Loopback Test

It enables the information to send from the NE transmitting port and to receive by the receiving
port through the Loopback test to the optical channel. It identify the NE faulty points by levels
and test the nodes and transmission lines working status under the condition the communication
links which are separated.

Alarm Summary
The following are alarms types classified on the severity level.

 Critical alarm
 Major alarm
 Minor alarm
 Warning alarm

1. Critical -This refers to the alarms generated when the traffic interrupts and immediate
troubleshooting is required.

2. Major - This refers to the alarms generated when the traffic gets affected and
immediate troubleshooting is required.

3. Minor- This refers to the alarms generated when the fault does not affect current
traffic, but troubleshooting is required to avoid the week signal transmission.

4. Warning-This refers to the alarms generated when the fault does not affect the current
traffic, but possibly it will do in the future.

Alarm Type
The alarm types involve are:

 Communication alarm
 QOS alarm
 Equipment alarm
 Processing error alarm
 Environmental alarm.
1. Communication alarm - This refers to the alarms related to transmission status, such as
signal loss, frame loss, defect indication, signal degradation, and alarms related to LAN
or communication protocols.

2. Quality of Service alarm - The QOS alarm reflects the transmission performance,
such as response time too long, over-threshold, performance deterioration, etc.
3. Equipment alarm - An equipment alarms relates to equipment hardware, such as
power supply fault, timing port fault, processor fault, transmission/reception fault, and
other equipment components faults.

4. Processing error alarm -It refers to the software-related alarm, such as storage
capacity problem, memory overflow, version mismatch, software error, illegal program
interruption, system-related or NE configuration error, and NE inaccessible.

5. Environmental alarm - It indicates environmental changes, such as


temperature/humidity unacceptable, ventilation or cooling system fault, water/fire
detection, excessive vibration, and door open/closed.

Alarm Detection Point (SDH NE)


SDH NE detects alarms based on the alarm detection points. Alarms that detects using different
detection points which are mentioned as follows:

1. Physical Interface

Default
Detection Point Alarm Name
Severity
Loss Of Signal (LOS) Critical
Transmitting laser failure Critical
Transmitting optical power over threshold Major
Receiving optical power over threshold Major
SDH optical interface Laser bias current over threshold Minor
Laser temperature over threshold Minor
Laser backlight power over threshold Minor
Laser wavelength over threshold Minor
Laser cooling current over threshold Minor
Laser aged Minor
Loss Of Signal (LOS) Critical
SDH electrical interface
Transmission failure Critical
Loss Of Signal (LOS) Critical
Alarm Indication Signal (AIS) Major
PDH electrical interface (2
LOF Critical
M, 34 M, and 140 M)
BER over threshold Major
Remote alarm indication Minor
Data interface Loss Of Signal (LOS) Critical
2. Regenerator Section

Alarm Name Default Severity


Loss of frame Critical
Out of frame Critical
DCCR connection failure Major
Regenerator section signal deterioration Minor
RS alarm indication signal (AIS) Major
Mismatch of regenerator section trace identifier Major
Regenerator section BER over threshold Major
UAS Major

3. Multiplexing Section

Alarm Name Default Severity


MS - Signal Deterioration (SD) Minor
MS- Alarm Indication Signal (AIS) Major
MS- Remote Defect Indication (RDI) Minor
DCC connection failure Major
K2 mismatch Critical
K1/K2 mismatch Critical
BER over threshold Major
UAS Major

4. Administrative Unit

Alarm Name Default Severity


AU loss of pointer (LOP) Critical
AU path alarm indication signal (AIS) Major

5. Tributary Unit

Alarm Name Default Severity


TU pointer loss (LOP) Critical
TU channel AIS Major

6. Higher Order Path Virtual Container


Alarm Name Default Severity
Signal label mismatched (SLM) Major
Channel tracing indication mismatched (TIM) Major
Remote Defect Indication (RDI) Minor
High order path unloaded (UNEQ) Major
Enhanced remote payload defect indication Minor
Enhanced remote connection defect indication Minor
Enhanced remote service defect indication Minor
Payload mismatch Critical
High order path signal deterioration (SD) Minor
Path unloaded Major
Loss of multi frame Critical
BER over threshold (EXC) Major
UAS Major

7. Low Order Path Virtual Container

Alarm Name Default Severity


Signal label mismatch Major
Tracing ID mismatch Major
Remote defect indication Minor
Enhanced remote payload defect indication Minor
Enhanced remote connection defect indication Minor
Enhanced remote service defect indication Minor
Low-order path payload mismatched (PLM) Major
Low-order path unloaded (UNEQ) Major
BER over threshold (EXC) Major
Extension signal label mismatch Major
Remote failure indication Minor
UAS Major
Yellow alarm signal Minor

8. Synchronous Timing Source

Alarm Name Default Severity


Timing input loss Critical
Timing output loss Critical
Loss of frame Critical
Out of frame Critical
Alarm indication signal Major
BER over threshold Major
Synchronous timing source mismatch Major

9. Board

Alarm Name Default Severity


Power supply malfunction Critical
Power failure Critical
Board fault Critical
Board out of position Critical
Omitted board Major
Unknown board type Major
Board type mismatch Critical
Board ejector lever not in position Major
Interface board type mismatch Critical
Interface board not in position Critical
Interface board not working normally Critical
Board running abnormally Critical
OCXO aged Major
Phase-lock loop out of lock Minor

10. Environment

Alarm Name Default Severity


High temperature Warning
Excessive humidity Warning
Fire alarm Warning
Smoke Warning
Door control Warning
Fan fault Major

11. Temperature detection point


When the detection point is the temperature detection point, the alarm of detection-point
temperature overthreshold can be detected on the NM. The default severity of the alarm is
"minor".

12. Fan

Alarm Name Default Severity


Fan rotation speed over threshold Minor
Fan fault Major
Fan out of control Warning

13. Backplane

Alarm Name Default Severity


Loss Of Signal (LOS) Critical
Loss Of Frame (LOF) Critical
Out of frame (OOF) Critical
Regeneration section signal deterioration (SD) Minor
BER over threshold Major
UAS Major
Backplane bus wrong Major

14. Ethernet physical electrical interface

Alarm Name Default Severity


Ethernet disconnected Critical
Loss of received signal (LOS) Critical

15. Ethernet physical optical interface

Alarm Name Default Severity


Ethernet disconnected Critical
Loss of received signal (LOS) Critical
Optical module not installed Critical
Optical module fault Critical
Transmitting optical power over threshold Major
Receiving optical power over threshold Major
Laser bias current over threshold Minor
Laser temperature over threshold Minor

16. ATM Board

Alarm Name Default Severity


Received signal loss Critical
Loss of frame Critical
Loss of pointer Critical
Path alarm indication signal Critical
Path remote defect indication Critical
Loss of Cell Delimitation (LCD) Critical
Out of Cell Delimitation (OCD) Critical
Out of frame Critical
Line alarm indication signal Critical
Line remote defect indication Critical
VP Alarm indication signal Critical

17. EDFA

Alarm Name Default Severity


EDFA receiving signal loss Critical
Transmitting optical power failed Critical
Transmitting optical power overthreshold Major
Receiving optical power overthreshold Major
Laser bias current overthreshold Minor
Laser temperature overthreshold Minor
Module temperature over threshold Minor

18. EDFA Laser

Alarm Name Default Severity


Laser bias current over threshold Minor
Laser temperature over threshold Minor
Outgoing fiber optical power of laser over
Minor
threshold
Laser cooling current over threshold Minor

19. RPR PORT


Alarm Name Default Severity
Protection configuration inconsistent Critical
Number of nodes over threshold Major
Repeated node MAC addresses Critical
Topology inconsistent Critical
Total guarantee bandwidth exceeding total loop
Critical
bandwidth
Total guarantee bandwidth exceeding 50% of
Major
total loop bandwidth

20. EFC Frame

Alarm Name Default Severity


Loss of frame Critical

21. RPR SPAN and VCG (RPR SPAN) Ports

Alarm Name Default Severity


Improper fiber connection Critical
Loss of KEEP ALIVE Major
Residual bandwidth less than 0 Critical
Connection lost Major
Adjacent nodes inconsistent Critical
Bandwidth inconsistent Critical

22. Ethernet and VCG (EOS) Ports

Alarm Name Default Severity


User payload mismatch Major
Customer signal failure Major
Path signal failure Major
Loss of frame Major
Loss of VCG group Major
Receiving PPP/HDLC frame out-of-frame Major

23. VLAN

Alarm Name Default Severity


Incorrect user-specified destination address Major

24. E1 Interface on the AIDI

Alarm Name Default Severity


Loss of signal Critical
Loss of frame Critical
Alarm indication signal Minor
Slip frame Major
Remote alarm indication Minor

Alarm Detection Board (DWDM NE)


The detection point is board for DWDM NE's. The various boardsdetectable alarms description
is as follows.

1. NCP

Alarm Name Default Alarm Severity


Card Not Configure Alarm Critical
Card Dismount Alarm Critical
Card Mismatch Alarm Critical

2. OSC

Alarm Name Default Alarm Severity


Input Power Weak Alarm Major
No Input Power Alarm Critical
LOF Alarm Critical
UAS Alarm Critical
SD Alarm Minor
LOS Alarm Critical
15-Min ES Over Threshold Alarm Major
15-Min SES Over Threshold Alarm Critical
15-Min UAS Over Threshold Alarm Critical
15-Min Bit Error Over Threshold Alarm Major
24-Hour ES Over Threshold Alarm Major
24-Hour SES Over Threshold Alarm Major
24-Hour UAS Over Threshold Alarm Major
24-Hour Bit Error Over Threshold Alarm Major

3. SRM

Alarm Detection Point Alarm Name Default Alarm Severity


Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
OCh path terminal point source LD Bias Current Over
Minor
(Aggregate source) Threshold Alarm
LD TEC Current Over
Minor
Threshold alarm
LD Temperature Offset Over
Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Input Power Overload Alarm Major
Input Power Weak Alarm Major
No Input Power Alarm Critical
LOF Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
LOS Alarm Critical
15-Min B1 Bit Error Over
OCh path terminal point sink Major
Threshold Alarm
(Aggregate sink)
15-Min B2 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
15-Min B2 Bit Error Over
Major
Threshold Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
FEC LOF Alarm Critical
24-Hour Uncorrected Frame
Minor
Over Threshold Alarm
OTN Signal Out of Frame
Major
Alarm
OTN Signal Trace Byte
Major
Mismatch
15-Min OTUk BIP8 BE
Major
Over Threshold Alarm
24-Hour OTUk BIP8 BE
Major
Over Threshold Alarm
LOF Alarm Critical
LOS Alarm Critical
LOP Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
15-Min B1 Bit Error Over
Major
Threshold Alarm
OAC link terminal source 15-Min B2 Bit Error Over
Major
(tributary input) Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
Receiving Signal MS_AIS Minor

4. OA

Alarm Detection Point Alarm Name Default Alarm Severity


Environment Temperature
Card Major
Alarm
Input Power OverLoad
Major
Alarm
OMS link terminal point source
Input Power Weak Alarm Major
No Input Power Alarm Critical
Output Power OverLoad
Major
Alarm
OMS link terminal point sink Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
Pump 1 Bias Current Over
Minor
Threshold
Pump 1 TEC Current Over
Minor
Threshold Alarm
Pump 1 Temperature Over
Minor
Threshold Alarm
Output Power Too High
Major
Alarm
OTS path terminal point
Pump1 End-Of-Life Alarm Warn
source/sink
Pump 2 Bias Current Over
Minor
Threshold
Pump 2 TEC Current Over
Minor
Threshold Alarm
Pump 2 Temperature Over
Minor
Threshold Alarm
Output Power Too High
Major
Alarm
Pump2 Life Alarm Warn
EDF Temperature Over
Warn
Threshold Alarm
Output Power Too High
Major
Alarm
No Input/Output Power
Critical
Alarm
Input/Output Power Too
Major
Low Alarm

5. OMU

Default Alarm
Alarm Detection Point Alarm Name Remarks
Severity
Output Power
Major
Weak Alarm
OMS path terminal No Output Power Applicable to OMU32,
Critical
point source Alarm OMU40, OMU16
Output Power
Major
Too Low Alarm
Input Power
Major
OCh link terminal Weak Alarm
Applicable to OMU08
point source No Input Power
Critical
Alarm
AWG
Temperature Applicable to OMU32 (Active
Card Major
Over Threshold AWG)
Alarm

6. ODU

Default Alarm
Alarm Detection Point Alarm Name Remarks
Severity
No Input Power
Critical
OMS path terminal Alarm Applicable to ODU32, ODU40,
point sink Input Power Weak ODU16
Major
Alarm
Output Power Too
Major
OCh link terminal Low Alarm
Applicable to ODU08
point sink No Output Power
Critical
Alarm
AWG
Applicable to ODU32, ODU40,
Card Temperature Over Major
ODU16 with AWG applied
Threshold Alarm

7. OGMD

Alarm Name Default Alarm Severity


No Input Power Alarm Critical
Input Power Weak Alarm Major

8. OP/OPCS/OPMS

Alarm Name Default Alarm Severity


No Input Power Alarm Critical
Input Power Weak Alarm Major

9. SDM

Alarm Name Default Alarm Severity


No Input Power Alarm Critical
Input Power Weak Alarm Major

10. OPM

Alarm Name Default Alarm Severity


No Input Power Alarm Critical
Input Power OverLoad Alarm Major
Central Wavelength Offset Over Threshold
Major
Alarm
OSNR Over Threshold Alarm Major

11. OTU

Alarm Detection Point Alarm Name Default Alarm Severity


Output Power Too High
Major
Alarm
OCh path terminal point source Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
LD Bias Current Over
Minor
Threshold Alarm
LD TEC Current Over
Minor
Threshold alarm
LD Temperature Offset Over
Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Input Power OverLoad
Major
Alarm
Input Power Weak Alarm Major
No Input Power Alarm Critical
LOF Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
LOS Alarm Critical
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
OCh path terminal point sink Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
Input Power Too High Alarm Major
Input Power Weak Alarm Major
No Input Power Alarm Critical
OAC link terminal point source LOF Alarm Critical
LOS Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
LD Bias Current Over
Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Output Power Too High
OAC link terminal point sink Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical

12. OTUF/OTU 10G

Alarm Detection Point 告警名称 Default Alarm Severity


Environment Temperature
Card Major
Alarm
Input Power Too High Alarm Major
Input Power Weak Alarm Major
No Input Power Alarm Critical
LOF Alarm Critical
OAC link terminal point source
LOS Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
LD Bias Current Over
OAC link terminal point sink Minor
Threshold Alarm
LD TEC Current Over
Minor
Threshold alarm
LD Temperature Offset Over
Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
LD Bias Current Over
OCh path terminal point source Minor
Threshold Alarm
LD TEC Current Over
Minor
Threshold alarm
LD Temperature Offset Over
Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Input Power Too High Alarm Major
Input Power Weak Alarm Major
OCh path terminal point sink
No Input Power Alarm Critical
LOF Alarm Critical
LOS Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
OCh path terminal point sink 15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
FEC LOF Alarm (Only for
Critical
OTUF)

13. GEM

Alarm Detection Point Alarm Name Default Alarm Severity


Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
OCh path terminal point source No Output Power Alarm Critical
(Aggregate source) LD Bias Current Over
Minor
Threshold Alarm
LD TEC Current Over
Minor
Threshold alarm
LD Temperature Offset Over Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Input Power OverLoad
Major
Alarm
Input Power Weak Alarm Major
No Input Power Alarm Critical
LOF Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
OCh path terminal point sink LOS Alarm Critical
(Aggregate sink) 15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min B2 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over
Major
Threshold Alarm
OCh path terminal point sink 24-Hour ES Over Threshold
Major
(Aggregate sink) Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
15-Min Receiving CRC
Error Packet Over Threshold Minor
OAC link terminal point source Alarm
LOS Alarm Critical
14. PWSB

Default Alarm
Alarm Detection Point Alarm Name
Severity
Flood Alarm Critical
High Temperature Alarm Major
Humidity Alarm Major
Fire Alarm Major
Janitor Alarm Major
Invasion Alarm (Moving object) Critical
Windows Break Alarm Critical
Card Unknown External Alarm 1 Critical
Unknown External Alarm 2 Critical
Unknown External Alarm 3 Critical
Bay Power 1 Failure Alarm Critical
Bay Power 1 Input Voltage
Critical
Overvoltage Alarm
Bay Power 2 Failure Alarm Critical
Bay Power 2 Input Voltage
Critical
Overvoltage Alarm
Shelf Power 1 Failure Alarm Critical
Shelf Power 1 Input Voltage
Critical
Overvoltage Alarm
Shelf Power 1 Card Dismount Alarm Critical
Shelf Power 2 FailureAlarm Critical
Shelf Power 2 Input Voltage
Critical
Overvoltage Alarm
Sub-rack port
Shelf Power 2 Card Dismount Alarm Critical
Shelf Power Output Undervoltage
Critical
Alarm
Shelf Power Output Overvoltage
Critical
Alarm
Shelf Power Out of Control Alarm Critical
Shelf Power Off Alarm Critical

15. OHPOW
Clock Source Loss Alarm, the default alarm severity is Critical.

16. OAD

Alarm Detection Point Alarm Name Default Alarm Severity


No Input Power Alarm Critical
OCh link terminal point source
Input Power Weak Alarm Major
No Output Power Alarm Critical
OCh link terminal point sink Output Power Too Low
Major
Alarm

17. FCB

The default alarm severity is critical forFan Failure Alarm.

18. CA

The detection point is the clock receiver, the alarm name is service board Loss of Clock Alarm,
and default alarm severity is Critical.

19. DSAF

Default
Alarm Detection Point Alarm Name Alarm
Severity
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min B2 Bit Error Over
Major
Threshold Alarm
15-Min B1 SES Over
Critical
Threshold Alarm
15-Min B2 SES Over
Critical
Threshold Alarm
Link terminal point sink 15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over
Major
Threshold Alarm
24-Hour B1 SES Over
Major
Threshold Alarm
24-Hour B2 SES Over Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
Client terminal point Source GFP Client Signal Fail ALM Major

Alarm Detection Card (CWDM NE)


The CWDM NE include ZXMP M600 NE in present situation. The detection point is board for
NE’s. The various boards detectable alarms description is as follows:

1. NCP

Alarm Name Default Alarm Severity


Card Not Configure Alarm Critical
Card Dismount Alarm Critical
Card Mismatch Alarm Critical

2. OMD

Alarm Detection Point Alarm Name Default Alarm Severity


No Output Power Alarm Critical
OCh link terminal source Output Power Too Low
Major
Alarm
Input Power Weak Alarm Major
OCh link terminal sink
No Input Power Alarm Critical

3. SRM

Alarm Detection Point Alarm Name Default Alarm Severity


Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
OCh path terminal point source
No Output Power Alarm Critical
(Aggregate source)
LD Bias Current Over
Minor
Threshold Alarm
Module Inner Temperature
Minor
Over Threshold
LD End-Of-Life Alarm Warn
Input Power OverLoad Alarm Major
Input Power Weak Alarm Major
No Input Power Alarm Critical
LOF Alarm Critical
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
LOS Alarm Critical
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min B2 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
OCh path terminal point sink Critical
Alarm
(Aggregate sink)
15-Min UAS Over Threshold
Critical
Alarm
15-Min B2 Bit Error Over
Major
Threshold Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over Threshold
Major
Alarm
24-Hour UAS Over Threshold
Major
Alarm
24-Hour Uncorrected Frame
Minor
Over Threshold Alarm
LOF Alarm Critical
LOS Alarm Critical
OAC link terminal point source LOP Alarm Critical
(Tributary input) UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
15-Min B1 BE Over
Major
Threshold Alarm
15-Min B2 BE Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over
Major
Threshold Alarm
OAC link terminal point source
24-Hour ES Over Threshold
(Tributary input) Major
Alarm
24-Hour SES Over Threshold
Major
Alarm
24-Hour UAS Over Threshold
Major
Alarm
Receiving Signal MS_AIS Minor

4. OTU

Alarm Detection Point Alarm Name Default Alarm Severity


Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
OCh path terminal point source
LD Bias Current Over
Minor
Threshold Alarm
Module Inner Temperature
Minor
Over Threshold
LD End-Of-Life Alarm Warn
Input Power OverLoad
Major
Alarm
OCh path terminal point sink Input Power Weak Alarm Major
No Input Power Alarm Critical
LOS Alarm Critical
Input Power Too High Alarm Major
Input Power Weak Alarm Major
OAC link terminal point source
No Input Power Alarm Critical
LOS Alarm Critical
LD Bias Current Over
Minor
Threshold Alarm
LD End-Of-Life Alarm Warn
Module Inner Temperature
Minor
Over Threshold
OAC link terminal point sink
Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical

5. GEM

Alarm Detection Point Alarm Name Default Alarm Severity


Output Power Too High
Major
Alarm
Output Power Too Low
Major
Alarm
No Output Power Alarm Critical
OCh path terminal point source LD Bias Current Over
Minor
(Aggregate source) Threshold Alarm
LD Temperature Offset Over
Minor
Threshold Alarm
Module Inner Temperature
Minor
Over Threshold
LD End-Of-Life Alarm Warn
Input Power OverLoad
Major
Alarm
Input Power Weak Alarm Major
No Input Power Alarm Critical
OCh path terminal point sink LOF Alarm Critical
(Aggregate sink)
UAS Alarm Critical
SD Alarm Minor
J0 Trace Mismatch Alarm Minor
LOS Alarm Critical
15-Min B1 Bit Error Over
Major
Threshold Alarm
15-Min B2 Bit Error Over
Major
Threshold Alarm
15-Min ES Over Threshold
Major
Alarm
15-Min SES Over Threshold
Critical
Alarm
15-Min UAS Over Threshold
Critical
Alarm
24-Hour B1 BE Over
Major
Threshold Alarm
24-Hour B2 BE Over
Major
Threshold Alarm
24-Hour ES Over Threshold
Major
Alarm
24-Hour SES Over
Major
Threshold Alarm
24-Hour UAS Over
Major
Threshold Alarm
Error Packet Over Threshold
Minor
OAC link terminal point source Alarm
LOS Alarm Critical

6. PCW

Alarm Name Default Alarm Severity


Shelf Power 1 Failure Alarm Major
Shelf Power 1 Input Voltage
Major
Overvoltage Alarm
Shelf Power 1 Output Voltage
Major
Undervoltage Alarm
Card
Shelf Power 1 Output Voltage
Major
Overvoltage Alarm
Fan Failure Alarm Major
Environment Temperature
Major
Alarm
CWDM NE Performance
The CWDM NE (ZXMP M600 NE) detectable performances classify by cards.

1. SRM

Performance Detection Point Performance Event Unit


Output Power dBm
OCh path terminal point source
Laser Bias Current mA
(Aggregate source) o
Laser Temperature Offset C
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
OCh path terminal point sink
15-Min UAS s
(Aggregate sink)
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
OAC link terminal point source 15-Min UAS s
(Tributary input) 24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s

2. OMD

Performance Detection Point Performance Event Unit


OCh link terminal point source Input Power dBm
OCh link terminal point sink Output Power dBm

3. OTU

Performance Detection Point Performance Event Unit


OCh path terminal point source Output Power dBm
Laser Bias Current mA
o
Laser Temperature Offset C
OCh path terminal point sink Input Power dBm
OAC link terminal point source Input Power dBm
Output Power dBm
OAC link terminal point sink Laser Bias Current mA
o
Laser Temperature Offset C

4. GEM

Performance Detection Point Performance Event Unit


Output Power dBm
OCh path terminal point source Laser Bias Current mA
(Aggregate source) o
Laser Temperature Offset C
o
Inner-Module Temperature C
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
OCh path terminal point sink
15-Min UAS s
(Aggregate sink)
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s
OAC link terminal point source Receiving Packet Error Rate -

5. PCW

Board Environment Temperature (Unit: degree Centigrade).

6. NCP

Performance Detection Point Performance Event Unit


Output Power dBm
OSC monitoring channel source Laser Bias Current mA
Input Power dBm
Output Power dBm
OSC monitoring channel sink
Laser Bias Current mA
Input Power dBm

7. ETM

Performance Detection Point Performance Event Unit


15-Min B1 Bit Error Count -
15-Min B1 ES s
15-Min B1 SES s
15-Min B1 UAS s
Link terminal point source
15-Min B2 Bit Error Count -
15-Min B2 ES s
15-Min B2 SES s
15-Min B2 UAS s

DWDM NE Performance
The DWDM NE detectable performances classify by cards.

1. OSC

Performance Event Unit


Input Power dBm
Background Bit Error -
ES sec
SES sec
UAS sec

2.SRM

Performance Detection Point Performance Event Unit


Output Power dBm
OCh path terminal point source Laser Bias Current mA
(Aggregate source) Laser TEC Current mA
o
Laser Temperature Offset C
Input Power dBm
OCh path terminal point sink
15-Min B1 Bit Error Count -
15-Min ES sec
15-Min SES sec
15-Min UAS sec
24-Hour B1 Bit Error Count -
24-Hour ES sec
24-Hour SES sec
24-Hour UAS sec
15-Min B1 Bit Error Count -
15-Min ES sec
15-Min SES sec
OAC link terminal point source 15-Min UAS sec
(Tributary input) 24-Hour B1 Bit Error Count -
24-Hour ES sec
24-Hour SES sec
24-Hour UAS sec

3.OGMD

The performance event is Input Power (Unit: dBm).

4. OP/OPCS/OPMS

The performance event is Input Power (Unit: dBm).

5. SDM

The performance event is Input Power (Unit: dBm).

6. OA

Performance Detection Point Performance Event Unit


o
Card Environment Temperature C
OMS link terminal point source Input Power dBm
OMS link terminal point sink Output Power dBm
Pump 1 Bias Current mA
Pump 1 TEC Current mA
OTS path terminal point o
Pump 1 Temperature Offset C
source/sink
Pump 2 Bias Current mA
Pump 2 TEC Current mA
Pump 2 Temperature Offset oC
Erbium Doped Fiber o
C
Temperature
Output Power dBm

7. OMU

Performance
Performance Detection Point Unit Remark
Event
Applicable to OMU32,
OMS path terminal point source Output Power dBm
OMU40, OMU16
OCh link terminal point source Input Power dBm Applicable to OMU08
AWG o
Card C -
Temperature

8. ODU

Performance
Performance Detection Point Unit Remark
Event
Applicable to OMU32,
OMS path terminal point source Output Power dBm
OMU40, OMU16
OCh link terminal point source Input Power dBm Applicable to OMU08
AWG o
Card C -
Temperature

9. OPM

Performance Event Unit


Input Power dBm
Central Wavelength Nm
Optical Signal-Noise Ratio dB

10. OTUD

Performance Detection Point Performance Event Unit


Board Environment o
OCh path terminal point source C
Temperature
Output Power dBm
OCh path terminal point sink Laser Bias Current mA
Laser TEC Current mA
o
Laser Temperature Offset C
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
15-Min UAS s
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
OAC link terminal point source 15-Min UAS s
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s
Output Power dBm
Laser Bias Current mA
OAC link terminal point sink
Laser TEC Current mA
o
Laser Temperature Offset C

11. OTUF/OTU 10G

Performance Detection Point Performance Event Unit


o
Card Environment Temperature C
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
link terminal point source 15-Min UAS s
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s
FEC Correction Bit Error -
Output Power dBm
Laser Bias Current mA
OAC link terminal point sink
Laser TEC Current mA
o
Laser Temperature Offset C
Output Power dBm
Laser Bias Current mA
OCh path terminal point source
Laser TEC Current mA
o
Laser Temperature Offset C
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
OCh path terminal point sink
15-Min UAS s
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s

12. OADM

Performance Detection Point Performance Event Unit


OCh link terminal point source Input Power dBm
OCh link terminal point sink Output Power dBm

13. FCB

Performance Detection Point Performance Event Unit


Fan Speed Round/s
Card o
FCB Temperature C

14. GEM

Performance Detection Point Performance Event Unit


Output Power dBm
OCh path terminal point source
Laser Bias Current mA
(Aggregate source
Laser TEC Current mA
o
Laser Temperature Offset C
Input Power dBm
15-Min B1 Bit Error Count -
15-Min ES s
15-Min SES s
OCh path terminal point sink
15-Min UAS s
(Aggregate sink)
24-Hour B1 Bit Error Count -
24-Hour ES s
24-Hour SES s
24-Hour UAS s
Receiving CRC Error Packet -
OAC link terminal point source Total Receiving Packet -
Total Receiving Byte -
Total Transmitting Packet -
OAC link terminal point sink
Total Transmitting Byte -

14. DSAF

Performance Detection Point Performance Event Unit


Transmitted GFP Client Data
-
Frame Count
Transmitted GFP Client
-
Management Frame Count
Client terminal point Source
Received GFP Client Data
-
Frame Count
Received GFP Client
-
Management Frame Count
15-Min B1 Bit Error Count -
15-Min B1 ES s
15-Min B1 SES s
15-Min B1 UAS s
Link terminal point sink
15-Min B2 Bit Error Count -
15-Min B2 ES s
15-Min B2 SES s
15-Min B2 UAS s
Single Error cHEC GFP
-
Client terminal point Sink Frame Count
Multi-bit Error tHEC GFP -
Frame Count
Single Error tHEC GFP
-
Frame Count

SDH NE Performance
1. When the detection point locates at the SDH NE physical interface and channel side, ZXONM
E300 can detect the performance items shown in the following table.

Over-threshold
Detection
Performance Item Note Alarm Available or
Point
Not/Severity Level
B1 background
B1 BBE B1 Background block error Major
block error
B1 ES B1 Error second B1 Error second Major
B1 Sevier error
B1 SES B1 Sevier error second Major
second
Regenerator
section Consecutive Sevier error Consecutive Sevier
CSES Major
seconds error seconds
B1 unavailable
B1 UAS B1 Unavailable second Major
second
Out-of-frame
OFS B1 Out-of-frame second Major
second
B2 background
B2 BBE B2 Background block error Major
block error
B2 ES B2 Error second B2 Error second Major
B2 Sevier error
B2 SES B2 Sevier error second Major
second
Consecutive Sevier error Consecutive Sevier
CSES Major
seconds error seconds
Multiplex B2 unavailable
section B2 UAS B2 Unavailable second Major
second
B2 far-end
B2 B2 Far-end background
background block Major
FEBBE block error
error
B2 B2 far-end error
B2 Far-end error second Major
FEES second
B2 B2 Far-end Sevier error B2 far-end Sevier
Major
FESES second error second
Far-end Consecutive Sevier Far-end severely
FCSES Major
error seconds error seconds
B2 B2 Far-end unavailable B2 far-end
Major
FUAS second unavailable second
MS-Protection switching MS-protection No over-threshold
MS-PSD
duration switching duration alarm
MS-Protection switching MS-protection No over-threshold
MS-PSC
count switching count alarm
V5 background
V5 BBE Background block error Major
block error
V5 ES V5 Error second V5 error second Major
V5 Sevier error
V5 SES V5 Sevier error second Major
second
V5 unavailable
V5 UAS V5 Unavailable second Major
second
Lower-order V5 far end
VC12/VC11 V5 V5 Far end background
background block Major
channel FEBBE block error
error
V5 V5 far end error
V5 Far end error second Major
FEES second
V5 V5 Far end severely error V5 far end severely
Major
FESES second error second
V5 V5 Far-end unavailable V5 far-end
Major
FUAS second unavailable second
B3 background
B3 BBE B3 Background block error Major
block error
B3 ES B3 Error second B3 error second Major
B3 Sevier error
B3 SES B3 Sevier error second Major
second
B3 unavailable
B3 UAS B3 Unavailable second Major
second
High-order
VC3/VC4 B3 far-end
B3 B3 Far end background
channel background block Major
FEBBE block error
error
B3 B3 far-end error
B3 Far end error second Major
FEES second
B3 B3 Far end Sevier error B3 far-end Sevier
Major
FESES second error second
B3 B3 Far-end unavailable B3 far-end
Major
FUAS second unavailable second
Positive Pointer justification AU4 pointer
PJC+ Major
C+ justification
AU4, AU3, Negative Pointer AU4 negative
PJC- Major
AU4-nC, justification C- pointer justification
AU3-nC, Protection switching Protection No over-threshold
TU12, TU11 PSD
duration switching duration alarm
Protection No over-threshold
PSC Protection switching count
switching count alarm
TU3 TU3 pointer
TU3 Pointer justification E+ Major
PJE+ justification
TU3 pointer
TU3
TU3 Pointer justification E- negative Major
Tributary unit PJE- justification
TUG3
Protection switching Protection No over-threshold
PSD
duration switching duration alarm
Protection No over-threshold
PSC Protection switching count
switching count alarm
Positive Pointer justification Positive pointer
PJC+ Major
Count justification count
Positive Pointer justification Negative pointer
PJC- Major
Tributary unit Count justification count
TUG12/TU11 Protection switching Protection No over-threshold
PSD
duration switching duration alarm
Protection No over-threshold
PSC Protection switching count
switching count alarm
Interface Coding Violation Interface coding
CV Major
Count Violation count
Negative retiming
Negative Retiming Slippage Count Major
slippage count
PDH electrical Positive retiming
interfaces Positive Retiming Slippage Count Major
slippage count
(1.5M, 2M,
34M, 45M, Number of FAS No over-threshold
Frame Alignment Signal Error Count
140M) error frames alarm
Number of CRC No over-threshold
CRC Error Count
errors alarm
Out-of-frame
OFS Out-of-Frame Second Major
second
No over-threshold
NZBTER -
alarm
FEC frame
No over-threshold
NOBTER -
alarm
No over-threshold
NBYTER -
alarm
No over-threshold
NERROV -
alarm

2. When the detection point locates at the SDH NE Ethernet side, ZXONM E300 can detect the
performance items shown in the following table.

Over-threshold
Detection
Performance Item Note Alarm Available or
Point
Not/Severity Level
Number of received
Receive fragment frames fragment error Major
frames
Number of received
Receive alignment error frames alignment error Major
frames
Number of received
Receive undersize frames Major
undersize frames
Number of received
Receive oversize frames Major
oversize frames
Number of received
Receive CRC error frames Major
CRC error frames
Number of received
Receive discard frames Major
discard frames
Number of received No over-threshold
Receive frame bytes
frame bytes alarm
Number of received No over-threshold
Receive frames
frames alarm
Number of received No over-threshold
Receive multicast frames
multicast frames alarm
Number of received No over-threshold
Receive flow control frames
flow control frames alarm
Number of received No over-threshold
Receive broadcast frames
broadcast frames alarm
Number of received
Receive frames with length of 64 No over-threshold
frames with the
bytes alarm
length of 64 bytes
Number of received
Receive frames with length between frames with the No over-threshold
65-127 bytes length between 65- alarm
127 bytes
Number of received
Receive frames with length between frames with the No over-threshold
128-255 bytes length between 128- alarm
255 bytes
Number of received
Receive frames with length between frames with the No over-threshold
256-511 bytes length between 256- alarm
511 bytes
Number of received
Receive frames with length between frames with the No over-threshold
512-1023 bytes length between 512- alarm
1023 bytes
Number of received
Receive frames with length between frames with the No over-threshold
1024-1522 bytes length between 1024- alarm
1522 bytes
Number of filtered
Receive frames filtered
received frames
Number of received No over-threshold
Receive unicast frames
unicast frames alarm
Number of filtered
Receive bytes filtered Major
received bytes
Number of filtered
Receive unicast frames filtered received unicast Major
frames
Number of filtered
Receive multicast frames filtered received multicast Major
frames
Number of filtered
Receive broadcast frames filtered received broadcast Major
frames
Number of received
Receive error bytes Major
error bytes
Number of dropped
Receive dropped frames with inside received frames with
Major
MAC address error inside MAC address
error
Number of received
Receive system error frames Major
system error frames
Number of received
Receive error frames Major
error frames
Receive unicast error frames Number of received Major
unicast error frames
Number of received
Receive multicast error frames multicast error Major
frames
Number of received
Receive broadcast error frames broadcast error Major
frames
Number of received No over-threshold
Receive MAC control Frames
MAC control frames alarm
Number of received No over-threshold
Receive short events
short events alarm
Number of received
No over-threshold
Receive jumbo bytes correct JUMBO
alarm
bytes
Number of send
Send collision times Major
collision times
No over-threshold
Send bytes Number of bytes sent
alarm
Number of sent No over-threshold
Send unicast frames
unicast frames alarm
Number of sent flow No over-threshold
Send flow control frames
control frames alarm
Number of sent No over-threshold
Send frames
frames alarm
Number of sent No over-threshold
Send multicast frames
multicast frames alarm
Number of sent No over-threshold
Send broadcast frames
broadcast frames alarm
Number of sending
Send delay exceed frames delay exceeding Major
frames
Number of sending
Send delay collision frames delay collision Major
frames
Number of sent non- No over-threshold
Send non-unicast frames
unicast frames alarm
Number of error
Send error bytes Major
bytes sent
Number of sent
Send frames with one collision frames after one Major
collision
Number of sent
Send frames with more collisions frames after more Major
collisions
Number of sent error
Send error frames Major
frames
Number of sent
No over-threshold
Send good flag frames frames with good
alarm
flags
Number of sent No over-threshold
Send MAC control frames
MAC control frames alarm
Number of sent CRC
Send CRC error frames Major
error frames
Number of dropped
Send dropped frames with inside sent frames with
Major
MAC address error inside MAC address
error
Number of sent error
Send error flag frames Major
flag frames
Number of error
Send error frames out of range frames with the Major
length out of range
Number of sent
No over-threshold
Send frames with length of 64 bytes frames with length of
alarm
64 bytes
Number of sent
Send frames with length between 65- frames with length No over-threshold
127 bytes between 65-127 alarm
bytes
Number of sent
Send frames with length between frames with length No over-threshold
128-255 bytes between 128-255 alarm
bytes
Number of sent
Send frames with length between frames with length No over-threshold
256-511 bytes between 256-511 alarm
bytes
Number of sent
Send frames with length between frames with length No over-threshold
512-1023 bytes between 512-1023 alarm
bytes
Number of sent
Send frames with length between No over-threshold
frames with length
1024-1528 bytes alarm
between 1024-1522
bytes
Number of sent
Send jabber frames Major
Jabber frames
Number of JUMBO No over-threshold
Send good jumbo bytes
bytes correctly sent alarm
Number of frames
RPR PORT Send aborted frames Major
with sending aborted
Number of received No over-threshold
Receive frames
frames alarm
Number of received No over-threshold
Receive bytes
frame bytes alarm
Number of received
Receive frames discarded Major
Ethernet discard frames
service Number of received No over-threshold
Receive bytes discarded
bytes discarded alarm
Number of sent No over-threshold
Send frames
frames alarm
No over-threshold
Send bytes Number of bytes sent
alarm
Number of received No over-threshold
Receive unicast frames
unicast frames alarm
Number of received No over-threshold
Receive unicast bytes
unicast bytes alarm
Number of received No over-threshold
Receive non-unicast frames
non-unicast frames alarm
Number of received No over-threshold
Receive non-unicast bytes
non-unicast bytes alarm
Number of sent No over-threshold
Send unicast frames
unicast frames alarm
Number of sent No over-threshold
QOS traffic Send unicast bytes
unicast bytes alarm
Number of sent non- No over-threshold
Send non-unicast frames
unicast frames alarm
Number of sent non- No over-threshold
Send non-unicast byte
unicast bytes alarm
Number of dropped
Receive dropped frames Major
received frames
Number of transited No over-threshold
Transit unicast frames to ringlet
unicast frames alarm
Number of transited No over-threshold
Transit unicast bytes to ringlet
unicast bytes alarm
Number of transited No over-threshold
Transit non-unicast frames to ringlet
non-unicast frames alarm
Number of transited No over-threshold
Transit non-unicast bytes to ringlet
non-unicast bytes alarm
Number of add
No over-threshold
Add unicast frames to ringlet unicast frames to
alarm
ringlet
Number of add
No over-threshold
Add unicast bytes to ringlet unicast bytes to
alarm
ringlet
Number of add
No over-threshold
Add non-unicast frames to ringlet non=unicast frames
alarm
to ringlet
Number of add non-
No over-threshold
Add non-unicast bytes to ringlet unicast bytes to
alarm
ringlet
Number of drop
No over-threshold
Drop unicast frames from ringlet unicast frames from
alarm
ringlet
Number of drop
No over-threshold
Drop unicast bytes from ringlet unicast bytes from
alarm
ringlet
Number of drop non-
No over-threshold
Drop non-unicast frames from ringlet unicast frames from
alarm
ringlet
Number of drop non-
No over-threshold
Drop non-unicast bytes from ringlet unicast bytes from
alarm
ringlet
Number of sent No over-threshold
Send frames
frames alarm
Number of received No over-threshold
Receive frames
frames alarm
Number of received
Receive frames with TTL Expired frames with TTL Major
RPR Span port expired
VCG (RPR
Span) port Number of received
Receive HEC error frames Major
HEC error frames
Number of received
Receive CRC error frames Major
CRC error frames
Number of received
Receive frames with SA equals to
frames with source Major
local mac address
address as the local
node
Number of received
Receive frames with unknown type frames with unknown Major
types
Number of dropped
Receive dropped frames Major
received frames
Count of received No over-threshold
Receive idle frames
IDLE frames alarm
Count of received No over-threshold
Receive idle frame bytes
IDLE frame bytes alarm
Count of received No over-threshold
Receive control frames
control frames alarm
Count of received No over-threshold
Receive control frame bytes
control frame bytes alarm
Count of received No over-threshold
Receive FA frames
fair frames alarm
Count of received No over-threshold
Receive FA frame bytes
fair frame bytes alarm
Count of received
Receive TTL error frames Major
TTL frames
Count of received
Receive length error frames frames with length Major
error
Count of received
Receive length error bytes frame bytes with Major
length error
Count of received
Receive PMD error frames Major
PMD error frames
No over-threshold
Send bytes Number of bytes sent
alarm
Send the frame
Send aborted PMD error frames Major
discarded by PMD
Number of received No over-threshold
Receive GFP control frames
GFP control frames alarm
Number of received
Ethernet Receive GFP dropped control frames GFP dropped control Major
SVCG (EOS) frames
port Number of received
Receive GFP CHEC error frames GFP CHEC error Major
frames
Receive GFP THEC error frames Number of received Major
GFP THEC error
frames
Number of received
Receive GFP EHEC error frames GFP EHEC error Major
frames
Number of received
Receive GFP mismatched type error frames with GFP
Major
frames mismatched type
error
Number of received
Receive GFP mismatched UPI error frames with GFP
Major
frames mismatched UPI
error
Number of received
Receive GFP FCS error frames Major
errir FCS frames
Number of received No over-threshold
Receive GFP frame bytes
GFP frame bytes alarm
Number of received No over-threshold
Receive GFP user data frames
GFP user data frames alarm
Number of received
Receive GFP user data without EHEC GFP user data No over-threshold
frames without EHEC alarm
frames
Number of received
Receive GFP user data with linear No over-threshold
GFP user data with
EHEC frames alarm
linear EHEC frames
Number of received
Receive GFP user data with ring No over-threshold
GFP user data with
EHEC frames alarm
ring EHEC frames
Number of received
Receive GFP user data with FCS No over-threshold
GFP user data with
frames alarm
FCS frames
Number of received No over-threshold
Receive GFP Idle Frames
GFP idle frames alarm
Number of received
Receive GFP client management No over-threshold
GFP client
frames alarm
management frames
Number of received
Receive GFP client management with GFP client No over-threshold
FCS frames management with alarm
FCS frames
Receive GFP mismatched type Number of dropped Major
dropped frames received frames with
mismatched GFP
type
Number of received
Receive GFP single bit CHEC No over-threshold
GFP single bit CHEC
correction frames alarm
correction frames
Number of received
Receive GFP single bit THEC No over-threshold
GFP single bit THEC
correction frames alarm
correction frames
Number of sent GFP No over-threshold
Send GFP data frames
user data frames alarm
Number of sent GFP No over-threshold
Send GFP idle frames
idle frames alarm
Number of sent GFP No over-threshold
Send GFP client data frames
client data frames alarm
Number of sent GFP
No over-threshold
Send GFP client management frames client management
alarm
frames
Number of sent GFP No over-threshold
Send GFP frame bytes
frame bytes alarm
Number of received
Receive GFP dropped frames Major
GFP dropped frames
Number of sent GFP
Send GFP dropped frames Major
dropped frames
Number of received No over-threshold
Receive PPP/HDLC frames
PPP/HDLC frames alarm
Number of received No over-threshold
Receive PPP/HDLC frame bytes
PPP/HDLC bytes alarm
Number of received
Receive PPP/HDLC dropped frames PPP/HDLC dropped Major
frames
Number of received
Receive PPP/HDLC mismatched type PPP/HDLC
Major
error frames mismatched type
error frames
Number of received
Receive PPP/HDLC FCS error
PPP/HDLC FCS Major
Frames
error frames
Number of received
Receive PPP/HDLC aborted frames PPP/HDLC aborted Major
frames
Send PPP/HDLC frames Number of sent No over-threshold
PPP/HDLC frames alarm
Number of sent No over-threshold
Send PPP/HDLC frame bytes
PPP/HDLC bytes alarm
Number of sent
Send PPP/HDLC aborted frames PPP/HDLC aborted Major
frames
Number of add bytes No over-threshold
Add bytes to ringlet 0
to ringlet 0 alarm
Number of drop No over-threshold
Drop bytes from ringlet 0
bytes from ringlet 0 alarm
Number of transited No over-threshold
Transit bytes to ringlet 0
bytes fto ringlet 0 alarm
VLAN
Number of add bytes No over-threshold
Add bytes to ringlet 1
to ringlet 1 alarm
Number of drop No over-threshold
Drop bytes from ringlet 1
bytes from ringlet 1 alarm
Number of transited No over-threshold
Transit bytes to ringlet 1
bytes fto ringlet 1 alarm

3. When the detection point is analog performance, ZXONM E300 can detect the performance
items as shown in the following table.

Over-threshold
Detection
Performance Item Note Alarm Available or
Point
Not/Severity Level
Average value of
Average Value of Detecting Point
the detecting point °C
Temperature
temperature
Maximum value of
Max Value of Detecting Point
Temperature the detecting point °C
Temperature
temperature
Minimum value of
Min Value of Detecting Point
the detecting point °C
Temperature
temperature
Average value of
Average Value of Fan Rotate Speed Rotation/second
fan rotate speed
Maximum value of
FAN Max Value of Fan Rotate Speed Rotation/second
fan rotate speed
Minimum value of
Min Value of Fan Rotate Speed Rotation/second
fan rotate speed
SDH optical Average Value of Receiving Optical Average value of
dBm
interface, Power receiving optical
OSC, ETPIO power
Maximum value of
Max Value of Receiving Optical
receiving optical dBm
Power
power
Minimum value of
Min Value of Receiving Optical Power receiving optical dBm
power
Average value of
Average Value of Transmitting Optical
transmitting optical dBm
Power
power
Maximum value of
Max Value of Transmitting Optical
transmitting optical dBm
Power
power
Minimum value of
Min Value of Transmitting Optical
transmitting optical dBm
Power
power
Average value of
Average Value of Laser Bias Current mA
laser bias current
Maximum value of
Max Value of Laser Bias Current mA
laser bias current
Minimum value of
Min Value of Laser Bias Current mA
laser bias current
Average value of
Average Value of Laser Refrigeration
laser refrigeration mA
Current
current
Maximum value of
Max Value of Laser Refrigeration
laser refrigeration mA
Current
current
Minimum value of
Min Value of Laser Refrigeration
laser refrigeration mA
Current
current
Average value of
Average Value of Laser Temperature °C
laser temperature
Maximum value of
Max Value of Laser Temperature °C
laser temperature
Minimum value of
Min Value of Laser Temperature °C
laser temperature
Average value of
Average Value of Laser Wavelength nm
laser wavelength
Maximum value of
Max Value of Laser Wavelength nm
laser wavelength
Minimum value of
Min Value of Laser Wavelength nm
laser wavelength
Average value of
Average Value of Laser Backface
laser backface dBm
Optical Power
optical power
Maximum value of
Max Value of Laser Backface Optical
laser backface dBm
Power
optical power
Minimum value of
Min Value of Laser Backface Optical
laser backface dBm
Power
optical power
Average value of
Average Value of Receiving Optical
receiving optical dBm
Power
power
Maximum value of
Max Value of Receiving Optical
receiving optical dBm
Power
power
Minimum value of
Min Value of Receiving Optical Power receiving optical dBm
power
Average value of
Average Value of Transmitting Optical
transmitting optical dBm
Power
power
Maximum value of
Max Value of Transmitting Optical
transmitting optical dBm
Power
power
EDFA Minimum value of
Min Value of Transmitting Optical
transmitting optical dBm
Power
power
Average Value of Module Average value of
°C
Temperature module temperature
Maximum value of
Max Value of Module Temperature °C
module temperature
Minimum value of
Min Value of Module Temperature °C
module temperature
Average value of
Average Value of Laser Bias Current mA
laser bias current
Maximum value of
Max Value of Laser Bias Current mA
laser bias current
Minimum value of
Min Value of Laser Bias Current mA
laser bias current
Average Value of Laser Temperature Average value of °C
laser temperature
Maximum value of
Max Value of Laser Temperature °C
laser temperature
Minimum value of
Min Value of Laser Temperature °C
laser temperature
Average value of
Average Value of Laser Bias Current mA
laser bias current
Maximum value of
Max Value of Laser Bias Current mA
laser bias current
Minimum value of
Min Value of Laser Bias Current mA
laser bias current
Average value of
Average Value of Laser Temperature °C
laser temperature
Maximum value of
Max Value of Laser Temperature °C
laser temperature
Minimum value of
Min Value of Laser Temperature °C
laser temperature
Average value of
Average Value of Laser Refrigeration
laser refrigeration mA
Current
EDFA laser current
Maximum value of
Max Value of Laser Refrigeration
laser refrigeration mA
Current
current
Minimum value of
Min Value of Laser Refrigeration
laser refrigeration mA
Current
current
Average value of
Average Value of Laser Outgoing
laser outgoing fiber dBm
Fiber Optical
optical
Maximum value of
Average Value of Laser Outgoing
laser outgoing fiber dBm
Fiber Optical
optical
Minimum value of
Average Value of Laser Outgoing
laser outgoing fiber dBm
Fiber Optical
optical

Abbreviations
Abbreviation Full Name
ADM Add-Drop Multiplexer
AGENT
AI Adapted Information
AIS Alarm Indication Signal
ALS Automatic Laser Shutdown
ANSI American National Standards Institute
APC Automatic Power Control
APR Automatic Power Reduce
APS Automatic Protection Switching
APSD Automatic Power Shutdown
ASON Automatic Switch Optical Network
ATM Asynchronous Transfer Mode
AU-n Administrative Unit,level n
AUG Administrative Unit Group
BA Booster(power) Amplifier
BBER Background Block Error Ratio
BER Bit Error Ratio
BIP-X Bit Interleaved Parity of depth X
BITS Building Integrated Timing Supply
CM Connection Matrix
C-n Container-n
DCC Data Communications Channel
DCM Dispersion Compensation Module
DCN Data Communication Network
DCS Digital Crossconnect System
DDF Digital Distribution Frame
DWDM Dense Wavelength Division Multiplexer
DXC Digital Cross Connect
EOW Engineering Order-Wire
ECC Embedded Control Channel
EDFA Erbium Doped Fiber Amplier
EMC ElectroMagnetic Compatibility
EMI ElectroMagnetic Interference
EML Network Element Management Layer
EMS Equipment Management System
ES Errored Second
ETSI European Telecommunication Standards Institute
FAS Frame Alignment Signal
FEBBE Far End Background Block Error
FEES Far End Errored Second
FESES Far End Severely Errored Second
GUI Graphical User Interface
IP Internet Protocol
International Telecommunication Union-Telecommunication
ITU-T
Standardization Sector
LAN Local Area Network
LAPD Link Access Procedure On D-channel
LAPS Link Access Procedure SDH
LA Line Amplifier
LCT Local Craft Terminal
LO Lower Order
LOF Loss Of Frame
LOM Loss Of Multiframe
LOP Loss Of Pointer
LOS Loss Of Signal
LIT Loss of all Input Timing references
MAF Management Application Function
MCU Managerment Control Unit
MD Mediation Device
MF Mediation Function
MM Multi Mode
MS Multiplex Section
MS-AIS Multiplex Sections - Alarm Indication Signal
MSOH Multiplex Section OverHead
MSP Multiplex Section Protection
MS-PSC Multiplex Sections - Protection Switching Count
MS-PSD Multiplex Sections - Protection Switching Duration
MS-SPRing Multiplexer Section Shared Protection Ring
MST Multiplex Section Termination
MTIE Maximum Time Interval Error
NML Network Manager Layer
NMS Network element Management System
NNI Network Node Interface
OA Optical Amplifier
OAM Operation,Administration and Maintenance
OFA Optical Fiber Amplifier
OHA OverHead Access
OOF Out Of Frame
OSF Operations System Function
OSI Open System Interconnect
OW Order Wire
PA Pre-Amplifier
PCM Pulse Code Modulation
PDH Plesiochronous Digital Hierarchy
PJE+ Pointer Justification Event:+
PJE- Pointer Justification Event:-
PMD Polarization Mode Dispersion
POH Path OverHead
PPI PDH Physical Interface
PS Protection Switching
PSE Protection Switching Event
PTR Pointer
PVC Permanent Virtual Circuit
QA Q Adaptor
QAF Q Adaptor Function
RAM Random Access Memory
RDI Remote Defect Indication
REI Remote Error Indication
RFI Remote Failure Indication
RI Remote Information
RS Regenerator Section
RSOH Regenerator Section OverHead
RST Regenerator Section Termination
SDH Synchronous Digital Hierarchy
SEC SDH Equipment Clock
SEMF Synchronous Equipment Management Function
SES Severely Errored Second
SESR Severely Errored Second Ratio
SETS Synchronous Equipment Timing Source
SM Single Mode
SMN SDH Management Network
SMS SDH Management Sub-network
SNC Sub-Network Connection
SNCP Subnetwork Connection Protection
SPRING Shared Protection Ring
SSD Server Signal Degrade
SSF Server Signal Fail
SSM Synchronization Status Message
STM-N Synchronous Transport Module,level N(N=1,4,16,64)
TD Transmit Degrade
TDEV Time Deviation
TF Transmit Fail
TMN Telecommunications Management Network
TS Time Slot
TSA Time Slot Assignment
TU-m Tributary Unit,level m
TUG-m Tributary Unit Group,level m
UAS Unavailable Second
UBR Unspecified Bit Rate
UNEQ Unequipped
UNI User Network Interface
VC Virtual Channel
VC Virtual Container
VC-n Virtual Container, level n
VLAN Virtual Local Area Network
VP Virtual Path
WAN Wide Area Network
WDM Wavelength Division Multiplexing
WFQ Weighted Fair Queueing
WS Work Station
WSF Work Station Function
WTR Wait to Restore time