You are on page 1of 1

Concept 

Design Details 

1. Loads 
 In Ground floor – Plaza load and finishes load  
 In other Floors ‐  Office occupancy load  
 
2. Ground floor slab‐ 250mm thick RC with drop size 4500mmx3000mmx500mm 
3. Columns – At building location 500x500‐ to accommodate the steel sections coming from above 
                   At parking locations 250x500  
4. Basement RC wall – 250mm thick 
5. Foundation – 2 options  
 Option 1‐ full raft at building location – 800mm to 1000mm thick raft 
                                 At parking location – 500 mm thick raft 
 Option 2 – At building location‐1000 mm thick Isolated foundations connected with 
250mm slab 
                    At parking location – 500mm thick isolated foundations connected with 
250mm slab 

You might also like