TYPICAL GIRDER DETAILS GROUND LEVEL GIRDER

DIMENSION LONGITUDINAL REINFORCEMENT STIRRUPS


GIRDER
WIDTH DEPTH I-END MID J-END WEB BARS NO. OF SPACING (mm)
LABEL Ø Ø
(mm) (mm) TOP BOT TOP BOT TOP BOT TYPES *START, 1 @ 50*
GG01 200 400 16 2 2 2 2 2 2 - 1 10 8 @ 100 [A], 8 @ 150 [A], REST @ 200 [A] TO C.L.
GG02 200 400 16 2 2 2 2 2 2 1-16Ø E.F. 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
GG03 200 400 16 3 2 2 2 3 2 - 1 10 8 @ 100 [A], 7 @ 150 [A], REST @ 200 [A] TO C.L.
GG04 200 400 16 3 2 2 3 3 2 1-16Ø E.F. 1 10 8 @ 100 [A], 9 @ 150 [A], REST @ 200 [A] TO C.L.
SECOND LEVEL GIRDER
DIMENSION LONGITUDINAL REINFORCEMENT STIRRUPS
GIRDER
WIDTH DEPTH I-END MID J-END WEB BARS NO. OF SPACING (mm)
LABEL Ø Ø
(mm) (mm) TOP BOT TOP BOT TOP BOT TYPES *START, 1 @ 50*
2G01 250 500 16 7 7 7 7 7 7 1-16Ø E.F. 1 10 9 @ 100 [A], REST @ 200 [A] TO F.E.
2G02 200 400 16 2 2 2 2 2 2 1-16Ø E.F. 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
2G03 200 400 16 3 2 2 2 3 2 1-16Ø E.F. 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
2G04 250 400 16 5 3 3 3 5 3 1-16Ø E.F. 1 10 8 @ 100 [A], 6 @ 175 [A], REST @ 200 [A] TO C.L.
2G05 250 450 16 5 3 3 3 5 3 1-16Ø E.F. 1 10 9 @ 100 [A], 6 @ 150 [A], REST @ 225 [A] TO C.L.
2G06 250 450 16 6 3 3 6 6 3 1-16Ø E.F. 1 10 9 @ 100 [A], 6 @ 175 [A], REST @ 225 [A] TO C.L.
2G07 250 450 16 5 3 3 5 5 3 1-16Ø E.F. 1 10 9 @ 100 [A], 7 @ 175 [A], REST @ 225 [A] TO C.L.
2G08 250 450 16 7 4 4 7 7 4 1-16Ø E.F. 2 10 9 @ 100 [C], REST @ 100 [A] TO. C.L.
2G09 250 450 16 7 3 4 7 7 3 1-16Ø E.F. 1 10 9 @ 100 [A], 6 @ 175 [A], REST @ 225 [A] TO C.L.
2G10 250 500 16 2 2 2 2 2 2 1-16Ø E.F. 1 10 10 @ 100 [A], 1 @ 200 [A], REST @ 250 [A] TO C.L.
2G11 250 500 16 3 3 3 3 3 3 1-16Ø E.F. 2 12 10 @ 100 [B], 3 @ 100 [A], REST @ 250 [A] TO C.L.
2G12 250 500 16 5 4 3 5 5 4 1-16Ø E.F. 2 10 10 @ 100 [C], 3 @ 100 [A], REST @ 150 [A] TO C.L.
2G13 250 500 16 4 4 4 4 4 4 1-16Ø E.F. 2 12 10 @ 100 [C], REST @ 250 [A] TO C.L.
2G14 250 500 16 5 3 3 3 5 3 1-16Ø E.F. 2 12 10 @ 100 [B], REST @ 250 [A] TO C.L.
2G15 250 500 16 7 4 4 7 7 4 1-16Ø E.F. 1 10 10 @ 100 [A], 11 @ 125 [A], REST @ 250 [A] TO C.L.
2G16 300 500 16 7 5 5 7 7 5 1-16Ø E.F. 1 10 10 @ 100 [A], 11 @ 100 [A], REST @ 250 [A] TO C.L.
2G17 300 500 16 8 7 7 8 8 7 1-16Ø E.F. 2 12 10 @ 100 [B], 11 @ 100 [A], REST @ 200 [A] TO C.L.
2G18 350 500 16 9 9 9 9 9 9 1-16Ø E.F. 1 10 10 @ 100 [A], 14 @ 100 [A], REST @ 250 [A] TO C.L.
2G19 200 400 16 2 2 2 2 2 2 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
2G20 250 400 16 5 3 3 5 5 3 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.

1 TYPICAL GIRDER DETAILS GIRDER


LABEL
DIMENSION
WIDTH DEPTH
Ø
LONGITUDINAL REINFORCEMENT
I-END MID
ROOF LEVEL GIRDER

J-END WEB BARS NO. OF


Ø
STIRRUPS
SPACING (mm)
S04 NTS (mm) (mm) TOP BOT TOP BOT TOP BOT TYPES *START, 1 @ 50*
RG01 200 400 16 2 2 2 2 2 2 1 - 16Ø E.F. 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
RG02 200 400 16 2 2 2 2 2 2 - 1 10 8 @ 100 [A], 11 @ 150 [A], REST @ 200 [A] TO C.L.
TYPICAL BEAM DETAILS TYPICAL BEAM SECTION RG03 200 400 16 2 2 2 2 2 2 1-16Ø E.F. 1 10 8 @ 100 [A], 13 @ 125 [A], REST @ 200 [A] TO C.L.
RG04 200 400 16 4 2 2 2 4 2 1-16Ø E.F. 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
RG05 200 400 16 3 2 2 3 2 2 - 1 10 8 @ 100 [A], 5 @ 150 [A], REST @ 200 [A] TO C.L.
RG06 200 450 16 5 4 4 5 5 4 - 1 10 9 @ 100 [A], 8 @ 150 [A], REST @ 225 [A] TO C.L.
RG07 200 400 16 3 3 2 3 3 3 1-16Ø E.F. 2 10 8 @ 100 [B], 4 @ 125 [A], REST @ 200 [A] TO C.L.
BEAM LABELS
DIMENSION LONGITUDINAL REINFORCEMENT STIRRUPS
GIRDER
WIDTH DEPTH I-END MID J-END WEB BARS NO. OF SPACING (mm)
LABEL Ø Ø
(mm) (mm) TOP BOT TOP BOT TOP BOT TYPES *START, 1 @ 50*
B01 200 400 16 3 2 2 2 3 2 - 1 10 8 @ 100 [A], REST @ 200 [A] TO F.E.
B02 200 400 16 3 2 2 2 3 2 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
B03 200 400 16 5 3 3 3 5 3 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
B04 200 400 16 4 2 2 4 4 2 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
B05 200 400 16 5 4 4 5 5 4 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
B06 250 400 16 6 3 3 6 6 3 - 2 10 11 @ 100 [B], REST @ 200 [A] TO C.L.
B07 250 450 16 7 6 6 7 7 6 - 1 10 9 @ 100 [A], 6 @ 200 [A], REST @ 225 [A] TO C.L.
B08 300 450 16 9 5 5 9 9 5 - 1 10 9 @ 100 [A], REST @ 225 [A] TO C.L.
B09 350 400 16 9 9 9 9 9 9 - 1 10 8 @ 100 [A], REST @ 200 [A] TO C.L.
B10 350 500 16 11 11 11 11 11 11 - 2 10 10 @ 100 [B], 11 @ 125 [B], REST @ 250 [A] TO C.L.

5 BEAM AND GIRDER SCHEDULE


S04

2 TYPICAL BEAM DETAILS 3 TYPICAL BEAM SECTION


S04 NTS S04 NTS

SS - SHORT SPAN (Spacing in mm) LS - LONG SPAN (Spacing in mm) REMARKS


MINIMUM WEB BARS AND Thk, t Top Bars Top Bars Extra Top Bars Top Bars Extra 1W - One Way
TYPE OF STIRRUPS SLAB [mm]
øbar
Discont. Cont.
Bottom
Bottom Discont. Cont.
Bottom
Bottom Bars 2W - Two. Way
FASTENING BARS (TBD) (TBC)
Bars (BB)
Bars (EBB) (TBD) (TBC)
Bars (BB)
(EBB) C - Cantiliver Slab
S1 125 10 250 250 250 - 250 250 250 - 1W
S2 125 10 175 175 250 - 250 250 250 - 2W
S3 125 10 200 200 250 - 250 250 250 - 2W
S4 125 10 200 200 250 - 250 250 250 - 1W
CS1 125 10 250 250 - - 250 250 250 - C

7 SLAB SCHEDULE
S04

4 WEB BARS AND STIRRUPS DETAIL


S04 NTS 6 TYPICAL SLAB DETAILS
S04 NTS