You are on page 1of 3

P70XZETA521B338CL507(V2.05_C77C).

txt
Date of sending : 2018.06.20 Filename : P70XZETA521B338CL507(V2.05_C77C).bin
Rom-ID : P70XZETA521B338CL507(V2.05_C77C)
Type : P70 & P70/P5
System(Control) : P70XZET
Device(Protocol): A521B338 (Pulse+ICT104U)
online upgrade : None
Judgement(Notes): CL507
Checksum : C77C
Currency : CLP
Accepted notes : CH$ 1000(2010~2018)
2000(2009~2012)
5000(2009~2013)
10000(2009~2012)
20000(2009~2011) ( 5 Bills )
Accepted ways : 4

Dip switch settings:


---------------------------------------------
SW1 (SIDE)
---------------------------------------------
1 *OFF OFF OFF OFF ON ON ON ON
2 *OFF OFF ON ON OFF OFF ON ON
3 *OFF ON OFF ON OFF ON OFF ON
CH$ 1000 / 1 2 3 4 5 10 20 100
---------------------------------------------
4 ON : FAST OUTPUT PULSE(LO=50ms/HI=100ms)
* OFF: SLOW OUTPUT PULSE(LO=50ms/HI=300ms)
-----------------------------------------
5 ON : Inhibit Active LOW
* OFF: Inhibit Active HIGH
-----------------------------------------
6 * ON : Accept CH$ 1000
OFF: Reject CH$ 1000
-----------------------------------------
7 * ON : Accept CH$ 2000
OFF: Reject CH$ 2000
-----------------------------------------
8 * ON : Accept CH$ 5000
第 1 頁
P70XZETA521B338CL507(V2.05_C77C).txt
OFF: Reject CH$ 5000
----------------------------------------
9 * ON : Accept CH$ 10000
OFF: Reject CH$ 10000
-----------------------------------------
10* ON : Accept CH$ 20000
OFF: Reject CH$ 20000
---------------------------------------------
* Manufacture setting
Note:(1)Please reset the bill acceptor after any changes on Dip switch.
(2)Dip switches 1 to 5 are only used for pulse protocol.

---------------------------------------------
SW2 (TOP/DOWN)
---------------------------------------------
---------------------------------------|---------------------------------------
ICT104U Interface | Pulse Mode
---------------------------------------|---------------------------------------
1 * ON : Reserved | 1 * ON : Credit-Pulse Normal HIGH
OFF: Reserved | OFF: Credit-Pulse Normal LOW
---------------------------------------|---------------------------------------
2 ON : Pulse Protocol | 2 * ON : Pulse Protocol
* OFF: ICT104U Protocol | OFF: ICT104U Protocol
---------------------------------------|---------------------------------------
3 ON : Reserved | 3 ON : Harness Disable
* OFF: Reserved | * OFF: Harness Enable
---------------------------------------|---------------------------------------
4 ON : Reserved
* OFF: Reserved
-------------------------------------------------------------------------------

* Manufacture setting
Note:(1)Please reset the bill acceptor after any changes on Dip switch.
(2)Dip switches 1 & 3 are only used for pulse protocol.

====================================
| | ICT | Pulse |
|------|-------------|-------------|
第 2 頁
P70XZETA521B338CL507(V2.05_C77C).txt
| BV1 | CH$ 1000 | CH$ 1000 |
| BV2 | CH$ 2000 | CH$ 2000 |
| BV3 | CH$ 5000 | CH$ 5000 |
| BV4 | CH$ 10000 | CH$ 10000 |
| BV5 | CH$ 20000 | CH$ 20000 |
====================================

Bezel LED & Back LED lights display list:

1.Bill Acceptor in the idle state Bezel LED display:


========================================
| Setting | Display |
|--------------------------------------|
| | Colorful light. |
| | The blue light flashes. |
| * | The green light flashes. |
| | No light. |
========================================

2.Bezel LED Errors:


=================================================================================
| LED Flashes | |
|---------------| Status |
| Red | Green | |
|-------------------------------------------------------------------------------|
| | 1 | White Card Calibration. |
| 1 | | Bill Jammed. |
| 2 | | Disable. |
| 3 | | Recognition sensor module error. |
| 3+1 | | Purple sensor error. |
| 3+2 | | Hook sensor error. |
| 3+4 | | Fish sensor error. |
| 4 | | A stringing attempt has detected. |
| 6 | | Stacker error or bill box full. |
| 7 | | Motor error. |
=================================================================================

第 3 頁

You might also like