Finding : At seamer, the top cover can be opened by hand when a person is standing
Requirement : Access to hazardous movements on the maintenance platform. Height of enclosure measured from standing surface to
top of seamer is 1600 mm, height of rotating parts are 1200 mm but the horizontal
distance is 380 mm, less than required.
MOC :
Corrective action : installed safety sensor on the door to stop the seamer when the door is open.
تركيب حساس فى الباب اوقف الماكينة عند فتح الباب
Rating After: 8
Machine: can Filler Reference : 4.2 Hazard: Mechanical Rating: 5
MOC :
Corrective action : a new handrail is made and toe plate.
تركيب صدادة و مشاية للقدم جديدة فى الساللم
Rating After: 8
Machine: can filler Reference : 3.2 Hazard: Electrical Rating : 5
Finding : Print pocket is full with wiring accessories and booklets of components.
Requirement : Condition of electrical control In control panel, paper sheets, diagrams are laid on the cover of cable storage
panels / cabinets. compartment. For wiring panel located at rear side of filler, paper sheet, wiring
materials and worn parts are put in it.
MOC :
Corrective action : panel is cleaned and tided. تنظيف و توضيب اللوحة
Rating After: 8
Machine: can filler Reference : 3.3 Hazard: Electrical Rating : 5
Requirement : IP protection of electrical control Finding : Cable glands located mounted at rear side of filler are not fastened securely
panels / cabinets. Especially, if the area is nor use bushings with proper sizes to prevent from the ingress of dust/water.
cleaned with water hose.
MOC :
Corrective action : cable glands are well fastened. ريط جالندة االسالك
Rating After: 8
Machine: can filler Reference : 3.4 Hazard: Electrical Rating : 3
Finding : Neutral bus bar and primary side of main disconnector not are finger-safe
Requirement : Access to hazardous circuits (IP2X) protected.
inside electrical control panels / cabinets.
MOC :
Corrective action : insulated the bus-bar فاز3 عزل وصلة الكهرباء ال
Rating After: 8
Machine: can filler Reference : 3.4 Hazard: Electrical Rating : 5
MOC :
Corrective action : properly insulated unused conductors عزل الوصالت الغير مستخدمة
Rating After: 8
Machine: can filler Reference : 3.8 Hazard: Electrical Rating : 5
MOC :
Corrective action : each conductor is on a terminal كل وصلة على ترملة
Rating After: 8
Machine: can filler Reference : 3.8 Hazard: Electrical Rating : 3
Finding : Power input and output of inverters are not connected to protective earthing
Requirement : Protective bonding circuit (PE). circuit.
MOC :
Corrective action : connected the inverters to earthing circuit توصيل ال لوصلة االرضى
Rating After: 8
Machine: can filler Reference : 3.10 Hazard: Electrical Rating : 5
MOC :
Corrective action : a label is with the ampere rating on the outlet
اضافة الصق به رقم االمبير
Rating After: 8