VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 200.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 7.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition


Nocontributing Zone, Ln1=Ln2=Ln3=0.

Drilled Shaft (dia >24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 11.5 0.0 180.7 374.1 0.45 30 0.0 80 5026.5 251.3 2010619.3 20683 11.863
1 12.2 38.0 179.6 788.8 0.29 60 7.0
6 11.7 42.1 0.0 53.5 95.94 60
7 11.7 42.1 0.0 53.5 95.94 60

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 48.56-kN *Soil Weight is not included
Side Resistance (Down)= 3020.961-kN Side Resistance (Up)= 2888.819-kN
Tip Resistance (Down)= 4934.968-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 7955.929-kN Total Ultimate Capacity (Up)= 2937.378-kN
Total Allowable Capacity (Down)= 2651.976-kN Total Allowable Capacity (Up)= 1011.499-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 200.00-kN Settlement= 0.01394-cm
At Xallow= 0.20-cm Qallow= 2504.85815-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.