Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static
Profile:
Pile Length, L= 7.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0
Vertical capacity:
Weight above Ground= 0.00 Total Weight= 48.56-kN *Soil Weight is not included
Side Resistance (Down)= 2964.030-kN Side Resistance (Up)= 2843.455-kN
Tip Resistance (Down)= 4651.115-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 7615.145-kN Total Ultimate Capacity (Up)= 2892.014-kN
Total Allowable Capacity (Down)= 2538.382-kN Total Allowable Capacity (Up)= 996.377-kN
OK! Qallow > Q
Settlement Calculation:
At Q= 200.00-kN Settlement= 0.01395-cm
At Xallow= 0.20-cm Qallow= 2721.29077-kN
Note: If program can't find result or the result exceeds the up limits. The result shows 9999.