You are on page 1of 1

Ref Des Description Manuf/Part Number

MC-1 RO Pump Motor Contactor LS MC22b, 220Vcoil


TOR1 Motor Thermal Overload (16-22A) LS MT-32-19
BRANCH CIRCUIT PROTECTION
MUST BE PROVIDED EXTERNALLY
208-240 VAC, 60HZ,
1 PHASE
L1 L2
I CONTROLS
TB-5 CIRCUIT BOARD
Ground E13
Power IN L2 E12
Power IN L1 E11
L1
(Fused 6A) Power Out L1 E24
L2
Pump A2 E23
A1 A2
Pump A1 E22 MC1
(switched with Pump)Aux A1 E21
Coil
Feed Pump A2 E112
Feed Pump A1 E111 1 2
Divert Valve L2 E53
Divert Valve/Alarm (NO) L1 E52
208-240 VAC for MC1
Divert Valve/Alarm (NC) L1 E51
Hanna Meter
Feed Valve L2 E43
Contactor L2
Feed Valve (NO) L1 E42
Feed Valve (NC) L1 E41
TOR1
Flush Valve L2 E32
Flush Valve L1 E31 Thermal
Overload
Low Pressure Switch E102
Feed Pressure Switch
Low Pressure Switch E101
Pretreat Switch E92

Single
Pretreat Switch E91
Tank High Switch E82

Level Switch
Tank High Switch M1
Tank High Switch E81 AC Motor
Tank Low Switch
E72 2P
Tank Low Switch
Tank Low Switch
E71

Dual
High Pressure Switch
E62
High Pressure Switch
High Pressure Switch
E61
TITLE:
NAME DATE SC-A-6K-DBL ELEC
Single Tank Switch Connection

Single
DWG BY S.P. 12-20-18 SIZE DWG NO. REV
E82
ENG APPR. S.P. 12-20-18 A SC-A-6K-DBL-ELE-01-A A
E81

Switch
Level
Type Description QA SCALE: NONE SHEET 1 OF 1
Fuse# Value Where Used E72
E71 PROPRIETARY AND CONFIDENTIAL:

Dual
F1 6A 5x20mm Littelfuse 234006 or equiv. TB-5
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOCAL WATER DESIGN LLC. ANY REPRODUCTION IN PART
OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOCAL WATER DESIGN LLC IS PROHIBITED.
F2 0.25A 5x20mm Littelfuse 218.250 or equiv. TB-5

You might also like