(WHERE OCCURS)
2' MIN.
"W" "A" AT PAVED AREAS OR UNPAVED DRIVES,
85% RELATIVE COMPACTION AT
LANDSCAPED AREAS DETECTABLE WARNING
6"
"W"
TAPE (30" MAX. BELOW
FINISH GRADE)
VARIES
COMPACT TO 92%
RELATIVE COMPACTION Project
4"
PIPE DIA.
PLUS 12"
SLOPE NON-EXPANSIVE 400 NORTH JOHNSON,
HAUNCHING AND INITIAL BEDDING MATERIAL
BACKFILL AREA 92% RELATIVE VISALIA, CALIFORNIA
COMPACT TO 92% RELATIVE COMPACTION COMPACTION
SLOPE VARIES 1.0% MIN. TO
2.0% MAX., SEE PLANS NOTES
VARIES (SEE PLANS) 1. BACKFILL TO A DEPTH OF 12" OVER TOP OF PIPE, FILL SHALL BE PLACED BY HAND AND TAMPED OR AS Prepared For
PER PIPE MANUFACTURER'S SPECIFICATIONS. FOR PLASTIC PIPE INSTALLATIONS, BEDDING SHALL BE
COLD JOINT
IN ACCORDANCE W/PIPE MANUFACTURER SPECIFICATIONS.
2. BACKFILL MATERIAL WITHIN THE HAUNCHING, INITIAL BACKFILL, AND OUTER BEDDING AREAS SHALL BE
HILLMAN BUILDING
DESIGNERS
4"
VARIES, SEE PLANS CATEGORY I, II, OR III MATERIAL (ASTM D2321), PLACED TO 90% REL. COMPACTION.
SLOPE
6" MIN.
CONCRETEE CURB
(WHERE OCCURS) 2.0% MAX., SEE PLANS
SECTION "A-A"
CLEANOT PLUG CAST IRON
FERRULE & BRASS PLUG
1/8" 1/2"
1"
SEALANT LABEL COVER "SEWER" OR
"STORM" AS APPLICABLE LANE ENGINEERS, INC.
1/4" RAD.
(TYP.) 6" TYP. CIVIL STRUCTURAL SURVEYING
1/2" PREMOLDED FINISH GRADE
EXPANSION JOINT
MATERIAL 979 North Blackstone Street
TYPE "D" TYPE "E" Tulare, California 93274
9" MIN.
559.688.5263
TABLE OF SIDEWALK JOINTS
CHRISTY G5 TRAFFIC VALVE BOX www.laneengineers.com
TYPE LOCATION WITH CAST IRON TRAFFIC LID CLASS 3 CONC. COLLAR
All reproduction & intellectual property rights reserved
2022
©
TRANSVERSE JOINT AT INTERVALS EQUAL TO THE SIDEWALK
"D" WIDTH EXCEPT EVERY FOURTH JOINT WHICH IS A TYPE "E" 4" PVC PIPE (UNLESS
JOINT. NOTED OTHERWISE) Professional Seal
FESSION
EVERY FOURTH TRANSVERSE JOINT, P.C AND P.T. OF PRO AL
D V
WA ANG
RE
CURVES, ABRUPT CHANGES IN DIRECTION, AND WHERE NEW
EN
"E" PVC PIPE. SEE
REGISTE
SIDEWALK ABUTS EXISTING SIDEWALK OR OTHER EXIST.
GINE
CONCRETE SURFACE STRUCTURES. PLAN FOR SIZE
ER
PLUGGED WYE AT R.C.E. 73146
NOTES END OF RUNS
1. TYPE "D" JOINT MAY BE EITHER TOOLED IN WET CONCRETE 08/17/2022
CI VIL
IA
ST
OR SAWCUT WITHIN 18 HOURS OF PLACEMENT OF AT
E RN
CONCRETE. O F CA LI FO
2. SIDEWALKS LOCATED IN STREET RIGHTS-OF-WAY SHALL
CONFORM TO CITY STANDARDS AND SPECIFICATIONS.
SIDEWALK CONSTRUCTION NO SCALE 22 SURFACE CLEANOUT (COTG) NO SCALE 12 Description Release Date
EXISTING DOWNSPOUT
NO SCALE
CROSS SLOPE AT
EXISTING SIDEWALK VARIES
j:\Jobs\2021\21154\Dwg\production drawings\CIVIL DETAILS.dwg
NEW SIDEWALK
Drawn by: W.V./T.C
Reviewed by: W.V.
1.5%
1.5%
(EXISTING SIDEWALK)
Sheet Title
C7.1 OF XX