Professional Documents
Culture Documents
PRODUCT CATALOGUE
Table of Contents
4. Protection Testing
Circuit Breaker Timer Kit : MCBT-P 63
Circuit Breaker Operational Analyser : MCBO-A 66
Circuit Breaker Operational Analyzer - MCBOA Plus 73
Portable Dynamic Contact Resistance Meter : MDCR-M 76
DC Ground Fault Locator : MGFL 78
Leakage Current Monitoring : MLCM 81
Leakage Current Monitor : MLCM-B2 83
AC-DC Hi Pot Test Set : HVT Series 85
Relay Test Set : MOT - RTS 87
Primary Current Injection Kit : PIK Series 90
Motwane is an Indian engineering company with an To be collaborative, curious, and authentic are the core
impressive legacy and a strong focus on R&D and IoT values that have been part of Motwane’s success story from
capabilities Its products, ranging from power plants to the start.
plug points, and surpass existing quality standards, are
synonymous with robust, reliable, and long-last What Make Motwane Unique ?
performance.
Pioneers
As a result, the Motwane brand has earned the trust of
clients over the last 100 years with its innovative, energy- We are innovators in the design and manufacture of high-
efficient, and user-friendly solutions. performance, high-precision electrical Test & Measurement
equipment.
Innovation
We create innovative IoT technologies and digital offerings
that are designed to boost productivity, efficiency, energy
saving, proactive decision making, and help our customers
to take a step towards a green, more sustainable future
R&D Facilities
We work in world-class R&D facilities in which all of
Motwane’s products and solutions are indigenously
designed by over 40 technologists. Maybe not world class?
Our Journey
A Legacy of Innovation
We are committed to taking the
Motwane was one of the earliest manufacturing
passion Mr. Nanik Motwane showed
companies during the time of the British Raj.
in the early days of the company
Inaugurated in 1909, Motwane started out
from a patriotic past into the
pioneering the mass medium of radio, and from
digital future.
then on, the firm’s history has been tightly
interwoven with the history of India. In 1929, 18
years before Indian Independence in 1947, the The bottom line of hope
Freedom Movement led by Mahatma Gandhi was
Motwane strives to continue to leave a mark on Indian
well under way. Motwane’s Managing Director at history – within the country’s boundaries and abroad - and
the time, Nanik Motwane, recounts: to help shape the next generation of engineers to
successfully tackle the challenges of tomorrow. Driven by
“ I saw Gandhi-ji going from insatiable curiosity, and the will to never give up, we work
platform to platform to
hard to create digital and physical spaces where we can
address meetings at one
turn dreams into realities. Our hope lies in being able to
and the same place, to
enable his weak voice to be predict the future by learning from the past, live in
heard by large numbers. It harmony with nature and each other, and to use the
was then that I felt that I advancements of technology and our capacity as
must find some means to
‘machine whisperers’ to create a safer, more equal, and
amplify his voice. ”
creative world.
Mr. Nanik G. Motwane
The last 100 years has seen the company rise to a Industrial & Commercial
significant position across the electrical sector in India and Embracing the global shift towards intelligent, cloud-
abroad, pioneering electrical test & measurement based technologies, Motwane offers efficient solutions
equipment that set market benchmarks for a wide range of that help its clients to take the necessary leap towards a
clients. Motwane’s long-standing commitment to greener future.
innovating products that anticipate future needs has led to
further diversification, and the creation of MOT-WARE, an
IoT-based test data software, AI engines for data
vis u al i s at io n , s m ar t lig ht i n g , a n d o t he r e n e rgy
management solutions.
Electrical
Working closely with our customers enables Motwane to
successfully innovate, design, and engineer future-ready
solutions. For the electrical sector, we have engineered a
variety of high precision test & measurement equipment
that have been industry standard for decades. Our
electrical business is organised into the following two
verticals.
The world is transitioning through a massively changed
Power & Grid technological landscape. There is a global shift towards cloud-
For decades, Motwane’s Test & Measurement product based IoT technologies that have become a part of day-to-day
Operations in intelligent factories, industry 4.0, green
range has helped clients to maintain efficiencies, ensure
buildings, and net-zero, with the remote monitoring of capital
safety, and increase profitability.
equipment through ‘digital twins’.
CE Certification
CE marking is an administrative marking that indicates
conformity with health, safety, and environmental protection
standards for products sold within the European Economic
Area (EEA).
Product & Services 6
MOT-WARE
IoXn
Motwane built its proprietary IoXn technology, an
easyto- install ‘plug & play’ product, that connects
various assets: transformers, Chillers, Water Meter,
Motors, etc. to the cloud. Enjoy real-time monitoring
and asset management with the magic of one touch
through MOT-WARE.
Motwane Academy
Motwane academy is built to bridge the skill gap and
enable the future of engineers with better
opportunities and technology.
Test & Measurement - 10K PI 8
Features
Available IR Testing with Diagnostic Modes
PI, DAR, DD, Step Voltage, BDV & Burn Test
Programmable Test Voltage from 500V-10KV
Insulation Resistance Range from 1KΩ to 20TΩ
Three Programmable Timers
Programmable Break Down Current Settings
Mains & Battery operation
Internal Data Storage up to 1000 tests*
Galvanic Isolated RS 232 & USB Port
Application Software for Data Trending Analysis
AC/DC voltage measurement up to 600V
Auto Calibration at every start up
Burn Mode for uninterrupted Insulation Resistance Testing
Alarm Mode with Min-Max Settings & Pass Fail Indication
CAT IV 600V, IP54, Complies with latest IEC/IS Standards
Hand Interlock Switch
10K PI
Diagnostic Insulation Tester
CAT IV IP Applications
600V 54
The Insulation Resistance Test is an essential test that helps
to verify the condition of electrical insulation. Insulation
10K PI is an Insulation Diagnostic Tester having test voltage range up
resistance quality of an electrical system degrades with
to 10KV, designed & developed indigenously at the state of the art
time, environment condition i.e. temperature, humidity,
R&D laboratory to conduct automatic insulation tests on high voltage
moisture and dust particles. The instrument is designed for
equipment's like Transformers, Cables, Bushings, Switchgears &
routine insulation resistance testing and diagnostic testing
Rotating Machines 10K PI is a microprocessor based instrument
like PI, DD, DAR & SV of high voltage electric apparatus like
deploying the latest technology & very high speed data sampling to
transformers, generators, motors, cables, bushings, LAs,
give correct, repetitive readings & quality performance under harsh
switchgear, etc. and is temperature independent. Trending
electrical conditions. It has a wide insulation resistance range up to
of data can reveal vital information about insulation quality
20TΩ. and enables the user to take informed decision.
Power Supply
Technical Details 10K PI Mains 85V-265V, 50Hz +10%
Voltage Selectable 500V, 1KV, 2.5KV, 5KV, 7.5KV, 10KV Operating Temperature 0℃ to 55℃
Voltage Accuracy ±5 %
Safety Standards
Short Circuit Current 3mA
Safety in accordance with EN61010-1
Resistance Range
EMC in accordance with EN61326-1
Analog Display 1 KΩ to 10 TΩ
Type test in accordance with IEC 60068
Digital Display 1 KΩ to 20 TΩ
Test leads in accordance with IEC61010-31,
Accuracy +5% (Upto 999GΩ )
CE & CAT IV600V, IP 54
+10% (1TΩ to 10TΩ )
Programmable Timer T1, T2 & T3 (0-99Min 59sec) Dimension 195mm(H) X 290mm(W) X 360 mm(L)
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - 5K PI 10
Features
Programmable Test Voltage 250 - 5000V in steps of 50V
Insulation Resistance upto 10TΩ
Three Programmable Timers
Modes for conducting IR, Leakage current, PI, DAR,
DD, SV and BDV test
Mains & Battery Operation
CE, CAT-IV 600V, IP65, complies with latest IEC/IS
Standards
1000 test results storage
Optically Isolated RS-232 port & USB port
AC / DC Voltage Measurement
Pass Fail Limit is provided with software generated results
Bluetooth enabled for Motware Mobile App
Connected to Cloud
5K PI
Diagnostic Insulation Tester
Range 10nF to 50µF After the end of the test, the result including resistance,
Accuracy +10% of rdg. leakage current, time & capacitance information will be
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - 5K PI 12
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Selectable Test Voltage from 250V, 500V, 1000V, 2500V,
5000V DC.
Insulation Resistance Measurement up to 1TΩ
Polarization Index Measurement Facility
Short Circuit Current < 2 mA + 0.5 mA
AC/DC Voltage Measurement up to 600V.
Two Programmable Timer from 0 sec to 99 minutes
Liquid Crystal Display with pleasant white backlit.
Internal rechargeable Battery.
Safety - IP 54, CAT IV 600V and CE conformity.
Robust ABS body with self-carrying handle for easy
portability.
Automatic discharge for capacitive circuits.
Guard Terminal to minimize the surface leakage
Pass - Fail Limit
IT 51
5KV Digital Insulation Resistance with Polarization Index
CAT IV IP Applications
600V 54
The Insulation Resistance Test is an essential test that help to
verify the condition of electrical insulation. Insulation
The Motwane IT-51 is a microprocessor based Digital Insulation Tester resistance quality of an electrical system degrades with
designed for testing all types of electrical apparatuses like time, environment condition i.e. temperature, humidity,
transformers, switchgears, motors, generators, cable and substation moisture and dust particles. The instrument is designed for
products. IT-51 has a digital display and an analog arc display. The routine and diagnostic testing like IR, PI of high voltage
instrument automatically performs IR Test and Polarization Index Test electric apparatuses like.
by selecting the mode. IT-51 has a large LCD white backlit display, it
shows leakage current in scrolling form along with IR value and PI All electrical rotating machineries
value. Transformers
HV & LV Switchgears
Insulation Resistance Test : The is an important test for future
comparative purposes, acceptance test and also for determining the Cables
Insulation Resistance
Accessories
Analog Display 1 KΩ to 1 TΩ
Standard
Digital Display 1 KΩ to 1 TΩ (3 Digit Display)
Test leads 3 meter : 1 Set
Insulation Accuracy User Manual : 1 No
Up to 1GΩ All Ranges ± (2 % + 2 digits) Calibration Sheet : 1 No
Resolution 0.01
General
Environmental Specifications
Operating Temperature -10°C to 55°C
at 40°C
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - IT-250G Spot 15
Features
Selectable Test Voltage from 250V, 500V, 1000V, 2500V,
5000V DC
Insulation Resistance Measurement up to 250GΩ
Short Circuit Current < 1.4 mA. approx
Programmable Timer from 1 sec to 99 minutes
Internal Memory Storage of 1000 readings
Auto Power Off to save battery
Auto Calibration at every start up.
Continuity Testing at 100mA approx.
GUARD Terminal to eliminate surface leakages.
Battery Status Indicator
Safety/EMC CE CAT III (1000V)/ CAT IV (600V), IP54
Shock proof, heavy duty & shrouded test lead
Inbuilt Digital Filter
IT-250G
5KV Battery Operated Digital Insulation Resistance
amber backlit allows user to work in dusk environment also. Industrial Purpose
Environmental Specifications
Technical Details IT-250G
Operating Temperature -00C to 500 C
500V 25GΩ
Safety and Standards (CE Certifications)
1000V 50GΩ ± (5% + 5)
Safety and Standards (CE Certifications)
2500V 125GΩ Measurement Category : CAT IV (600V) Reinforced insulation
Continuity
Accessories
Range Accuracy Overload Protection
Standard
0-200Ω ±(3% + 10) 230V DC/AC rms for 30 sec
Test Lead set (3 mtr. Long shrouded banana with
Buzzer will sound < 20Ω approx.
crocodile clip)
Open circuit voltage on continuity range is 8V approx. Red lead for +ve terminal 1 No.
Black lead for ‐ve terminal 1 No.
Short Circuit current is 100mA approx. on Continuity range w.r.t
Green lead for GUARD terminal 1 No.
GUARD/COM terminal (Battery should be in a full charged condition).
Instruction Manual 1 No.
General Specification Calibration Certificate 1 No.
Carrying Bag 1 No.
Insulation Resistance Measurement Digital & Analog (Bar Graph) indication
Dimensions 230 mm(H) X 165 mm(W) X 95 mm(L). Test Lead set (10 mtr. Long shrouded banana with
Weight 1.5 Kg approx. (without accessories) crocodile clip) 1 No.
Red Lead for +ve terminal. 1 No.
Default Test on time 30 sec.
Black Lead for ‐ve terminal 1 No.
Selectable test time 1 sec. to 99 minutes. Green Lead for GUARD terminal
HV ON Indication Visual & Audible. Test Lead set 1 meter long with one end pointed tip &
another with 4mm shrouded banana.
Data Storage functions 1000 readings.
(For continuity range)
Data Recall function.
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Test & Measurement - IT-250G Spot 17
Accuracy
Features
Multi-featured single box design
Wide IR range up to 6GΩ, suitable for all LT applications
Selectable Voltage Facility 50, 100, 250, 500 & 1000V
Maximum test current of 1mA
Industrial Grade True RMS Multimeter functions
Voltage Measurement up to 1OOOV AC/DC
Dual Display LCD with Amber backlit
Auto Power Off Facility, Reading Hold / Lock, Min/Max,
FLT ( Filter )
Bluetooth enabled for Motware Mobile App
Mulitimete
r + IR Test
er
Connected to Cloud
MIRT-61
1KV Digital Multimeter Insulation Tester
CAT IV IP Applications
Ideal for Insulation Resistance Measurement during
1000V 54
maintenance for electrical equipments (Motors,
The Motwane's multipurpose tester model MIRT-61 is a versatile, Transformers, Machines, Switchgears etc.)
battery operated Digital Insulation Tester with true RMS industrial Electrical Wire/Cables for Distribution Networks
grade multimeter features, best suited for industrial preventive Control Panels
maintenance With test voltage range up to 1KV, highest insulation Electrical Contractors
Industrial, Commercial & Residential Installations
resistance range of 6GΩ and multi-featured function of RMS
Railways applications & Telecom applications
multimeter (i.e. AC/DC 1OOOV); makes it a superior offering for the
industry and service segments. It is designed predominantly for low
voltage insulation resistance testing in maintenance and services,
which involves the applications like Cables/Wires, Rotating Machines,
LT transformers, Switchgears and Industrial installations etc. It is
designed to suit the extreme environment conditions. Save your
operating cost and test more with this single box design rather than
buying two different products.
Overload Protection
Technical Details MIRT61
Fuse protection for 'mA' Input Terminal
0.8A/250V fast blow type,
Ceramic fuse
General
Safety CE Certifications
Display 6000 counts, LCD with amber backlit
Directives for CE Certification: LVD: 2006/95/EC,
Polarity Automatic
EMC: 2004/104/EC.
Display Update Rate 3 Times per second nominal
Measurement Category: CAT IV (1000V) Reinforced insulation.
DCV, ACV, Resistance, Capacitance, Relevant Standard (S): EN61010-1, EN61326-1
Ranges
Frequency, AC/DC Current, IRT
IP Rating (dust & water protection) : IP 54.
Auto Power Off After 10 mins Test lead set Red & Black one end with shrouded
Range 600Ω- 60MΩ (0.1Ω to 10KΩ resolution ) Test lead Green, one end with shrouded banana 4 mm
Continuity Test
Resolution 0.01Hz
Accuracy ± (0.1%+3)
Overload Protection 1000V DC/AC rms
Environmental
Operating Temperature 0°C to 50°C
to 40°C,Non-condensing
Test & Measurement - MIRT61 20
1050V
1 600mV 0.1mV 600.0mV DC +(0.9%+3) N/A DC/AC rms
0.8A/250V fast
1 600mA 0.1mA 600.0 mA +(1%+5) +(1.2%+5) blow type ceramic
fuse
Insulation Test
Output Range Resistance Accuracy
Resolution Test Current
Voltage (Auto Ranging only) +(% of rdg + Digits)
50 V 1 mA approx@
30 to 300 kO 1 kO +(3% + 5 counts)
+(10%+5) 50 kO
0.30 to 3.00 MO 0.01 MO
3.0 to 30.0 MO 0.1 MO
30 to 300 MO 1 MO
100 V 1 mA approx@
60 to 600 kO 1 kO +(3% + 5 counts)
+(10%+5) 100 kO
0.60 to 6.00 MO 0.01 MO
6.0 to 60.0 MO 0.1 MO
60 to 600 MO 1 MO
250 V 1 mA approx@
0.15MO to 1.50 MO 0.01 MO +(1.5% + 5 counts)
+(10%+5) 250 kO
1.5to 15.0 MO 0.1 MO
15 to 150 MO 1 MO
0.15 to 1.50 GO 0.01 GO
500 V 1 mA approx@
0.30MO to 3.00 MO 0.01 MO +(1.5% + 5 counts)
+(10%+5) 500 kO
3.0 to 30.0 MO 0.1 MO
30 to 300 MO 1 MO
0.30 to 3.00 GO 0.01 GO
1000 V 1 mA approx@
0.60MO to 6.00 MO 0.01 MO +(10% + 3 counts)
+(10%+5) 1MO
6.0 to 60.0 MO 0.1 MO
60 to 600 MO 1 MO
0.60 to 6.00 GO 0.01GO
Test & Measurement - MIRT61 21
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Smart
Go-No-Go Test Facility.
Pre selectable Timer Facility.
Mains Eliminator.
Selectable Voltage Facility 50, 100, 250, 500 & 1000V.
Auto Ranging Measurement from 10KΩ to 2GΩ - wide range
Live Circuit Detection up to 600V AC/DC.
Low Resistance Measurement up to 100Ω with continuity testing.
Temporary Storage of 10 readings.
User Selectable Backlit to measurement in dark environment.
Low Battery Indication.
Auto Power Off Facility.
Blown Fuse Indication.
Safe
CE mark conforming to latest EN 61010-1:2010.
EN 61326-1:2005, CAT IV 600V, IP54 protection.
Overload protection 1200V for all ranges.
Guard Terminal to minimize surface leakage.
Strong
i-12 Robust and Rugged Polycarbonate casing.
1KV Battery Operated Digital Insulation Resistance
Power
Technical Details i-12
Battery : 6 X 1.5V cells IEC LR6 Alkaline
is necessary.)
Environmental Insulation
Storage Temp. 0
-25 C to 65 C 0
Continuity Test
0 - 9.99 Ω 0.01 Ω ± (3% ± 2)
Current 100mA
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM - 10 24
Features
Test Current 10A, 1A, 100mA & 10mA & Resistance
up to 2000Ω
Resolution of 0.1μΩ with +0.2% Accuracy
High Open Circuit Voltage for quick stabilization
Dual Channel Resistance Measurement
Heat Run Test Facility
OLTC Test Facility
Auto Discharge
Internal Memory for 100 test results
USB interface with software for Report Generation
XWRM - 10
Transformer Winding Resistance Meter
CAT IV IP Applications
600V 54 XWRM-10 is perfectly suitable for measurements of cold and
hot winding resistances of Transformer winding. The
XWRM-10 is a dual channel 10A rated, transformer winding resistance instrument is designed for testing of power transformers as
meter designed for accurate & fast measurement of highly inductive well as distribution transformer. Trending of data can reveal
loads such as Transformers, Reactors & HT Motors etc. The instrument vital information about deterioration, incipient faults in tap
has one current channel and two resistance channels and the changer and enables user to take informed decision
selectable smooth DC test current useful to test windings with regarding maintenance.
different ratings. The instrument provides a large open circuit voltage
XWRM-10 is useful to the following segments:
of 42 Volts, for fast charging of the highly inductive windings of
transformers, to provide stable resistance values in minimum time. Power and Distribution Transformer
The XWRM-10 is intended to replace a complex bridge set up with a Motor and Generator
single compact instrument. The instrument is well protected against Heat Run Test
the inductive kickbacks offered by the inductive windings
Environmental
Technical Details XWRM-10
Operating Temperature -00C to 550 C
Technical Specifications
Power Supply 115/230VAC,50/60 Hz
Physical Specifications
Dimensions 520mm(L) x 425mm(W) x 230mm(D)
Test Current 10A, 1A, 100mA & 10mA
Weight 11 Kg (Approx)
Open Circuit Test Voltage 42 VDC
Burden 420VA
Accuracy +(0.2% of rdg. + 5counts) Data Transfer Real Time Data Transfer
P 2m Ω 0.1uΩ 1.9999mΩ
PC Interface USB
CE Certification
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Features
Test Current : 10A, 5A, 1A, 100mA & 10mA
Resolution of 0.1μΩ with +0.1% Accuracy
3 independent resistance measuring channels
Auto Range Facility
Heat Run Test Facility
48V Open Circuit Voltage for stable readings
Demagnetization Test Facility
OLTC dynamic test with Graph : Time vs Current
In-built Thermal Printer & Memory
Bluetooth enabled for Motware Mobile App
Temperature Measurement & Correction
Emergency Stop Switch
Connected to Cloud
XWRM-10A
Transformer Winding Resistance Meter
Test Current
Storage Temperature -10°C to 60°C
10A, 5A, 1A, 100mA & 10mA 95% RH, Non condensing
Humidity
Open Circuit Test Voltage 48 VDC
10 Kg (Approx)
Accuracy +(0.1% of rdg. + 5 counts) Weight
Analytic Software
Range Maximum
Resolution
Test Current Display Type Windows based analytical software
(Ω) (Ω)
(Ω)
Data Transfer Real time data transfer
10A 5A 1A 100mA 10mA Features Online data acquisition
Graph plotting for heat run test
P 2m Ω 0.1uΩ 1.9999mΩ
& OLTC dynamic test
P P 20m Ω 1uΩ 19.999mΩ Remote operation
Test report generation
P P P 200mΩ 10u Ω 199.99mΩ
P P P P 2Ω 0.1mΩ 1.9999 Ω
Accessories
P P P 20 Ω 1m Ω 19.999 Ω
Standard
P P 200Ω 10mΩ 199.99 Ω
15 meter measuring test lead set with alligator clamp
P 2000Ω 0.1 Ω 1999.9 Ω
Mains Power cord
P 4m Ω 4µΩ 4.0000m Ω
Short links - 2Nos.
P 40mΩ 1µ Ω 40.000m Ω Earthing lead
User Manual
P 400m Ω 10µΩ 400.00m Ω
Calibration Certificate
P 4Ω 0.1mΩ 4.0000m Ω
Carry Case for Test leads
Optional
PC Interface USB
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM - 10A 28
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Test Current : 25A, 10A, 5A, 1A, 100mA & 10mA
Resolution of 0.1μΩ with + 0.1% Accuracy
3 independent channels for resistance measuring
Auto Range Facility
Heat Run Test Facility
60V High Open Circuit Voltage for stable readings
Demagnetization Facility
OLTC Dynamic Resistance Test with Graph: Time vs Current
Inbuilt Thermal Printer & Memory
Bluetooth enabled for Motware Mobile App
Temperature Measurement & Correction
Emergency Stop Switch
Connected to Cloud
XWRM-25A
Winding Resistance Meter
Display LCD
CE Certification
Burden 1500 W
Environmental
Resistance Measurement Range
Operating Temperature 0°C to 55°C
Accuracy +(0.1% of rdg. + 5 counts)
Storage Temperature -10°C to 60°C
15 Kg (Approx)
P 2m Ω 0.1uΩ 1.9999mΩ Weight
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Transformer Testing Instruments - XWRM-25A 31
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Test Voltage : 10V, 40V, 100V
Measure Turns Ratio, Voltage Ratio & Ratio Error
Measure Phase Deviation & Excitation Current
Auto Detection of Transformer Vector Group
Quick set up with intuitive guide
Inbuilt Printer with Memory for 500 test results
Bluetooth enabled for Motware Mobile App
Connected to Cloud
XTRM-3
Transformer Turns Ratio Meter
Safety Features
Technical Details XTRM-3
Safety / EMC in accordance with EN 61010-1, EN 61326-1
CE Certified
Ingress Protection IP54 / CAT III 600V
Emergency Stop
Technical Specifications
Power Supply 115V/230V AC, 50/60 Hz Full Windows Compatible Software
Measurement ratio 0.8 : 10000 Software is fully compatible with Microsoft
Data Downloading
Optional
Display LCD
PC interface USB
Environmental Specifications
Operating Temperature 00C to 400C
Physical Specifications
Dimensions 502mm(H) x 401mm(W) x 188 mm(L)
Weigh 15 kg (Approx)
Transformer Testing Instruments - XTRM-3 34
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Dissipation Factor , Volume Resistivity, Dielectric Constant
(Permittivity), Watt Loss
Inbuilt Oil Heating Chamber with precise temperature control
Test Cell according to IEC 60247
Preprogrammed & Customized Test Sequences
Inbuilt Thermal Printer
Internal Memory for 250 Test
USB Interface
Portable Calibrator
Oil Auto Drain Facility
Auto Sequence Test
Bluetooth enabled for Motware Mobile App
CAT III IP
Applications
600V 54 The dissipation factor indicates the dielectric loss of the
liquid and thus it's dielectric heating. The dissipation factor
test is widely used as an acceptance and preventive
Motwane's MOTR is a microprocessor-based compact designed for
maintenance test for insulating oil. The dissipation factor of
precise measurement of the dissipation factor and volume resistivity
new oil should not exceed 0.05 % and the dissipation factor
of insulating oils. MOTR is built in a single unit and on boarded with
can gradually increase in service to a value as high as 0.5%,
international test standards for automatic measurement of all
i n m o st c a s e s , i n d i c a t i n g d e te r i o ra t i o n a n d /o r
parameters and also available with customized test sequences to
contamination with moisture, carbon, varnish, glyptal,
conduct tests as per the user's requirement. The test cell is designed
sodium soaps, or deterioration products.
as per IEC 60247 with precise control for measuring dissipation factor
and resistivity at 27°C & 90°C. MOTR also has an auto drain facility. It is Used Oil having a dissipation factor of less than 0.5% is
provided with internal memory & printer for on-field reports and also usually considered satisfactory for service and with
has a USB interface available for data transfer. The calibrator with dissipation factor between 0.5% and 2% should be
standard dissipation factor & resistivity ranges are available for considered as being in doubtful and further investigation
validating the performance of MOTR. recommended and in excess of 2.0 % may be an
operational hazard. It should be reconditioned or replaced.
MOTR has a Bluetooth connectivity module with Motware mobile app
for remote access of testing data & storage in the cloud for further Useful for measuring the quality of insulating oil, used in
analysis & record purposes. electrical apparatuses like:
Heater
Technical Details MOTR
Temperature Range 20°C - 150°C
Accuracy +0.5°C
Resolution 0.1°C
Accuracy +1%
Resolution 1 X 10-5
Operating Temperature -100C to 500C, 90% non condensing
Accuracy +1% of rdg + 0.0001 (1 X 10-4)
Safety Standards IEC61010-1, IEC61326-1
Accessories
Dielectric Loss 0 -10.0 watts Standard
Test Cell
Cell Constant 620 Nominal
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Fully Automatic Microprocessor based
Pre-programmed International Test Standards
Customized Test Sequences
Voltage Slew Monitoring: Real Breakdown Monitoring (RBM)
Upgraded Sequence as per IEC60156-2018
Suitable to test Mineral, Ester & Synthetic Oil
Internal Memory up to 100 Test
USB Interface
Inbuilt Thermal Printer
Voltage Checker for onsite Calibration
Bluetooth enabled for Motware Mobile App
Connected to Cloud
OTS-60A/80A/100A
Automatic Oil Insulating Test Set
Applications
Transformer oil is used as insulating medium in transformer,
switchgear and other electrical apparatuses and it also acts
as a coolant which dissipates (or to dissipate) heat of the
OTS-A series is a fully automatic microprocessor-based Oil BDV
transformer. In addition to these, insulating oil serves other
Tester designed with advanced technologies to measure the
purposes like, it helps to preserve the core and winding as
electrical breakdown strength of insulating oil. OTS-A has a quick
these are fully immersed inside oil and another important
sensing ability to measure accurate breakdown voltage. OTS-A series
purpose of Insulating oil is, it prevents direct contact of
is equipped with national & international standards for test sequences
atmospheric oxygen with cellulose made of paper insulation
and it also has has user-friendly customized test sequences. The large
used in windings, which is susceptible to oxidation. When
LCD display with keypad provides easy operation. It is provided with
insulating oil deteriorates due to aging / contamination
internal memory for 100 data storage & inbuilt thermal printer for the
which leads to catastrophic event due to flashover in
onsite report. As for safety, the OTS-A series has open ground
insulation. The voltage withstands capability of oil which
detection feature to avoid damage. The molded oil test vessel is
often is reduced ( which often reduces) due to
suitable to test Mineral, Easter & Synthetic Oil and it is provided with
contamination like dirt, water ingress and foreign particles.
an adjustable electrode gap setting to conduct the test as per
standards. The portable voltage checker is useful for onsite
The Motwane's OTS-A series useful for Oil Testing
calibration verification.
in the following equipments:
OTS-A series has a Bluetooth connectivity module with Motware
mobile app for remote access of testing data & storage in the cloud Power and Distribution Transformer
for further analysis & record purposes. Bushing
Instrument Transformer
Switchgear
Capacitors
Transformer Testing Instruments - OTS 39
Accessories
Technical Details OTS-60A/80A/100A
Standard
UNE 21, BS5730A, BS 148, BS5874, VDE 0370, NFC 27, CE1344,
Iterations - 24
PC Interface USB
Protection
Zero Start and HT Cover Open Interlock
Overload Protection
Weight 39 Kg (Approx)
Transformer Testing Instruments - OTS 40
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Motorized Operation with 2kV/s ramp rate
Safety Door & Zero Start Interlock
Digital Display with optional Hold Facility till Variac
goes zero position
Voltage Checker for onsite checking (optional)
Earth Open Interlock
Bluetooth enabled for Motware Mobile App
Connected to Cloud
OTS-60DS/80DS/100DS
Digital Oil Insulation Test Set
Applications
Transformer oil is used as insulating medium in transformer,
switchgear and other electrical apparatuses and it also acts
Motwane offers a wide range of Oil Breakdown Voltage test kits to as coolant to dissipate heat of the transformer. In addition to
check dielectric strength of insulating oil used in Transformers, these, Insulating Oil serves other purposes like it helps to
Capacitors, Switchgears and Instrument Transformer for safe preserve the core and winding as these are fully immersed
operation and maintenance. OTS-DS series Series is meeting to inside oil and another important purpose of insulating oil is,
national & international standards for conducting BDV Test. It is also it prevents direct contact of atmospheric oxygen with
facilitated with ZZero Start Interlock and Earth Open Interlock for cellulose made of paper insulation used in windings, which is
safety and avoid hazards. Also equipped with LED (Digital Display) susceptible to oxidation. When insulating oil deteriorates
along with Hold Facility. Designed with unmatched quality and due to aging / contamination which leads to catastrophic
improved reliability and safety having earth & zero start, safety door event due to flash over in insulation. The voltage withstands
interlock ensuring high degree of protection. OTS comes with two capability of oil which often is reduced (which often
variants models- OTS-A series - a pre-programmed fully Automatic reduces) to contamination like dirt, water ingress and
Oil BDV kit and OTS-DS Series - Motorized with Digital Display. foreign particles.
Accessories
Technical Details OTS-60DS/80DS/100DS
Standard
Overload Protection
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Motorized-cum-Manual Operation.
Safety Interlock Door
Analog Voltmeter with Memory Effect.
Earth Open Interlock
Oil Test Set meeting standards IS6792: 1992
Continuous variable Output Voltages
ANALOG OTS-60/80/100
Analog Oil Insulation Test Set
0 - 60kV
Standards IS6792
Technical Specification
Display
Voltage Range
10kVAC - 90kVAC
Resolution
0.1 kV
VC-100
Voltage Calibrator For Oil Test Set Operating Temperature
00C to +550C
The VC-100 is a calibration meter suitable for verifying the calibration
of oil test sets. The high voltage output is measured between both
terminals using the VC 100 meter. The meter will enable the high Storage Temperature
voltage output to be checked, traceable to national standards. The -100C to 700C
VC 100 meter fits in the oil test set chamber in place of oil test vessel
in all models of OTS-A series and OTS-DS series for calibration. The
voltage indication is viewed on a digital display and voltage range Humidity
10KV AC - 90KV AC. Also high voltage attenuator chain moulded in
<90% non-condernsing
epoxy avoids moisture absorption or leakage. The meter is supplied
with protective carrying case.
Dimensions
Features 258 mm (L) x 180 mm (B) x 116 mm (H) Approx.
Measures relative output voltage between both
terminals Oil Dielectric Test Set
Direct Digital Display read out in kV. True RMS Weight
Features
100A & 200A Pulsating DC selectable Test Current
Resistance Range : 0.1μΩ to 20mΩ, Autoranging
Direct mV Drop Reading
Built in Thermal Printer
Internal Memory of 500 test results
Mains and Battery Operated
USB Interface for Data Transfer
LED Indication for Mains/Battery/LOBAT
Calibration Due Indicator
Dual Grounding Facility
Conformity IP54, CE
Bluetooth enabled for Motware Mobile App
Connected to Cloud
PCRM200S
Contact Resistance Meter
CAT II IP Applications
300 54 Stationary and moving contacts are built from alloys that are
formulated to endure the stresses of electrical arcing.
The Motwane's Digital Contact Resistance Meter, Model However, if contacts are not maintained on a regular basis,
PCRM-200S is specially designed to measure extremely low their electrical resistance due to repeated arcing builds up,
resistances in micro ohm. The Instrument is based on Kelvin 4- wire resulting in a significant decrease in the contact's ability to
connection method for measurement of low resistance. User carry current and increase in resistance. Excessive corrosion
selectable current injection is 100A/200A. PCRM 200S has large LCD of contacts is detrimental to the breaker performance.
with backlight and display real time test information like injected Hence to check contacts is to apply DC and measure the
current with measured resistance value & voltage drop. User friendly contact resistance or voltage drop across the closed
instrument and it comes with heavy duty cable with clamps for contacts. The use of a higher current value gives more
accurate measurement and accessories are housed in easy reliable results than using lower current values. The
transportation case. Advance Windows based software is provided resistance value is usually measured in micro ohms (µΩ).
for data downloading, analysis and report generation. Internal
PCRM-200S is specially used to measure static contact
memory of 199 records is provided for onsite data storage and inbuilt
resistance of LV, HV, EHV circuit breaker contacts installed in
thermal printer to print the test results at the field.
energised switchyards. High accuracy and repeatability
PCRM 200S has dual ground technique to test circuit breaker with makes it a reliable tool for Quality Assurance and easy
both side grounded, which is safer to conduct test in substation. operation makes it a very handy tool for quick maintenance
checks in various industries
PCRM 200S has Bluetooth connectivity module with Motware mobile
app for remote access of testing data & storage in the cloud for Typical resistance measurement applications are
further analysis & record purpose. Circuit Breaker contact resistance
Bus bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-200S 48
Software Details
Technical Details PCRM 200S
Type Windows based software
Interface USB
Power Supply
Mains 115V-230V, 50Hz / 60Hz Single phase AC supply
Environmental
Operating Temperature 0°C to 55°C.
Safety Standards
Safety According to EN 61010 - 1
IP Rating IP 54
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - PCRM-200S 49
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
100A Pulsating DC Test Current
Resistance Range : 0.1μΩ to 2mΩ Autoranging
Direct mV Drop Reading
Built in Thermal Printer
Internal Memory of 500 test results
Mains and Battery Operated
USB Interface for Data Transfer
LED Indication for Mains/Battery/LOBAT
Calibration Due Indicator
Dual Grounding Facility
Conformity IP54, CE
Bluetooth enabled for Motware Mobile App
Connected to Cloud
PCRM 100S
Contact Resistance Meter
CAT II IP Applications
300 54 Stationary and moving contacts are built from alloys that are
formulated to endure the stresses of electrical arcing.
The Motwane's Digital Contact Resistance Meter, model However, if contacts are not maintained on a regular basis,
PCRM-100S is specially designed to measure extremely low their electrical resistance due to repeated arcing builds up,
resistances in micro ohm. The instrument is based on Kelvin 4- wire resulting in a significant decrease in the contact's ability to
connection method for measurement of low resistance. Selectable carry current and increase in resistance. Excessive corrosion
current injection is 100A. PCRM 100S has a large LCD with backlight of contacts is detrimental to the breaker performance.
and display real time test information like injected current with Hence to check contacts, apply DC and measure the contact
measured resistance value & voltage drop. It is a user-friendly resistance or voltage drop across the closed contacts. The
instrument and it's comes with heavy duty cable with clamps for use of a higher current value gives more reliable results than
accurate measurement and accessories are housed in easy using lower current values. The resistance value is usually
transportation case. Advance Windows based software is provided measured in micro ohms (μΩ).
for data downloading, analysis and report generation. Internal
PCRM-100S is specially used to measure static contact
memory of 99 records is provided for onsite data storage and inbuilt
resistance of LV, HV, EHV circuit breaker contacts installed in
thermal printer to print the test results at the field.
energised switchyards. High accuracy and repeatability
PCRM 100S has dual ground technique to test circuit breaker with makes it a reliable tool for Quality Assurance and easy
both side grounded, which is safer to conduct test in substation. operation makes it a very handy tool for quick maintenance
checks in various industries.
PCRM 100S has Bluetooth connectivity module with Motware mobile
app for remote access of testing data & storage in the cloud for Typical resistance measurement applications are
further analysis & record purpose. Circuit Breaker contact resistance
Bus Bar joints
Isolator contacts
Weld joints
Bond resistance
Contact Resistance/Low Resistance Meter - PCRM-100S 51
Software Details
Technical Details PCRM 100S
Type Windows based software
Interface USB
2000 µΩ with 1 µΩ
Environmental
Operating Temperature 0°C to 55°C.
Safety Standards
Safety According to EN 61010 - 1
IP Rating IP 54
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - PCRM-100S 52
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
100A True DC Test Current
Resistance Range : 0.1µΩ to 2mΩ
Direct mV Drop Reading
Internal Memory of 100 test
Dual Grounding Facility
Light weight & Portable
Rust Removing C Clamp
PCRM 100SM
Contact Resistance Meter
Applications
Stationary and moving contacts are built from alloys that
are formulated to endure the stresses of electrical arcing.
However, if contacts are not maintained on a regular basis,
Motwane's PCRM-100SM is True DC Contact resistance meter
their electrical resistance due to repeated arcing builds up,
designed for accurate and reliable result at a very reasonable cost.
resulting in a significant decrease in the contact's ability to
The instrument is based on Kelvin 4- wire connection method for
carry current and increase in resistance. Excessive
measurement of low resistance. PCRM 100SM has true 100A DC test
corrosion of contacts is detrimental to the breaker
current suitable for testing Circuit Breaker, Bus Bar, Isolator and Cable
performance. Hence to check contacts is to apply DC and
etc. PCRM 100SM has dual ground feature considering safety of
measure the contact resistance or voltage drop across the
operator and equipment. PCRM100SM is very light weight and
closed contacts. The use of a higher current value gives
portable with heavy duty test leads with C clamp and crocodile clips
more reliable results than using lower current values. The
to suit different applications.
resistance value is usually measured in micro ohms ( µΩ ).
Accessories
Technical Details PCRM 100SM
Standard
Memory Storage 100 Test Heavy duty crocodile clip 32mm Jaw Size.
15 meter Cable (heavy crocodile clip 32mm Jaw opening)
Physical Specifications
Dimensions 320 mm(D) x 435 mm(W) x 188 mm(L)
Weight 7 Kg Approx
Power Supply
Environmental
Operating Temperature 0°C to 50°C.
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - CRM100A 55
Features
Continuously selectable Current In steps of 10, 20,
50 & 100A resp.
Digital Resistance Reading from 0.1μΩ to 20mΩ.
Simultaneous Display of Test Current, Resistance
Minimum Resolution of 0.1μΩ
Accuracy + (0.5% +5 digits)
3 1 ⁄ 2- digit readings for resistance.
Custom built backlit LCD with sealed soft touch
membrane keypad.
Data Exchange to PC through USB Interface.
Built-in Memory to store up to 99 test results.
Test 'ON' indicator with LED & beep, provided to signify
the flow of Direct Current DUT.
CRM 100A
Contact Resistance Meter
Applications
Stationary and moving contacts are built from alloys that
are formulated to endure the stresses of electrical arcing.
The Motwane's Contact Resistance Meter- CRM 100A is a digital However, if contacts are not maintained on a regular basis,
micro ohmmeter, designed to measure extremely low resistance. The their electrical resistance due to repeated arcing builds up,
instrument is based on the proven 4-wire measurement method for resulting in a significant decrease in the contact's ability to
low resistances to eliminate the effect of lead resistance of two wire carry current and increase in resistance. Excessive corrosion
method. The instrument is designed to replace complex bridge set up of contacts is detrimental to the breaker performance.
with a single compact unit. The DC current injection in continuously Hence to check contact, apply DC and measure the contact
adjustable between 10A to 100A. The testing information is displayed resistance or voltage drop across the closed contacts. The
on large LCD with backlit, real time data is displayed during the test use of a higher current value gives more reliable results than
using lower current values. The resistance value is usually
ON condition. The instrument gives a high resolution of 0.1 μΩ on 200
measured in micro ohms (μΩ).
μΩ resistance range.
CRM 100A has a large application for direct and indirect
The instrument is easy to operate and user friendly. Accessories are
measurements in various industries and manufacturing
rugged and come with heavy duty clips for better grip on test object.
facilities. High accuracy makes it a reliable tool for Quality
The kit and accessories are housed in a trolley mounted casing for
Assurance and easy operation makes it a very handy tool for
easy transportation. Advanced Dot Net based software is provided
quick maintenance checks for process industries.
for data downloading, analysis and report generation. The instrument
can be operated through software from a remote location. Internal
memory is provided for onsite data storage. Typical resistance measurement applications are
Safety Standards
Technical Details CRM 100A
Safety : According to EN 61010 - 1
Power Supply
Accessories
Standard
Input Power 230V+ 10%, 50 Hz, 1 Phase
Output lead Set 4 X 5m
DC Test Current 10A, 20A, 50A & 100A
Mains Power Cord
Accuracy 5%
Mains Protection fuse 5A
Resolutions 0.1 A User Manual
Software CD
Resistance Measurement
USB Cord
Resistance Ranges 200µΩ 2m Ω 20mΩ
Operation Time
Continuous Operation up to 50A
Warning
Audio Visual Indication for Test ON Operation
Environment
Operating Temperature 0°C to 55°C
Physical
Weight 12 Kg (Approx)
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Features
4.3” Color TFT display with backlit
Resolution 0.1 μΩ on 2 mΩ range
Best Measurement Accuracy of 0.03 %
Mains cum Battery operated.
High measurement current (10A) for faster settling of
measured values on low resistance.
True 4 wire resistance measuring technique
Pulse Mode, Auto Hold Operation.
Bluetooth interface and cloud connectivity through
Motware app
Inbuilt thermal paper printer
Low Battery indication to prevent deep discharge of
internal recharging battery.
Temperature Measurement & Correction
Connected to Cloud
LR 2065S
10 (AMPS CURRENT)
Safety
Technical Details LR 2065S Measurement Category: CAT II (1000V)/CAT III (600V)
Reinforced insulation
Relevant Standard Specifications: Safety According to
EN 61010-1,EMC According to EN 61326-1
Optional
Power
Mains Power Supply Mains Input Voltage 115/230 Volt AC, 50/60Hz
Electrical Specifications
At 25°C +3°C 55% RH+10% Temp. Co. 150 ppm/°C
Resistance Range
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Micro Ohm Metre - LR 2065S 59
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Back-EMF Protection
Heat Run Test
Best Measurement Accuracy of 0.05 %
Bluetooth Interface And Cloud Connectivity Through
Motware App
The Inbuilt Thermal Paper Printer
Temperature Measurement & Temperature Correction
Feature.
4¼ Digit Large And Clear Display
Accurate & Stable Readings
Pc Interfacing With Software
4 Wire Measurement Method
Sealed Soft Touch Membrane Keypad
Temperature Measurement & Correction
Connected to Cloud
LR 2045S
Micro Ohm Meter
Applications
Hot & Cold Winding Resistance Measurement of Motors,
The Motwane LR 2045S capable of measuring low resistance with 1
Generators, Alternators, and Transformers.
micro-ohm resolution. It employs the proven 4-wire (4W)
Contact Resistance Measurement of Fuses and
measurement where fixed DC current is supplied to DUT and voltage
Miniature Circuit Breakers.
drop across the DUT is measured and displayed as proportional
Resistance Measurement of Cables & Wires.
resistance reading. The meter is able to deliver guaranteed stable
readings on inductive as well as resistive loads.
Contact Resistance/Low Resistance Meter - LR 2045 61
Safety
Technical Details LR 2045S Measurement Category: CAT II (1000V)/CAT III (600V)
Reinforced insulation
Relevant Standard Specifications: Safety According to
EN 61010-1, EMC According to EN 61326-1
Temperature Channel 1
Physical Specifications:
Printer Built in Thermal Printer
Dimensions : 360.68 mm (L) X 289.56 mm (W) X 165.1 mm (H)
PC Interface USB Net Weight : 6.0kg (Approx)
Accessories
Indications
Standard
4.3” Color TFT with backlit or range and Ω/mΩ indications.
Test Lead set 10meter : 1 Set.
LED indication for operation and pulse mode. Mains Power Cord : 1 No.
Mains Protected Fuse : 1 No.
Over range indication: Blinking zero display.
Thermal Paper roll : 1 No.
Under Range Indication: All Display shows zero. (Not blinking) Instruction Manual : 1 No.
Calibration Certificate : 1 No.
Optional
Technical Specifications :
USB cable : 1 No.
MAX ACCURACY Temperature measurement probe : 1 No.
Range Resolution
CURRENT ± (%RDG + DIGITS)
Note : Accuracies are valid from 1/10th of the range to FS of range & valid
50/60Hz
Environmental Specifications:
(Non Condensing)
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Resistance/Low Resistance Meter - LR 2045 62
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Lightweight and Portable
Testing up to 6 Main + 6 PIR
High resolution of 0.05ms
Programmable delays in OC, CO cycle
Internal Memory for 200 Results
Calibration Due Indicator
Comes with Inbuilt Battery and
Thermal Printer
MCBT-P
Circuit Breaker Timer Kit
Applications
Circuit Breaker Testing (AIS, VCB) Gas Insulated
Switchgear Testing Drive Switch/Earth Switch Testing
MCBT-P is a microprocessor-based second generation circuit breaker Isolator /Disconnect or Testing
time interval meter. It measures the Closing, Opening, CO and OC
Measurements
times of various types of circuit breakers up to 400kV. The equipment
is capable of testing up to 6 Main and 6 PIR contacts at a time under Main Contact Timing
hostile EHV switch yard conditions. MCBT-P has a compact and PIR Contact Timing
lightweight construction. This makes it ideal for reliable Number of Bounces
measurements during periodic maintenance and inspection of circuit Bounce Duration
breakers. Contact Mismatch
Protection Testing - MCBT-P 64
Sampling Speed 20kC, 10C, 5kC, 2C, 1kC, 500Hz and 100Hz selectable
Plot Length 0 - 1000 mSec @ 20kHz, 0 - 5000 Sec @ 2kHz 0 - 50000 mSec @ 500Hz,
Breaker Control Two solid state contacts rated at 35A, 300V AC/DC for breaker operation
Trigger Options Open, Close, C-O, O-C (Delay between operations selectable)
Special Cycle Duty Cycle "O-0.3Sec-CO-3Min-Co" Operation Only with Fixed Delay)
Keypad 5 Keys
Environment 00C to 500C, 95% RH (non-condensing), Electrical noise normally found in charged HV switchyards
Weight 7 kg
IEC 1010-1 Safety requirements for electrical equipment for Measurement, control & laboratory use.
Type Test IEC 68-2/ IS 9000 Basic Environmental Testing Procedures covering shock, bump and vibration tests.
User Benefits
Simultaneous measurement of 6 Main and 6 PIR contacts i.e. 2 Main and 2 PIR per pole.
Easy to use with backlit LCD Display and a special purpose keypad.
Dual-powered with AC mains or through built-in Li-Ion battery with quick charging and long battery back-up.
Inbuilt Real-time clock which enables report printing with date and time stamp using an onboard thermal printer
Up to 200 results can be stored along with the date and time stamp on the internal memory.
User-friendly Windows software for downloading test results, performing trend analysis, and generating test reports.
Rugged and easy-to-connect test leads for timing measurement (15 meters) and breaker control (7 meters).
Accessories
Contact Timing Cable, 15m 3 Nos
Features
Tests all types of circuit breakers from LV to UHV up to
1200 kV in switchyard conditions.
Completely modular analyzer allowing the user to select
the configuration as per their specific requirements.
Timing measurements for up to 12 Main, 12 PIR, and 8
Auxiliary contacts.
Rotary and linear travel measurements
AC/DC coil and motor current measurements
Up to 6 channels for static and dynamic contact resistance
measurement of 100A rating each.
Mounted in a trolley with wheels for easy movement in
rough switchyard terrain.
MCBOA Puls software for pre-configuring test parameters
and sequences.
MCBOA Plus
Circuit Breaker Operational Analyzer
MCBOA Plus is a NextGen operational analyser that performs contact Coil & motor current analysis
travel, contact timing, coil and motor current, and static and dynamic MCBOA Plus records the current signature curves of the coils and
contact resistance measurements in live switchyard conditions. The motors during the breaker operation. Deviations from the
analyser is mounted in a specially designed trolley that allows it to be expected signature curves show possible electrical or
moved easily in the rough switchyard terrain. The analyser is supplied mechanical defects of the trip and close coils and incorrect
with MCBOA Plus PC software that allows pre-configuration of test coordination of the auxiliary contacts and release latches. The
parameters and test sequences that save you vital time in the analysis of motor currents shows the in-rush current, average
switchyard, thus minimising downtime. The software displays results current, and spring charging time. Spring charging time analysis
along with graphs and generates test reports. help in determining the condition of the spring mechanism.
Tests Performed
Static contact resistance test (CRM test)
Timing tests
MCBOA Plus tests the contact resistance of the closed
MCBOA Plus assesses the main contact and auxiliary contact timings.
switchgear to ensure that the load current flows with low losses.
This assessment is useful for measuring the contact bounces and non-
Sufficiently high contact resistance can cause substantial
simultaneity of contacts and helps in finding possible electrical or
heating and subsequent failure of the breaker contacts.
mechanical defects. It is possible to detect incorrect mechanical
adjustments and wear phenomena of the breaker by measuring the
differences between the fastest and slowest phases. Dynamic contact resistance test (DCRM test)
MCBOA Plus performs dynamic contact resistance measurement
Contact travel analysis (DCRM) analysis on the switchgear to measure the wear of the
MCBOA Plus makes use of special transducers to record the travel arcing contacts of SF6 MV, HV, and EHV breakers. Dynamic
signature curve of main contacts/rotating shafts during the breaker contact resistance measurement is important for assessing the
operation. Travel measurements assess the rate of displacement of contact condition after several fault trips on-site for finding out
the contact assembly. This assessment helps in understanding erosions, pitting, sluggishness, residual arcing tip length, etc.
whether the breaker contact operating mechanism is working without opening the interrupter. This cannot be detected by
appropriately. Deviations from the expected signature help finding performing static contact resistance measurements. The
possible mechanical defects of the main contacts, moving shafts, and measurement also helps to record the benchmark signature of
springs. The travel measurements also include measurement of the arcing contacts, which is used for studying the deterioration
velocity, insertion, contact gap, over-travel, and rebound. of arcing contact conditions over time.
Protection Testing - MCBOA Plus 67
Modules
CPU & Power Module Auxiliary Contact Modules
The CPU & Power Module communicates with a PC through either The Auxiliary Contact Module measures the status of the auxiliary
WiFi or Ethernet and controls the activity of all the remaining contacts, bounce, etc. A small current is injected through each
modules. In response to instructions given by the user, the PC sends channel using the common terminal which is sensed back and the
the data containing the command, sampling frequency, current status of the external contact to which the channel is wired is
range, travel settings, etc. that is required to control the remaining interpreted. Depending on the status of the contact, the module
modules. Once the command and other settings are transferred from provides digital data to the bus on the interface module. Each
the PC to this module, the data sampling process begins, and the timing channel is optically isolated from the other. The same
sampled data from each module are stored in the memory of the CPU module measures the Auxiliary contact timings of wet and dry
& Power Module. When the sampling operation is completed, the auxiliary contacts. Two Auxiliary Contact Modules are present in
collected data is sent to the PC for further evaluation. the default configuration of the system, each having four auxiliary
contact channels.
Travel Modules
The Travel Modules measure travel, contact speed, etc. Each
module has three isolated ADC channels running at 40 kHz and
with a 16-bit resolution. The module has programmable gains and
offsets to provide maximum amplification and conditioning to the
received signal. Additionally, it also has a built-in 5 V DC source for
exciting the transducers.
The MCBOA Plus is offered with 6 DCRM channel configurations. The MDCRM Plus Pole Unit is compact, lightweight, and can be
The MCBOA Plus performs DCRM by using the MDCRM Plus Pole easily carried by the technician while making connections to the
Unit accessory. The MDCRM Plus Pole Unit consists of an integrated breaker contacts. As it is directly mounted close to the breaker
current source and high-speed data acquisition hardware for contacts, the length of the test leads set is considerably shortened
continuous V and I measurement. It communicates with the allowing for a lightweight test leads set.
MCBOA Plus trolley over a robust wireless platform. All the
The MDCRM Plus Pole Unit runs on a LiPo battery. The LiPo battery
measurements performed by the MDCRM Plus Pole Unit are
is capable of delivering multiple shots in a single charge. At the end
communicated wirelessly back to the MCBOA Plus trolley located
of testing, the MDCRM Plus Pole Unit is simply placed back into the
at a safe distance away from the breaker. The acquired data are
MCBOA Plus trolley and can be charged through the trolley itself,
converted into a suitable format and displayed in the MCBOA Plus
eliminating the need for external chargers. Various protections
software.
from over charging and deep discharge have been implemented
for ensuring battery safety and a long battery life.
Transducers
MCBOA Plus is supplied along with custom-designed fixtures suitable for all types of circuit breakers manufactured by ABB, CG, L&T,
Schneider, Siemens, Toshiba, and all others. Our test fixture can be customised for mounting circuit breakers of any design.
The transducer is used for measuring the contact travel and all other breaker parameters that are derived from travel measurements, such as
contact speed or velocity, contact gap, snatch gap, wipe gap, bounces, bounce duration, rebound, rebound duration, over-travel, and over
travel duration. In the case of linear travel, the travel is measured in millimeters. However, in the case of rotary or angular travel, the travel is
measured in degrees.
For linear travel measurements, either a resistive or a more accurate laser transducer is used. While, for rotary travel measurements, either a
resistive transducer or an encoder is used.
Measurements
Snatch gap
Over travel
Rebound
Rebound duration
Transducer Types
Linear resistive
Rotary resistive
Rotary encoder
Linear laser
Protection Testing - MCBOA Plus 70
Modern and easy-to-use user interface with Windows 10 styling. Printing of results in a graphical format with test header and
calculation footer, on the external printer.
Multiple themes are available as per the user's preference.
Comparison of graphs of multiple operations for
Easy to access command buttons for performing regular tasks.
performance evaluation over some time.
Contacts configurable
Six solid state contacts rated at 35Amp/ 300V AC/DC for breaker operation
Breaker Control
(User configurable Close/Trip commands)
Trigger Options Open, Close, C-O, O-C, O-C-O, OCO-CO and Motor (delay between operations selectable)
Sampling Speed 40kC, 20kC, 10kC, 5kC, 2kC & 1kC selectable
Plot Length 2Sec at 40kC, 5Sec at 20kC, 10Sec at 10kC, 20Sec at 5kC, 40Sec at 2kC and 100Sec at 1kC
Graphical Results Test graph with detailed analysis of results over graph
Communication Ethernet port and Wi-Fi for communication between laptop and instrument
Environment 0 to 50 degrees C, 95% RH (non-condensing), electrical noise normally found in charged HV switchyards
Channel Details
Main Contact Timing 12
Auxiliary Timing 12
Travel 6
Breaker Control 6
Protection Testing - MCBOA Plus 72
Standard Accessories
Item* Length Item* Length
Auxiliary Contact Timing Cable 10 m Soft Carrying Case for Test Leads 1 No.
Mains Cord 3m
Optional Accessories
Channels Configuration Range Resolution Accuracy
DCRM + CRM Each for Resistance & test current 1000, 2000, 0.1 μΩ Value + 1%
4000, 8000
(6 channels) as per configuration ordered
Micro Ω
Configurable
Analog Inputs Optional for conditioned 10-300 V DC 10mV Value + 1%
300 V DC analog signal input
(6 channels)
Configurable
Analog Inputs Optional for conditioned 0-10 V DC 1mV Value + 0.5%
10 V DC analog signal input
(6 channels)
Configurable
Analog Inputs Optional for conditioned 4-20 mA 0.1mA Value + 0.5%
20 mA analog signal input
(6 channels)
Optional PIR
Optional for pre insertion 0-5 k Ω 1Ω Value + 0.5%
Value
resistor value measurement
(6 channels)
Item Quantity
Features
Connects to Circuit Breakers, Drives, and Earth Switch with
wear resistant test leads, having suitable connectors.
Selects pre-programmed setup parameters and pass / fail
limits through software.
Prints graphical results with user specified header and footer
on external printer.
Windows based MCBOA software allows configuring &
storing test setups, viewing reports, and analyzing and
handling graphical test data using a PC.
Automatic creation of folder structure on PC for storage of
test data.
Dynamic calculations with cursor movements for on-screen
analysis.
Test Certificate can be stored and printed as per the
manufacturer's format which enables user to compare with
factory test results.
All test data is stored in a database for archival and analysis.
MCBOA
Circuit Breaker Operational Analyser
Specifications
HS Code 90318000
Contact Timing Module Isolated channels for timings of 6 Main and 6 Dry Auxiliary contacts
Channels 12 channels
Channels 6 channels
Isolation 2kV between two channels and between channels and chassis
Solid State Relay contacts rated at 30A / 250V AC / DC for issuing commands to the breaker.
Switching Within 50 µs
3 channels for Closing / Tripping speed and mechanism travel of each pole.
Breaker
Contact Timings
Contact Bounce
Non-simultaneity of contacts
Motor current
Accessories
Standard
Optional
Note: 1) The above MCBOA channels are part of basic model and can be customized as per specific requirements. 2) Size and weight of the instrument will vary depending on
channel requirement.
Protection Testing - MCBO-A 76
Features
100 A DC current injection through battery with inbuilt
charger
Recording of DCRM signature of contact by four-wire
the method which ensures high accuracy & repeatability
Quick performance check of the circuit breaker by taking
a C-O operation on the breaker with time resolution in
micro-seconds and selectable delay between multiple
operations
Supplied with test lead set suitable for EHV circuit
breakers having quick-fit connectors
Housed in a robust carrying case that can be connected
to an existing MCBOA series of circuit breaker test
systems.
MDCRM
Portable Dynamic Contact Resistance Meter Measurements
Quick performance check of the circuit breaker by
MDCRM is used to measure the dynamic contact resistance and plot a measuring the dynamic behavior of contacts.
dynamic contact resistance curve (DCRM signature) against time, Correlation of DCRM with travel characteristic using
which helps to monitor the condition of the contacts without opening customized travel transducers and fixtures
the interrupter. A test current of 100A DC is injected into the contact Recording of DCRM signature of a single interrupter at a
and the dynamic value of the circuit breaker contact resistance is
time
measured when the Breaker is performing a C-O operation. MDCRM is
Independent, isolated, inbuilt 100 A DC source for single
used essentially to test the MV and EHV Circuit Breakers with
interrupter.
insertion type of contacts.
When DCRM signature is correlated with travel curve, the
health of main and arcing contacts can be ascertained,
and wear and tear of arcing contacts can be estimated
Health of the damping mechanism is also monitored
Protection Testing - MCBO-A 77
Software Features
Easy-to-use, high-level graphical user interface and programmable test plans help to create a test setup library
Upgrade for existing Windows-based MCBOA test software of earlier versions, to allow an analysis of DCRM signatures
Specifications
Resistance range 8000μ , 4000μ , 2000μ full-scale
Output 0 to 5 V DC
Weight 10 Kg Approx.
HS Code 90318000
Accessories
Standard
Optional
Features
Locates & pinpoints DC Ground fault in
Online/Offline condition.
Incorporates Automatic Capacitive Balancing & is
fully automatic.
Highly immune to noise in the system.
Extremely high sensitive to Fault Signal.
Light weight and user friendly.
Bluetooth Enabled
Lightest Weight in Industry
Rechargeable Battery operated.
L, M & H mode for Different types of fault location.
Connected to Cloud
MGFL
DC Ground Fault Locator
Applications
Battery systems used in protection devices are designed
Floating DC systems are the back bone of any substation. and operated as a floating from ground system which
Malfunctioning of DC system / non-availability of sound DC system means that there is no intentional connection to ground
can lead to very big catastrophe in the substation and hence it is a from either the positive polarity or negative polarity of the
necessity that the floating DC systems in the substation should be free DC system. Sometimes, a very low resistance or solid path is
from any faults. established from one of the polarity of DC system to ground
which can lead to significant voltage drop, & continuously
The DC Ground Locator MGFL helps substation engineers in locating, draining of battery bank. The usual suspects for DC ground
tracing, pinpointing DC ground faults in any floating DC system up to faults include worn insulation, conductive dust, water, or
300V DC in Online and Offline condition. The MGFL is a portable light other "soft grounds." Ground faults account for more than
weight instrument used to locate ground fault in DC systems. It 85% of equipment short circuits and in 95% of those cases it
consists of a Transmitter Unit and Receiver Unit. The transmitter is is caused by insulation deterioration on wires and cables.
connected to live / non-live floating system up to 300V DC preferably These DC earth faults need to be rectified in time to avoid
on the DC bus. It then transmits low frequency and low voltage signal unscheduled breakdown.
in the DC system without affecting the sensitive operation of relays.
Major Application
The transmitted signal is then tracked by receiver to locate the fault
feeder and to track it further up to the point of fault. The instrument Utility - DC system with faulty grounding
balance the capacitance of DC system automatically and is fully Railway - Signal, communication and locomotive electric
automatic to detect any faults. The instrument incorporates advanced equipment.
signal processing to eliminate noise in the DC system and is very
Industrial Facilities - Electric safety equipment for general
sensitive to any ground faults. The instrument is fully automatic and
power distribution applications.
detect earth faults / mixing of source at ease.
Telecommunication etc.
Protection Testing - MGFL 79
Accessories
Technical Details MGFL
Standard
Receiver unit
Transmitter unit
Test lead Set with crocodile clips Clamp 25 mm
Power
Clamp 20 mm
Transmitter Spare battery - 9V
Rechargeable Li-ion Batteries Charged By 5v Charger Charger 9V - Receiver unit
Charger 5V - Transmitter unit
Receiver
Instruction Manual
Rechargeable Site Replaceable Li-ion Batteries Charged By 9V Charger
Signal Voltage
Frequency
Fault Resistance
Sensor Probe
Temperature
Storage 00C to 550C
Dimensions in MM
Weight
Transmitter 0.5 kg
Receiver 0.2 kg
Motwane has designed and developed MOT-WARE – a cloud based test data platform to aid in accurate Asset Health Assessment. Through
MOT-WARE, the test and measurement industry has taken a huge leap forward. MOT-WARE captures data from full range of BLE enabled
Motwane testing equipment. It is a user-friendly platform as it is also accessible from a web-based, desktop as well as a mobile application. In
addition, it offers an open architecture that can seamlessly integrate with any non Motwane test and measurement equipment for quick and
authentic digital test data, captured periodically as well as streamed with real-time data via sensors from IoXn series of IOT devices.
MOT-WARE has a preloaded repository of test templates for various electrical assets as well as customizable test templates. A customized
report builder in MOT-WARE allows the user to generate report in their own format. It also has a facility to upload historical test data and
breakdown history of assets. Test results can also be viewed by various metrics, such as pass or fail.
Data Analysis is also done through MOT-WARE which includes Trend Analysis, MIS Reports and Pivot Tables. As an add-on, MOT-WARE also
offers “Motwane AI Analytics” which uses a proprietary AI algorithm and Machine Learning to make accurate predictions about assets life,
based on its behavioural patterns and operating conditions.
Being centralized test data, it helps in improving life of assets, its productivity and efficiency, cost reduction, etc. It can be used for various
applications across customers' segments like Utilities, OEMs, Industry, Electrical contractors (Testing, O&M) or Field repairs & Service
Provider, EPCs, commercial premise and many more.
Important Benefits
Features
Simultaneous display of fundamental & 3 Harmonic
Leakage Current and Resistive 3 Harmonic Leakage Current.
Highly immune to noise in the system
Data Transfer to your smart phone
Android Application to trend monitor your LA
Export report to excel/graphical pdf format directly from
the App.
User-friendly, rugged and very light weight.
MLCM
Leakage Current Monitoring Applications
Lightning arrester is connected between high voltage
CAT III IP terminals and ground terminals for the protection of the
equipment at the substations against travelling waves i.e., in
600V 54
parallel with the equipment to be protected at the
substation. In other words, when a lightning surge (or
The MLCM is a light weight, cost effective, portable and comes handy
switching surge) travels along the power line to the arrester,
to monitor the healthiness of lightning arrester. MLCM measures the
the current from the surge is diverted through the arrester,
fundamental and third harmonic leakage current down to micro
in most cases to earth without affecting the continuity of
ampere. This makes it easy for maintenance engineer to check and
supply.
monitor in-service lightning arresters periodically and determine their
healthiness. As and when the LA deteriorate, the third harmonic Lightning arresters at substations are exposed to a variety
leakage current also increases which provides a clear indication for of stress factors originating both from the network and from
maintenance engineer to take immediate action. their service environment. These stressors can then cause
premature ageing or even damage to their varistor blocks.
The main types of such degradation can be classified as
either:
Main Application
Accessories
Technical Details MLCM
Standard
Continuous update of display and app every second without delay in processing.
Accuracy
Variant's
IEC 60099-5 B1, B1& B2.
Software
Android app to download test data and to monitor the trend of LA's.
Correction Factor
Temperature and voltage correction for B1 and B2 variant. System 3rd harmonic
Temperature
Weight
Features
Simultaneous display of fundamental & 3 Harmonic
Leakage Current and Resistive 3 Harmonic Leakage Current.
Highly immune to noise in the system
Data Transfer to your smart phone
Android Application to trend monitor your LA
MLCM
Export report to excel/graphical pdf format directly from
the App.
User-friendly, rugged and very light weight.
MLCM-B2
Leakage Current Monitor
Accessories
Technical Details MLCM-B2
Standard
B1 Method MLCM - B2
Total 50 Hz + Total 3rd harmonic current, + B1 w/o system harmonic compensation
B2 Method
All results of B1 + 3rd harmonic resistive current with system third harmonic
compensation
Both B1 & B2 are provided with rated voltage and temperature compensation
Resolution 1 UA
Software
The instrument is provided with smart android device with inbuilt printer and
Android app to download test data and to monitor the trend of LA's. The user
can view results graphically, generate pdf reports, share results with colleagues
Weight ~1 kg approx.
Features
Variable Output Voltage AC/DC/AC+DC
Selectable Trip Current
Zero Start Interlock
Timer to set duration of test
Audio/Visual Indications
Overload Protection
High Leakage Current Range
Supply Fault / Earth Open Interlocking Door / Cabin
Door Interlock
Wheel mounted for easy transportation
Applications
Dielectrics (insulation) for electrical equipment and
apparatus is used for many different applications. It is
expressed for a wide range of environmental conditions
HVT Series such as temperature, moisture, chemicals, other
AC-DC Hi Pot Test Set contaminants, and exposure to weather. One major factor
affecting insulation life is thermal degradation, although
moisture, contamination, voltage stress, and other factors
The Motwane's Hi-Pot Tester, HVT series offers a wide range of test
may also contribute to its degradation. In addition, the life of
voltages to determine the withstand strength of electrical insulation
an insulating material depends on the degree of loading, the
for the normally occurring over voltage transients. HVT series sets
type of service to which the equipment is subjected, the
are available in a wide range of voltage and power ratings with
care it receives during installation and operation, and
exceptional reliability, durability and functionality which can
mechanical vibration and forces to which it is subjected.
generate AC, DC or AC+DC voltages (eliminates the need of two
separate kits). Available with manual / motorized controlled A dielectric withstand test is an electrical test performed on
operation provides variable output voltage. Test sets had selectable a component or product to determine the strength of
tripping current to identify breakdown voltage of different test insulation. Voltage applied between equally insulated
objects and also have timer, useful to set duration of test period. HVT sections of a part or energized parts and electrical ground
series is provided with HV indication, supply fault / earth open under test and determining the leakage current that may
interlocking & door / cabin interlocking & overload protection flow under test conditions. Excessive leakage current flows
provided for safety of operator & test set. may indicate a deteriorated condition or impending failure
of the insulation. Insulation testing can be performed by
applying either direct current (DC) voltage or alternating
current (AC) voltage The test to qualify a device's ability to
operate safely during rated electrical conditions. If the
current through a device under test is less than the specified
limit at the required test potential and time duration, the
device meets the dielectric withstand requirement. A
dielectric withstand test may be done as a factory test on
new equipment, or may be done on apparatus already in
service as a routine maintenance test.
Technical Specification
Output Voltage 5KV 10KV 15KV 20KV 30KV 40KV 50KV 70KV
Burden at 50mA 0.25KVA 0.5KVA 0.75KVA 1KVA 1.5KVA 2KVA 2.5KVA 3.5KVA
Burden at 100mA 0.5KVA 1KVA 1.5KVA 2KVA 3KVA 4KVA 5KVA 7KVA
Voltage Meter 0.-5KV 0.-10KV 0-15KV 0-20KV 0-30KV 0-40KV 0-50KV 0-70KV
Protected by MCB,
Protection and
Fuse Zero Start Interlock
Safety
Earth Open/ Supply Fault Interlock, Door/ Cabin Interlock
Operating
0-55°C, 5-90% RH Non Condensing
Temperature
*We also provide customized High voltage test set as per requirement
Ordering Information
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes continuous improvement of its product. We, therefore,
reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - MOT-RTS 87
Features
Compact unit with rugged case
Variable model and selectable Output Current
up to 200A/600VA
Output Voltage 0-250V AC/DC
Auto Cut-Off upon Tripping Relay
Timer Range 0.0001-9999 Seconds Auto Ranging ,
Digital Timer with Accuracy +0.05% + 2 Counts
Wheel mounted for easy transportation
MOT - RTS
Relay Test Set
The Motwane's RTS Series also known as kit is a portable, cost Applications
effective is portable cost effective solution to test voltage & current
The secondary current injection test of solid-state units
based relays. It is designed with highly accurate digital meters for
can be performed by a specially designed power supply
testing of protective devices. The MOT-RTS set provides high burden
unit. Secondary injection tests are always done prior to
to test electromechanical relays. RTS Series can provide up to 200A
primary injection tests. The purpose of secondary injection
for CT, MCB Testing. The compact & rugged design makes it easy to
testing is to prove the correct operation of the protection
move in relay room.
scheme that is downstream from the inputs to the
protection relay(s). This is because the risks during initial
testing to the LV side of the equipment under test are
minimized. It should be noted that the secondary current
injection method only tests the solid-state trip unit logic
and components like relay, miniature breaker etc.
Technical Specification
Selectable Current
0-1-5-10-25-
Ranges (O/P current 0-1-5-10A 0-1-5-10-20A 0-1-5-10-25-50A 0-1-5-10-25-50-100A
display on % Ammeter)
50-100-200A
Voltage resolution 1V
Protection and Safety Fast blow glass fuse Over current tripping
PVC insulated 2.5 sq. PVC insulated 10 sq. mm PVC insulated 16 sq. PVC insulated 25 sq. PVC insulated 50 sq.
Output Current leads mm cu cables 2X1.5mtr cu cable 2X1.5mtr lug mm cu cable 2X1.5mtr mm cu cable 2X1.5mtr mm cu cable 2X1.5mtr
lug at both ends at both ends lug at both ends lug at both ends lug at both ends
Ordering Information
MOT-RTS10/200 10A Relay Test Set
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Protection Testing - MOT-RTS 89
Accessories
Standard
Lead sets
Instruction Manual
Short Link
Spare Fuse
Calibration Report
Warranty Certificate
Protection Testing - PIK Series 90
Features
Variable Output Current
High VA burden to test high impedance objects
Digital timer for measuring tripping time
Zero Start Interlock for safety
Auto Cut-Off upon Tripping Relay
Current range ( Low - 50% & High - 100% of full range )
CT sec current measurement (Optional)
CT Polarity Detection (Optional)
Wheel mounted for easy transportation
Optional Features
Technical Specification
Output Current 0-200A 0-500A 0-800A 0-1000A 0-1500A 0-2000A 0-2500A 0-3000A
O/P Resolution 1A
Unit Combined control & loading unit Separate control & loading units
Standard 50 mm2 120 mm2 180 mm2 240 mm2 400 mm2 480 mm2 600 mm2 720 mm2
Output Cables (2X5) meters (2X5 ) meters (2X5 ) meters (2X5) meters (2X7) meters (2X10) meters (2X10) meters (2X10) meters
Ordering Information
MOT-PIK200/1 Primary Current Injection Kit : 200A with 1kVA Burden
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Protection Testing - PIK Series 92
Accessories
Standard
Spare Fuse
Short Link
Instruction Manual
Calibration Certificate
Warranty Certificate
Optional
C - clamp
Interconnecting cables
High Voltage Detectors 93
Features
Colour Code models for different voltage levels.
Non-contact / Contact type Detectors.
Indicates presence of High Voltage by Audio
Annunciations as well as Visual Indications.
Bright high intensity red LED's provide clear visual
Bullet even in unfavourable daylight conditions.
A Buzzer produces a loud beep which is audible even in
noisy backgrounds.
Supplied as a complete kit with HV Detector, Telescopic
Fibre Glass Insulation stick and ergonomically designed
sturdy carry bag.
Self test button to test battery and proper functioning
of HV detector.
Powered by a single 9V battery type (6F22), easily
replaceable on field.
Type tested at CPRI/ERDA
Available in FRP Telescopic Rod / FRP Sectional Hot Stick
Rod in 1.2 / 3 / 5 mtr.
Universal Link
High Voltage Detectors 94
Technical Specification
Voltage Range 230V - 33kV 3.3kV - 33kV 11kV - 132kV 33kV - 220kV 66kV - 440kV
Type Non Contact Non Contact Contact/Non Contact Contact/Non Contact Contact/Non Contact
Sensing Distance - - 1mtr - 3mtr - 5mtr 1mtr - 3mtr - 5mtr 1mtr - 3mtr - 5mtr
General Specifications
High Voltage Indication
RED LEDs start flashing with an audible buzzer if taken into High Voltage induction area.
Electrical Specifications
Visual Indication High Bright LEDs flashing Material Fibre Glass (Sturdy & Rugged)
Audible Indication Buzzer beeps Loudly Length Telescopic Extendable length 3 mtrs.
Environmental Specifications
Recommended Operating Physical Specifications
Temperature Range 5°C to 50°C Length 245mm Approx.
Accessories
Standard
Carrying Bag
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Earth/Ground Tester - DET20 95
Features
3 ½ digit LCD Display with max reading 1999.
3 terminal and 4 terminal Measurement Method
Earth Resistance Range 0.01Ω to 1999Ω
4 Soil Resistivity Measurement
Rechargeable Internal Ni-MH Battery
Earth Measurement Voltage up to 200V
Ratio Metric Synchronous Rectification
Applications
The integrity of the grounding system is very important in
an electrical power system for the following reasons:
Accessories
Technical Details DET 20
Standard
operation on mid-range.
Interference
Interference voltage of 20V +5% peak to peak, 50Hz in the potential circuit will
have a maximum effect +1% on the reading obtained form 20 Ω to 2KΩ ranges.
Influence of Temperature
<+0.2% per0 C over the temperature range 0-200C and 28-550C.
Temperature Range
Operating : 00C to +550C <90% RH
Humidity
Voltage withstand
In the event of as system fault, the instrument will withstand 240V AC, applied
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Earth/Ground Tester - DECT 3 97
Features
Resistance range up to 1200 Ohms.
AC Leakage Current Measurement up to 20A.
RS 232 Interface for monitoring, uploading analysing &
printing of data.
Memory Storage capability of 99 records.
Alarm setting feature with selection range available for
resistance and current.
Improved Jaw Opening & Closing
Fast self-test & Calibration.
Soft touch keys.
Rugged Casting and easy to use.
DECT 3
Digital Clamp on Earth Resistance Tester
Applications
Motwane's new Digital Clamp on Earth resistance Tester, DECT-3
Clamp on measurement method is new and quite unique. It
measures earth resistance using clamp on technology. Clamp on is a
offers the ability to measure the Earth Resistance without
relatively new method of determining the quality of a ground system.
disconnecting the ground. This type of measurement also
DECT-3 can measure Earth Resistance, earth bonds measurement &
offers the advantage of including the bonding to ground
also measures AC leakage current. It's actually recommended to use it
and the overall grounding connection resistances and also
on sites where there are multiple grounds placed in parallel and not
indispensable troubleshooting tools to help you maintain
required to isolate the ground rod. Simply clamp around the
uptime. It is recommended that all grounds and ground
conductor or earthing strip and measure the Earth Resistance fast and
connections be checked at periodically as a part of normal
accurately. The unique big jaw is particularly suitable where
predictive maintenance plan. If there is an increase more
grounding is done by flat steels or copper strips. It has low battery
than the acceptable limit during these periodic checks, the
indication & data hold facility within built memory storage of up to 99
engineer should investigate the source of the problem and
test results. DECT-3 has got the double insulation level and is
make the correction to lower the resistance by replacing or
protected from external magnetic & electric fields.
adding ground rods to the ground system.
Technical Detail
General
Display 4 digit LCD , 47 mm X 28.5 mm
Computer Interfacing RS 232 for uploading the stored data and analysing at later time
Sound & Light annunciator Beep sound, Flashing Symbol, 'AL' key to turn on-off & setting the sound & Light alarm
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes continuous improvement of its product. We, therefore,
0 0
reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Earth/Ground Tester - DECT 2 99
Accessories
Standard
Instruction Manual
Carrying Case
Calibration Certificate
Earth/Ground Tester - DECT 2 100
Features
Display 4 digits LCD
Range : 0.01Ω to 1200Ω
Resistance Measurement Resolution 0.001
Memory storage capability of 99 records
Long jaw size: 65mm — 32mm
The unique Long Jaw is particularly suitable where
grounding is done by flat steel or copper strips
Alarm setting feature with selection range available
from 1 Ω to 199 Ω
Double insulation level and also protected from external
magnetic field as well as electric field
Automatic Range Selection, Automatic Self-Calibration
Single Measuring Time: 0.5 seconds
DECT 2
Digital Clamp on Earth resistance Tester
Applications
Clamp on measurement method is new and quite unique. It offers the
Clamp on measurement method is new and quite unique. It
ability to measure the earth resistance without disconnecting the
offers the ability to measure the earth resistance without
ground. This type of measurement also offers the advantage of
disconnecting the ground. This type of measurement also
including the bonding to ground and the overall grounding
offers the advantage of including the bonding to ground
connection resistances and also indispensable troubleshooting tools
and the overall grounding connection resistances and also
to help you maintain uptime. It is recommended that all grounds and
indispensable troubleshooting tools to help you maintain
ground connections are checked periodically as a part of a normal
uptime. It is recommended that all grounds and ground
predictive is seen maintenance plan. If an increase in resistance of
connections be checked periodically as a part of normal
more than acceptable limit during these periodic checks, the engineer
predictive maintenance plan. If an increase in resistance of
should investigate the source of the problem and make the correction
more than acceptable limit during these periodic checks,
to lower the resistance by replacing or adding ground rods to the
then the engineer should investigate the source of the
ground system.
problem and make the correction to lower the resistance by
replacing or adding ground rods to the ground system.
Technical Detail
General
Display 4 digit LCD , 47 mm X 28.5 mm
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
range to 95% of the range. 5. Accuracy specified for temperature range of 250C + 50C & 55% RH + 10%.
Digital Multimeter - M63 102
Features
6000 Count LCD display with pleasant white backlit.
AC/ DC Current range upto 20A.
Resistance, Capacitance, Diode & Continuity
Measurement Facility.
Selectable Frequency & Duty Cycle Measurement.
60 position analog bar graph for trend indication.
Highly Linear Readings.
Select, Range, Hold/Light, Rel, Hz/duty.
Max/Min functions incorporated
Safety - CE, CAT IV(600V), IP 54, EN61326-1 & IEC 61010-1
Robust, Rugged & Double Mould Casing.
M63
Digital Multimeter Industrial Graded
CAT iV IP Applications
600V 54 Power Utility
Industries
The Motwane’s Terms Industrial Graded Digital Multimeter M63 is Electrical Contractor
specially designed in our research laboratory & went under stringent
Telecommunication
manufacturing process for a wide range of applications like Power
Railway
Generation, Power Distribution, Power Transmission, Steel Industries,
Defence
Cement Industries, Mining Industries, Power Electronics Industries,
Heavy Engineering Industries and Defence Sector & Aviation Sector.
M63 is a versatile and high-performance industrial grade multimeter
that complies with IEC 61010-1-2010 safety standards and excellent
noise immunity to disturbances from energized power lines, with CE,
CAT IV 600 V safety rating IP-54 protection.
Digital Multimeter - M63 103
General
Display 6,000 Count LCD display with white backlit.
Environmental
Power
Power Supply 9V Battery Type 6F22 or equivalent
consumption is 300uA approx. (Can be cancelled by pushing SELECT key before power on the meter).
Overload Protection:
Fuse Protection for ‘mA’ input terminal 0.75 A/ 0.8 A/ 500V fast blow type ceramic fuse.
Fuse Protection for 20A input terminal 20A/ 500V fast blow type ceramic fuse
Safety
Accessories
Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.
DC Voltage
Range Resolution Max. Reading Accuracy Overload Protection
AC Voltage (50-500Hz)Trms
Range Resolution Max. Reading Accuracy Overload Protection
6V 1 mV 6.000 V +(1% + 5)
DC ‘mV’ Range
Range Resolution Max. Reading Accuracy Overload Protection
60 mV 0.01 mV 60.00 mV +(0.5% + 3)
1000V DC/AC rms
600 mV 0.1 mV 600.0 mV +(0.5% + 3)
DC Current Range
6A 1 mA 6.000 A +(1% + 5)
20A/500V DC/AC
Note : 1. 10A for continuous 2. >10A for 20sec. after 15min. cool down interval
6A 1 mA 6.000 A +(1.2% + 5)
20A/500V DC/AC
Note : 1. 10A for continuous 2. .>10A for 20sec. after 15min. cool down interval
Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection
600 Ω 0.1 Ω 600.0 Ω +(0.5% + 3)
6 KΩ 1Ω 6.000 Ω +(0.5% + 3)
60 KΩ 10 Ω 60.00 K Ω +(0.5% + 3)
1000V DC/AC rms
600 KΩ 100 Ω 600.0 K Ω +(0.5% + 3)
6 MΩ 1KΩ 6.000 M Ω +(1% + 5)
60 MΩ 10 K Ω 60.00 M Ω +(3% + 5)
Note : 1. Open Circuit Voltage on 600 -6M ranges is 0.62V DC approx. 2. Open Circuit Voltage on 60M range is 0.31V DC approx
Digital Multimeter - M63 105
Continuity Test
Range Resolution
Accessories
Standard
Standard Accessories
Optional
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Digital Multimeter - M65 106
Features
6,000 Count LCD Dual display with white backlit.
Auto ranging, terms AC Voltage & Current measurement.
Basic DCV Accuracy of 0.25%.
Highly Linear Readings.
Capacitance Range upto 60mF.
Resistance, Diode and Continuity Measurement Facility
Selectable Frequency & Duty Cycle Measurement.
60 position analogy bar graph for trend indication.
Select, Range, Hold, Rel, Lights, Max/Min
Functions Incorporated.
CE and IEC 61010-1 CAT III (1000V), IP 54 protection.
Robust, Rugged and Double Mould Casing.
M65
Digital Multimeter
Accuracy
Accuracy is valid from 10% of range to 95% of the range.
Accuracy is specified as + % of reading + digits and is valid at 25 + 30C, < 55% RH Humidity.
It is recommended that calibration equipment used to verify the accuracy of the instrument should be 10 times more accurate.
Temp. Coefficient = (0.1% x Specified accuracy) per degree centigrade referred to 25°C. Accuracy is not valid if display shows ' LO BAT'.
General
Dual Display For AC Voltage with Frequency & Frequency with Duty Cycle simultaneously
Environmental
Operating Temperature 0°C to 50°C
Power
Power Supply 9V Battery Type 6F22 or equivalent
Overload Protection
Fuse Protection for ‘µA’ & ‘mA’ input terminal 0.8 A/ 250V fast blow type ceramic fuse.
Fuse Protection for 10A input terminal 20A/ 500V fast blow type ceramic fuse
Safety
Accessories
Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.
Digital Multimeter - M65 107
Optional Accessories
Pair of test leads, Pair of small test leads
6V 1 mV 6.000 V +(0.25% + 3)
Note: 1. Input Impedance 10M approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).
6V 1 mV 6.000 V +(1% + 5)
Note : 1. Input impedance : 10 MΩ approx. shunted by 60pF approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).
3. Main display shows AC Voltage & sub display shows frequency applied.
DC Current Range
Range Resolution Max. Reading Accuracy Overload Protection
Note: Main display shows AC Current and sub display shows frequency applied.
Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection
6 KΩ 1Ω 6.000 Ω +(0.5% + 3)
60 KΩ 10 Ω 60.00 KΩ +(0.5% + 3)
440V DC/AC rms
600 KΩ 100 Ω 600.0 KΩ +(0.5% + 3)
6 MΩ 1 KΩ 6.000 MΩ +(1% + 5)
Note : 1. Open Circuit voltage on 600Ω range is -3.3V DC approx. 2. Open Circuit voltage on 6kΩ-6MΩ ranges is -1.10V DC approx.
Note : 1. Settling time on 6mF and 60mF range is 40 sec. approx. 2. Press REL button at 6nF & 60nF ranges so that the offset count can be subtracted
Diode Test
Range Resolution Open Circuit Voltage Test Current
6V 1mV <3.0 V DC approx. <2.0mA approx.
Continuity Test
Range Resolution
600.0Ω 0.1Ω Meter Beeps < 60Ω
Note: 1. Main display shows frequency & sub display shows Duty Cycle. 2. If input frequency is less than 6.0Hz, display will show 0.00Hz.
Accuracy is specified at <20 VAC rms Sensitivity : 10Hz to 100 KHz > 200mVrms, 1000 KHz to 10MHz > 2Vrms
Electromagnetic compatibility: In RF Field, overall accuracy is equal to 10% of reading +30 digits
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Digital Clamp Meter - DCM49A 110
Features
3 ¾ digit LCD, 4000 counts, multi-function 1000A AC/DC.
Large Jaw Size : 60mm.
Function Rich, AC/DC Current, AC/DC Voltage, Resistance,
Diode, Continuity, Capacitance, Frequency and Duty Cycle.
Large Backlit display with rich annunciations.
Auto Power Off for battery life saving.
Relative Reading and Data Hold Functions.
Ergonomic Design for holding.
Suitable for use in Appliance Testing, Portable Tools,
Building Wiring
Testing of Electronic / Electrical Products.
DCM49A
Digital Clamp Meter
CAT II Applications
600V Power Utility
Industries
DCM49A is a general-purpose 3 ¾ digit AC / DC Clamp Meter with a Electrical Contractor
backlit LCD display. The jaw opening is 60mm approx. & can measure Telecommunication
AC / DC current through the clamp up to 1000A. It also measures DC Railway
Voltage-1000V, AC voltage-700V, and resistance up to 40M ,
frequency 10 MHz with duty cycle, continuity & diode measurements.
This meter also has a capacitance range of up to 100µF & is powered
by one 9V battery.
Digital Clamp Meter - DCM49A 111
Accuracy
Accuracy are claimed from 10% of range to 95% of the range.
All claim of Accuracy are at decade value i.e 10, 100 tec.
General
Environmental
Operating Temperature 0°C to 40°C <80% RH (Non condensing)
Battery Removed
Power
Power Supply 9V Battery NEDA 1604 / Type 6F22/006P
Standard Accessories
Pair of Test leads, User Manual, Battery installed
4V
40V
+(1.5% + 10d) 1000V DC OR 750 V AC rms 100M
400V
1000V
4V
40V
+(1.5% + 10d) 1000V DC OR 750 V AC rms 100M
400V
700V
Digital Clamp Meter - DCM49A 112
400A 0.1A
+(2.5% + 10d) 102% of Full scale for <60 Sec.
1000A 1A
4 KΩ
40 KΩ
+(1% + 5d) 250V DC/AC rms
400 KΩ
4 MΩ
40 MΩ
Diode Test : Measure forward voltage drop. Evers circuit. Voltage approx. 1.5V Input protected upto 250V DC or AC rms.
Continuity : Buzzer sound if resistance <50 Ω, Input protected upto 250V DC or AC rms.
Duty Cycle
Range Accuracy Sensitivity Overload Protection
Note : Its use is not advised on multi phase high energy circuits where heavy transient are likely to occur.
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Digital Clamp Meter - DCM 39A/9930A 113
Features
Auto Ranging 3 ¾ digits (3999) LCD-Display.
True RMS reading for ACV & ACA
2 in 1 Clamp Meter + Digital Multimeter.
Overload protection for all ranges.
Data Hold, Relative Key Facility
Water Resistant front panel, Fireproof heavy-duty
ABS Casing.
Current Sensor-Hall Effect Sensor
Over Range Indication: 'OL' is displayed.
Max Conductor size 60mm approx.
Power – one 9V battery type (6F22)
DCM 39A/9930A
Digital Clamp Meter
Motwane's Digital Clamp Meter DCM 39A & DCM 9930A are highly Applications
precise, industrial grade, Trms, auto ranging clamp meters with 3 ¾
digit display. Both these clamp meters can be used as multimeter Generation, Transmission & Distribution
with test leads for AC/DC Current measurements up to 400 mA, Substation Process Industries.
AC/DC Voltage, Resistance, Frequency, Capacitance, Duty Cycle and OEM's
Diode, Continuity etc. These clamp meters are provided with safety Railway's
features like water resistant front panel, fireproof heavy-duty ABS Telecom Industries
casing. It uses a Hall Effect Sensor for measuring the current. The
Service Industries
model DCM 39A measures AC/DC currents up to 1000A. The model
DCM 9930A measures AC/DC currents up to 2000A.
Digital Clamp Meter - DCM 39A/9930A 114
General
Display 3 ¾ Digits LCD display.
Power
Standard Accessories
Pair of Test leads, User Manual, One 9V Battery installed
Overload Protection : AC/DC 500mA(Fuse) | AC/DC 1000A/1000V | Frequency Response : 45Hz - 1KHz
4V 0.001 V + 1% + 2dgt
1000V DC OR 1000V
40V 0.01 V + 1% + 2dgt
AC rms (Sine wave)
400V 0.1 V + 1% + 2dgt
1000V 1V + 1% + 2dgt
AC Voltage
Range Resolution Accuracy Overload protection
Resistance Range
Range Resolution Input Accuracy
4 KΩ 1Ω + 1% + 5dgt
40 KΩ 10 Ω + 1% + 5dgt
400V DC/AC RMS (Sine wave)
400 KΩ 100 Ω + 1% + 5dgt
4MΩ 1 KΩ + 2% + 2dgt
40 M 10 K + 3.5% + 5dgt
Capacitance Range
Range Resolution Input Accuracy
Amplitude : < 5V
Duty Cycle
Range Resolution Accuracy Overload protection
0.1%-99% 0.1% + 1% + 5dgt 1000 V AC/DC
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Notes :
Notes :
Contact Details Scan the QR code to visit
Motwane’s new website
www.motwane.com
Toll-free number:
National : 17/08/2021
https://www.linkedin.com/company/motwanemanufacturing