FOUNDATION

Total factored load on column = 90 tons = 900kN

Safe bearing capacity of soil = 230 kN/m2

Adopted footing size = 3m x 1.8m

STRAP BEAM
Size = 680 mm x 900 mm

Ast = 25.12 cm2 (8 nos of 25 dia bars)

Asc = 25.12 cm2 (8 nos of 25 dia bars)

Side face bars are also provided.

RING BEAMS
RING BEAM 2 ( At 27’6” level)
Total load of dome = 310 kN/m2

Total load of dome on RB2 ( Ring Beam on which dome is rested through 8 columns) = 310 kN/m2

Load on RB2 at each point through 8 columns = 310/8

Load at each point = 40 kN/m2

Size of RB2 = 230 mm x 450mm

5 nos of 16 dia bars provided each in tension and compression zone.

RING BEAM 4 ( which is connected to dome and resting on 8 columns )


size of RB4 = 230 mm x 380 mm

5 nos of 16 dia bars provided each in tension and compression zone.

ROOF BEAM ( RB3)


Moment = 4000 kN

( moment is greater because of long span roof beams intersecting with each other with no
supported columns, ring beams resting on roof beamsand dome resting on ring beam.

Ast = 122cm2 ( 24 nos of 25 dia bars)

Asc = 58 cm2 ( 12 nos of 25 dia bars)