You are on page 1of 2

###

PROJECT: HOUSING LAYOUT-SD-EAST

SLAB ID : S1 AT +3.0 M LVL


Span-Lex)Span-Ley ###
Panal size = 3.500 5.70 ###
fck = 30 N/mm2 ###
fy = 500 N/mm2 ###
###
EDGE COND. 4 TWO ADJACENT EDGES DISCONT. ###
Ly/Lx = 1.63 ###
Loads : ###
Dead load of the slab = D*25 = 2.875 Kn/m2 ###
(Assume D= 115 . 3
Live load = 2.00 Kn/m2 3
Floor finishes = 1.50 Kn/m2
Partitions(if any) = 0.00 Kn/m2
Total load (w) = 6.375 Kn/m2
B.M Coeff. :
a x(-ve) = 0.0320
ax(+ve) = 0.0240
ay(-ve) = 0.0320
ay(+ve) = 0.0240

Design: Moment At 8 tor 10 tor 12 tor


in KNm in m2 mm c/c mm c/c mm c/c
Mx(-ve) = ax(-ve) *w*lx2*1.5 = 3.75 138 273 273 273
Mx(+ve) = ax(+ve) *w*lx2*1.5 = 2.81 138 273 273 273
My(-ve) = ay(-ve) *w*lx2*1.5 = 3.75 138 273 273 273
My(+ve) = ay(+ve) *w*lx2*1.5 = 2.81 138 273 273 273

Clear Cover = 20 mm
d req = SQRT( (Mu*106)/(0.138*fck*b))= = 43 mm
D prov = 115 mm
d prov = 91 mm STEEL CHK DEFL.CHK

BOT. STEEL (AT SPANS) 8 tor @ 125 mm c/c in Shorter direction & O.K SAFE
8 tor @ 125 mm c/c in longer direction O.K

TOP STEEL(AT SUPPORTS) 8 tor @ 125 mm c/c in Shorter direction & O.K
8 tor @ 125 mm c/c in longer direction O.K

Check for Deflection :

Percentage of Tension renforcement @ mid span = 0.44

Area of c/s of steel required


fs =0.58*fy* = 100 N/mm2
Area of c/s of steel provided

Basic span/eff depth ratio for continuous slabs = 32

Modification factor = 2.00


Coefficient for max ratio of span/eff depth = 64

Effective Depth required = 55 < 91 mm


SAFE
###

PROJECT: HOUSING LAYOUT-SD-EAST


###
SLAB ID : S2 AT +6.15 & +9.0 M LVL Ly/Lx
Span-Lex)Span-Ley ###
Panal size = 4.500 4.90 ###
fck = 30 N/mm2 ###
fy = 500 N/mm2 ###
###
EDGE COND. 4 TWO ADJACENT EDGES DISCONT. ###
Ly/Lx = 1.09 ###
Loads : ###
Dead load of the slab = D*25 = 3.125 Kn/m2 ###
(Assume D= 125 . 3
Live load = 2.00 Kn/m2 3 ###
Floor finishes = 1.50 Kn/m2
Partitions(if any) = 0.00 Kn/m2
Total load (w) = 6.625 Kn/m2 ###
B.M Coeff. : ###
ax(-ve) = 0.0320 ###
ax(+ve) = 0.0240 ###
ay(-ve) = 0.0320 ###
ay(+ve) = 0.0240 ###
###
Design: Moment At 8 tor 10 tor 12 tor ###
in KNm in m2 mm c/c mm c/c mm c/c ###
Mx(-ve) = ax(-ve) *w*lx2*1.5 = 6.44 150 300 300 300 ###
Mx(+ve) = ax(+ve) *w*lx2*1.5 = 4.83 150 300 300 300 ###
My(-ve) = ay(-ve) *w*lx2*1.5 = 6.44 150 300 300 300 ###
My(+ve) = ay(+ve) *w*lx2*1.5 = 4.83 150 300 300 300 ###
###
Clear Cover = 20 mm ###
d req = SQRT( (Mu*106)/(0.138*fck*b))= = 56 mm ###
D prov = 125 mm ###
d prov = 101 mm STEEL CHK DEFL.CHK
###
BOT. STEEL (AT SPANS) 8 tor @ 100 mm c/c in Shorter direction & O.K SAFE
8 tor @ 100 mm c/c in longer direction O.K ###
###
TOP STEEL(AT SUPPORTS) 8 tor @ 100 mm c/c in Shorter direction & O.K
8 tor @ 100 mm c/c in longer direction O.K

Check for Deflection : ###


###
Percentage of Tension renforcement @ mid span = 0.50 ###
###
Area of c/s of steel required ###
fs =0.58*fy* = 87 N/mm2
Area of c/s of steel provided ###
###
Basic span/eff depth ratio for continuous slabs = 32 ###
###
Modification factor = 2.00 ###
Coefficient for max ratio of span/eff depth = 64 ###
###
Effective Depth required = 70 < 101 mm ###
SAFE ###