You are on page 1of 1

PLATE HEAT EXCHANGER TECHNICAL SPECIFICATION

Project: ASA Customer:


Item No: HEX-1 Quote No:
Model: PRE-EP2.07 Date: 02-06-2023

Units Hot Side Cold Side


HEAT EXCHANGED kW 250
MASS FLOWRATE kg/s 2.72 7.45
VOLUMETRIC FLOWRATE m³/h 9.79 26.82
INLET TEMPERATURE ⁰C 40.00 6.00
OUTLET TEMPERATURE ⁰C 18.00 14.00
EFFECTIVE SURFACE AREA Sq.mtr 1.97
PRESSURE DROP(Input/Calculated) bar 0.50 0.05 0.50 0.48
FLUID PROPERTIES
MEDIA Water Water
Inlet Outlet Inlet Outlet
DENSITY kg/m³ 995.50 999.87 999.89 998.65
SPECIFIC HEAT kJ/(kg .⁰C) 4.18 4.20 4.20 4.19
THERMAL CONDUCTIVITY W/(m .⁰C) 0.63 0.57 0.42 0.43
VISCOSITY cp 0.69 1.43 5.90 4.81
LATENT HEAT kJ/kg
MECHANICAL DESIGN AND CONSTRUCTION
LMTD °C 18.11
HEAT TRANSFER COFF. DUTY J/(kg.°C) 4340.51
HEAT TRANSFER COFF. CLEAN J/(kg.°C) 3945.92
LIQUID VOLUME ltr 21.74
PLATE THICKNESS / MATERIAL 0.5 mm / AISI316L
GASKET MATERIAL EPDM HT
MIN. / DESIGN TEMPERATURE ⁰C 0.00 100.00
DESIGN / TESS PRESSURE bar 10.00 13.00
PRESSURE VESSEL CODE PED
FRAME MATERIAL carbon steel
NET WEIGHT kg 79.21
CONNECTION HOT INLET POSITION F1 DN50 Threaded BSP AISI 316
CONNECTION HOT OUTLET POSITION F4 DN50 Threaded BSP AISI 316
CONNECTION COLD INLET POSITION F3 DN50 Threaded BSP AISI 316
CONNECTION COLD OUTLET POSITION F2 DN50 Threaded BSP AISI 316

This Heat Exchanger accuracy is dependent on accuracy of customer data and conformance to specified operating conditions. ©Data
revealed in this document is prorietary intellectual information that may not be copied , reproduced, transmitted, communicated
or disclosed to a third party without the written consent of the Precision PHE Company. The data shall be used for evaluating the
Precision PHE proposal.

Kalpadi,P.O. Kalpadi, K.K. Dist. Tamilnadu,India / Tel:00914651237730 www.precisionstoragevessels.com

You might also like