Built-in refrigerator 950w*660d*1760h 0

NB: Fridge to be Purchased by Individual Home Owner 940 600

Pendant Lights above island


to I.Ds approved sample

Built-in microwave 600w*400d*400h


NB: To Be Purchased By
Developer
0
600 400
Built-in oven 600w*600d*590h
NB: To Be Purchased By Developer

1,200
900
Tile Skirting to match floor finish

MAIN KITCHEN K-01 DETAIL


DRAWINGS
C ELEVATION - C
SCALE 1:15
SRN-105

NOTES FIRE FIGHTING FIRE SYMBOLS NOTE : All dimensions are to be reconfirmed on site
Client.
ARCHITECTURAL 1. Provide 4no. 9 litres fire extinguishers next to each hose reel. Revision Describtions : Revised by: Date revised : Revision No: Status :
7. All inspection chambers in drive area to have heavy duty covers. CONSTRUCTION STRUCTURAL. EXIT 8w maintained 'EXIT' sign
1. All work to be carried out in accordance with council regulations & the building 2. Provide emergency light in the staircase.

PRESENTATION
DR. JAMES MWANGI 8. Check all dimensions on site. 1].All slabs concrete at ground level to be poured over 1]. All black cotton soils to be removed from below all building and paved surfaces. s Smoke Detectors
code 3. Provide automatic alarm to cover the project. Job No: Scale :
1000 gauge polythene sheeting on 50mm thick stone 2]. Building to be clear of all black cotton soils to a distance of 3m outside perimeter .

DRAWINGS
9. All sanitary work to be in accordance with MoH rules and H Heat Detectors DO NOT SCALE FROM DRAWING .USE FIGURED DIMENSIONS ONLY .
2. Dimensions to be read and not scaled off the drawing. The contractor must 4. Provide 1200 litre water reserve tank for hose reel. #Pln
Project Title. regulations. dust on hardcore. 4]. All paved surfaces to be clear of all black cotton soils to a distance of 500mm outside (A3)
check and verify all dimensions on site before commencement of any work. 5. Provide smoke and heat detectors to all floors. Fire Alarm
10. 500g polythene sheeting and anti-termite treatment to be under 2].All soils under slabs and all around external the edge of the surface.
PROPOSED RENOVATION WORKS. 3. All walls below 200mm to be reinforced with hoop iron at every alternative 6. To comply with requirement of NFPA regulations. Drawing No. Rev. No.
KATANI, SYOKIMAU basement floor concrete. foundation to be treated for termites. 5]. For all R.C works , refer to Structural Engineer's details.
course. 7. Provide fire engine access & dry riser inlet 30m hose reel
11. All reinforced concrete work is to be in accordance with 3. All conduits must be laid before plastering. 6]. Depth of foundation to be determined on site to S.E's approval. #LayID
4. Provide damp proof course (D.P.C) under all walls. 8. Fire instruction manuals to be located at entrances. SUBMITTED BY: VICTOR KIM KIPTUM
Drawing Title.
structural engineer's details. 4. All electrical work must be co-ordinated with 7]. All walls less than 200mm thick to be reinforced with hoop irons at every alternate
5. P.V. indicates permanent ventilations. 9.A hobby automatic booster pump complete with pressure vessel and presure switch shall be provide.
12. All electrical work to be carried out by a lincenced electrician to mechanical works. course. REG. NO: A-1779
Drawn by: Checked by: Date:
6. All drainage passing under building and drive area to be of PVC pipe and 10. Fire hydrants will be serviced on a water reticulation of 100mm dia. G.I piping class "B" with 3No. fire hydrants.
the local authority. 5. Any conflicts must be clarified before works begin. 8]. All adjacent R.C works and masonry walls to be tied with straps irons at every course WANGARE MARTIN 24/04/2023
encased in concrete. 11. Exit signs to be installed above all external doors. W.M