Design of Shear Key for Main Columns: UB 914 X 305 X 289

Shear Key shall be designed for 1.2 times shear capacity of column As per IS code 800

X X

1 Along direction Z-----Z

Shear Capacity in z----z Direction = [ Area of Web x fyw / sqrt(3) ] / γm1 ( Cl. 8.4.1 of IS 800 - 2007 )

= ( 824.4 x 19.5 X 250 / SQRT(3) ) / 1.1

= 2109401.6949 N

= 2109.40 KN

= 1.2 X 2109.40 = 2531.28 KN


Therefore, Shear to be resisted by Shear
Key

2 Along direction X-----X

Shear Capacity in x---x Direction = [2x Area of Flange x fyw / sqrt(3) ] / γm1
= ( 2 X 307.7 X 32 X 250 / SQRT(3) ) / 1.1

= 2584009.8593 N

= 2584.01 KN

= 1.2 X 2584.01 = 3100.81 KN


Therefore, Shear to be resisted by Shear
Key

Section to be used as Shear Key: = Plated section symmetrical in both direction


Shear area of section = 350 x 40 x 2 mm2

Av = 28000 N/mm2

Shear capacity of section Vp = Av x fyw / sqrt(3) / γm1


= 3527.09 KN
> 3100.81 KN Shear Key Section
Plate Thk = 40 mm
Full penetration Butt Weld

Check for Bearing:


=
Flange width of section 350 mm
=
Length of section 750 mm
=
Thichness of grout 50 mm
=
Length of section below grout 700 mm

= N/mm2
Actual Bearing stress in concrete 12.66
= N/mm2
Permissible Bearing stress in concrete 0.45Fck
Design Comp. Strength, Fck = 30 N/mm2

= 13.5 N/mm2
Permissible Bearing stress in concrete

Section is safe against Bearing.

Design of Shear Key for Staircase Columns ISWB 600:


Shear Key shall be designed for 1.2 times shear capacity of column As per IS code 800

X X

1 Along direction X-----X

Shear Capacity in X----X Direction = [ Area of Web x fyw / sqrt(3) ] / γm1 ( Cl. 8.4.1 of IS 800 - 2007 )

= ( 600 x 11.8 X 250 / SQRT(3) ) / 1.1

= 929009.07 N

= 929.01 KN

= 1.2 X 929.01 = 1114.81 KN


Therefore, Shear to be resisted by Shear
Key

2 Along direction Z-----Z

Shear Capacity in Z---Z Direction = [2x Area of Flange x fyw / sqrt(3) ] / γm1
= ( 2 X 250 X 23.6 X 250 / SQRT(3) ) / 1.1
= 1548348.4492 N

= 1548.35 KN

= 1.2 X 1548.35 = 1858.02 KN


Therefore, Shear to be resisted by Shear
Key

Section to be used as Shear Key: = Plated section symmetrical in both direction


Shear area of section = 200 x 40 x 2 mm2

Av = 16000 mm2

Shear capacity of section Vp = (Av x fyw / sqrt(3)) / γm1


= 2099.46 KN
> 1858.02 KN Shear Key Section
Plate Thk = 40 mm
Full penetration Butt Weld

Check for Bearing:


=
Flange width of section 200 mm
=
Length of section 750 mm
=
Thichness of grout 50 mm
=
Length of section below grout 700 mm

= N/mm2
Actual Bearing stress in concrete 13.27
= N/mm2
Permissible Bearing stress in concrete 0.45Fck
Design Comp. Strength, Fck = 30 N/mm2

= 13.5 N/mm2
Permissible Bearing stress in concrete

Section is safe against Bearing.