Professional Documents
Culture Documents
hySPAN
solutions
range
Fully supported by
Engineered to Perform
hySPAN Structural LVL is available in two complementary ranges delivering
both softwood and hardwood alternative beam solutions. hySPAN PROJECT
and hySPAN+ are easy to work with using traditional building tools and are
clearly branded for easy identification and your guarantee of quality.
SPAN
Load Widths
Roof load width (RLW) and Floor load width (FLW) can be determined from AS1684, or from the images below.
FLOOR
JOISTS
BEARER ‘C’
= RLW
=
RLW RLW
= SUPPORT
SUPPORT SUPPORT =
= R2
R1+
RLW = 2
= RLW
R2
SUPPORT SUPPORT R1
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
Minimum bearing = 50 mm at end supports and 100 mm at internal supports for continuous span members.
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
4
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
Minimum bearing = 50 mm at end supports and 100 mm
at internal supports for continuous span members.
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
5
SPAN (m) O/H (m) SPAN (m) O/H (m) SPAN (m) O/H (m) SPAN (m) O/H (m)
90 x 35 1.6 0.4 1.6 0.3 1.9 0.4 1.8 0.3
90 x 45 1.8 0.5 1.7 0.4 2.1 0.5 2.0 0.4
130 x 35 2.4 0.7 2.3 0.6 2.9 0.7 2.7 0.6
130 x 45 2.7 0.8 2.5 0.7 3.2 0.8 3.0 0.7
150 x 35 2.8 0.8 2.7 0.7 3.4 0.8 3.2 0.7
150 x 45 3.1 0.9 3.0 0.8 3.8 0.9 3.5 0.8
170 x 35 3.3 0.9 3.1 0.9 3.9 0.9 3.7 0.8
170 x 45 3.6 1.0 3.4 0.9 4.4 1.0 4.0 0.9
200 x 45 4.4 1.2 4.1 1.1 5.2 1.2 4.8 1.1
240 x 45 5.2 1.5 4.9 1.3 6.1 1.5 5.6 1.3
300 x 45 6.1 1.7 5.7 1.6 7.1 1.7 6.6 1.6
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing = 30 mm at end supports and 45 mm at internal supports for continuous span members.
Floor Rigidity
In the selection of floor joist size for a given span, specifiers should use the above maximum joist spans for guidance and in
addition take into account the intended occupancy or use of the floor. Floors supporting partition walls, those constructed using
more rigid flooring or including ceiling battens will have improved dynamic performance. These factors may also be taken into
consideration in selection of floor joist size.
Overhanging Balconies
Overhangs detailed above have been designed to support balcony live loads. Overhanging floor joists used for balconies should
either be totally weather protected or preservative treated to H3 level and painted or stained. Refer durability requirements as noted
on Page 2 of this brochure.
SPAN
OVERHANG
JOISTS WITH D/B>4 REQUIRE
LATERAL RESTRAINT
AT SUPPORTS – REFER
AS1684.2 CL 4.2.2.3
END TRIMMER
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
6
Floor joists supporting parallel load bearing walls over large spans can deflect excessively even if the ‘rule of thumb’ practice of
doubling joists is followed. The following tables give maximum spans for double joists for various roof loads. Roof load width may
be determined by reference to the diagrams on page 3.
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing = 30 mm at end supports and 45 mm at internal supports for continuous span members.
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
7
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing 35 mm at end supports unless noted otherwise as SPAN(BEARING).
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
8
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing 35 mm unless otherwise denoted as SPAN(BEARING).
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
9
2400 SETBACK
SHEET ROOF AND CEILING TILE ROOF AND CEILING
hySPAN
SECTION TRUSS SPAN (m) TRUSS SPAN (m)
DxB 6.0 9.0 12.0 6.0 9.0 12.0
(mm)
MAXIMUM SPAN (m) MAXIMUM SPAN (m)
130 x 45 1.9 1.7 1.3 1.3 1.1 0.9
150 x 35 2.0 1.8 1.4 1.4 1.2 (45) 1.0
150 x 45 2.2 1.9 1.6 1.6 1.3 1.2 (45)
170 x 35 2.2 2.0 1.7 1.6 1.4 (45) 1.2
170 x 45 2.5 2.1 2.0 1.8 1.6 2.0 (45)
200 x 45 3.0 2.5 2.4 2.2 1.9 (45) 1.7
200 x 63 3.2 2.9 2.6 2.5 2.2 1.9
2/200 x 45* 3.6 3.2 3.0 2.8 2.5 2.3
240 x 45 3.5 3.2 2.9 2.7 2.4 (45) 2.2 (70)
240 x 63 3.8 3.4 3.2 3.0 2.7 2.4 (45)
2/240 x 45* 4.2 3.8 3.6 3.4 3.1 2.8
300 x 45 4.1 3.7 3.5 3.3 3.0 2.7 (45)
300 x 63 4.4 4.0 3.8 3.6 3.3 3.1 (45)
2/300 x 45* 5.0 4.5 4.2 4.0 3.7 3.4
360 x 63 5.1 4.7 4.4 4.2 3.8 3.6 (70)
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing 35 mm unless noted otherwise as SPAN(BEARING).
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
LINTEL
SUPPORT
750 750
TRUNCATED
GIRDER TRUSS
JACK TRUSS
LINTEL
LINTEL SPAN
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
10
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
OR
D/
N A N PA N
L I S
UR A M
RP BE
DE NG
UN NGI L2 UNDERPURLIN
R HA
D/O
AN AN
IN M SP
RL
R P U BE A
DE NG
UN NGI L1
HA
HANGING BEAM/
UNDERPURLIN SPAN
(L1 + L 2)
= 2
HANGING STRUTTING
ST BEAM BEAM
RU
TT
ING
BE LINTEL
AM
SP
AN
AN
SP
T EL
L IN
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
11
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
#
Overhang (O/H) applies for birdsmouth not exceeding D/3 – see Detail H12 (page 26).
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
12
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
#
Overhang (O/H) applies for birdsmouth not exceeding D/3 – see Detail H12 (page 26).
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
13
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
SUPPORT
HIP RAFTER
NOTE
1. USE THE LARGEST SPAN (L1 OR L2) TO ENTER THE TABLE.
2. T HE LARGEST SPAN SHOULD NOT BE GREATER THAN TWICE THE ADJACENT
SPAN, OTHERWISE USE THE SINGLE SPAN TABLE.
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
14
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Install permanent batten at mid span at top of all joists and braced back to a point of rigidity to prevent rollover under construction and
maintenance loads.
ˆ Ceiling joists not fixed to rafters require blocking at supports to prevent rollover.
CEILING JOISTS
OVERBATTEN
MIN 70mm X 35mm F5 PINE
AN
SP
SP
AC
ING
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
15
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
HANGING BEAM
CEILING JOISTS
HA
NG
ING
BE L2
AM
SP
AN
+L2
L1
L1 2
=
W
CL
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
16
L1
L1 + L 2
RLW =
2
L2
UNDERPURLIN
STRUT
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
17
SHEET ROOF
hySPAN
SECTION ROOF AREA (m2)
DxB 6.0 9.0 12.0 15.0 18.0
(mm)
MAXIMUM SPAN (m)
170 x 63 3.7 3.1 2.7 2.4 2.0
200 x 63 (E) 4.7 3.9 3.4 3.1 2.8
2/200 x 35* 4.8 3.8 3.2 2.8 2.5
2/200 x 45* 5.4 4.6 4.0 3.7 3.4
240 x 63 (E) 6.0 5.1 4.5 4.0 3.7
2/240 x 63* 7.0 6.4 6.0 5.5 5.1
300 x 63 (E) 7.3 6.6 6.1 5.5 5.1
2/300 x 45* (E) 7.9 6.9 6.1 5.5 5.0
360 x 63 (E) 8.5 7.7 7.2 6.6 6.0
400 x 63 (E) 9.2 8.5 7.9 7.1 6.4
450 x 63 (E) 10.1 9.3 8.3 7.5 6.9
TILE ROOF
hySPAN
SECTION ROOF AREA (m2)
DxB 6.0 9.0 12.0 15.0 18.0
(mm)
MAXIMUM SPAN (m)
170 x 63 2.5 2.1 1.8 1.6 1.5
200 x 63 (E) 3.2 2.6 2.3 2.0 1.9
2/200 x 35* 3.4 2.8 2.4 2.2 2.0
2/200 x 45* 3.8 3.1 2.7 2.4 2.2
240 x 63 (E) 4.2 3.4 3.0 2.7 2.5
2/240 x 63* 5.6 4.7 4.2 3.7 3.4
300 x 63 (E) 5.7 4.7 4.1 3.7 3.4
2/300 x 45* (E) 6.4 5.6 4.9 4.4 4.1
360 x 63 (E) 6.9 6.1 5.4 4.9 4.5
400 x 63 (E) 7.6 6.7 6.2 5.7 5.2
450 x 63 (E) 8.4 7.5 6.9 6.4 5.8
For all sizes provide lateral restraint at mid-span or at strutting points – Refer detail H10 (page 25)
* Size built-up by vertical nail lamination – refer Detail H1 (page 25).
Minimum bearing = 35 mm at end supports. ROOF AREA
(E) Provide end restraint at supports – refer Detail H8 (page 25). SUPPORTED
STRUTTING UNDERPURLIN
BEAM
STRUTS
STRUT
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
18
ROOF AREA
SUPPORTED
STRUT STRUTTING UNDERPURLIN
BEAM
UNDERPURLIN
STRUTTING BEAM
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
19
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
L1 + L 2
RLW = L1 + L 2
2 RLW = 2
L1
L2 L2
RAFTER
L1
RAFTER
RAFTER
RIDGE
INTERMEDIATE BEAM
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
20
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing = 45 mm at end supports and 70 mm at internal supports for continuous span members.
L2
L1
OH
TRUSSED ROOF
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
21
RLW
=
=
RAFTER
VERANDAH BEAM
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
22
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing = 45 mm at end supports and 100 mm at internal supports for continuous span members.
W
RL
PITCHING BEAM
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
23
n Shaded rows refer to hySPAN+. All other sections are hySPAN PROJECT.
Minimum bearing = 45 mm at end supports and 100 mm at internal supports for continuous span members.
W
RL
PITCHING BEAM
TRUSSED ROOF
Optimised sizing from the full hySPAN range can be obtained using the free designIT software.
www.chhwoodproducts.com.au/designIT
24
‘B’
DETAIL H1
BEAD OF ELASTOMERIC
ADHESIVE BETWEEN
NAIL
UNDERPURLIN
STRUTTING BEAM
MILD STEEL
STRAP
CEILING JOIST
FAN STRUTS
BLOCK
TOP PLATE
STRUTTING BEAM
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
25
G
HAN
O V ER
RAFTER UM
X IM
MA
UNDERPURLIN O/H
H
EP T
U M D UT H
STRUT XI M O
M A I R DS M I E D
B F
OF SPECI
SKEW NAIL AS
BRACE/STRUT TO FASCIA
BRACE STRUTTING BEAM
BIRDSMOUTH DETAIL
STRUTTING BEAM
Notches, cuts and holes in beams, bearers, joists and rafters Connections
Notches, cuts and holes in beams, bearers, joists and rafter members specified Section 9 of AS1684 contains both
within this brochure may have penetrations and notches performed in accordance nominal and common specific tie-down
with AS1684.2, Clause 4.1.6 and Figure 4.1. Guidance for the common holes through and fixing details for timber members
the thickness and depth is provided below. throughout residential constructions.
When applying specific connections to
hySPAN, joint group JD4 shall be used.
Hole through thickness Hole through center of depth
b
hole Ø
d
spacing c
hole Ø
a
For on-site technical and product support, including assistance in sizing freecall 1800 808 131
26
F17 sizes
Builders on the ball use designIT® software. designIT is a powerful tool for building practitioners
to design more economical floor, wall and roof member layouts. designIT has been recently
upgraded and the enhancements include:
Join with other shrewd builders and download designIT series 4 FREE at www.chhsoftware.com/designIT
For on-site, technical and product support, including assistance in sizing, freecall 1800 808 131
chhwoodproducts.com.au/engineeredproducts
hySPAN solutions range †
The table below contains the standard sections for the hySPAN range. F17 hardwood equivalent depths of 120, 140,
190 and 290 may not be readily available in all states. Specifiers should select the nearest hySPAN PROJECT size suitable
for the application or check with your local stockist for availability. For additional product details download a copy of the
‘hySPAN PROJECT hySPAN+ specification’ sheet from www.chhwoodproducts.com.au/hySPAN
Available from:
Technical Support
© February 2010 ® Registered Trademarks of Carter Holt Harvey Woodproducts Australia Pty Limited ABN 93 002 993 106 Date of Publication February 2010 iezziE671