Date: 02.09.2022 Slope Stabilization System
Edition: 5

Subject to change without


notice.

© Geobrugg AG
CH-8590 Romanshorn
Range of application

This Appendix to the Product Manual should is the extension with the TECCO® STAINLESS System and
the changes in installation. Basis is the current System Product Manual for the TECCO ® slope stabilization
system.

This appendix is only valid in combination with the most recent edition of the TECCO ® “Slope Stabilization
System Product Manual”. In the Product Manual, the entire process of installation, with every possible de-
tail needed, is described.

Product Liability Clause

Rockfall, landslides, debris flows or avalanches are sporadic and unpredictable. Causes can be e.g. human (construc-
tion, etc.) or environmental (weather, earthquakes, etc.). Due to the multiplicity of factors affecting such events it is not
and cannot be an exact science that guarantees the safety of individuals and property.

However, by the application of sound engineering principles to a predictable range of parameters and by the implemen-
tation of correctly designed protection measures in identified risk areas the risks of injury and loss of property can be
reduced substantially.

Inspection and maintenance of such systems are an absolute requirement to ensure the desired protection level. The
system safety can also be impaired by events such as natural disasters, inadequate dimensioning parameters or failure
to use the prescribed standard components, systems and original parts; and/or corrosion (caused by pollution of the
environment or other man-made factors as well as other external influences).
Manual-Appendix TECCO® STAINLESS
Page 3 / 12

1. TECCO® STAINLESS elements of the system

High-tensile steel wire mesh TECCO® STAINLESS

Technical Data TECCO® G45/2 STAINLESS TECCO® G65/3 STAINLESS

Wire diameter 2 mm 3 mm

Tensile strength of steel wire ≥ 1‘650 N/mm2

Tensile strength of steel wire mesh ≥ 75 kN/m ≥ 140 kN/m

Diagonal 62 x 95 mm 83 x 143 mm

Mesh width 48 mm 65 mm
Number of meshes transversal 16.1 pcs./m 12 pcs./m
Number of meshes longitudinal 10.5 pcs./m 7 pcs./m

Weight per m2 1.1 kg/m2 1.65 kg/m2

Corrosion protection STAINLESS (INOX) 1.4462 (AISI 318)


Bearing resistances with Spike plate P33
Bearing resistance of the mesh against punc-
turing DR 100 kN 170 kN

Bearing resistance of the mesh against shear-


ing-off at the upslope edge of the spike plate 50 kN 85 kN
PR
Bearing resistance of the mesh against slope-
parallel tensile stress ZR 10 kN 25 kN

TECCO® G65/3 STAINLESS mesh made from high-tensile steel wire with knotted ends.

© Geobrugg AG, CH-8590 Romanshorn, Switzerland


Manual-Appendix TECCO® STAINLESS
Page 4 / 12

System spike plate P33 STAINLESS

Technical Data Spike plate P33/40 N, Spike plate P33/50 N

Size 330 x 205 mm

Thickness 7 mm
Hole diameter 40 mm / 50 mm
Length of the spikes min. 20 mm
Weight 2.2 kg
Geometry diamond
Longitudinal bending resistance ≥ 2.5 kNm
Steel quality STAINLESS (INOX) 1.4404 (AISI 316L)

System spike plate P33

Isolation bushing

Technical Data Isolation bushing ø50/38/34 x 55 mm Isolation bushing ø60/48/42 x 55 mm

Execution: For spike plate P33/40 consistent with For spike plate P33/50 consistent with
GEWI NG25/NG28 GEWI NG32, TITAN 40

Application purpose: These optional plastic bushings isolate the nail from the mesh and spike plate. There-
fore, for example instead of stainless nails normal galvanized nails can be used.

Material: Polyamide, black

Example isolation bushing for spike plate P33/50

© Geobrugg AG, CH-8590 Romanshorn, Switzerland


Manual-Appendix TECCO® STAINLESS
Page 5 / 12

Press claws

Technical Data Press claws type 1 (small) Press claws type 2 (big)

Application purpose Connection elements to interlink the indi- Connection elements to fasten the
vidual mesh sheets TECCO® mesh at the boundary rope
TECCO® G65/3 STAINLESS

Execution Open eyelet for compression after installation on site

Material quality ø 6 mm steel wire

Corrosion protection STAINLESS (INOX) 1.4462 (AISI 318 LN) STAINLESS (INOX) 1.4401 (AISI 316)

Press claw type 1 Press claw type 2

Connection Clip TF

Technical Data

Application purpose connection elements to interlink the individual mesh sheets


TECCO® G45/2 STAINLESS

Execution open eyelet for installation on site by hand

Material quality ø 3 mm steel wire

Corrosion protection STAINLESS (INOX) 1.4462 (AISI 318)

Connection Clip TF

© Geobrugg AG, CH-8590 Romanshorn, Switzerland


Manual-Appendix TECCO® STAINLESS
Page 6 / 12

Boundary rope

Technical Data

Application area For fastening and reinforce the edge areas

Type Steel wire rope D = 12 mm


Minimum breaking force 82 kN

Corrosion protection STAINLESS (INOX) 1.4401 (AISI 316)

Boundary rope

Wire rope clip

Technical data

Application area The free ends of the wire ropes should be fastened with wire rope clips. Care
must be taken that a special graphite grease is used to prevent the nut to be
stucked.

Corrosion protection STAINLESS (INOX) 1.4401 (AISI 316)

Installation TECCO® G65/3 STAINLESS in Great Western Beach, England

© Geobrugg AG, CH-8590 Romanshorn, Switzerland


Manual-Appendix TECCO® STAINLESS
Page 7 / 12

2. Changes in the installation

General
Any contact of stainless steel with black steel during transport, storage and installation should be avoided.

Vertical mesh connection


The mesh sheets can be laid out without overlap at the side.

The mesh sheets must be connected lengthwise (normally in the line of the slope) as illustrated below.

TECCO® G45/2 STAINLESS


Hereby each individual edge-mesh must be secured with one connection clip TF to the neighboring mesh. Therefore,
there are 10.5 connection clips TF per meter needed.

without overlap overlap = 2 diamond openings

TECCO® G65/3 STAINLESS


Hereby each individual edge-mesh must be secured with two press claws type 1 to the neighboring mesh. Therefore,
there are 14 press claws type 1 per meter needed.

without overlap overlap = 2 diamond openings

By this arrangement it is guaranteed that the lateral connection of the mesh sheets provides the transverse tensile
strength of the mesh, and that the deformations under load are limited.

© Geobrugg AG, CH-8590 Romanshorn, Switzerland