You are on page 1of 5

ComFlor 46/0.

9/S280 BS 5950 Parts 4, 6 and 8 Page 1 of 5

SCI Tata Steel - Middle East v9.0.34.24751


JOB REFERENCE: Date: 26/5/2023
DECK REFERENCE: CF46/0.9_280 Time: 12:26:42
COMPANY NAME: Job No.:
CLIENT NAME:
FILENAME: Calcs by: Checked by:

FULL OUTPUT

NOTE: SECTION DESIGNED TO BRITISH STANDARDS


Construction Stage: PASS Max Unity Factor = 0.35
Normal Stage: PASS Max Unity Factor = 0.35
Fire Condition: PASS Max Unity Factor = 0.00
Serviceability: SATISFACTORY Max Unity Factor = 0.16

*** SECTION ADEQUATE ***


FLOOR PLAN DATA : (unpropped composite construction with ComFlor 46/0.9/S280 decking)
Beam centres 1.45 m Span type SINGLE
Beam or wall width 150 mm Propping NONE
PROFILE DATA : (ComFlor 46/0.9/S280 decking)
Depth 46 mm Pitch of deck ribs 225 mm
Trough width 105 mm Crest width 67.0 mm
Nominal sheet thickness 0.90 mm Design sheet thickness 0.86 mm
Deck weight 0.09 kN/m² Yield strength 280 N/mm²
CONCRETE SLAB : [Normal Weight Concrete ; Grade C25; Mesh : A142]
Overall slab depth 110 mm
Concrete characteristic strength 25 N/mm² Concrete wet density 2400 kg/m³
Modular ratio 10 Concrete dry density 2350 kg/m³
Bar reinforcement NONE
Mesh reinforcement :
Mesh A142 Yield strength 230 N/mm²
Cover to Mesh 30 mm Mesh Layers Single
Account for End Anchorage NO Shear connectors per rib N/A
Diameter of Shear Connectors N/A
Screed depth 10 mm Screed density 2000 kg/m³
SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations
DECK PROFILE:
Sagging Inertia, Ixx 39.025 cm4/m Area of profile (Net), Ap 1137 mm²/m
Hogging Inertia, Iyy 40.818 cm4/m
COMPOSITE:
Inertia, Ixx - Uncracked 1022 cm4/m Cracked 521 cm4/m
Average inertia 771 cm4/m Cracked inertia (dynamic) 592 cm4/m
Shear bond coefficients - Mr 80.36 Kr 0.008600
Concrete volume 0.091 m³/m/m
LOADS ACTING ON SLAB :
*** NOTE: Slab subjected to uniformly distributed loads (UDL) ONLY
Imposed (occupancy) 5.00 kN/m² Partitions 1.00 kN/m²
Ceilings and services 0.50 kN/m² Finishes 0.50 kN/m²
Self weight of concrete slab (wet) 2.13 kN/m² Self weight of decking 0.09 kN/m²
Self weight of concrete slab (dry) 2.09 kN/m² Self weight of screeds 0.20 kN/m²
Construction load 3.1 kN/m²
LINE LOADS PERPENDICULAR TO DECK SPAN :
None
LINE LOADS PARALLEL TO DECK SPAN :
None

File Name: v9.0.34.24751


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 2 of 5

FIRE DATA :
Design method SIMPLE Fire resistance period 30 mins
Non-permanent imposed loads 0.0 kN/m²
PARTIAL SAFETY FACTORS :
Dead (self weight) 1.50 Imposed 1.50
Super imposed dead 1.50 Fire (occupancy loads) 0.80

File Name: v9.0.34.24751


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 3 of 5

CONSTRUCTION STAGE

LOADINGS Unfactored(kN/m²) Factored(kN/m²)


Self weight of decking 0.09 0.14
Self weight of concrete slab (wet) 2.13 3.20
Construction load 3.10 4.66
Total factored load (maximum) = 0.14 + 3.20 + 0.00 + 4.66
= 8.00 kN/m²
NOTE: Critical span is longer span
EFFECTIVE SPAN OF DECK :
Effective span Le, is the smaller of
1) c/c of supports = 1.45 m
2) clear span + deck depth = 1.30 + 46.0 / 1000
= 1.35 m
Therefore Le = 1.35 m
SHEAR RESISTANCE CHECK :
*** Check at exterior support
Applied shear = [0.500 * 0.14 + 0.500 * 3.20 + 0.500 * 0.04 + 1.500 * 4.66/3] * 1.35
= 5.41 kN/m
Shear strength of decking, pv = 168.0 N/mm²
Shear resistance, Pv = 59.1 kN/m
UNITY FACTOR = 0.09 PASS
WEB CRUSHING RESISTANCE CHECK :
*** Check at exterior support
Applied reaction 5.41 kN/m
Web crushing resistance, Pw 38.03 kN/m
UNITY FACTOR = 0.14 PASS
BENDING RESISTANCE CHECK :
SAGGING:
Max applied moment = [0.125 * 0.14 + 0.125 * 3.20 + 0.125 * 0.04 + 0.125 * 4.66] * 1.35^2
= 1.82 kNm/m
Moment resistance, Mc = 5.17 kNm/m
UNITY FACTOR = 0.35 PASS
DEFLECTION CHECK :
Allowable deflection ðmax, is the lesser of
1) Effective span/180 (= 7.5 mm ), and
2) 20 mm ( absolute maximum value ), and
3) Slab depth/10 = ( 11.0 mm )
Max. self weight deflection = 5 / 384 * 2.23 * (1.35* 1000 )^4 / (*390249 )/1000
= 1.20 mm
( < 7.48 mm ) SATISFACTORY
***NOTE: Deflection within code limits; ponding is not considered

File Name: v9.0.34.24751


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 4 of 5

NORMAL STAGE

LOADINGS : (see construction load calculations for details):


Unfactored (kN/m²) Factored (kN/m²)
Dead 0.09 + 2.09
= 2.18 3.28
Imposed 5.00 + 1.00
= 6.00 9.00
Superimposed dead 0.50 + 0.50 + 0.20
= 1.20 1.79
Total = 9.38 kN/m² 14.07 kN/m²
EFFECTIVE SPAN :
Effective span Le, is the smaller of
1) c/c of supports
2) clear span + slab overall depth - depth to centroid = 1.3 + 110 / 1000 - 20.42 / 1000
= 1.39 m
Therefore Le = 1.39 m
SHEAR RESISTANCE CHECK :
Maximum applied shear = 0.5 * 14.07 * 1.39
= 9.78 kN/m
Shear stress in concrete, v = 0.19 N/mm²
Shear strength of concrete, vc = 0.99 N/mm²
Shear resistance = 131.50 * 89.58 * 0.99 / 225.00
= 52.08 kN/m
UNITY FACTOR = 0.19 PASS
PUNCHING SHEAR CHECK :
Not Applicable
SHEAR BOND RESISTANCE CHECK :
Shear span = 1.39 / 4
= 0.35 m
Applied shear = 7.65 kN/m
Shear bond resistance = 21.93 kN/m
Anchorage resistance = 0 kN/m
Total shear resistance = (21930.1/1000) + [(0/1000)]/2 = 21.93 kN/m
UNITY FACTOR = 0.35 PASS
BENDING RESISTANCE CHECK :
Applied bending moment = 0.125 * 14.07 * 1.39^2
= 3.40 kNm/m
Depth of concrete stress block = 26.32 mm
NOTE: depth of concrete in compression may be limited to 0.45 ds
Tension in decking = 296.07 kN/m
Tension in bar reinforcement = 0.00 kN/m
Depth to position of resultant tension = (0.0 * 80.0 + 296.1 * 89.6) / (0.0 + 296.1)
= 89.58 mm
Lever arm = 76.42 mm
NOTE: lever arm may be limited to 0.95 ds
Compression in concrete
= 296.07 kN/m
Moment resistance = 296.07 * 76.42/1000
= 22.63 kNm/m
UNITY FACTOR = 0.15 PASS
DEFLECTION CHECK :
Allowable deflection ðmax-i under imposed loads, is the lesser of
1) Effective span/350 (= 4.0 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection = 0.013 * 6.50 * (1.39* 1000 )^4 / (205*7710705 )/1000
= 0.2 mm ( < 4.0 mm ) SATISFACTORY
Allowable total deflection ðmax-t, is the lesser of

File Name: v9.0.34.24751


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 5 of 5

1) Effective span/250 or 5.6 mm, and


2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads = 0.2 mm (based on average inertia)
Additional deflection due to superimposed dead loads = 0.0 mm (based on average inertia)
Total deflection = 0.2 + 0.0
= 0.2 mm ( < 5.6 mm ) SATISFACTORY
DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed
Dynamic inertia (cracked section) = 592 cm4
Maximum deflection = 0.013 * 3.98 * (1.39* 1000 )^4 / (205*5917668 )/1000
= 0.16 mm
Frequency = 18 / √ 0.16 )
= 44.96 Hz ( > 5.00 Hz) SATISFACTORY

File Name: v9.0.34.24751