Shear Key shall be designed for 1.2 times shear capacity of column As per IS code 800
X X
Shear Capacity in z----z Direction = [ Area of Web x fyw / sqrt(3) ] / γm1 ( Cl. 8.4.1 of IS 800 - 2007 )
= 2109401.6949 N
= 2109.40 KN
Shear Capacity in x---x Direction = [2x Area of Flange x fyw / sqrt(3) ] / γm1
= ( 2 X 307.7 X 32 X 250 / SQRT(3) ) / 1.1
= 2584009.8593 N
= 2584.01 KN
Av = 28000 N/mm2
= N/mm2
Actual Bearing stress in concrete 12.66
= N/mm2
Permissible Bearing stress in concrete 0.45Fck
Design Comp. Strength, Fck = 30 N/mm2
= 13.5 N/mm2
Permissible Bearing stress in concrete
X X
Shear Capacity in X----X Direction = [ Area of Web x fyw / sqrt(3) ] / γm1 ( Cl. 8.4.1 of IS 800 - 2007 )
= 929009.07 N
= 929.01 KN
Shear Capacity in Z---Z Direction = [2x Area of Flange x fyw / sqrt(3) ] / γm1
= ( 2 X 250 X 23.6 X 250 / SQRT(3) ) / 1.1
= 1548348.4492 N
= 1548.35 KN
Av = 16000 mm2
= N/mm2
Actual Bearing stress in concrete 13.27
= N/mm2
Permissible Bearing stress in concrete 0.45Fck
Design Comp. Strength, Fck = 30 N/mm2
= 13.5 N/mm2
Permissible Bearing stress in concrete