulse to start data acquisition at the selected sampling speed. The
modules can be added for increasing the channel count.
SSR module also measures the current flowing through the breaker
coil (up to 25 A AC/DC) and sends the measured value to the CPU &
Analog Input Module (4-20 mA)
Power Module. Three Command Modules are present in the default
The 4-20 mA Analog Input Module is an optional special purpose
configuration of the system, each having one close and on-trip
module that measures any signal or sensor that has a current
channel.
output in the range of 4 to 20 mA. The module has programmable
Main Contact Modules gains and offsets to provide maximum amplification and
The Main Contact Module measures the status of the main and PIR conditioning to the received signal. The module is, typically, used
contacts, bounce, etc. A small current is injected through each for reading the gas or oil pressure sensor outputs. Multiple modules
channel using the common terminal which is sensed back and the can be added for increasing the channel count.
status of the external contact to which the channel is wired is Analog Input Module (10-300 V DC)
interpreted. The measurement duration of this module is 0.02 ms to 2
The 10-300 V DC Analog Input Module is an optional special
s @ 40 kHz. Depending on the status of the contact, the module
purpose module that measures any signal or sensor that has a
provides digital data to the bus on the interface module. Each timing
voltage output in the range of 10 to 300 V DC . The module has
channel is optically isolated from the other. The same module
programmable gains and offsets to provide maximum
measures the Main and PIR contact timings. Two Main Contact
amplification and conditioning to the received signal. The module
Modules are present in the default configuration of the system, each
is, typically, used for reading the coil voltage outputs. Multiple
having two R, Y, and B channels.
modules can be added for increasing the channel count.
Protection Testing - MCBOA Plus 68

PIR Value Module MDCRM Plus Modules


The PIR Value Module is an optional module that measures the PIR The MDCRM Plus Modules are optional modules for measuring the
contact resistance value of the breaker contact. The module has static and dynamic contact resistance of the breaker contacts. Each
programmable gains and offsets to provide maximum amplification module has an option of either one or two contact resistance
and conditioning to the received signal. The module has a channels. They have a fixed 100 A current source and and high-
measurement range of 0-5 kΩ Multiple modules can be added for speed data acquisition hardware for continuous V and I
increasing the channel count. measurement. The modules have selectable resistance ranges of
200 μΩ, 2000 μΩ, 4000 μΩ, and 8000 μΩ. The modules
communicate with the CPU & Power Module over a robust wireless
DCRM platform. All the measurements performed by the MDCRM Plus are
communicated wirelessly back to the CPU & Power Module located
The dynamic contact resistance measurement (DCRM) is an
at a safe distance away from the breaker. The Modules have their
effective technique for monitoring the condition of the main and
own processing unit with a built-in battery and operate
arcing contacts of the circuit breaker without opening the
independently as per the commands issued by the user through the
interrupter. During DCRM, a C-O operation is performed on the
software.
breaker and the change in resistance during the entire operation is
calculated. This is achieved by injection of a constant current
through the contacts during the entire operation and continuous
measurement of the millivolt drop across the contacts while they
are in motion using 4-wire measurement.The change in resistance
thus calculated when plotted against time gives the DCRM
signature of the breaker. By periodically acquiring the DCRM
signature and comparing it with the original signature, the wear of
the breaker contacts and also deformations in the mechanism can
be estimated. The wipe of the arcing contacts can also be
estimated by simultaneously measuring the contact travel and
performing DCRM.

Figure 2 : MDCRM Plus Modules Docked for Charging

Visit our website


www.motwane.com
for more information
Protection Testing - MCBOA Plus 69

The MCBOA Plus is offered with 6 DCRM channel configurations. The MDCRM Plus Pole Unit is compact, lightweight, and can be
The MCBOA Plus performs DCRM by using the MDCRM Plus Pole easily carried by the technician while making connections to the
Unit accessory. The MDCRM Plus Pole Unit consists of an integrated breaker contacts. As it is directly mounted close to the breaker
current source and high-speed data acquisition hardware for contacts, the length of the test leads set is considerably shortened
continuous V and I measurement. It communicates with the allowing for a lightweight test leads set.
MCBOA Plus trolley over a robust wireless platform. All the
The MDCRM Plus Pole Unit runs on a LiPo battery. The LiPo battery
measurements performed by the MDCRM Plus Pole Unit are
is capable of delivering multiple shots in a single charge. At the end
communicated wirelessly back to the MCBOA Plus trolley located
of testing, the MDCRM Plus Pole Unit is simply placed back into the
at a safe distance away from the breaker. The acquired data are
MCBOA Plus trolley and can be charged through the trolley itself,
converted into a suitable format and displayed in the MCBOA Plus
eliminating the need for external chargers. Various protections
software.
from over charging and deep discharge have been implemented
for ensuring battery safety and a long battery life.

Transducers
MCBOA Plus is supplied along with custom-designed fixtures suitable for all types of circuit breakers manufactured by ABB, CG, L&T,
Schneider, Siemens, Toshiba, and all others. Our test fixture can be customised for mounting circuit breakers of any design.

The transducer is used for measuring the contact travel and all other breaker parameters that are derived from travel measurements, such as
contact speed or velocity, contact gap, snatch gap, wipe gap, bounces, bounce duration, rebound, rebound duration, over-travel, and over
travel duration. In the case of linear travel, the travel is measured in millimeters. However, in the case of rotary or angular travel, the travel is
measured in degrees.

For linear travel measurements, either a resistive or a more accurate laser transducer is used. While, for rotary travel measurements, either a
resistive transducer or an encoder is used.

Measurements

Contact travel (linear / angular)

Contact gap / Wipe gap

Snatch gap

Over travel

Rebound

Over travel duration

Rebound duration

Velocity / Contact speed

Figure 5: Linear Travel Transducer with Fixture

Transducer Types

Linear resistive

Rotary resistive

Rotary encoder

Linear laser
Protection Testing - MCBOA Plus 70

MCBOA Plus Software Features

Figure 4: MCBOA Plus Software Test Panel

Modern and easy-to-use user interface with Windows 10 styling. Printing of results in a graphical format with test header and
calculation footer, on the external printer.
Multiple themes are available as per the user's preference.
Comparison of graphs of multiple operations for
Easy to access command buttons for performing regular tasks.
performance evaluation over some time.

Built-in access rights management with password protection for


Zoom, Pan, and Cursors along with facility for enabling and
restricting access to certain features according to a user type
disabling channels for in-depth analysis of graphs.
(Operator/Supervisor/Administrator).
Test certificate generation.
Pre-programming of test parameters, limits, and sequences that
saves valuable time on-site and reduces downtime due to All test data (settings and results) are stored in a database
maintenance. for archival and analysis.

Test results displayed graphically and also in a numerical tabular


form along with pass/fail results for individual parameters.
Protection Testing - MCBOA Plus 71

Technical Details MCBOA Plus

Channels Configuration Range Resolution Accuracy

24: 4 Main + 4 Measurement 1mS @ 1kC Value +0.05%


Contact
PIR per pole, 3 poles duration 0.02mS to 2S
Timing
simultaneously @ 40kC 0.02mS @ 40kC

Auxiliary 8: User 10 to 300V DC 1mS @ 1kC Value + 0.05%

Contacts configurable

6: Trip / Close Up to 25 A AC/DC, 10mA Value + 1%


Coil Current
Coil current Auto-ranging

6: Travel 10micrometer Value + 0.5%


0-5 V DC
Travel
characteristics

Six solid state contacts rated at 35Amp/ 300V AC/DC for breaker operation
Breaker Control
(User configurable Close/Trip commands)

Trigger Options Open, Close, C-O, O-C, O-C-O, OCO-CO and Motor (delay between operations selectable)

Sampling Speed 40kC, 20kC, 10kC, 5kC, 2kC & 1kC selectable

Plot Length 2Sec at 40kC, 5Sec at 20kC, 10Sec at 10kC, 20Sec at 5kC, 40Sec at 2kC and 100Sec at 1kC

Test Results Result with test header and computation footer

Graphical Results Test graph with detailed analysis of results over graph

Control Through External Laptop

Communication Ethernet port and Wi-Fi for communication between laptop and instrument

Printer External printer through laptop-based software

Environment 0 to 50 degrees C, 95% RH (non-condensing), electrical noise normally found in charged HV switchyards

Power 230 Volts ±15 %, 50 Hz ±10 %, 360VA (Appx)

Size 1092 mm x 485 mm x 560 mm

Weight 55 Kg. Approx

Channel Details
Main Contact Timing 12

PIR Contact Timing 12

Auxiliary Timing 12

Travel 6

Coil Current (Close & Trip) 6

Breaker Control 6
Protection Testing - MCBOA Plus 72

Technical Details MCBOA Plus

Standard Accessories
Item* Length Item* Length

Main Contact Timing Cable 10 m Spare Fuses 1 Set

Auxiliary Contact Timing Cable 10 m Soft Carrying Case for Test Leads 1 No.

Travel Cables 10 m MCBOA Plus Software on a CD 1 No.

Breaker Control Cable 10 m User Manual 1 No.

Master Earthing Cable 10 m Ethernet Cable 1.5m 1 No.

Mains Cord 3m

Optional Accessories
Channels Configuration Range Resolution Accuracy

1000, 2000, 0.1 μΩ Value + 1%


DCRM Each for Resistance & test current
4000, 8000
(6 channels) as per configuration ordered
Micro Ω

DCRM + CRM Each for Resistance & test current 1000, 2000, 0.1 μΩ Value + 1%
4000, 8000
(6 channels) as per configuration ordered
Micro Ω

Configurable
Analog Inputs Optional for conditioned 10-300 V DC 10mV Value + 1%
300 V DC analog signal input
(6 channels)
Configurable
Analog Inputs Optional for conditioned 0-10 V DC 1mV Value + 0.5%
10 V DC analog signal input
(6 channels)
Configurable
Analog Inputs Optional for conditioned 4-20 mA 0.1mA Value + 0.5%
20 mA analog signal input
(6 channels)

Optional PIR
Optional for pre insertion 0-5 k Ω 1Ω Value + 0.5%
Value
resistor value measurement
(6 channels)

Motor Current 3: DC Motor Current/ 1 Phase Up to 30 A 10mA Value + 1%


AC/DC,
AC Motor Current; 1 : 3 Phase
Auto-ranging
AC Motor Current

Item Quantity

Transducers and Fixtures 1 Set

Branded Laptop with Windows 10 1 No.


Protection Testing - MCBO-A 73

Features
Connects to Circuit Breakers, Drives, and Earth Switch with
wear resistant test leads, having suitable connectors.
Selects pre-programmed setup parameters and pass / fail
limits through software.
Prints graphical results with user specified header and footer
on external printer.
Windows based MCBOA software allows configuring &
storing test setups, viewing reports, and analyzing and
handling graphical test data using a PC.
Automatic creation of folder structure on PC for storage of
test data.
Dynamic calculations with cursor movements for on-screen
analysis.
Test Certificate can be stored and printed as per the
manufacturer's format which enables user to compare with
factory test results.
All test data is stored in a database for archival and analysis.

MCBOA
Circuit Breaker Operational Analyser

MCBOA is an easy-to-carry test instrument which has basic Applications


functionality and features required for testing all types of Switchgear
Circuit Breaker Testing (AIS, VCB) Gas Insulated
present in GIS chambers like, Circuit Breakers, Drives, Earth Switches,
Switchgear Testing Drive Switch/Earth Switch Testing
etc. MCBOA is a software-based economical instrument which is
Isolator /Disconnect or Testing
useful for shop floor testing and onsite commissioning.
Analysis of test results provides information which is useful for
evaluating and rectifying settings for motor currents, contact timings, Measurements
closing and opening speeds, over-travel, rebound, and contact wipe, Main Contact Timing
etc. The operations that can be performed by this system are Close, PIR Contact Timing
Open (for switch, drive & circuit breaker) CO, OC, OCO, and other Number of Bounces
complex recloser sequence (for circuit breakers only). Bounce Duration
Contact Mismatch
Protection Testing - MCBO-A 74

Technical Details MCBOA

Specifications

Input Supply 230V AC, ±5%, 50Hz, Single Phase

Dimensions 428mm X 350mm X 230mm

Weight 7.5 Kg Approx.

HS Code 90318000

Contact Timing Module Isolated channels for timings of 6 Main and 6 Dry Auxiliary contacts

Channels 12 channels

Resolution 0.1 ms at 10kC sampling speed

Accuracy Value ±0.05% ± Resolution

Analog Input Module

Channels 6 channels

Resolution 0.025% of full range

Accuracy ±1% ± Resolution

Isolation 2kV between two channels and between channels and chassis

SSR Output Module

Channels 2 channels, One each for Close and Trip commands.

Solid State Relay contacts rated at 30A / 250V AC / DC for issuing commands to the breaker.

Protection Inbuilt over-current protection

Switching Within 50 µs

Analog Channel Details :

2 channels for Closing / Tripping coil currents.

Current range: Up to 25A max.

3 channels for Closing / Tripping speed and mechanism travel of each pole.

Excitation source for transducer: 5 VDC, inbuilt

1 channel for spring charging Motor Current - DC or 1-phase AC or 3-phase AC

Current Range: Fixed at 20 A max.

Drive and earth switch & High-speed earth switch


Testing and analysis of various drives used for GIS bay

Contact / Mechanism Speed for high-speed earth switch

Motor starting current

Continuous Motor current

Trip and Close timings


Protection Testing - MCBO-A 75

Technical Details MCBOA

Breaker
Contact Timings

Contact Bounce

Non-simultaneity of contacts

Contact / Mechanism Travel and Speed characteristics

Trip & Close coil current characteristics

Motor current

Accessories
Standard

Contact Timing Cable, 15m 3 Nos

Breaker Control Cable, 7m 1 Nos

Master Earthing Cable 7m 1 Nos

Mains cord, 3m 1 Nos

Spare Fuses 1 Set

Soft Carrying Case For Test Leads 1 Nos

Operation cum Instruction Manual 1 Set

Optional

PC Downloading & Analysis Software on CD 1No

Note: 1) The above MCBOA channels are part of basic model and can be customized as per specific requirements. 2) Size and weight of the instrument will vary depending on
channel requirement.
Protection Testing - MCBO-A 76

Features
100 A DC current injection through battery with inbuilt
charger
Recording of DCRM signature of contact by four-wire
the method which ensures high accuracy & repeatability
Quick performance check of the circuit breaker by taking
a C-O operation on the breaker with time resolution in
micro-seconds and selectable delay between multiple
operations
Supplied with test lead set suitable for EHV circuit
breakers having quick-fit connectors
Housed in a robust carrying case that can be connected
to an existing MCBOA series of circuit breaker test
systems.

MDCRM
Portable Dynamic Contact Resistance Meter Measurements
Quick performance check of the circuit breaker by
MDCRM is used to measure the dynamic contact resistance and plot a measuring the dynamic behavior of contacts.
dynamic contact resistance curve (DCRM signature) against time, Correlation of DCRM with travel characteristic using
which helps to monitor the condition of the contacts without opening customized travel transducers and fixtures
the interrupter. A test current of 100A DC is injected into the contact Recording of DCRM signature of a single interrupter at a
and the dynamic value of the circuit breaker contact resistance is
time
measured when the Breaker is performing a C-O operation. MDCRM is
Independent, isolated, inbuilt 100 A DC source for single
used essentially to test the MV and EHV Circuit Breakers with
interrupter.
insertion type of contacts.
When DCRM signature is correlated with travel curve, the
health of main and arcing contacts can be ascertained,
and wear and tear of arcing contacts can be estimated
Health of the damping mechanism is also monitored
Protection Testing - MCBO-A 77

Technical Details MDCRM

Software Features
Easy-to-use, high-level graphical user interface and programmable test plans help to create a test setup library

Dynamic calculations with cursor movement to help in the on-screen analysis

Automatic creation of folder structure for storage of test data

Upgrade for existing Windows-based MCBOA test software of earlier versions, to allow an analysis of DCRM signatures

Specifications
Resistance range 8000μ , 4000μ , 2000μ full-scale

Resolution 32, 16, 8 micro ohm

Accuracy Value + 2 % + Resolution

Current 100 A DC full-scale, for up to 1 sec

Output 0 to 5 V DC

Software MDCRM software for on screen analysis of test results

Power 230 V AC + 5%, 50 Hz + 10%

Dimensions 430mm X 435mm X 188 mm

Weight 10 Kg Approx.

HS Code 90318000

Test leads set for


Connection between MDCRM to Breaker / GIS – 15 meter

Connection between MDCRM to MCBOA - 5 meter

Accessories
Standard

Contact Timing Cable, 15m 3 Nos

Breaker Control Cable, 7m 1 Nos

Master Earthing Cable 7m 1 Nos

Mains cord, 3m 1 Nos

Spare Fuses 1 Set

Soft Carrying Case For Test Leads 1 Nos

Operation cum Instruction Manual 1 Set

Optional

PC Downloading & Analysis Software on CD 1No


Protection Testing - MGFL 78

Features
Locates & pinpoints DC Ground fault in
Online/Offline condition.
Incorporates Automatic Capacitive Balancing & is
fully automatic.
Highly immune to noise in the system.
Extremely high sensitive to Fault Signal.
Light weight and user friendly.
Bluetooth Enabled
Lightest Weight in Industry
Rechargeable Battery operated.
L, M & H mode for Different types of fault location.

Connected to Cloud

MGFL
DC Ground Fault Locator

Applications
Battery systems used in protection devices are designed
Floating DC systems are the back bone of any substation. and operated as a floating from ground system which
Malfunctioning of DC system / non-availability of sound DC system means that there is no intentional connection to ground
can lead to very big catastrophe in the substation and hence it is a from either the positive polarity or negative polarity of the
necessity that the floating DC systems in the substation should be free DC system. Sometimes, a very low resistance or solid path is
from any faults. established from one of the polarity of DC system to ground
which can lead to significant voltage drop, & continuously
The DC Ground Locator MGFL helps substation engineers in locating, draining of battery bank. The usual suspects for DC ground
tracing, pinpointing DC ground faults in any floating DC system up to faults include worn insulation, conductive dust, water, or
300V DC in Online and Offline condition. The MGFL is a portable light other "soft grounds." Ground faults account for more than
weight instrument used to locate ground fault in DC systems. It 85% of equipment short circuits and in 95% of those cases it
consists of a Transmitter Unit and Receiver Unit. The transmitter is is caused by insulation deterioration on wires and cables.
connected to live / non-live floating system up to 300V DC preferably These DC earth faults need to be rectified in time to avoid
on the DC bus. It then transmits low frequency and low voltage signal unscheduled breakdown.
in the DC system without affecting the sensitive operation of relays.
Major Application
The transmitted signal is then tracked by receiver to locate the fault
feeder and to track it further up to the point of fault. The instrument Utility - DC system with faulty grounding
balance the capacitance of DC system automatically and is fully Railway - Signal, communication and locomotive electric
automatic to detect any faults. The instrument incorporates advanced equipment.
signal processing to eliminate noise in the DC system and is very
Industrial Facilities - Electric safety equipment for general
sensitive to any ground faults. The instrument is fully automatic and
power distribution applications.
detect earth faults / mixing of source at ease.
Telecommunication etc.
Protection Testing - MGFL 79

Accessories
Technical Details MGFL
Standard

Receiver unit
Transmitter unit
Test lead Set with crocodile clips Clamp 25 mm
Power
Clamp 20 mm
Transmitter Spare battery - 9V
Rechargeable Li-ion Batteries Charged By 5v Charger Charger 9V - Receiver unit
Charger 5V - Transmitter unit
Receiver
Instruction Manual
Rechargeable Site Replaceable Li-ion Batteries Charged By 9V Charger

Signal Voltage

< 15 V RMS variable

Short Citcuit Current

< 2mA SIGNAL

Frequency

< 12Hz selectable

Fault Resistance

1 MΩ 400 kΩ, 100 k Ω, 60 k Ω variants

Sensor Probe

High Sense Big Probe - 50mm

High Sense Small Probe - 20 Mm

Control Fully Automatic

Capacitive Balancing Automatic

Temperature
Storage 00C to 550C

Operating 00C to 550C

Dimensions in MM

Transmitter 120 mm(H) x170 mm(W) x 55 mm(L)

Receiver 95 mm(H) x175 mm(W) x40 mm(L)

Weight

Transmitter 0.5 kg

Receiver 0.2 kg

Note : Specification & design subject to change without prior notice


Protection Testing - MGFL 80

This Product is Connected (MOT-WARE Enabled)

MOT-WARE Cloud Application

Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.

MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.

Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.

Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.

Important Benefits

Accurate Digital Centralized Customizable Report Alerts &


Data Data Access Templates Notifications

Trend Analysis Minimum Training Scheduling Tests

Reach out to us at setup@motware.com to setup a new MOT-WARE account.


Protection Testing - MLCM 81

Features
Simultaneous display of fundamental & 3 Harmonic
Leakage Current and Resistive 3 Harmonic Leakage Current.
Highly immune to noise in the system
Data Transfer to your smart phone
Android Application to trend monitor your LA
Export report to excel/graphical pdf format directly from
the App.
User-friendly, rugged and very light weight.

MLCM
Leakage Current Monitoring Applications
Lightning arrester is connected between high voltage
CAT III IP terminals and ground terminals for the protection of the
equipment at the substations against travelling waves i.e., in
600V 54
parallel with the equipment to be protected at the
substation. In other words, when a lightning surge (or
The MLCM is a light weight, cost effective, portable and comes handy
switching surge) travels along the power line to the arrester,
to monitor the healthiness of lightning arrester. MLCM measures the
the current from the surge is diverted through the arrester,
fundamental and third harmonic leakage current down to micro
in most cases to earth without affecting the continuity of
ampere. This makes it easy for maintenance engineer to check and
supply.
monitor in-service lightning arresters periodically and determine their
healthiness. As and when the LA deteriorate, the third harmonic Lightning arresters at substations are exposed to a variety
leakage current also increases which provides a clear indication for of stress factors originating both from the network and from
maintenance engineer to take immediate action. their service environment. These stressors can then cause
premature ageing or even damage to their varistor blocks.
The main types of such degradation can be classified as
either:

Degradation of insulation properties


Degradation of protective characteristics

Even though they are not very costly device, their


maintenance is very critical of the view that they protect
substation's essential assets. It is a necessity that these LA's
are periodically monitored to ensure all essential assets are
protected. There are various methods as per IEC 60099-5 to
monitor the LA's. Out of which, it is very simple and easier to
monitor the in-service lightning arrester without
dismantling it by measuring the 3 harmonic leakage current
using B1 and B2 methods.

Main Application

Used to check healthiness of lightning arresters


Used to measure leakage currents.
Protection Testing - MLCM 82

Accessories
Technical Details MLCM
Standard

1 No. Leakage Current Monitor unit MLCM


1 No. 20mm/40mm/68mm High sense Current Probe.
1 set hook stick, base plate, cables for B2 method.
Power
1 No. Smart Phone (Optional).
Transmitter 1 No. Android App
Rechargeable Li-ion Batteries charged By 9V Charger 1 No. Charger for MLCM
2 No. Battery for MLCM
1 No. USB cables and Smart Phone Charger.
Range 1 No. Operating and Instruction Manual
1µA to 30mA total and 3rd harmonic resistive current (B1 Variant),

1µA TO 30 mA - resistive current after compensation of capacitive current,

Temperature and voltage coefficients (B2 Variant).

Continuous update of display and app every second without delay in processing.

Accuracy

+/- 5 % , +/- 5 least counts

Variant's
IEC 60099-5 B1, B1& B2.

Software
Android app to download test data and to monitor the trend of LA's.

Clamp Diameter 20mm / 40mm / 68mm

Correction Factor
Temperature and voltage correction for B1 and B2 variant. System 3rd harmonic

compensation as per B2.

Calibration Inbuilt calibration of both B1 & B2

Temperature

Storage -20 to 700C

Operating -10 to 500C

Dimensions 95mm (H) x 175mm (W) x 40mm (L)

Weight

MLCM Unit less than 2kg

Note : Specification & design subject to change without prior notice.


Protection Testing - MLCM-B2 83

Features
Simultaneous display of fundamental & 3 Harmonic
Leakage Current and Resistive 3 Harmonic Leakage Current.
Highly immune to noise in the system
Data Transfer to your smart phone
Android Application to trend monitor your LA
MLCM
Export report to excel/graphical pdf format directly from
the App.
User-friendly, rugged and very light weight.

MLCM-B2
Leakage Current Monitor

CAT III IP Applications


600V 54 Lightning arresters protect your valuable assets from
transients and lightning strikes. Even though they are not
very costly device, their maintenance is very critical of the
The MLCM - B2 is light weight, cost effective, portable and comes
view that they protect your costly assets. It is a necessity
handy to monitor the healthiness of LA’s. The Lightning arrester
that these LA's are periodically monitored to ensure all the
monitor MLCM - B2 measures the fundamental and third harmonic
costly assets are protected always. There are many
leakage current, resistive current as per IEC 60099-5-B1 and IEC
methods as per IEC 60099-5 to monitor the LA's. Out of
60099-5-B2. This makes it easy for maintenance crew to check and
which, it is very simple and easier to monitor the in-service
monitor in-service Lightning arresters in a periodic manner and
Lightning arrester without dismantling it by measuring as
ascertain their healthiness. As and when the LA's deteriorate, the third
per IEC 60099-5-B1 and IEC 60099-5-B2. The instrument
harmonic resistive leakage current also increases which provides a
incorporates both the methods as per IEC.
clear indication for maintenance crew to take immediate action and to
take further action on the same. Used To Check Healthiness of Lightning Arresters.
Protection Testing - MLCM-B2 84

Accessories
Technical Details MLCM-B2
Standard

1 No. Leakage current monitor unit MLCM


1 No. 50 mm High sense current probe.
1 set hook stick, base plate, cables for B2 variants.
Power
1 No. Smart phone with inbuilt printer.
Rechargeable Li-ion Batteries 1 No. MLCM app - software
1 No. Charger for MLCM
1 No. USB cables and Smart phone charger.
Measure
1 No. Operating and instruction manual.
Simultaneous display of 50Hz leakage current, 3 harmonic leakage current and

3 rd harmonic resistive current as per IEC60099-5-B1 and B2.

Range 1uA to 20mA

B1 Method MLCM - B2
Total 50 Hz + Total 3rd harmonic current, + B1 w/o system harmonic compensation

B2 Method

All results of B1 + 3rd harmonic resistive current with system third harmonic

compensation

Both B1 & B2 are provided with rated voltage and temperature compensation

Accuracy +5%, + 5 least counts

Resolution 1 UA

Variant’s IEC 60099-5 B1, B2

Software

The instrument is provided with smart android device with inbuilt printer and

Android app to download test data and to monitor the trend of LA's. The user

can view results graphically, generate pdf reports, share results with colleagues

and seniors and take proper decisions.

Lamp Diameter 50mm.

Temperature Storage: -10 to 550C, Operating: -10 to 550C.

Dimensions 220mm x 155mm x 80mm approx.

Weight ~1 kg approx.

Note : Specification & design subject to change without prior notice.


Protection Testing - HVT Series 85

Features
Variable Output Voltage AC/DC/AC+DC
Selectable Trip Current
Zero Start Interlock
Timer to set duration of test
Audio/Visual Indications
Overload Protection
High Leakage Current Range
Supply Fault / Earth Open Interlocking Door / Cabin
Door Interlock
Wheel mounted for easy transportation

Applications
Dielectrics (insulation) for electrical equipment and
apparatus is used for many different applications. It is
expressed for a wide range of environmental conditions
HVT Series such as temperature, moisture, chemicals, other
AC-DC Hi Pot Test Set contaminants, and exposure to weather. One major factor
affecting insulation life is thermal degradation, although
moisture, contamination, voltage stress, and other factors
The Motwane's Hi-Pot Tester, HVT series offers a wide range of test
may also contribute to its degradation. In addition, the life of
voltages to determine the withstand strength of electrical insulation
an insulating material depends on the degree of loading, the
for the normally occurring over voltage transients. HVT series sets
type of service to which the equipment is subjected, the
are available in a wide range of voltage and power ratings with
care it receives during installation and operation, and
exceptional reliability, durability and functionality which can
mechanical vibration and forces to which it is subjected.
generate AC, DC or AC+DC voltages (eliminates the need of two
separate kits). Available with manual / motorized controlled A dielectric withstand test is an electrical test performed on
operation provides variable output voltage. Test sets had selectable a component or product to determine the strength of
tripping current to identify breakdown voltage of different test insulation. Voltage applied between equally insulated
objects and also have timer, useful to set duration of test period. HVT sections of a part or energized parts and electrical ground
series is provided with HV indication, supply fault / earth open under test and determining the leakage current that may
interlocking & door / cabin interlocking & overload protection flow under test conditions. Excessive leakage current flows
provided for safety of operator & test set. may indicate a deteriorated condition or impending failure
of the insulation. Insulation testing can be performed by
applying either direct current (DC) voltage or alternating
current (AC) voltage The test to qualify a device's ability to
operate safely during rated electrical conditions. If the
current through a device under test is less than the specified
limit at the required test potential and time duration, the
device meets the dielectric withstand requirement. A
dielectric withstand test may be done as a factory test on
new equipment, or may be done on apparatus already in
service as a routine maintenance test.

Typically used for


Transformer/Motor/ Generator/Switchgear testing
Insulated Electric Apparatus & Components
Power Cables.
Aerial Lift Equipment/Bucket Trucks
Domestic appliance testing
Capacitor Coils & chokes
Protection Testing - HVT Series 86

Technical Details HVT Series

Technical Specification

MOT- MOT- MOT- MOT- MOT- MOT- MOT- MOT-


Model
HVT5 HVT10 HVT15 HVT20 HVT30 HVT40 HVT50 HVT70

Output Voltage 5KV 10KV 15KV 20KV 30KV 40KV 50KV 70KV

Tripping Current Options 1) 50mA or 2) 100mA, Selectable at (25%-50%-100%) of full range

Burden at 50mA 0.25KVA 0.5KVA 0.75KVA 1KVA 1.5KVA 2KVA 2.5KVA 3.5KVA

Burden at 100mA 0.5KVA 1KVA 1.5KVA 2KVA 3KVA 4KVA 5KVA 7KVA

Type of Voltage AC/DC/AC+DC

Display (V/I/T) Digital Meter

Voltage Meter 0.-5KV 0.-10KV 0-15KV 0-20KV 0-30KV 0-40KV 0-50KV 0-70KV

Voltage Accuracy +2% of full scale reading +2 digits

Voltage Resolution 0.1KV

Current Accuracy +2% of full scale reading +2 digits

Mains Supply 230 V +10%, 1 Phase AC, 50/60 Hz

Duty Cycle 15 min On, 10min Off

Timer 0-999 seconds Digital Timer

Time Accuracy +0.05% of full scale reading

Operation Mode Manual Motorized

Colling Type Air cooled

Indication Bright LED for Power ON & Test ON

Protected by MCB,
Protection and
Fuse Zero Start Interlock
Safety
Earth Open/ Supply Fault Interlock, Door/ Cabin Interlock

Operating
0-55°C, 5-90% RH Non Condensing
Temperature

*We also provide customized High voltage test set as per requirement

Ordering Information

Model Products Detail Accessories


MOT-HVT5 5KV High Voltage Tester Standard

MOT-HVT10 10KV High Voltage Tester Grounding Cable


Instruction Manual
MOT-HVT15 15KV High Voltage Tester
Warranty Certificate
MOT-HVT20 20KV High Voltage Tester Calibration Certificate
MOT-HVT30 30KV High Voltage Tester Non shielded HV Cable
Spare Fuse
MOT-HVT40 40KV High Voltage Tester
Optional
MOT-HVT50 50KV High Voltage Tester
Interconnecting Cable
MOT-HVT70 70KV High Voltage Tester Discharge Rod
Note: while ordering need to mention 1) Type of voltage : AC, DC or AC-DC
2) Tripping Current : 50mA or 100mA

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes continuous improvement of its product. We, therefore,
reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - MOT-RTS 87

Features
Compact unit with rugged case
Variable model and selectable Output Current
up to 200A/600VA
Output Voltage 0-250V AC/DC
Auto Cut-Off upon Tripping Relay
Timer Range 0.0001-9999 Seconds Auto Ranging ,
Digital Timer with Accuracy +0.05% + 2 Counts
Wheel mounted for easy transportation

MOT - RTS
Relay Test Set

The Motwane's RTS Series also known as kit is a portable, cost Applications
effective is portable cost effective solution to test voltage & current
The secondary current injection test of solid-state units
based relays. It is designed with highly accurate digital meters for
can be performed by a specially designed power supply
testing of protective devices. The MOT-RTS set provides high burden
unit. Secondary injection tests are always done prior to
to test electromechanical relays. RTS Series can provide up to 200A
primary injection tests. The purpose of secondary injection
for CT, MCB Testing. The compact & rugged design makes it easy to
testing is to prove the correct operation of the protection
move in relay room.
scheme that is downstream from the inputs to the
protection relay(s). This is because the risks during initial
testing to the LV side of the equipment under test are
minimized. It should be noted that the secondary current
injection method only tests the solid-state trip unit logic
and components like relay, miniature breaker etc.

Over Current Relay


Undercurrent Relays
Over voltage Relays
Under Voltage Relays
Thermal Relays
Earth Fault Relays
Electromechanical Relays
Miniature Circuit breaker etc.
Protection Testing - MOT-RTS 88

Technical Details MOT - RTS

Technical Specification

MOT- MOT- MOT- MOT- MOT-


Model
SIK10 SIK20 SIK50 SIK100 SIK200

Output Current 0-10A 0-20A 0-50A 0-100A 0-200A

Selectable Current
0-1-5-10-25-
Ranges (O/P current 0-1-5-10A 0-1-5-10-20A 0-1-5-10-25-50A 0-1-5-10-25-50-100A
display on % Ammeter)
50-100-200A

Burden 200VA 400VA 600VA

O/P DC Voltage 0-250V DC

O/P AC Voltage 0-250V AC

Voltage Accuracy +1.5% of full scale reading +2 digits

Voltage resolution 1V

Current Accuracy + 1.5% of full scale reading + 2 digits

Current Resolution 1% of full scale

Timer Range 0.0001-9999 Seconds Auto Ranging ,Digital Timer

Timer Accuracy +0.05% +2 Counts

Duty Cycle 30 Min ON, 10 Min OFF

Mode of Operation Manual

Display LED Seven Segment Digital Display Meters

Indications Bright LED for Power ON & Test ON

Mains Supply 230 Vac +10%, 1 Phase, 50/60Hz

Protection and Safety Fast blow glass fuse Over current tripping

Operating Temperature 0-55°C, 5-90% RH Non Condensing

PVC insulated 2.5 sq. PVC insulated 10 sq. mm PVC insulated 16 sq. PVC insulated 25 sq. PVC insulated 50 sq.
Output Current leads mm cu cables 2X1.5mtr cu cable 2X1.5mtr lug mm cu cable 2X1.5mtr mm cu cable 2X1.5mtr mm cu cable 2X1.5mtr
lug at both ends at both ends lug at both ends lug at both ends lug at both ends

*We also provide Customized RTS as per requirements

Ordering Information
MOT-RTS10/200 10A Relay Test Set

MOT-RTS20/200 20A Relay Test Set

MOT-RTS50/400 50A Relay Test Set

MOT-RTS100/600 100A Relay Test Set

MOT-RTS200/600 200A Relay Test Set

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Protection Testing - MOT-RTS 89

Technical Details MOT - RTS

Accessories
Standard

Lead sets

PVC insulated output current lead set - 1set

PVC insulated 2.5 Sq.mm Cu cable 2 corex4 mtrs one

side banana plug & other side small crocodile clip - 1 no

PVC Insulated 1.5 Sq.mm Cu Cable 2 core x 4 mtrs one

side banana plug & other side small crocodile clip - 2 no

Mains Power Supply Cord

Instruction Manual

Short Link

Spare Fuse

Calibration Report

Warranty Certificate
Protection Testing - PIK Series 90

Features
Variable Output Current
High VA burden to test high impedance objects
Digital timer for measuring tripping time
Zero Start Interlock for safety
Auto Cut-Off upon Tripping Relay
Current range ( Low - 50% & High - 100% of full range )
CT sec current measurement (Optional)
CT Polarity Detection (Optional)
Wheel mounted for easy transportation

PIK Series Applications


Primary Current Injection Kit.
The primary current injection method is usually a preferred
method to verify the current sensors, wiring, and the current
The Motwane's Primary Current Injection kit MOT-PIK series is most conduction path in the breaker. In order to identify sensor
reliable & effective kit for testing & commissioning of protecting and wiring related problems, it is recommended that the
system in electrical substation. The PIK series offer high output primary current injection test is to be conducted separately
current up to 3000 Amps with relatively high burden up to 20kVA. It on each phase through current transformer that ensures
is designed with user friendly features to check operations of that the sensors and wiring of the breaker are working
protection component system including Current transformer, Circuit proper.
Breaker, Current Sensor and Relays The Motwane PIK with high VA
The primary current injection method is also useful for
burden makes it possible to deliver desired current to high impedance
testing current transformer ratio. The secondary current of
object like Current transformer. It has optional feature to measure CT
the transformer bears a known relationship with the primary
secondary current as well as polarity.
current. Any change in the primary current is reflected in the
secondary circuit. To verify the turns ratio and polarity tests
on CT, current injected on primary side of CT and measured
at secondary side of CT for relaying to ensure that they have
the correct turn's ratio and relaying accuracy.

High current injection (primary current) used is recom-


mended during commissioning of protection systems and
also recommended during major repairs and component
replacement in power substations.

Motwane's Primary Current Injection Kits are used to test


Current Transformers, Circuit Breakers, Bus Bars, Relays,
MCBs, MCCBs etc.

Optional Features

Measurement of CT sec current & Polarity


Auxiliary variable AC/DC voltage 0-250V
Measurement of Open Circuit Voltage of o/p
current terminals

Warranty: Standard one year warranty against any


manufacturing defects.
Protection Testing - PIK Series 91

Technical Details PIK Series

Technical Specification

MOT- MOT- MOT- MOT- MOT- MOT- MOT- MOT-


Model
PIK200 PIK500 PIK800 PIK1000 PIK1500 PIK2000 PIK2500 PIK3000

Output Current 0-200A 0-500A 0-800A 0-1000A 0-1500A 0-2000A 0-2500A 0-3000A

O/P Accuracy +1.5% of full scale reading + 2 digits

O/P Resolution 1A

Burden at 100mA 5V 6V 6.25V 5V 6.67V 7.5V 6V 6.67V

Burden 1KVA 3KVA 5KVA 5KVA 10KVA 15KVA 15KVA 20KVA

Timer 0.0001 to 9999 sec Auto ranging, Digital timer

Timer Accuracy +0.05% +2 counts

Mains Power Supply 230Vac +10 %, Single Phase, 50/60Hz

Operation Mode Manual Motorized

Duty Cycle 10 min On, 20 min Off

Display LED Seven Segment type Digital Display

Indication Bright LED for Test ON and Power ON operation

Protected by MCB & Fuse


Protection & Safety Zero Start Interlock
Over Current Tripping

Unit Combined control & loading unit Separate control & loading units

Operating Temperature 0-55°C, 5-90% RH Non Condensing

Standard 50 mm2 120 mm2 180 mm2 240 mm2 400 mm2 480 mm2 600 mm2 720 mm2
Output Cables (2X5) meters (2X5 ) meters (2X5 ) meters (2X5) meters (2X7) meters (2X10) meters (2X10) meters (2X10) meters

*We also Provide customized Primary Injection kit as per requirement

Ordering Information
MOT-PIK200/1 Primary Current Injection Kit : 200A with 1kVA Burden

MOT-PIK500/3 Primary Current Injection Kit : 500A with 3kVA Burden

MOT-PIK800/5 Primary Current Injection Kit : 800A with 5kVA Burden

MOT-PIK1000/5 Primary Current Injection Kit : 1000A with 5kVA Burden

MOT-PIK1500/10 Primary Current Injection Kit : 1500A with 10kVA Burden

MOT-PIK2000/15 Primary Current Injection Kit : 2000A with 15kVA Burden

MOT-PIK2500/15 Primary Current Injection Kit : 2000A with 15kVA Burden

MOT-PIK3000/20 Primary Current Injection Kit : 3000A with 20kVA Burden

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - PIK Series 92

Technical Details PIK Series

Accessories
Standard

Test Lead set : pair of cotton braided copper

Cables with lugs at both end

Mains Power Supply Cord

Spare Fuse

Short Link

Instruction Manual

Calibration Certificate

Warranty Certificate

Optional

C - clamp

Interconnecting cables
High Voltage Detectors 93

Features
Colour Code models for different voltage levels.
Non-contact / Contact type Detectors.
Indicates presence of High Voltage by Audio
Annunciations as well as Visual Indications.
Bright high intensity red LED's provide clear visual
Bullet even in unfavourable daylight conditions.
A Buzzer produces a loud beep which is audible even in
noisy backgrounds.
Supplied as a complete kit with HV Detector, Telescopic
Fibre Glass Insulation stick and ergonomically designed
sturdy carry bag.
Self test button to test battery and proper functioning
of HV detector.
Powered by a single 9V battery type (6F22), easily
replaceable on field.
Type tested at CPRI/ERDA
Available in FRP Telescopic Rod / FRP Sectional Hot Stick
Rod in 1.2 / 3 / 5 mtr.

Note : Complies IS 2071 (Part-I) and IS 13770: 1993 for FRP


Sectional Hot Stick Rod

High Voltage Detectors


The Motwane HV Detector series provide an exceptional combination Applications
of user comfort and safety in one electrical safety device. The
Useful for Utility, Industrial, Railway and for Mine Safety
optimum LED layout, integrated audible signals and innovative self-
applications like following.
test features form the basic elements on all voltage detection
equipment types. HV Detector series are designed in contact type Contact/Non-contact detection of live voltages.
and non-contact type. The HV detectors are used to check for the Check and detect live high voltage cables.
absence or presence of voltage on medium and high voltage Trace live wires
switchgear, transformers or overhead lines – electrical safety is
Detect residual or induced voltages.
imperative in all areas of power transmission and distribution at all
voltage levels including MV, HV and EHV up to 400kV (suitable for 11
kV/ 33 kV / 132 kV / 220 kV/ 440 kV supply lines). It is available in FRP
Telescopic Rod/FRP sectional hot stick. Powered by a single 9V
battery. The HV detector starts annunciation with flashing red LED's
and buzzer beeps indicating that the line is live and not safe to earth
before carry any operations. HV Detector series is easy to use, hence
jobs get done more quickly and safely. Reliably detecting high
voltage on distribution and transmission voltage power lines is critical
jobs performed by electric utility linemen.

Non Contact Type Probe.

LEDs for Visual


Indication

Universal Link
High Voltage Detectors 94

Technical Details High Voltage Detectors

Technical Specification

Model HV50P HV50 HV132 HV220 HV440

Voltage Range 230V - 33kV 3.3kV - 33kV 11kV - 132kV 33kV - 220kV 66kV - 440kV

Type Non Contact Non Contact Contact/Non Contact Contact/Non Contact Contact/Non Contact

Sensing Distance - - 1mtr - 3mtr - 5mtr 1mtr - 3mtr - 5mtr 1mtr - 3mtr - 5mtr

General Specifications
High Voltage Indication

RED LEDs start flashing with an audible buzzer if taken into High Voltage induction area.

Electrical Specifications

Insulation Resistance Greater Than 100M Ohms by 1KV I.R. Tester.

Dielectric Strength Equivalent or greater than as per model selected.

Power Specifications Universal Link


Current Consumption 30mA maximum Material Glass Filled Nylon

Battery Low 7.2 V Nominal Length 95mm Approx

Battery 9V / Battery type 6F22 or equivalent Insulated Stick

Visual Indication High Bright LEDs flashing Material Fibre Glass (Sturdy & Rugged)

Audible Indication Buzzer beeps Loudly Length Telescopic Extendable length 3 mtrs.

for 33 KV & 5 mtrs. for 132 KV & above.

Environmental Specifications
Recommended Operating Physical Specifications
Temperature Range 5°C to 50°C Length 245mm Approx.

Humidity <85% RH non-condensing Diameter 105mm Approx

Storage Temperature 10°C to 60°C, Weight Approx. 2.5Kg.including

<85% RH non-condensing Range Telescopic Insulated Stick.

Accessories
Standard

FRP Telescopic Rod 1.2 / 3 / 5 metre OR

FRP sectional hot stick Rod 1.2 / 3 / 5 metre (Optional)

Carrying Bag

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Earth/Ground Tester - DET20 95

Features
3 ½ digit LCD Display with max reading 1999.
3 terminal and 4 terminal Measurement Method
Earth Resistance Range 0.01Ω to 1999Ω
4 Soil Resistivity Measurement
Rechargeable Internal Ni-MH Battery
Earth Measurement Voltage up to 200V
Ratio Metric Synchronous Rectification

Applications
The integrity of the grounding system is very important in
an electrical power system for the following reasons:

To maintain a reference point of potential (ground) for


DET 20 equipment and personnel safety. To provide a discharge
point for travelling waves due to lightning. To prevent
Digital Earth Tester
excessive high voltage due to induced voltages on the
power system
DET 20 is a conventional type 3 digit LCD display which is designed to
Therefor to maintain sufficiently low resistance values of
measure Earth Resistance, Soil Resistivity & Earth Voltage. It has a
grounding systems, their periodic testing is required. The
unique RSR technology in which even at the drop of battery voltage
testing involves measurement to ensure that they do not
the measurement reading remain constant. DET 20 has 128Hz test
exceed design limits.
frequency which eliminates the harmonics interference and has
rechargeable long-life battery which reduces the cost of battery. The measurement of ground resistances may only be
Earthresistance is measured by three wires & Soil Resistivity is accomplished with specially designed test equipment. The
measured by four wire measurement techniques. This meter is shock most common method for measuring ground resistance
proof, drop and dust proof. It has ABS casing which is useful for heavy uses the fall-of-potential principle of alternating current
duty. DET 20 is Type tested as per IS 9223. (AC) at higher frequency circulating between an auxiliary
electrode and the ground electrode under test; the reading
will be given in ohms and represents the resistance of the
ground electrode to the surrounding earth.

Soil Resistivity is also the key factor that determines what


the resistance of a grounding electrode will be, and to what
depth it must be driven to obtain low ground resistance. The
resistivity of the soil varies widely throughout the world and
changes seasonally. Soil Resistivity is determined largely by
its content of electrolytes, consisting of moisture, minerals,
and dissolved salts. A dry soil has high resistivity if it
contains no soluble salts. It figures has a direct impact on the
overall sub-station resistance and how much earth electrode
is required to achieve the desired values. Lower the
resistivity, fewer the electrodes required to achieve the
desired earth resistance value. Hence the Soil Resistivity is
also important test.

The methods of measuring and testing the Earth


Resistance and Soil Resistivity:

3 pole method used for Earth Resistance testing


4 pole method used for Soil Resistivity testing.
Earth/Ground Tester - DET20 96

Accessories
Technical Details DET 20
Standard

4nos. Spike of 10mm dis, 450mm long


10m, 20, 30m &40m of measurement cable
on a winder as standard.
Earth Resistance Ranges Battery Charger
0.01Ω to 19.99Ω Hammer
Carrying bag
0.1Ω to 199.9Ω
Instruction Manual
1Ω to 1999Ω

Accuracy (250C +50C)


Typically used for
+1.5% of reading +5 digits valid from 10% of reading to 95% of range.
Standard
Earth Voltage accuracy : 2% of Range
Substation Earth Testing.
Earth Voltage resolution : 0.1V
To test telecom tower grounding, Railways Earthing.
Test Frequency 128Hz ±0.5Hz To test the quality of grounding without disconnecting
the ground rod under test.
Test Current
Earth Resistance of Grid.
20 Ω Range : 10mA AC rms

200 Ω Range : 1mA AC rms

2000 Ω Range : 100mA AC rms

Test Current us generally constant throughout the range

Power Supply Internal, rechargeable Ni-MH 1.2V, 600mAh x 8nos.

Charging Time Recommended 16hrs.

Single Charge Battery life Approximately 5-6hrs of continuous

operation on mid-range.

Interference

Interference voltage of 20V +5% peak to peak, 50Hz in the potential circuit will

have a maximum effect +1% on the reading obtained form 20 Ω to 2KΩ ranges.

Influence of Temperature
<+0.2% per0 C over the temperature range 0-200C and 28-550C.

Temperature Range
Operating : 00C to +550C <90% RH

Storage : -200C to +700C <90% RH

Humidity

Operating : 95% RH non condensing max at 400C

Storage : 93% RH non condensing max at 550C

Flash Test : 2KV AC

Voltage withstand
In the event of as system fault, the instrument will withstand 240V AC, applied

between any two terminals.

Dimensions 180(H) x 100 (W) x54 (D) mm

Weight 550gms without accessories.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Earth/Ground Tester - DECT 3 97

Features
Resistance range up to 1200 Ohms.
AC Leakage Current Measurement up to 20A.
RS 232 Interface for monitoring, uploading analysing &
printing of data.
Memory Storage capability of 99 records.
Alarm setting feature with selection range available for
resistance and current.
Improved Jaw Opening & Closing
Fast self-test & Calibration.
Soft touch keys.
Rugged Casting and easy to use.

DECT 3
Digital Clamp on Earth Resistance Tester
Applications
Motwane's new Digital Clamp on Earth resistance Tester, DECT-3
Clamp on measurement method is new and quite unique. It
measures earth resistance using clamp on technology. Clamp on is a
offers the ability to measure the Earth Resistance without
relatively new method of determining the quality of a ground system.
disconnecting the ground. This type of measurement also
DECT-3 can measure Earth Resistance, earth bonds measurement &
offers the advantage of including the bonding to ground
also measures AC leakage current. It's actually recommended to use it
and the overall grounding connection resistances and also
on sites where there are multiple grounds placed in parallel and not
indispensable troubleshooting tools to help you maintain
required to isolate the ground rod. Simply clamp around the
uptime. It is recommended that all grounds and ground
conductor or earthing strip and measure the Earth Resistance fast and
connections be checked at periodically as a part of normal
accurately. The unique big jaw is particularly suitable where
predictive maintenance plan. If there is an increase more
grounding is done by flat steels or copper strips. It has low battery
than the acceptable limit during these periodic checks, the
indication & data hold facility within built memory storage of up to 99
engineer should investigate the source of the problem and
test results. DECT-3 has got the double insulation level and is
make the correction to lower the resistance by replacing or
protected from external magnetic & electric fields.
adding ground rods to the ground system.

Typically used for


Measures Earth Resistance of the electrical ground rod
and grid.
Utility Poles/Service Entrance or Meter
Street Lighting
Lightning Protection
Street Cabinets
Telephone Pedestals and Telecommunication Tower's
grounding
Cell Towers (applications with buried ground ring)
Pad Mounted Transformer
Pole Mounted Transformer
Measures AC leakage current of transformer neutral.
Conduct field surveys fast and effectively and retrieves
and analyses the readings for later reference.
Earth/Ground Tester - DECT 3 98

Technical Details DECT 3

Technical Detail

Mode Range Resolution Accuracy

0.010-0.099Ω 0.001Ω + (1% + 0.01Ω)

0.10-0.99Ω 0.01Ω + (1% + 0.01Ω)

1.0-49.9Ω 0.1Ω + (1% + 0.1Ω)

50.0-99.5Ω 0.5Ω + (5% + 5Ω)

Resistance 100-199Ω 1Ω + (5% + 5Ω)

200-395Ω 5Ω + (10% + 10Ω)

400-590Ω 10Ω + (10% + 25Ω)

600-880Ω 20Ω + (20% + 30Ω)

900-1200Ω 30Ω + (25% + 30Ω)

0-9mA 0.05mA Unspecified

10-99 mA 0.1mA + (2.5% + 20mA)

100-300mA 1mA + (2.5% + 20mA)


Current
0.30-2.99A 0.01A + (2.5% + 0.15mA)

3.0-9.9A 0.1A + (2.5% + 0.5mA)

10-20A 0.1A + (2.5% + 1A)

General
Display 4 digit LCD , 47 mm X 28.5 mm

Resistance Measurement Range 0.01 to 1200

Current Measurement Range 0 to 20 A

Memory Storage Facility 99 records

Computer Interfacing RS 232 for uploading the stored data and analysing at later time

Single Measurement Time 0.5 Second

Resistance Measurement Frequency > 1 KHz

Current measurement Frequency 50 / 60 Hz

Sound & Light annunciator Beep sound, Flashing Symbol, 'AL' key to turn on-off & setting the sound & Light alarm

Selection range of resistance for setting alarm value 1 Ω – 199

Selection range of current for setting alarm value 1mA - 499 mA

Protection Level Double Insulation

External Magnetic Field < 40 A/m

External Electric Field < 1V/m

Power Source 6VDC (4x1.5 V AA alkaline battery)

Auto Power Off Approx 5 minutes

Environmental Working Temperature: 100C to 550C Relative Humidity : 10% to 90%

Jaw Size 65mm X 32mm

Dimension (L x B x H) 285mm x 85mm x 56mm

Net Weight (Including Batteries) 1160 gms (Approx)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes continuous improvement of its product. We, therefore,
0 0
reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Earth/Ground Tester - DECT 2 99

Technical Details DECT 3

Accessories
Standard

Standard Loop Resistance of 5.1Ω

Instruction Manual

Carrying Case

Calibration Certificate
Earth/Ground Tester - DECT 2 100

Features
Display 4 digits LCD
Range : 0.01Ω to 1200Ω
Resistance Measurement Resolution 0.001
Memory storage capability of 99 records
Long jaw size: 65mm — 32mm
The unique Long Jaw is particularly suitable where
grounding is done by flat steel or copper strips
Alarm setting feature with selection range available
from 1 Ω to 199 Ω
Double insulation level and also protected from external
magnetic field as well as electric field
Automatic Range Selection, Automatic Self-Calibration
Single Measuring Time: 0.5 seconds

DECT 2
Digital Clamp on Earth resistance Tester

Applications
Clamp on measurement method is new and quite unique. It offers the
Clamp on measurement method is new and quite unique. It
ability to measure the earth resistance without disconnecting the
offers the ability to measure the earth resistance without
ground. This type of measurement also offers the advantage of
disconnecting the ground. This type of measurement also
including the bonding to ground and the overall grounding
offers the advantage of including the bonding to ground
connection resistances and also indispensable troubleshooting tools
and the overall grounding connection resistances and also
to help you maintain uptime. It is recommended that all grounds and
indispensable troubleshooting tools to help you maintain
ground connections are checked periodically as a part of a normal
uptime. It is recommended that all grounds and ground
predictive is seen maintenance plan. If an increase in resistance of
connections be checked periodically as a part of normal
more than acceptable limit during these periodic checks, the engineer
predictive maintenance plan. If an increase in resistance of
should investigate the source of the problem and make the correction
more than acceptable limit during these periodic checks,
to lower the resistance by replacing or adding ground rods to the
then the engineer should investigate the source of the
ground system.
problem and make the correction to lower the resistance by
replacing or adding ground rods to the ground system.

Typically used for


Measures Earth Resistance of the electrical ground
rod and grid.
Utility Poles/Service Entrance or Meter
Street Lighting
Lightning Protection
Street Cabinets
Telephone Pedestals and Telecommunication Tower's
grounding
Cell Towers (applications with buried ground ring)
Pad Mounted Transformer
Pole Mounted Transformer
Measures AC leakage current of transformer neutral.
Conduct field surveys fast and effectively and retrieves
and analyses the readings for later reference.
Earth/Ground Tester - DECT 2 101

Technical Details DECT 2

Technical Detail

Mode Range Resolution Accuracy

0.010-0.099Ω 0.001Ω + (1% + 0.01Ω)

0.10-0.99Ω 0.01Ω + (1% + 0.01Ω)

1.0-49.9Ω 0.1Ω + (1% + 0.1Ω)

50.0-99.5Ω 0.5Ω + (5% + 5Ω)

Resistance 100-199Ω 1Ω + (5% + 5Ω)

200-395Ω 5Ω + (10% + 10Ω)

400-590Ω 10Ω + (10% + 25Ω)

600-880Ω 20Ω + (20% + 30Ω)

900-1200Ω 30Ω + (25% + 30Ω)

General
Display 4 digit LCD , 47 mm X 28.5 mm

Resistance Measurement Range 0.01 to 1200


Memory Storage Facility 99 records
Single Measurement Time 0.5 Second
Resistance Measurement Frequency > 1 KHz
Current Measurement Frequency 50 / 60 Hz

Beep sound, Flashing Symbol, 'AL' key to turn


Sound & Light annunciator
on-off & setting the sound & Light alarm

Selection range of resistance for setting alarm value 1Ω – 199Ω

Protection Level Double Insulation


External Magnetic Field < 40 A/m

External Electric Field < 1V/m

Power Source 6VDC (4x1.5 V AA alkaline battery)

Auto Power Off Approx. 5 minutes

Working Temperature: 100C to 550C


Environmental
Relative Humidity : 10% to 90%

Jaw Size 65mm X 32mm


Dimension (L x B x H) 285mm x 85mm x 56mm
Net Weight (Including Batteries) 1160 gms (Approx)

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Multimeter - M63 102

Features
6000 Count LCD display with pleasant white backlit.
AC/ DC Current range upto 20A.
Resistance, Capacitance, Diode & Continuity
Measurement Facility.
Selectable Frequency & Duty Cycle Measurement.
60 position analog bar graph for trend indication.
Highly Linear Readings.
Select, Range, Hold/Light, Rel, Hz/duty.
Max/Min functions incorporated
Safety - CE, CAT IV(600V), IP 54, EN61326-1 & IEC 61010-1
Robust, Rugged & Double Mould Casing.

M63
Digital Multimeter Industrial Graded

CAT iV IP Applications
600V 54 Power Utility
Industries
The Motwane’s Terms Industrial Graded Digital Multimeter M63 is Electrical Contractor
specially designed in our research laboratory & went under stringent
Telecommunication
manufacturing process for a wide range of applications like Power
Railway
Generation, Power Distribution, Power Transmission, Steel Industries,
Defence
Cement Industries, Mining Industries, Power Electronics Industries,
Heavy Engineering Industries and Defence Sector & Aviation Sector.
M63 is a versatile and high-performance industrial grade multimeter
that complies with IEC 61010-1-2010 safety standards and excellent
noise immunity to disturbances from energized power lines, with CE,
CAT IV 600 V safety rating IP-54 protection.
Digital Multimeter - M63 103

Technical Details M63

General
Display 6,000 Count LCD display with white backlit.

Display Update Rate 3 times per second nominal.

Dimensions (WxHxD) 94 X 205 X 36 mm Approx

Weight 450g. Approx

Environmental

Environmental 0°C to 50°C

Relative Humidity 80% RH @ 5°C to 31°C

50% RH @ 31°C to 40°C Non condensing

Storage Temperature - 20°C to 60°C

Power
Power Supply 9V Battery Type 6F22 or equivalent

Power Consumption 4mA typical.

Low Battery Indication 'LO BAT' is displayed below 6.5V approx.

Auto Power OFF After 15 Min., Ideal sleep mode

consumption is 300uA approx. (Can be cancelled by pushing SELECT key before power on the meter).

Overload Protection:
Fuse Protection for ‘mA’ input terminal 0.75 A/ 0.8 A/ 500V fast blow type ceramic fuse.

Fuse Protection for 20A input terminal 20A/ 500V fast blow type ceramic fuse

Ω/ / / / /Hz(%) 1000 V DC / AC rms

Safety

Directives for CE Certification LVD:2006/95/EC., EMC: 2004/104/EC

Measurement Category CAT IV, 600V Reinforced Insulation.

Relevant Standard Specification EN 61010-1:2010, EN61326-1:2006

IP Rating (Dust & Water Protection) IP54

Accessories

Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.

DC Voltage
Range Resolution Max. Reading Accuracy Overload Protection

600m 0.1 mV 600.0 mV +(0.5% + 3)

V6V 1 mV 6.000 V +(0.5% + 3)

60V 10 mV 60.00 V +(0.5% + 3) 1050V DC/AC rms

600V 100 mV 600.0 V +(0.5% + 3)

1000V 1V 1000 V +(0.8% + 3)

Note: Input Impedance 10MΩ approx.


Digital Multimeter - M63 104

Technical Details M63

AC Voltage (50-500Hz)Trms
Range Resolution Max. Reading Accuracy Overload Protection

6V 1 mV 6.000 V +(1% + 5)

60V 10 mV 60.00 V +(1% + 5)

600V 100 mV 600.0 V +(1% + 5) 1050V DC/AC rms

750V 1V 750 V +(1.2% + 8)

Note : Input impedance : 10 MΩ approx. shunted by 60pF approx

DC ‘mV’ Range
Range Resolution Max. Reading Accuracy Overload Protection
60 mV 0.01 mV 60.00 mV +(0.5% + 3)
1000V DC/AC rms
600 mV 0.1 mV 600.0 mV +(0.5% + 3)

Input Impedance : 1000MΩ approx.

AC ‘mV’ Range (50Hz-1KHz) Trms


Range Resolution Max. Reading Accuracy Overload Protection
60 mV 0.01 mV 60.00 mV +(1% + 3)
1000V DC/AC rms
600 mV 0.1 mV 600.0 mV +(1% + 3)

Input Impedance : 1000MΩ approx.

DC Current Range

Range Resolution Max. Reading Accuracy Overload Protection


60 mA 0.01 mA 60.00 mA +(1% + 5) 0.75A/0.8A/ 500V DC/AC

0.1 mA 600.0 mA +(1% + 5) fuse protection


600 mA

6A 1 mA 6.000 A +(1% + 5)
20A/500V DC/AC

20 A 10 mA 20.00 A +(1.2% + 8) fuse protection

Note : 1. 10A for continuous 2. >10A for 20sec. after 15min. cool down interval

AC Current Range (50Hz-500Hz) Trms


Range Resolution Max. Reading Accuracy Overload Protection
60 mA 0.01 mA 60.00 mA +(1.2% + 5) 0.75A/0.8A/ 500V DC/AC

0.1 mA 600.0 mA +(1.2% + 5) fuse protection


600 mA

6A 1 mA 6.000 A +(1.2% + 5)
20A/500V DC/AC

20 A 10 mA 20.00 A +(1.5% + 5) fuse protection

Note : 1. 10A for continuous 2. .>10A for 20sec. after 15min. cool down interval

Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection
600 Ω 0.1 Ω 600.0 Ω +(0.5% + 3)
6 KΩ 1Ω 6.000 Ω +(0.5% + 3)
60 KΩ 10 Ω 60.00 K Ω +(0.5% + 3)
1000V DC/AC rms
600 KΩ 100 Ω 600.0 K Ω +(0.5% + 3)
6 MΩ 1KΩ 6.000 M Ω +(1% + 5)
60 MΩ 10 K Ω 60.00 M Ω +(3% + 5)
Note : 1. Open Circuit Voltage on 600 -6M ranges is 0.62V DC approx. 2. Open Circuit Voltage on 60M range is 0.31V DC approx
Digital Multimeter - M63 105

Technical Details M63

Capacitance Range (Auto Ranging Only)


Range Resolution Max. Reading Accuracy Overload Protection

40 nF 0.01 nF 39.99 nF +(3.0% + 10)

400 nF 0.1 nF 399.9 nF +(3.0% + 10)

4 µF 1 nF 3.999 µF +(3.0% + 10)


1000V DC/AC rms
40 µF 10 nF 39.99 µF +(3.0% + 10)

400 µF 100 nF 399.0 µF +(3.0% + 10)

4000 µF 1 µF 3999 µF +(5.0% + 20)

Note : Setting time on 4000uF range is 40sec. approx.

Continuity Test
Range Resolution

600.0Ω 0.1Ω Meter Beeps at 60Ω

Note : Open Circuit Voltage on continuity range is 0.64VDC approx.

Frequency Ranges (Auto Ranging Only)


Range Resolution Max. Reading Accuracy Overload Protection

10 Hz 0.001 Hz 9.999 Hz +(0.1% + 3)

100 Hz 0.01 Hz 99.99 Hz +(0.1% + 3)

1 KHz 0.1 HZ 999.9 Hz +(0.1% + 3)

10 KHz 1 Hz 9.999 KHz +(0.1% + 3) 1000V DC/AC rms

100 KHz 10 Hz 99.99 KHz +(0.1% + 3)

1000 KHz 100 Hz 999.9 KHz +(0.1% + 3)

10 MHz 1 KHz 9.999 MHz +(0.1% + 3)

Note : Setting time on 4000uF range is 40sec. approx.

Duty Cycle Measurement


Range Resolution Accuracy Overload Protection

0.1%-99.9% 0.1% +(0.5% + 3) 1000V DC/AC rms

Accessories
Standard

Standard Accessories

Pair of Test leads, User Manual, Battery installed,

Fuses, Carrying Bag.

Optional

Pair of test leads.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Digital Multimeter - M65 106

Features
6,000 Count LCD Dual display with white backlit.
Auto ranging, terms AC Voltage & Current measurement.
Basic DCV Accuracy of 0.25%.
Highly Linear Readings.
Capacitance Range upto 60mF.
Resistance, Diode and Continuity Measurement Facility
Selectable Frequency & Duty Cycle Measurement.
60 position analogy bar graph for trend indication.
Select, Range, Hold, Rel, Lights, Max/Min
Functions Incorporated.
CE and IEC 61010-1 CAT III (1000V), IP 54 protection.
Robust, Rugged and Double Mould Casing.

M65
Digital Multimeter

CAT III IP Applications


1000V 54 Power Utility Industries
Electrical Contractor
The Motwane M65 Dual display Terms Digital Multimeter with high Telecommunication
accuracy, is specially designed in our Research Laboratory and
Railway
manufactured under stringent manufacturing processes for R&D and
Defence
Process industries. M65 has 6000 count LCD dual display and
measuring facilities like capacitance, resistance, diode and continuity
as well as comes with µ Amp. range & DCV accuracy of 0.25%. M65
includes the features you need to troubleshoot and repair electrical
and electronic systems.

M65 is a high performance multimeter complies with IEC 61010-1


safety standards and with CE, CAT III 1000 V safety rating, meeting
with IP54 protection. M65 is designed very robust and rugged with
double mould casing.
Digital Multimeter - M65 107

Technical Details M65

Accuracy
Accuracy is valid from 10% of range to 95% of the range.

Accuracy is specified as + % of reading + digits and is valid at 25 + 30C, < 55% RH Humidity.

It is recommended that calibration equipment used to verify the accuracy of the instrument should be 10 times more accurate.

Temp. Coefficient = (0.1% x Specified accuracy) per degree centigrade referred to 25°C. Accuracy is not valid if display shows ' LO BAT'.

General

Display 6,000 Count Dual, LCD display with white backlit.

Display Update Rate 2.8 times per second nominal.

Dimension 94mm(W) X 205 mm(H) X 36 mm (L ) approx.

Weight 450g. approx.

Dual Display For AC Voltage with Frequency & Frequency with Duty Cycle simultaneously

Environmental
Operating Temperature 0°C to 50°C

Relative Humidity 80% RH @ 5°C to 31°C

50% RH @ 31°C to 40°C, Non condensing

Storage Temperature - 20°C to 60°C

Power
Power Supply 9V Battery Type 6F22 or equivalent

Power Consumption 8mA typical.

Low Battery Indication 'LO BAT' is displayed below 6.5V approx.

Auto Power OFF After 15 Min., Ideal sleep mode

consumption is 1.3mA approx. (Can be cancelled by pushing any except for

Hold & SELECT key before power on the meter).

Overload Protection
Fuse Protection for ‘µA’ & ‘mA’ input terminal 0.8 A/ 250V fast blow type ceramic fuse.

Fuse Protection for 10A input terminal 20A/ 500V fast blow type ceramic fuse

V/Ω/ / / /Hz (%) 440 V DC / AC rms

Safety

Directives for CE Certification LVD:2006/95/EC., EMC: 2004/104/EC

Measurement Category CAT III, (1000V) Reinforced Insulation

Relevant Standard Specification EN 61010-1:2010, EN61326-1:2006

IP Rating (Dust & Water Protection) IP 54

Accessories
Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.
Digital Multimeter - M65 107

Technical Details M65

Optional Accessories
Pair of test leads, Pair of small test leads

Range Resolution Max. Reading Accuracy Overload Protection

6V 1 mV 6.000 V +(0.25% + 3)

60V 10 mV 60.00 V +(0.25% + 3)


1050V DC/AC rms
600V 100 mV 600.0 V +(0.25% + 3)

1000V 1V 1000 V +(0.5% + 3)

Note: 1. Input Impedance 10M approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).

AC Voltage (50-500Hz) Trms


Range Resolution Max. Reading Accuracy Overload Protection

6V 1 mV 6.000 V +(1% + 5)

60V 10 mV 60.00 V +(1% + 5)


1050V DC/AC rms
600V 100 mV 600.0 V +(1% + 5)

1000V 1V 1000 V +(1.2% + 8)

Note : 1. Input impedance : 10 MΩ approx. shunted by 60pF approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).

3. Main display shows AC Voltage & sub display shows frequency applied.

DC Current Range
Range Resolution Max. Reading Accuracy Overload Protection

600µA/6000µA 0.1µA/1µA 600.0µA/6000µA +(1.2% + 5)


0.8A/ 250V DC/AC
fuse protection
60mA/600 mA 10µA/100µA 60.00mA/600.0 mA +(1.5% + 5)

20A/250V DC/AC fuse


10 A 10 mA 10.00 A +(1.5% + 8)
protection

AC Current Range (50Hz-500Hz) Trms


Range Resolution Max. Reading Accuracy Overload Protection

600µA/6000µA 0.1µA/1µA 600.0µA/6000µA +(1.5% + 5)


0.8A/ 250V DC/AC fuse
protection
60mA/600 mA 10µA/100µA 60.00mA/600.0 mA +(1.8% + 5)

20A/250V DC/AC fuse


10 A 10 mA 10.00 A +(2.0% + 8)
protection

Note: Main display shows AC Current and sub display shows frequency applied.

Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection

600 Ω 0.1 Ω 600.0 Ω +(0.5% + 3)

6 KΩ 1Ω 6.000 Ω +(0.5% + 3)

60 KΩ 10 Ω 60.00 KΩ +(0.5% + 3)
440V DC/AC rms
600 KΩ 100 Ω 600.0 KΩ +(0.5% + 3)

6 MΩ 1 KΩ 6.000 MΩ +(1% + 5)

60 MΩ 10 KΩ 60.00 MΩ +(3% + 10)

Note : 1. Open Circuit voltage on 600Ω range is -3.3V DC approx. 2. Open Circuit voltage on 6kΩ-6MΩ ranges is -1.10V DC approx.

3. Open Circuit Voltage on 60MΩ range is -600mV approx.


Digital Multimeter - M65 109

Technical Details M65

Capacitance Range (Auto Ranging Only)

Pair of test leads, Pair of small test leads

Range Resolution Max. Reading Accuracy Overload Protection

6 nF 0.001 nF 6.000 nF +(5.0% + 10)

60 nF 0.01 nF 60.00 nF +(3.0% + 10)

600 nF 0.1 nF 600.0 nF +(3.0% + 10)

6 µF 1 nF 6.000 µF +(3.0% + 10)


440V DC/AC rms
60 µF 10 nF 60.00 µF +(3.0% + 10)

600 µF 100 nF 600.0 µF +(5.0% + 10)

6 mF 1 µF 6.000 mF +(5.0% + 20)

60 mF 10 µF 60.00 mF +(5.0% + 30)

Note : 1. Settling time on 6mF and 60mF range is 40 sec. approx. 2. Press REL button at 6nF & 60nF ranges so that the offset count can be subtracted

from measurement. Now apply low value capacitance.

Diode Test
Range Resolution Open Circuit Voltage Test Current
6V 1mV <3.0 V DC approx. <2.0mA approx.

Continuity Test
Range Resolution
600.0Ω 0.1Ω Meter Beeps < 60Ω

Note: Open Circuit Voltage on continuity range is -3.3VDC approx.

Frequency Ranges (Auto Ranging Only)


Range Resolution Max. Reading Accuracy Overload Protection

60 Hz 0.01 Hz 60.00 Hz +(0.5% + 3)

600 Hz 0.1 Hz 600.0 Hz +(0.5% + 3)

6 KHz 1 HZ 6.000 KHz +(0.5% + 3)

60 KHz 10 Hz 60.00 KHz +(0.5% + 3) 1000V DC/AC rms

600 KHz 100 Hz 600.0 KHz +(0.5% + 3)

6 MHz 1 KHz 6.000 MHz +(0.5% + 3)

60 MHz 10 KHz 60.00 MHz +(0.5% + 3)

Note: 1. Main display shows frequency & sub display shows Duty Cycle. 2. If input frequency is less than 6.0Hz, display will show 0.00Hz.

Duty Cycle Measurement


Range Resolution Open Circuit Voltage Test Current
0.1%-98.9% 0.1% +(0.5% + 30) 440V DC/AC rms

Accuracy is specified at <20 VAC rms Sensitivity : 10Hz to 100 KHz > 200mVrms, 1000 KHz to 10MHz > 2Vrms

Electromagnetic compatibility: In RF Field, overall accuracy is equal to 10% of reading +30 digits

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Digital Clamp Meter - DCM49A 110

Features
3 ¾ digit LCD, 4000 counts, multi-function 1000A AC/DC.
Large Jaw Size : 60mm.
Function Rich, AC/DC Current, AC/DC Voltage, Resistance,
Diode, Continuity, Capacitance, Frequency and Duty Cycle.
Large Backlit display with rich annunciations.
Auto Power Off for battery life saving.
Relative Reading and Data Hold Functions.
Ergonomic Design for holding.
Suitable for use in Appliance Testing, Portable Tools,
Building Wiring
Testing of Electronic / Electrical Products.

DCM49A
Digital Clamp Meter

CAT II Applications
600V Power Utility
Industries
DCM49A is a general-purpose 3 ¾ digit AC / DC Clamp Meter with a Electrical Contractor
backlit LCD display. The jaw opening is 60mm approx. & can measure Telecommunication
AC / DC current through the clamp up to 1000A. It also measures DC Railway
Voltage-1000V, AC voltage-700V, and resistance up to 40M ,
frequency 10 MHz with duty cycle, continuity & diode measurements.
This meter also has a capacitance range of up to 100µF & is powered
by one 9V battery.
Digital Clamp Meter - DCM49A 111

Technical Details DCM49A

Accuracy
Accuracy are claimed from 10% of range to 95% of the range.

All claim of Accuracy are at decade value i.e 10, 100 tec.

Accuracy is specified as +(% of reading + offset in least count digits)

Accuracy claims at 230C ± 30C, 55% +10% RH Humidity.

General

Display 4000 Counts, LCD display

Dimensions 260 mm(W) X 91 mm(H) X 44.5 mm(D) approx

Weight 500g. approx

Environmental
Operating Temperature 0°C to 40°C <80% RH (Non condensing)

Storage Temperature - 10°C to 60°C <80% RH (Non condensing)

Battery Removed

Temperature coefficient 0.1 X Accuracy / deg C.

Power
Power Supply 9V Battery NEDA 1604 / Type 6F22/006P

Auto Power OFF 30 min of Ideal condition

consumption is 1.3mA approx. (Can be cancelled by pushing any except for -

Hold & SELECT key before power on the meter).

Safety In accordance with IEC61010-1 and IEC61010-2-32, Double insulation

DC 1000V and AC 700V, CAT II and pollution degree II

Standard Accessories
Pair of Test leads, User Manual, Battery installed

Range Accuracy Overload Protection Input Impedance

4V

40V
+(1.5% + 10d) 1000V DC OR 750 V AC rms 100M
400V

1000V

AC Voltage (50-500Hz) Trms


Range Accuracy Overload Protection Input Impedance

4V

40V
+(1.5% + 10d) 1000V DC OR 750 V AC rms 100M
400V

700V
Digital Clamp Meter - DCM49A 112

Technical Details DCM49A

DC/AC (50-60Hz) : (Manual Ranging)


Range Resolution Accuracy Overload protection

400A 0.1A
+(2.5% + 10d) 102% of Full scale for <60 Sec.
1000A 1A

Resistance Range (Auto/Manual)


Range Resolution Overload Protection
400 Ω

4 KΩ

40 KΩ
+(1% + 5d) 250V DC/AC rms
400 KΩ

4 MΩ

40 MΩ

Capacitance Range (Auto Ranging)


Range Accuracy Overload Protection Open Circuit Voltage

100 µF +(3.0% + 10d) 250V DC or AC rms <0.8V

Diode Test : Measure forward voltage drop. Evers circuit. Voltage approx. 1.5V Input protected upto 250V DC or AC rms.

Continuity : Buzzer sound if resistance <50 Ω, Input protected upto 250V DC or AC rms.

Frequency Ranges (Auto Ranging Only)


Range Accuracy Sensitivity Overload Protection

10 MHz +(0.5% + 10d) 4V 250V rms AC or DC

Duty Cycle
Range Accuracy Sensitivity Overload Protection

0.1%-99.9% 0.1% 4V 250V rms AC or DC

Note : Its use is not advised on multi phase high energy circuits where heavy transient are likely to occur.

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Digital Clamp Meter - DCM 39A/9930A 113

Features
Auto Ranging 3 ¾ digits (3999) LCD-Display.
True RMS reading for ACV & ACA
2 in 1 Clamp Meter + Digital Multimeter.
Overload protection for all ranges.
Data Hold, Relative Key Facility
Water Resistant front panel, Fireproof heavy-duty
ABS Casing.
Current Sensor-Hall Effect Sensor
Over Range Indication: 'OL' is displayed.
Max Conductor size 60mm approx.
Power – one 9V battery type (6F22)

DCM 39A/9930A
Digital Clamp Meter

Motwane's Digital Clamp Meter DCM 39A & DCM 9930A are highly Applications
precise, industrial grade, Trms, auto ranging clamp meters with 3 ¾
digit display. Both these clamp meters can be used as multimeter Generation, Transmission & Distribution
with test leads for AC/DC Current measurements up to 400 mA, Substation Process Industries.
AC/DC Voltage, Resistance, Frequency, Capacitance, Duty Cycle and OEM's
Diode, Continuity etc. These clamp meters are provided with safety Railway's
features like water resistant front panel, fireproof heavy-duty ABS Telecom Industries
casing. It uses a Hall Effect Sensor for measuring the current. The
Service Industries
model DCM 39A measures AC/DC currents up to 1000A. The model
DCM 9930A measures AC/DC currents up to 2000A.
Digital Clamp Meter - DCM 39A/9930A 114

Technical Details DCM 39A/9930A

General
Display 3 ¾ Digits LCD display.

Dimension 255 mm (H) X 73 mm (W) X 38 mm(L) (approx.)

Net weight 515 gm with battery (approx.)

Power

Power Supply 9V Battery Type 6F22

Standard Accessories
Pair of Test leads, User Manual, One 9V Battery installed

AC/DC Current (True rms for AC)- DCM39A


Range Resolution Input Accuracy

400 µA 0.1 µA + 1.2% + 5dgt

4000 µA 1 µA + 1.2% + 5dgt


Direct Input (by using leads)
40 mA 0.01 mA + 1.2% + 5dgt

400 mA 1 mA + 1.2% + 5dgt

400 A 0.1 A + 2% + 8dgt


Indirect Input (by using clamp)
1000 A 1A + 2% + 8dgt

Overload Protection : AC/DC 500mA(Fuse) | AC/DC 1000A/1000V | Frequency Response : 45Hz - 1KHz

Common Technical Specification for DCM39A and DCM9930A


DC Voltage
Range Resolution Accuracy Overload protection

400mV 0.1 mV + 0.5% + 2dgt

4V 0.001 V + 1% + 2dgt
1000V DC OR 1000V
40V 0.01 V + 1% + 2dgt
AC rms (Sine wave)
400V 0.1 V + 1% + 2dgt

1000V 1V + 1% + 2dgt

Input Impedance : 10MΩ (Approx)

AC Voltage
Range Resolution Accuracy Overload protection

4V 0.001 V + 1.2% + 5dgt

40V 0.01 V + 1.2% + 5dgt 1000V DC OR 1000V


AC rms (Sine wave)
400V 0.1 V + 1.2% + 5dgt

1000V 1V + 1.2% + 5dgt

Input Impedance : 10MΩ (Approx) | Frequency Response : 45Hz - 1KHz


Digital Clamp Meter - DCM 39A/9930A 115

Technical Details DCM 39A/9930A

Resistance Range
Range Resolution Input Accuracy

400 Ω 0.1 Ω + 1% + 5dgt

4 KΩ 1Ω + 1% + 5dgt

40 KΩ 10 Ω + 1% + 5dgt
400V DC/AC RMS (Sine wave)
400 KΩ 100 Ω + 1% + 5dgt

4MΩ 1 KΩ + 2% + 2dgt

40 M 10 K + 3.5% + 5dgt

Capacitance Range
Range Resolution Input Accuracy

50Hz 0.01HZ + 1% + 5dgt 1000V AC/DC

500Hz 0.1Hz + 1% + 5dgt

5KHz 1Hz + 1% + 5dgt 1000V AC/DC

50KHz 0.01 kHz + 1% + 5dgt

100KHz 0.1 KHz + 1% + 5dgt

Amplitude : < 5V

Duty Cycle
Range Resolution Accuracy Overload protection
0.1%-99% 0.1% + 1% + 5dgt 1000 V AC/DC

Diode : Measures forward voltage drop

Continuity Check : Buzzer sound if Resistance < 10

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Notes :
Notes :
Contact Details Scan the QR code to visit
Motwane’s new website

The MOTWANE Manufacturing


Company Private Limited

Gyan Baug, Nashik Road,


422101 Maharashtra, India

www.motwane.com

Toll-free number:
National : 17/08/2021

1800 233 7766

https://www.linkedin.com/company/motwanemanufacturing

You might also like