You are on page 1of 4

input

VERTICALLY LOADED PILES, CARRYING CAPACITY ANALYSIS

0 33 DETAILS
0 0
-0.15 0
-1
-0.15 -15 CAPACITY
-0.15 -30
0 -30
0.15 -30 RESULTS
0.15 -15
0.15 0
0 0
-15.00

-15 0
15 0
D = 0.3 m
P = 309 kN
L = 30 m w.t. = -1 m
0.225 -1
5.1125 -1
10 -1

-30

30m long ⊙ pile


0.3m diameter
Drained Analysis

Page 1
input

Details 1
Soil Details
g 19.2 kN/m³ Unit weight of soil (gamma)

c' (or su) 30.0 kN/m² For undrained soils use phi' = 0

f 18.0 deg Angle of friction (phi')

a 0.5 Adhesion Factor

d 0.5 deg Angle of friction between pile and soil

Water Table 1.0 m Depth to Water Table

Pile Details
Shape ⊙ ⊡ =Square, ⊙ =Circular

Diameter 0.30 m Diameter of pile

Toe Depth 30.00 m Depth to base of pile

Load 309.0 kN Applied load - includes weight of pile

Safety Factors
Base 2.0

Shaft 3.0 SF = 2.5

Page 2
input

Pile Capacity 2

Bearing Capacity Factors


Nq= 2.62
Nc= 9.00
D/L= 100.00

Overburden stress
sigma_b= 291.51 (at Base)
sigma_s= 150.50 (average for Shaft)

Base Bearing Capacity


qu=suNc (for undrained analysis)
qu=cNc+sigma_b*Nq (for drained analysis)

Base (Ab) = 0.07 m²


qu = 1033.09 kN/m²
Qb=qu*Ab Qb= 73.02 kN Base Resistance

Shaft skin friction


fs=alpha.su (for undrained analysis)
fs=c'+Ks.sigma_s.tan(delta) (for drained analysis)

Shaft (As) = 28.27 m²


fs= 30.91 kN/m²
Qs=fs*As Qs= 873.89 kN Shaft Resistance

Page 3
input

Analysis Results 3

Vertical Load
P= 309.0 kN
Ks = 1-sin f
Ks = 0.7 Coefficient of Earth Pressure

Base Resistance
Qb = 73.0 kN

Shaft Resistance
Qs = 873.9 kN

Total ultimate resistance


Qu = Qb + Qs
Qu = 946.9 kN

Allowable Load
Qa =Qb/SFbase+Qs/SFsaft
Qa = 327.8 kN

Overall factor of safety


Qu / P = 3.06

OK Actual Load <= Allowable Load

Page 4