You are on page 1of 4

Project (G+4) Residential Cum Commercial Building

Client Mr.S.T.Vallimuthu
Site T.Nagar

DESIGN OF PILE FOUNDATION(Refer:BH-01 & 02)

1.0 Type of Installation of Pile Bored Cast in Situ


1.1 Geometrical Data
Assumed Diameter of pile(D) : 600.00 mm
Length of Pile : -11.50 m
1.2 Design of Pile for Vertical Compression
1.2.1 Computation of Skin Resistance:

Layer-I
Type of Strata : Clay
Length of strata,lc 7.50 m
Average SPT of the strata,N : 4
Bulk Density of the strata, γ : 20.00 kN/m3
Undrained Shear Strength (Cu) : 26.80 kN/m2
Adhesion, σ : 0.70 kN/m2
Skin Resistance of the pile,qs : 265.08 kN
(q :σ*Cu*pi*d*Ic)

1.2.1.1 Layer-II
Type of Strata : CLAY
Average SPT of the strata,N : 2.00
Bulk Density of the strata, γ : 20.00 kN/m3
Angle of Shearing Resistance - Limited to a Maximum of : 32.00 Deg
tan phi 0.62
Top of Strata : 8.00 m
Bottom of Strata : 10.00 m
Average Thickness of Strata,Ic : 2.00 m
Effective overburden pressure at the middle of the strata,σ middle : 85.00 kN/m2
Coef. Earth Pressure at Rest 0.47
Skin Resistance of the pile,qs : 94.20 kN
(qs: σ *k*tanф *pi()*d*Ic)

1.2.2 Computation of End Bearing Resistance:


Type of Bearing Strata : fine silty sand
Dia of pile : 0.60 m
Cross-Sectional Area of pile,Ap : 0.2826 m2
R.L of bottom of pile : 11.50 m
Minimum SPT-value of the Bearing Strata : 100.00
Angle of internal friction : 32.00
Bearing Capacity Factor(Nq) : 37.00
Effecitve Over Burden Pressure at the bottom of pile (qu): 115.00 kN/m2
Ultimate End Bearing Resistance (Qp) : 1202.46 kN
(Qp=Ap*Nq*qu)
1.3.0 Ultimate Load Carrying Capacity (Qs+Qp) : 1561.75 kN
Safe Load Carrying Capacity (Qsafe =Qu/2.5) : 624.7 kN
say 375 kN
30 31 32
30 33 37

780.8725688229
Project (G+4) Residential Cum Commercial Building
Client Mr.S.T.Vallimuthu
Site T.Nagar

DESIGN OF PILE FOUNDATION(Refer:BH-01 & 02)

1.0 Type of Installation of Pile Bored Cast in Situ


1.1 Geometrical Data
Assumed Diameter of pile(D) : 450.00 mm
Length of Pile : -13.00 m
1.2 Design of Pile for Vertical Compression
1.2.1 Computation of Skin Resistance:

Layer-I
Type of Strata : Clay
Length of strata,lc 4.30 m
Average SPT of the strata,N : 10
Bulk Density of the strata, γ : 20.00 kN/m3
Undrained Shear Strength (Cu) : 26.80 kN/m2
Adhesion, σ : 6.00 kN/m2
Skin Resistance of the pile,qs : 977.00 kN
(q :σ*Cu*pi*d*Ic)

1.2.1.1 Layer-II
Type of Strata : Sand
Average SPT of the strata,N : 23.60
Bulk Density of the strata, γ : 20.00 kN/m3
Angle of Shearing Resistance - Limited to a Maximum of : 32.00 Deg
tan phi 0.62
Top of Strata : 6.00 m
Bottom of Strata : 13.00 m
Average Thickness of Strata,Ic : 7.00 m
Effective overburden pressure at the middle of the strata,σ middle : 78.00 kN/m2
Coef. Earth Pressure at Rest 1.00
Skin Resistance of the pile,qs : 481.78 kN
(qs: σ *k*tanф *pi()*d*Ic)

1.2.2 Computation of End Bearing Resistance:


Type of Bearing Strata : fine silty sand
Dia of pile : 0.45 m
Cross-Sectional Area of pile,Ap : 0.1589625 m2
R.L of bottom of pile : 13.00 m
Minimum SPT-value of the Bearing Strata : 38.00
Angle of internal friction : 32.00
Bearing Capacity Factor(Nq) : 37.00
Effecitve Over Burden Pressure at the bottom of pile (qu): 130.00 kN/m2
Ultimate End Bearing Resistance (Qp) : 764.61 kN
(Qp=Ap*Nq*qu)
1.3.0 Ultimate Load Carrying Capacity (Qs+Qp) : 2223.40 kN
Safe Load Carrying Capacity (Qsafe =Qu/2.5) : 889.4 kN
say 900 kN