4.7 HO AND LO PURIFIER ALARM LIST

Alarm Cause of alarm Process


1. Bowl failed to close due to the 1. Refer to separate "Maintenance
Selfejector failure. manual"
2. Operating water to close the Bowl
was not supplied due to the Solenoid 2. Repair or replace with good
valve SV2 defective open. quality spare.
3. Required Sealing Water was not
supplied due to the Solenoid Valve 3. The same as above.
SV3 defective open.
Oil leakage
4. Rated quantity of sealing water has
(Leak)
not been supplied because the setup 4. Adjust the setup time of the
time of sealing water T603 too short. timer.
5. Solenoid valve SV2 or SV3 did not 5. To replace output module.
open due to defective Output
Module of Programmable Controller. 6. Refer to separate "Maintenance
6. Due to failure of Leakage Monitor. manual"
7. Due to failure of Water or Air line. 7. As Above

1. Bowl did not open due to failure of 1. Refer to separate "Maintenance


Selfejector. manual"
2. Operating Water to open the bowl
No opening was not supplied due to SV1 2. Replace with spare.
of bowl defective.
(No Dis) 3. Solenoid valve SV1 did not open 3. To replace output module.
due to defective Output Module of
Programmable Controller. 4. Refer to separate "Maintenance
4. Failure of Sludge Discharge Monitor. manual"
5. Failure of the Water or Air line 5. As above
1. To replace battery within 10
1. Voltage drop of the battery in
days. If unable, ensure power to
(BATT) programmable controller
control panel must not be put off.

 In case Separator is run as Clarifier, Water Detection System (HIDENS) must


be used. Following are HIDENS system alarms.

Alarms Causes Action


Abnormal
Water content unusually high Remove the water or causes
water content
(LED 5) Preset value is not proper Change the preset value in
accordance to paragraph 15.6.2 (2)
A-Class Vessels Machinery Operating Instructions
Section 4
Page 13
Revision 1.0
01.08.04

Discharge signal of Separated Water is Inspect the Control Part (Relay RY1)
not given of Water Detector
Discharge of Separated Water is not Inspect the Control Panel of Oil
properly conducted Purifier or Oil Purifier itself
CPU
Trouble of CPU-IC abnormality of bus Replacement of printed Circuit
abnormal
line trouble of memory IC Board
(LED 6)
A/D
Converter Replacement of printed Circuit
Trouble of A/D Converter IC
Abnormal Board
(LED 7)