COMPRESSOR PERFORMANCE

MODEL AZ0413YS 115-127V/60Hz Cooling: Fan


BM AZ445AS Run Cap.: No
1240
37.8
1040 43.3
48.9
CAPACITY IN Watts

840 54.4
60.0

640

440

240

40
-20 -15 -10 -5 0 5 10 15
EVAPORATING TEMPERATURE (°C)

Condensing Temperature (°C) -17.8 -12.2 -6.7 7.2 10.0


37.8 340 413 530 927 1024
43.3 297 372 471 865 957
48.9 257 327 430 791 896
54.4 219 284 389 734 818
60.0 189 257 344 657 754
ASHRAE Test Conditions Tested at: 127V/60Hz Revision Date: March 8,1999
Issued By: Frank Seiki Fukusima Printed on: April 15,2020
COMPRESSOR PERFORMANCE
MODEL AZ0413YS 115-127V/60Hz Cooling: Fan
BM AZ445AS Run Cap.: No
4150
37.8
3650
43.3
3150 48.9
CAPACITY IN BTU/h

54.4
2650 60.0

2150
1650
1150
650
150
-20 -15 -10 -5 0 5 10 15
EVAPORATING TEMPERATURE (°C)

Condensing Temperature (°C) -17.8 -12.2 -6.7 7.2 10.0


37.8 1161 1410 1809 3165 3498
43.3 1013 1270 1609 2953 3268
48.9 878 1117 1470 2700 3059
54.4 749 971 1330 2507 2793
60.0 646 878 1174 2245 2574
ASHRAE Test Conditions Tested at: 127V/60Hz Revision Date: March 8,1999
Issued By: Frank Seiki Fukusima Printed on: April 15,2020
COMPRESSOR PERFORMANCE
MODEL AZ0413YS 115-127V/60Hz Cooling: Fan
BM AZ445AS Run Cap.: No
460
37.8
410 43.3
48.9
360
54.4
POWER IN WATTS

310 60.0

260

210

160

110

60
-20 -15 -10 -5 0 5 10 15

EVAPORATING TEMPERATURE (°C)

Condensing Temperature (°C) -17.8 -12.2 -6.7 7.2 10.0


37.8 189 221 251 300 305
43.3 188 223 258 319 330
48.9 187 228 267 339 353
54.4 186 234 280 364 375
60.0 183 242 294 384 398
ASHRAE Test Conditions Tested at: 127V/60Hz Revision Date: March 8,1999
Issued By: Frank Seiki Fukusima Printed on: April 15,2020
COMPRESSOR PERFORMANCE
MODEL AZ0413YS 115-127V/60Hz Cooling: Fan
BM AZ445AS Run Cap.: No

5,20
37.8
4,70 43.3
CURRENT IN AMPERE

48.9
4,20
54.4
3,70 60.0

3,20
2,70
2,20
1,70
1,20
-20 -15 -10 -5 0 5 10 15
EVAPORATING TEMPERATURE (°C)

Condensing Temperature (°C) -17.8 -12.2 -6.7 7.2 10.0


37.8 3.12 3.37 3.58 4.00 4.04
43.3 3.11 3.40 3.65 4.15 4.19
48.9 3.10 3.43 3.73 4.28 4.31
54.4 3.10 3.48 3.81 4.46 4.57
60.0 3.08 3.51 3.92 4.69 4.81
ASHRAE Test Conditions Tested at: 127V/60Hz Revision Date: March 8,1999
Issued By: Frank Seiki Fukusima Printed on: April 15,2020