You are on page 1of 33

Classification: Confidential

Portfolio 2023

Energy Storage System


Classification: Confidential

Company
Development Ranked first among
"China's Top 500 ESG
Installed capacity of Excellent
inverter equipment Enterprises"

Established
exceeded 100GW
globally. National 2021
mission “Clean Industrial Design
power for all” and
vision “ To be the
Center approved and
established
2022
global leader of Successfully develop
clean energy
conversion
2019 the world's
first 35kV solid state
technology” transformer (SST)
2020
2017 Won the “China
No.1 of Global based PV inverter
The First Prize of
Market Share Industry Award”,
Sungrow
Sungrow’s market
National Energy
Science and 2015 2018 value exceeds 100
No.1 of Global Market Technology Sungrow Indian billion RMB
China’s first PV Share Progress factory put into
Concession
Township
Electrification
Bidding Project 2011 2013 2016 production.
Sungrow’s
Expanded to Chinese president annual revenue
Founded by Program
Global Market 2009 Xi Jinping hit 10 billion
Professor Cao
2014 RMB
2002 2006
inspected Smart
1997 National New Energy Power

2012 Enterprise of
Observing
Generation System
of Sungrow
National
2010 Enterprise
Contracts and
Honoring Credit
2008 Shanghai World Technology

1998 2003 Bird’s Nest


Expo, National
Postdoctoral
Center

Southern The first of Beijing Scientific


Xinjiang grid- Olympics Research
connected Workstation
Railway
inverter
Classification: Confidential

Company
Top 10 Business
Renewable energy
PV Inverter investment and development business Energy Storage System

Wind Power Converter NEV Driving System Floating PV System

Electric Vehicle Charging Renewable Hydrogen Production


Smart Operation and Maintenance Intelligent PV Cleaning Robot
Equipment System

Note: It belongs to Sungrow eco-enterprise


Classification: Confidential

Sungrow’s Factories all Around

Yearly Production Capacity

305 GW | FV
280GW (China) + 10GW (India) + 15GW (Thailand)

30 GW/GWh | ESS
THE WORLD’S LARGEST (China)

INVERTER FACTORY
Classification: Confidential

R&D

5.5MW roof top test plant 10M EMC chamber 3MW microgrid test platform

Function and environment test of string &


35kV 16MW high voltage laboratory Battery safety test chambers
residential equipment
Classification: Confidential

ESS Global Supply


UK
0.64 GWh
Germany
US 1.3 GWh
17.8 GWh Japan
Ireland
France
China
0.43 GWh 1.1 GWh
0.26 GWh
2.7 GWh

LATAM
0.76 GWh

Australia
1.2 GWh

Estimated proportion of power Global installed capacity of


86% generated by renewable energy 28.2 GWh BESS in 2021
in 2050

6
Classification: Confidential

Mexico
56 MWh+
Panama
2 MWh+
Suriname
Costa Rica
500kWh+
2.7 MWh+

Brazil
183kWh+
MORE THAN

761 MWh
PROVIDED FOR
Chile
LATIN AMERICA 639 MWh+
Argentina
2 MWh+
Classification: Confidential

Energy Storage System Solutions

Utility ESS AC-Coupled Utility ESS DC-Coupled C&I ESS

Transformer Grid
Lithium-ion battery PCS or Central Inverter
Classification: Confidential

Flexible Configuration
PowerTitan Series Liquid-cooled ESS Full-scenario Solution

LCOS RTE POI Capacity DC/AC Ratio Applications

Support higher Energy Shifting


No change in
Lower Higher DC/AC ratio without Ramp Rate Control
POI capacity loss of energy Clipping Recapture

AC Coupled

Energy Shifting
Increase Yield clipping and Ramp Rate Control
Higher Lower
grid capacity losses Frequency Regulation
Off-grid

DC Coupled
Classification: Confidential

PCS
Advanced Features

100%
0.9PN

-1 +1 96%

92%
-0.9PN
88%
0 0,2 0,4 0,6 0,8 1

Modular Grid Support Synchronous High Voltage Source On-grid mode Quick response
Design Functions Virtual Gen. Efficiency Generator Off-grid mode 0 – 100% < 1seg

Compatible with Grid Codes: UL1741, UL1741 SA, IEEE 1547, or CE, IEC 62477-1, IEC 61000-6-2, IEC61000-6-4
Classification: Confidential

PCS
Main Characteristics

Model SC1200UD SC1375UD SC1575UD SC1725UD SC2000UD SC2500UD

Max DC Voltage 1500V

DC Voltage Range 700-1500V 800-1500V 915-1500V 1000-1500V 1150-1500V 1300-1500V

AC Output Power 1200 kVA 1375 kVA 1575 kVA 1725 kVA 2000 kVA 2500 kVA

Nominal AC Voltage 480V 550V 630V 690V 800V 900V

Max Efficiency 99%

Temperature Range -35ºC ~ 60ºC (> 45ºC derating)

Max Altitude 4000m (> 2500m derating)

Degree of Protection NEMA Type 3R / C5 (Optional)

Dimensions(WxHxD) 1080 x 2400 x 1400mm


Classification: Confidential

PCS
Configurations

1.20~2.5MW
480V - 690V
UL and IEC Version
Outdoor Solution

2400mm
2.75~5MW
MV Station Integrated
UL and IEC Version
20ft Container

5.5~8MW
1400mm
MV Station Integrated
IEC Version
1080mm 40ft Container
PowerTitan SERIES
Classification: Confidential

LIQUID COOLED BATTERIES


Classification: Confidential

P573
57kWh
1P64S
280Ah
LFP
UL9540A / IEC62619
Classification: Confidential

Liquid Cooling Battery Cabinet


2-3 hours

DC-DC Converters
Battery Racks
8 x 175kW

2.752MWh
1.400MWdc
1300V-1500V
26.4 tons

Refrigeration Unit Aux Panel DC Connection Panel


Classification: Confidential

Liquid Cooling Battery Cabinet


4-5 hours

DC-DC Converters
Battery Racks
4 x 175kW

2.752MWh
0.700MWdc
1300V-1500V
26.4 tons

Refrigeration Unit Aux Panel DC Connection Panel


Classification: Confidential

Liquid Cooled Battery Cabinet


10% Longer Battery Service Life, 14% Higher Discharge Capacity

Battery Lifetime Discharge Capacity


1 Evenly-distributed Pipe
10% 14%
21 years
524 GWh
19 years
458 GWh
System-level pipe: even heat Pack-level pipe: even heat
dissipation of all packs dissipation of all cells

2 Cell Temperature Difference ≤ 3℃

vs. Conventional
thermal
Intelligent
liquid-cooling
Conventional
thermal
Intelligent
liquid-cooling
management temperature management temperature
control control
Cell temperature difference of Cell temperature difference of
PowerTitan ≤ 3℃ conventional ESS ≤ 10℃

Remarks: 100 MWh, 0.5C, 1 cycle per day, 65% EOL


Classification: Confidential

Liquid Cooled Battery Cabinet


Highly Integrated, Reduced LCOS

Early installation: Reduce installation time by 50%


• Install batteries and PCS wires before shipment
• Complete installation of a single cabinet within 8 hours.

Battery pack installation

PCS and transformer wiring

PCS with integrated Battery Unit


Back-to-Back Installation
MV transformer
Classification: Confidential

Power Titan Series


PowerTitan
High LCOE
Conventional ESS
Large area, high High thermal management
installation cost power consumption, short Service life
battery service life up by 10%
Occupied area Consumption
down by 32% down by 40%

Smaller area Lower consumption,


Single door and open from front longer service life
Support back-to-back and Intelligent liquid-cooling
side-by-side layout temperature control
Extreme even heat dissipation

Inconsistent charge Difficult O&M Discharge capacity


and discharge O&M cost
up by 7%
RTE up by 3% Down by 1 million/year

High discharge capacity Smart O&M


Intelligent cluster-level management SOC auto balancing
Energy efficiency optimizatiom Easy system upgrade

Remarks: 100 MWh, 0.5C, 1 cycle per day, 65% EOL


Classification: Confidential

Enhanced System Safety


PowerTitan
Frequent Accidents
More than 50 explodes and fires occurred in energy
storage systems around the world in the last 10 years.
Professional Integration and
Comprehensive Protection
The entire system is designed and produced by
SUNGROW with unified design, safety standard,
and control logic, providing end-to-end protection.

AI-powered Cell Health Monitoring


Calculate the voltage, lithium plating, and other
data during cell operating, monitor cell safety in
real time, and give early warnings.

Electrical Safety Protection Design


Multi-level electrical breaking design, achieving
current breaking within microseconds and
reducing the overcurrent risk on the DC side.

◼ Improper system ◼ Delayed warning


integration about cell
Main System Fire Safety Design
◼ Insufficient exceptions Meet the North American NFPA855/69/68/15 design
causes requirements, effectively preventing thermal
electrical system ◼ Insufficient runaway and reducing system loss.

protection thermal runaway

* Source: chuneng.bjx.com.cn control


Classification: Confidential

Enhanced System Safety


AI-powered cell health
calculation Real time monitoring Faulty cell early warning

Intelligently identify
unhealthy cells
SOC Measuring error

Temperature Current
Voltage
Electrochemistry
Ohmic Polarization internal
resistance resistance
Concentration
polarization
Internal resistance

Deviation analysis based on internal resistance Comprehensive evaluation of Early warning of short circuit, rapid
multiple parameters capacity degradation, and voltage sag

AI-powered cell health monitoring: Perform high-precision online computing for cell status
data and give warnings if the result is abnormal.
Classification: Confidential

Enhanced System Safety


Multi-level Multi-level
Current Control Protection Less Loss
Lower short circuit Reduce fuse damages
Quicker and more sensitive
current by 2/3

Break the busbar in MEPT built-in fuse Combiner box fuse DC-side fuse of PCS
the pack Short circuit protection for Busbar short circuit Own short circuit
Quick isolation connection lines protection protection
Classification: Confidential

Enhanced System Safety

Dry Pipe
Gas Detector +
Automatic gas vent
Water

Fire detection, automatic gas


ventilation and sprinklers
Gas detector
increase system safety

Fire wall
1 Hour rated Fire-
resistant Walls
Smoke Detector
Slow fire spread helps first
responders and protects
assets
Classification: Confidential

Enhanced System Safety


Combustible Gas Detection + Compliance with NFPA855/69/68/15
Auto Start of Fire Suppression, Reducing Standard for the Installation of Stationary ESSs

Losses World's first international safety standard for ESSs put forward by the
Combustible gas detector National Fire Protection Association
Exhaust outlet
Water pipe Smoke detector

Thermal detector
Standard Requirement PowerTitan

• Smoke detector

• Thermal detector

• Combustible gas detector

• Exhaust system

• FSS: Aerosol/water FSS


Early detection, continuous cooling, prevent re-ignition

* UL9540A safety certificate


Classification: Confidential

5 GWh of Global PowerTitan Contract,


with a Total of 2 GWh Shipment
PowerStack SERIES
Classification: Confidential

LIQUID COOLED BATTERIES


Classification: Confidential

PowerStack Series
C&I Liquid-cooled ESS Innovative Integration,
Increasing Efficiency and Cutting
Cost

BSS:ST535kWh or Profits
PCS:SC250kW increased by 10%
ST1170kWh
Fine energy management

System service
life Consumption
extended by 2 drops by 30%
years

Less cell temperature difference


with intelligent liquid-cooling
temperature control

O&M cost
80% less O&M workload
Simple system upgrade, flexible
wiring,
and auto liquid replenishment
Classification: Confidential

PowerStack Series
Smart O&M, Cutting Manual Workload

Quick Upgrade: Less Upgrade Workload Online Monitoring: Less Inspections

Temperature

• Online monitoring of liquid-cooled


system
Intelligent management

BMS PCS Local controller


• Warning of liquid leakage
Liquid
• The local controller supports batch upgrade for all units of the ESS.
pressure

Flexible Installation: Less Installation Time Dynamic Coolant Replenishment:


Less Replenishment Workload

Conventional: SUNGROW:
• No frequent manual coolant
Wiring must go Allow wiring on the
from the bottom. side or bottom. replenishment
Underground wiring No need for
is required underground wiring • Keep the optimal thermal management
Classification: Confidential

Enhanced System Safety

Multi-level
Protection
Quicker and more sensitive

In-cluster fuse Fuse inside the BCP switch box Fuse on the PCS DC side
Break the busbar Loop short circuit Short circuit protection for Own short circuit
in the pack protection connection lines protection
Quick isolation
Classification: Confidential

PowerStack Series
C&I Liquid-cooled ESS
System service life Discharge capacity

1 Evenly-distributed Pipe extended by increases by

2 years 14%

17 years

15 years

Pack-level pipe: even heat System-level pipe: even heat


dissipation of all cells dissipation of all packs

2 Cell Temperature Difference ≤ 2.5℃

vs. Conventional
thermal
Intelligent
liquid-cooling Conventional
thermal
Intelligent
liquid-cooling
temperature temperature
management management
control control

Cell temperature difference of Cell temperature difference of


PowerStack ≤ 2.5℃ conventional ESS ≤ 10℃

Remarks: 0.5C, 1 cycle per day, 65% EOL


Classification: Confidential

Ensure Safety
System fire suppression design: Detect fire, smoldering, smoke, and high
temperature, and automatically start venting and aerosol/water extinguishing.

Combustible Gas Detection, Less Accident Loss


NFPA855/69/68/15 Safety Requirements
• Intelligently detect fires to • Quickly exhaust to release
avoid accidents the pressure and start water
extinguishing
Standard Requirement PowerStack

• Smoke detector

• Thermal detector

• Combustible gas detector

• Exhaust system

• Water FSS

UL9540A safety certificate


Classification: Confidential

PowerStack Storage Solution


LC

SCADA

Meter Inverter PCS

DC
AC
Communication

Load Module ESS

Energy Shifting PV & Storage Micro-grid Demand Management Backup


Self-consumption
Classification: Confidential

THANK YOU!

33
2022 Copyright © SUNGROW.Confidential